• 제목/요약/키워드: exterior noise

검색결과 102건 처리시간 0.023초

주행면 단차에 의한 AGT 교량 충격에 관한 실험적 연구 (A Experimental Study on the Impact of AGT Bridge by the Prominence of Railway Surface)

  • 최성규;조선규;이안호;송재필
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.511-516
    • /
    • 2007
  • Rubber wheeled AGT(Automated Guide-way Transit) system is a prominence transportation system for urban area, because of its low construction cost and management, low noise and vibration and fine exterior view. AGT system uses concrete tracks. Concrete can be easily damaged by the impact, change of temperature and external loads. The fault of concrete track is harmful not only to riding quality but also to bridge. Therefore, in this study, the effects of railway prominence to the bridge are surveyed by experimental method. The experiment was executed for PSC bridge at AGT test line in Kyungsan. And the test results for 5mm, 10mm prominence and without prominence are compared and investigated, according to the vehicle speed.

  • PDF

철도교량의 하로 PSC U거더교 설계적용사례 (The Design Of PSC U-Girder (Song-Lim Gyo) In Korean Railway)

  • 조선규;권순섭;김선곤;이종신;이종민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.545-551
    • /
    • 2006
  • Along with the steady development of Korean Railway construction technology, Contemporary society needs more modernized structures which can meet not only structural value but also aesthetic and environmental value. To follow this demand of society, Pre-Stressed Concrete U-girder bridge(Somg-Lim Gyo, L=330m) is introduced in 'JINJOO-KWANGYANG RAILWAY CONSTRUCTION PROJECT'. On the environmental point of view, the huge noise due to the operation of train can be reduced remarkably by the side beam of U-girder which is high enough to substitute soundproofing wall. Moreover, by aesthetic variation of the shape of outer beams and coping of piers, the exterior view of the bridge can be improved and in accordance with surroundings. Pre-Stressed Concrete U-Girders which are built up above the outer sides of slab deck make easier to secure the clearance of a bridge and make it possible to lower the distance of centroid between superstructure and railroad tracks.

  • PDF

언더컷 앵커 방식의 석재 커튼월 공법 개발 및 성능평가 (Development and Performance Evaluation of Under Cut Anchor Stone Curtain Wall Construction Method)

  • 장극관;박남욱
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권4호
    • /
    • pp.138-146
    • /
    • 2014
  • 최근 지어지고 있는 건축물은 구조적인 안전성과 사용성 뿐만 아니라 다양하고 미려한 외관에 대한 관심이 높아지고 있는 추세이며, 이에 따라 건물의 외장재로 석재 커튼월이 많이 사용되고 있다. 그러나 이러한 석재마감공법은 건물의 중량화를 비롯한 시공성과 보수의 문제점이 발생되고 있으며, 시공시의 소음 진동 등에 의해 민원의 원인이 되기도 한다. 따라서, 본 논문에서는 시공성, 경제성을 향상시키고 보조 고정 홀을 통해 석재 패널의 부분보수가 가능한 언더컷 앵커 방식의 석재 커튼월 시공공법을 개발하였으며, 이에 대한 시공성 및 경제성분석과 안전성을 검토하기 위한 풍압 및 지진하중에 대한 구조성능 평가를 수행하였다. 연구결과, 본 공법이 기존공법에 비해 향상된 시공성과 경제성을 갖는 것으로 나타났으며, 구조성능 평가결과 외장재로서 요구되는 성능을 충족하는 것으로 나타났다.

Evaluation of Geometric Error Sources for Terrestrial Laser Scanner

  • Lee, Ji Sang;Hong, Seung Hwan;Park, Il Suk;Cho, Hyoung Sig;Sohn, Hong Gyoo
    • 대한공간정보학회지
    • /
    • 제24권2호
    • /
    • pp.79-87
    • /
    • 2016
  • As 3D geospatial information is demanded, terrestrial laser scanners which can obtain 3D model of objects have been applied in various fields such as Building Information Modeling (BIM), structural analysis, and disaster management. To acquire precise data, performance evaluation of a terrestrial laser scanner must be conducted. While existing 3D surveying equipment like a total station has a standard method for performance evaluation, a terrestrial laser scanner evaluation technique for users is not established. This paper categorizes and analyzes error sources which generally occur in terrestrial laser scanning. In addition to the prior researches about categorizing error sources of terrestrial Laser scanning, this paper evaluates the error sources by the actual field tests for the smooth in-situ applications.The error factors in terrestrial laser scanning are categorized into interior error caused by mechanical errors in a terrestrial laser scanner and exterior errors affected by scanning geometry and target property. Each error sources were evaluated by simulation and actual experiments. The 3D coordinates of observed target can be distortedby the biases in distance and rotation measurement in scanning system. In particular, the exterior factors caused significant geometric errors in observed point cloud. The noise points can be generated by steep incidence angle, mixed-pixel and crosstalk. In using terrestrial laser scanner, elaborate scanning plan and proper post processing are required to obtain valid and accurate 3D spatial information.

외부 전동블라인드의 사양에 따른 창호 차음성능 개선 효과 (Improvement of sound insulation performance of windows according to the specifications of the external electric blinds)

  • 강민우;이희동;오양기
    • 한국음향학회지
    • /
    • 제41권6호
    • /
    • pp.621-628
    • /
    • 2022
  • 도로교통 소음이나 항공기 소음 등의 건물 외부소음을 저감하기 위한 가장 현실적인 방안은 각 건물의 발코니와 창호, 외벽 등 수음점에서의 차음성능을 강화하는 것이다. 그러나 아직 건물 외부의 차양장치가 광범위하게 사용되지 않고 있는 현실에 비추어 루버나 블라인드 등의 창호 외부장치를 활용하는 차음성능 개선 연구는 많지 않다. 특히 외장형 블라인드는 아침-저녁의 강한 일사의 유입을 건물 외부에서 차단하는 차광 효과 뿐 아니라 출퇴근 시간대에 발생하는 피크 소음을 차단하는 차음 효과도 동시에 목표할 수 있다. 이 연구에서는 가장 효율적인 창호 외부 차양장치의 하나인 외부 전동블라인드(External Electric Blind, EEB)를 활용하여 외부소음에 대한 차음성능을 개선하고자 하는 연구를 수행하였다. 차광 용도로 개발된 외부 전동블라인드의 구성을 변화시켜가면서 다양한 차음성능 실험을 수행하였다. 이를 통해 일반 창호의 저감 성능 대비 외부 전동블라인드를 설치함으로써 6 dB의 추가 차음성능을 얻을 수 있음을 검증하였다.

실측과 시뮬레이션을 통한 초고층 주거건물에서의 연돌효과 문제의 해결 (Solving the Problems Caused by Stack Effect in a High-rise Residential Building through Field Measurement and Simulation; Case Study)

  • 구성한;조재훈;여명석;김광우
    • 한국주거학회논문집
    • /
    • 제16권4호
    • /
    • pp.73-80
    • /
    • 2005
  • A high-rise residential building experienced stack effect problems during the winter such as difficulties in opening residential entrance doors and whistling noise from elevator doors generated by airflow. Field measurements were carried out on the building and the problems were verified by the analysis of the measurement results from three points of view: the total stack pressure difference, pressure distribution on each floor, and the location of the neutral pressure level. Based on the analysis of the three key parameters, possible solutions were proposed, such as zoning vertical shafts, lessening the airflow from the entrance doors on basement floors and lobby floor by installing vestibules, improving the airtightness of exterior walls, and installing separation doors where the problems occur. Simulations of proposed solutions were conducted and the effects of reducing the pressure difference were evaluated. Stack effect problems in a high-rise residential building were verified through field measurements and could be mitigated by the solutions which were drawn from the analysis of the field measurements and the simulation results.

연돌효과 저감을 위한 E/V샤프트 냉각장치의 적용에 대한 연구 (A study on application of an E/V shaft cooling system to reduce the stack effect in high-rise building)

  • 임현우;이준호;서정민;송두삼;이중훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.284-292
    • /
    • 2009
  • The stack-effect in high-rise buildings in winter causes many problems such as difficulties in opening or closing doors, infiltration, energy loss, noise and fire protection. Stack effect is influenced by temperature difference between the interior and exterior of building and the height of building. As an attenuation method for stack effect, the architectural methods are generally used. However, as though architectural methods were fully adopted, the problems are reported as ever in tall building. In this study, a new method to reduce stack effect will be suggested. As an active control method against the stack effect, E/V shaft natural cooling method is suggested. In this paper, the concept of E/V shaft natural cooling system and its reduction performance of stack effect by simulation and field measurement will be reported.

  • PDF

현장실험을 통한 학교교실의 벽체 차음성능 및 측로전달소음 조사 (Investigation of the sound insulation performance of walls and flanking noises in classrooms using field measurements)

  • 류다정;박찬재;한찬훈
    • 한국음향학회지
    • /
    • 제36권5호
    • /
    • pp.329-337
    • /
    • 2017
  • 미국과 영국에서는 교실의 적정한 음환경을 제공하기 위하여 잔향시간 및 배경소음에 대한 기준이 수립되어 있다. 또한 이를 실현하기 위한 건축계획방법 및 실내마감재 적용에 대한 가이드라인을 제시하고 있다. 그러나 대한민국의 경우 학교 교실의 배경소음 기준을 만족하기 위한 가이드라인이 부족할 뿐만 아니라 이에 기초가 되는 교실 벽체의 차음성능에 대한 실태조사가 부족한 실정이다. 본 연구에서는 학교 교실의 실내외 소음에 대한 차음성능을 조사하기 위하여 대한민국 청주시 소재 중학교 2개소의 외부벽체와 실간벽체의 구조를 조사하였다. 실내외 벽체의 차음성능 및 측로전달소음을 비교분석하기 위하여 투과손실, 가중 표준화 음압레벨차, 음향 감쇠 계수, 신호대잡음비 등을 측정하였다. 연구결과 실간벽체의 경우 건식벽으로 건립된 학교의 차음성능이 습식벽보다 높게 나타났으며, 특히 중고파수대역에서 높은 차음성능을 나타내었다. 외부벽체의 경우 각 학교 별로 차음성능을 비교하였을 때 단창을 이중으로 배치한 학교보다 복층유리를 사용한 학교의 성능이 더 높은 것으로 나타났다. 또한 측로전달소음의 경우 창문을 모두 개방하거나 복도 측 창문과 문을 연 경우 기준을 초과하는 것으로 나타나 내부 소음에 의해 학생이 음성전달에 방해를 받을 수 있음을 알 수 있었다.

Beam Tracing 기법을 이용한 수동 소나 센서의 수신 음압해석 프로그램 개발 (Development of Received Acoustic Pressure Analysis Program of CHA using Beam Tracing Method)

  • 권현웅;홍석윤;송지훈;전재진;서영수
    • 대한조선학회논문집
    • /
    • 제50권3호
    • /
    • pp.190-198
    • /
    • 2013
  • In order to predict acoustic pressure distributions by exterior incident wave at Cylindrical Hydrophone Array (CHA) sensor's positions, acoustic pressure analysis is performed by using beam tracing method. Beam tracing method is well-known of reliable pressure analysis methods at high-frequency range. When an acoustic noise source is located at the center of rectangular room, acoustic pressure analysis is performed by using both beam tracing method and Power Flow Boundary Element Method (PFBEM). By comparing with results of beam tracing method and those of PFBEM, the accuracy of beam tracing method is verified. We develop the CHA pressure analysis program by verified beam tracing method. The developed software is composed of model input, sensor array creator, analysis option, solver and post-processor. We can choose a model option of 2D or 3D. The sensor array generator is connected to a sonar which is composed of center position, bottom, top and angle between sensors. We also can choose an analysis option such as analysis frequency, beam number, reflect number, etc. The solver module calculates the ray paths, acoustic pressure and result of generating beams. We apply the program to 2D and 3D CHA models, and their results are reliable.

동축원통 전극내의 파티클에 의한 음향신호 분석 (Analysis of Sound Signal by Conducting Particle in Coaxial Cylindrical Electrodes)

  • 조국희;권동진;곽희로
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권6호
    • /
    • pp.104-110
    • /
    • 1997
  • 본 논문에서는 동축원통 전극내의 파티클이 외함에 충돌하여 발생하는 음향신호를 초음파 센서와 진동센서를 이용하여 측정하고, 이들 신호의 분석과 주파수 스펙트럼 분석에 관하여 연구하였다. 동축원통 전극에서 파티클이 반동운동할 경우의 음향신호는 파티클이 없을 경우의 잡음신호보다 10[dB] 이상의 크기로 측정되어 초음파 및 진동센서를 GIS 외함에 부착하여 측정할 수 있었다. 또한 파티클이 외함에 충돌할 경우와 파티클에 의한 부분방전 및 절연파괴시의 초음파 및 진동신호를 측정하여 밀폐화된 GIS 내부의 파티클이 절연에 미치는 상태를 추정 가능하였다. 또한 파티클의 지름 및 길이의 증가에 따른 측정신호와의 상관관계를 진동신호의 최대진폭 및 평균평방제곱근으로 분석하여 파티클의 크기를 추정 가능함을 확인하였다.

  • PDF