• 제목/요약/키워드: exterior and interior

검색결과 894건 처리시간 0.027초

친환경 황토벽체의 차음성능 평가에 관한 연구 (The sound insulation performance of eco-friendly loess brick wall)

  • 이태강;김율;송국곤;김선우
    • KIEAE Journal
    • /
    • 제9권6호
    • /
    • pp.13-18
    • /
    • 2009
  • Korean traditional houses have been developed in harmony with natural environment and comfortable indoor condition by using the natural resources including building layout, space composition and materials. Originally Korea traditional architectures have used wood lintel constructions and loess walls through the many years. Theses loess have many strength such as highly heat capacity, controling of humidity, a deodorant than any other materials. Nowaday it is recommended to use exterior and interior walls in loess wall to meet the eco-friendly materials to improve our residental environmental. Thus this study aims to research the sound insulation performance of traditional loess brick wall varied with thickness, thermal insulation materials and cavity wall. The sound insulation performance of these loess walls are compared with other masonry wall's and sound insulation performance of th walls were tested in anechoic laboratory to measure the sound transmission loss of these walls. The loess brick wall with 75mm thickness of cavity is shown the sound insulation performance with Rw 57 which is nearly same performances of 1B brick wall and cement 8' block wall, The improving effect of insulation materials is shown in the high frequency bandwidth. Especially, there is improving as much as 11 dB using the extruded poly stylene form(75mm) and poly ethylene film(0.7mm).

지상형 탄약고 폭발 시 안전거리 위반율에 따른 위험노출대상의 피해 수준 분석 연구 (Expected Damage Analysis of Risk Exposure Object by Violation Rate of Safety Distance in Explosion of Ground Type Magazine)

  • 함태윤;이재준
    • 한국안전학회지
    • /
    • 제37권4호
    • /
    • pp.92-100
    • /
    • 2022
  • Of the Korean military's 3,959 ammunition depots, 1,007 - more than 25% - violate safety requirements for distance and equipment. There is a risk of explosion in old depots that are vulnerable to various interior and exterior accidents. This paper examines 10 scenarios, with varying values for ammunition amount and safety distance. The study calculated the overpressure that can be applied to risk-exposure objects, based on the safety distance; expected damage was predicted using constructed spatial information from 3D explosion simulations. The simulations confirmed that explosion overpressure increased the most when the safety distance violation rate increased from 80% to 90%. It also confirmed that secondary damage such as fire and explosion can cause casualties and property damage when the violation rate is 60% or higher. The results show that building collapse becomes a risk with a violation rate of 70% or higher. We conclude that taking ammunition depot safety distance violation into account when planning military facilities and their land utilization could better protect life and property.

CFT와 합성보로 이루어진 CJS합성구조시스템의 내진성능 실험 연구 (Experimental Study of the Seismic Performance of CJS Hybrid Structural Systems Connected to the CFT Column)

  • 임창규;신지욱;문아해;김용남;이기학
    • 한국지진공학회논문집
    • /
    • 제26권2호
    • /
    • pp.83-93
    • /
    • 2022
  • In this study, to verify the structural performance of the Composite Joint System (CJS) hybrid structural model, a cyclic load test was performed and evaluated and verified through the test. To verify the structural performance of the CJS hybrid structural systems' joint and evaluate the seismic performance, four three-dimensional real-size specimens were developed with three internal beam-column specimens and one external beam-column specimen. The three interior column specimens were classified by different methods of joining the upper column and lower column, and the same bonding method as the primary specimen was used for the exterior column. The structural performances in terms of drift, strength, and energy dissipation capacity were analyzed and compared based on the experimental results. From the displacement-based loading experiment, all specimens showed a lateral drift of 4.0% without any significant strength drop and stable energy dissipation capacity.

차량용 이산화탄소 열펌프 시스템의 냉난방 성능 비교평가 (Comparative Evaluation of the Cooling and Heating Performance of a $CO_2$ Heat Pump System for Vehicles)

  • 김성철;김민수
    • 한국자동차공학회논문집
    • /
    • 제17권2호
    • /
    • pp.126-131
    • /
    • 2009
  • A $CO_2$ heat pump system was designed for both cooling and heating in the cabin of electric vehicles, hybrid vehicles or fuel cell vehicles, In this study, the performance characteristics of the heat pump system without any supplementary heating device were analyzed and the heating performance was compared with the cooling performance for various operating conditions. Experiments were carried out by changing the speed of electric drive compressor, the air flow rate of interior heat exchanger and the air inlet temperature and speed of exterior heat exchanger. Therefore, the cooling/heating capacities and the corresponding COPs are quantified. Also, the heat pump system showed an improved performance for the cooling operation and the heating operation. In this study, the experimental results can be used to evaluate the effect of system design changes on system performance as well as the development of a highly efficient heat pump system.

Seismic assessment of R/C residential buildings with infill walls in Turkey

  • Korkmaz, Kasim Armagan;Kayhan, Ali Haydar;Ucar, Taner
    • Computers and Concrete
    • /
    • 제12권5호
    • /
    • pp.681-695
    • /
    • 2013
  • In 1999 Marmara and 2011 Van earthquakes in Turkey, majority of the existing buildings either sustained severe damage or collapsed. These buildings include masonry infill walls in both the interior and exterior R/C frames. The material of the masonry infill is the main variant, ranging from natural stones to bricks and blocks. It is demanding to design these buildings for satisfactory structural behavior. In general, masonry infill walls are considered by its weights not by interaction between walls and frames. In this study, R/C buildings with infill walls are considered in terms of structural behavior. Therefore, 5 and 8-story R/C buildings are regarded as the representative models in the analyses. The R/C representative buildings, both with and without infill walls were analyzed to determine the effects of structural behavior change. The differences in earthquake behavior of these representative buildings were investigated to determine the effects of infill walls leading structural capacity. First, pushover curves of the representative buildings were sketched. Aftermath, time history analyses were carried out to define the displacement demands. Finally, fragility analyses were performed. Throughout the fragility analyses, probabilistic seismic assessment for R/C building structures both with and without infill walls were provided. In this study, besides the deterministic assessment methodology, a probabilistic approach was followed to define structural effect of infill walls under seismic loads.

두통(頭痛)의 원인(原因)과 침구치료혈(鍼灸治療穴)에 관(關)한 문헌적(文獻的) 고찰(考察) (The Treatise research about Acupuncture Point for Symptoms of Headache)

  • 박성호;이병렬
    • Journal of Acupuncture Research
    • /
    • 제15권2호
    • /
    • pp.455-478
    • /
    • 1998
  • The result as following one was founded that investigate cause and acupuncture point for symptoms of headache; 1. Headache in distinction from doo-pung(頭風.) was defined that it' period is short and treatment is easy. 2. The cause of headache was classified according to the interior and exterior cause of the body. 3. Total number of used acupuncture point was one hundred and six, and in order of using time acupuncture point was appeared as LI4(15), LU7(12), GB20(12), BL2(11), GV20(9), TE23(9), SI3(7), GV24(7), GV23(7) 4. The meridian distribution of acupuncture point is appeared as Bladder Meridian(21points), Gallbladder Meridian(18points), Governer vesseI(14points), Triple Energizer meridian(12points), Large Intestine Meridian(9points), Small Intestine Meridian(7points), Stomach Meridian(7points) 5. According to headache position, the distribution of acupuncture point $Yangmy\check{o}ng\;Ky\check{o}ng$ and Governer vessel was used to frontal headache, Soyang $Ky\check{o}ng$ to migraine, Taeyang $Ky\check{o}ng$ and Governer vessel to occipital headache. 6. LI4(合谷) and LU7(列缺) was used to general headache as basic acupuncture point.

  • PDF

Voxel-Based Thickness Analysis of Intricate Objects

  • Subburaj, K.;Patil, Sandeep;Ravi, B.
    • International Journal of CAD/CAM
    • /
    • 제6권1호
    • /
    • pp.105-115
    • /
    • 2006
  • Thickness is a commonly used parameter in product design and manufacture. Its intuitive definition as the smallest dimension of a cross-section or the minimum distance between two opposite surfaces is ambiguous for intricate solids, and there is very little reported work in automatic computation of thickness. We present three generic definitions of thickness: interior thickness of points inside an object, exterior thickness for points on the object surface, and radiographic thickness along a view direction. Methods for computing and displaying the respective thickness values are also presented. The internal thickness distribution is obtained by peeling or successive skin removal, eventually revealing the object skeleton (similar to medial axis transformation). Another method involves radiographic scanning along a viewing direction, with minimum, maximum and total thickness options, displayed on the surface of the object. The algorithms have been implemented using an efficient voxel based representation that can handle up to one billion voxels (1000 per axis), coupled with a near-real time display scheme that uses a look-up table based on voxel neighborhood configurations. Three different types of intricate objects: industrial (press cylinder casting), sculpture (Ganesha idol), and medical (pelvic bone) were used for successfully testing the algorithms. The results are found to be useful for early evaluation of manufacturability and other lifecycle considerations.

소양인(少陽人) 망음증(亡陰證)에 관한 고찰 - 갑오본(甲午本)과 신축본(辛丑本)을 중심으로 - (The Study on the Mangeum-syndrome(亡陰證) of Soyangin in Sasang Constitutional Medicine (SCM))

  • 권오일;이지현;김윤희;황민우
    • 사상체질의학회지
    • /
    • 제23권1호
    • /
    • pp.44-52
    • /
    • 2011
  • 1. Objectives: This research was proposed to find out how the recognition on Mangeum-syndrome(亡陰證) of Soyangin in Sasang Constitutional Medicine(SCM) evolved from "Donguisusebowon-GabObon(東醫壽世保元甲午本)"(DGO) to "Donguisusebowon-ShinChukbon(東醫壽世保元辛丑本)"(DSC). 2. Methods: We compared "Donguisusebowon-GabObon(東醫壽世保元甲午本)"(DGO) with "Donguisusebowon-ShinChukbon(東醫壽世保元辛丑本)"(DSC) to know how the symptom, mechanism, treatment principle and treatment methods on Mangeum-syndrome(亡陰證) of Soyangin in Sasang Constitutional Medicine(SCM). 3. Results and Conclusions: (1) The way to categorize the Exterior Disease and Interior Disease was different between DSC and DGO. (2) There was only a fundamental mechanism about the Boktongseolsa-syndrome(gastralgia and diarrhea) and no treatment principles and treatment methods about it in DGO. But the Boktongseolsa-syndrome was evolved into Mangeum-syndrome(亡陰證) in DSC with a detailed mechanism and treatment principles of it. (3) The evolution of Mangeum-syndrome(亡陰證) in DSC from Boktongseolsa-syndrome in DGO was attributed to the experience of treatment on Seomeo-syndrome(譫語證).

두통(頭痛)의 침구치료혈(鍼灸治療穴)에 관(關)한 문헌적(文獻的) 고찰(考察) (The Treatise research about Acupuncture Point for Symptoms of Headache)

  • 박성호;이병렬
    • 혜화의학회지
    • /
    • 제11권1호
    • /
    • pp.111-135
    • /
    • 2002
  • The result as following one was founded that investigate cause and acupuncture point for symptoms of headache, 1. Headache in distinction from doo-pung(頭風) was defined that it' period is short and treatment is easy. 2. The cause of headache was classified according to the interior and exterior cause of the body. 3. Total number of used acupuncture point was one hundred and six, and in order of using time acupuncture point was appeared as LI4(15), LU7(12), GB20(12), BL2(11), GV20(9), TE23(9), SI3(7), GV24(7), GV23(7) 4. The meridian distribution of acupuncture point is appeared as Bladder Meridian(21points), Gallbladder Meridian(18points), Governer vessel(14points), Triple Energizer meridian(12points), Large Intestine Meridian(9points), Small Intestine Meridian(7points), Stomach Meridian(7points) 5. According to headache position, the distribution of acupuncture point was appeared that $Yangmy\breve{o}ng$ $Ky\breve{o}ng$ and Governer vessel was used to frontal headache, Soyang $Ky\breve{o}ng$ to migraine, Taeyang $Ky\breve{o}ng$ and Governer vessel to occipital headache. 6. LI4(合谷) and LU7(列缺) was used to general headache as basic acupuncture point.

  • PDF

Seismic fragility of regular masonry buildings for in-plane and out-of-plane failure

  • Karantoni, Fillitsa;Tsionis, Georgios;Lyrantzaki, Foteini;Fardis, Michael N.
    • Earthquakes and Structures
    • /
    • 제6권6호
    • /
    • pp.689-713
    • /
    • 2014
  • The seismic vulnerability of stone masonry buildings is studied on the basis of their fragility curves. In order to account for out-of-plane failure modes, normally disregarded in past studies, linear static Finite Element analysis in 3D of prototype regular buildings is performed using a nonlinear biaxial failure criterion for masonry. More than 1100 analyses are carried out, so as to cover the practical range of the most important parameters, namely the number of storeys, percentage of side length in exterior walls taken up by openings, wall thickness, plan dimensions and number of interior walls, type of floor and pier height-to-length ratio. Results are presented in the form of damage and fragility curves. The fragility curves correspond well to the damage observed in masonry buildings after strong earthquakes and are in good agreement with other fragility curves in the literature. They confirm what is already known, namely that buildings with stiff floors or higher percentage of load-bearing walls are less vulnerable, and that large openings, taller storeys, larger number of storeys, higher wall slenderness and higher ratio of clear height to horizontal length of walls increase the vulnerability, but show also by how much.