• Title/Summary/Keyword: exposure time schedule

Search Result 20, Processing Time 0.023 seconds

Operation Efficiency Estimation of PET/CT Center by Work Form and Exposure Dose (근무형태 및 피폭선량에 따른 PET/CT실의 운영 효율성 평가)

  • Kweon, Oh-Jin;Jung, Su-Hee;Baek, Seung-Chan;Kim, Kyeong-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.93-97
    • /
    • 2009
  • Purpose: Recognize circulation work system and fixing work system's merits and demerits that is enforced in operation of PET/CT center in sudden increase recently. Wish to estimate connectivity degree of individual exposure dose and PET/CT working that is managed periodically through this and look for operation efficiency of PET/CT center. Materials and Methods: (1) Find interrelationship of length of service to be individual exposure dose and PET/CT through TLD interpretation. Specially, evaluate on the basis of data of 2.5 years until 2 quarters 2006~2008 year that show patient increase rapidly the latest. (2) Recognize what countermeasure is evaluating problems happened at circulation work system and fixing work system. Results: Patient examination's number was 14,674 items until 2 quarters 2006~2008 year, and the $^{18}F$-FDG average injection amount was 461.5 MBq. 2 people of 10 radiotechnologist did fixing work PET area and GAMMA area each, and 8 people did circulation work of 3 times for 2.5 years. Average exposure dose that PET area and Gamma area's circulation men in service receive was 1.32 mSv, and PET area men in services came out average 0.825 mSv high than Gamma area men in services. Nurse's exposure dose is 0.28 mSv, and next 2 reason is conjectured. One is contact with patient that medicate $^{18}F$-FDG injection, and another is consultation about patient's next time schedule after examination end. Although exposure dose's amount is not much, is expected to consider continuation work possibility by exposure dose in case is a nurse with pregnancy possibility. Also, $^{131}I$-isotope therapy area's radiotechnologist that use capsule appeared by 0.12 mSv and a nuclear medicine doctor appeared by exposure dose that is less of 0.11 mSv. Conclusions: In case do PET/CT center circulation work after a long time, connoted danger that most men in service is consecutiveness deficiency of business and individual exposure dose increase at early 1 month. Specially, way for individual exposure dose's decrease should be considered. Also, need to evaluate abhorrent work form for efficient work system introduction, and enforce circulation and fixing work suggestion suitable shift working. Finally, must make normalized business guide and so on to prevent circulation work people's business efficiency decline.

  • PDF

Changes in the marketing direction and form of exhibitions using social media

  • Im-yeoreum Kim;Gi-Hwan Ryu
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.268-272
    • /
    • 2023
  • With the development of SNS, companies and individuals are actively marketing through social media to develop their own products. It is also important to post posts promoting on simple SNS or to show a lot of exposure using algorithms, but customers upload reviews or proof shots of the product on their own, naturally increasing the exposure of the product and increasing the purchasing power of potential customers. As the number of products that users want to purchase through SNS is increasing, they want to access and purchase not only tangible products such as goods and food, but also intangible services through SNS. In this paper, we would like to study exhibitions that have both tangible and intangible characteristics. SNS accounts that mainly introduce these products by searching for reviews have been created while spending leisure time such as exhibitions and fairs, reducing the hassle of searching for personal interests on search engines, and providing prices and reviews from the exhibition's schedule, lowering entry barriers and increasing purchasing power. Using this point, many exhibitions not only display works, but also open various experience centers, and create a photo zone or a unique exhibition hall atmosphere to attract many customers. In this study, we study the impact of SNS on the leisure culture of exhibition. The marketing direction in the situation where SNS marketing is becoming the mainstream is presented, and the change in the form of exhibition is described and presented as an academic approach.

Effects of Alcohol Exposure on Ship Operational Ability (알코올이 선박운항능력에 미치는 영향에 관한 기초연구(I))

  • Kim, Hong-Tae;Yang, Chan-Soo;Yang, Young-Hoon;Lee, Bong-Wang;Lee, Chang-Min;Lee, Jae-Hwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.5 s.143
    • /
    • pp.516-527
    • /
    • 2005
  • It has been estimated that up to $80\%$ of all marine accidents have human elements as a cause. Out of these, human elements of crew fatigue is one of the main causes of marine accident. Crew fatigue involves sleep, schedule, workload, off-time, alcohol, health and stress. With a ship handling simulator, the effect of alcohol on ship operational performance is studied for each 0.05 and 0.08 $\%$ blood alcohol concentrations(BAC). The main effect of alcohol was found that ship operational performance was significantly impaired by alcohol compared to that in the non-alcohol condition. The results of this research can be used as basic data to minimize marine accidents.

Development of a Reduction Algorithm of GEO Satellite Optical Observation Data for Optical Wide Field Patrol (OWL)

  • Park, Sun-youp;Choi, Jin;Jo, Jung Hyun;Son, Ju Young;Park, Yung-Sik;Yim, Hong-Suh;Moon, Hong-Kyu;Bae, Young-Ho;Choi, Young-Jun;Park, Jang-Hyun
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.3
    • /
    • pp.201-207
    • /
    • 2015
  • An algorithm to automatically extract coordinate and time information from optical observation data of geostationary orbit satellites (GEO satellites) or geosynchronous orbit satellites (GOS satellites) is developed. The optical wide-field patrol system is capable of automatic observation using a pre-arranged schedule. Therefore, if this type of automatic analysis algorithm is available, daily unmanned monitoring of GEO satellites can be possible. For data acquisition for development, the COMS1 satellite was observed with 1-s exposure time and 1-m interval. The images were grouped and processed in terms of "action", and each action was composed of six or nine successive images. First, a reference image with the best quality in one action was selected. Next, the rest of the images in the action were geometrically transformed to fit in the horizontal coordinate system (expressed in azimuthal angle and elevation) of the reference image. Then, these images were median-combined to retain only the possible non-moving GEO candidates. By reverting the coordinate transformation of the positions of these GEO satellite candidates, the final coordinates could be calculated.

Effects of Alcohol Exposure on Ship Operational Ability (알코올이 선박운항능력에 미치는 영향)

  • Kim Hong-Tae;Yang Chan-Su;Lee Bon-Wang;Yang Young-Hoon;Kim Sun-Young
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2004.11a
    • /
    • pp.49-56
    • /
    • 2004
  • It has been estimated that up to $80\%$ of all marine accidents have human elements as a cause. t of these, human elements of crew fatigue is main causes of marine accident. Crew fatigue involves sleep, schedule. workload. off-time. alcohol health and stress. With a ship handling simulator, the effect of alcohol on ship operational performance is studied for each 0.05 and $0.08g\%$ blood alcohol concentrations. A main effect for alcohol was found indicating that ship operational performance was significantly impaired by this alcohol relative to performance in the non-alcohol condition. The results of this research can be applied to minimize marine accidents as basic data.

  • PDF

The Effects of Quibitang in the Chronic Mild Stress Model of Depression in Rats (우울증유발(憂鬱症誘發) 흰쥐에 대한 귀비양(歸脾揚)의 항우울효과(抗憂鬱效果))

  • Seong, Woo-Yong;Whang, Wei-Wan;Park, Eun-Hye;Lee, Jung-Ryun;Kim, Hyun-Taek;Kim, Jong-Woo
    • Journal of Oriental Neuropsychiatry
    • /
    • v.13 no.2
    • /
    • pp.121-147
    • /
    • 2002
  • This study was performed to evaluate the effects of Quibitang in the chronic mild stress(CMS) model of depression in rats. Chronic exposure to mild unpredictable stress was found to depress the consumption of sucrose solution in rats for 8 weeks. These CMS-treated rats were stratified into Quibitang gruop and saline group. And control rats were also stratified into Quibitang group and saline group. The change of the consumption of sucrose solution and the body weight were measured, and open field test, elevated startle response and plus maze test were performed, to investigate the anti-depression effect of Quibitang. The results were as follows: 1. The consumption of sucrose solution was significantly reversed in Quibitang-treated group at 9th, 11th, 12th week, but there was no significant change at 10th week 2. CMS schedule decreased body weight. CMS-treated groups showed decrease of body weight after 5 weeks. After 10 weeks, Quibitang group showed lower body weight than saline group in CMS-treated groups 3. In open field test, Quibitang group showed significant difference of locomotion, latency. 4. In elevated startIe test, Quibitang group showed no significant change of startle response. 5. In plus maze test, Quibitang group showed no significant change of plus maze-time and plus maze-error.

  • PDF

1$\times$16 DMUX Using Holographic Volume Gratings (홀로그래픽 부피격자를 이용한 1$\times$16 DMUX)

  • Lee, Kwon-Yeon;An, Jun-Won;Kim, Nam;Lee, Hyun-Jae;Seo, Wan-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.5
    • /
    • pp.31-38
    • /
    • 2000
  • We propose a new photorefractive demultiplexer(DMUX) which can select the 16 channel signal in WDM optical communication system using the wavelength selectivity and the demultiplexing property through multiple recording of holographic volume grating in photorefractive Fe-LiNbO$_{3}$ crystal. For the multiple writing of the 16 channels having uniform diffraction efficiency, the rotation multiplexing technique and the exposure time schedule are used. Designed DMUX has the 16 channels with 0.5nm spacing between 670nm and 677.5nm and the bandwidth of 0.16nm. From the experimental results, the diffraction efficiency of each channel is 8.3 $\pm$0.62%, the optical loss from fresnel reflection and absorption on the crystal is 0.4cm-1, the 3㏈ bandwidth is 0.16 $\pm$0.005nm and the channel spacing is 0.46~0.5nm.

  • PDF

Prevalence of Accident Occurrence Among Scientific Laboratory Workers of the Public University in Lebanon and the Impact of Safety Measures

  • Nasrallah, Inaam M.;El Kak, Assem K.;Ismaiil, Lina A.;Nasr, Rihab R.;Bawab, Wafa T.
    • Safety and Health at Work
    • /
    • v.13 no.2
    • /
    • pp.155-162
    • /
    • 2022
  • Background: Workers are exposed to several risks in academic laboratories due to the presence of potentially hazardous substances. The main objective of this study was to assess the prevalence of accident occurrence and associated risk factors among laboratory workers at the scientific laboratories of the public university in Lebanon and the impact of safety measures training and availability. Methods: In this observational study, a survey was conducted for one year in scientific laboratories at faculties of the public university. Results: Among the participants (N = 220), 45.0% have had accidents; the main cause was exposure to chemicals (73.7%) and more specifically by inhalation (45.4%). Females (85.9%) were more exposed to accidents than males. Laboratory workers with a master's degree, a full-time schedule, and more than ten years of experience were significantly more exposed to accidents (p < 0.05). A significant association was found between accident occurrence and training on management of hazardous products (p = 0.044), risks related to workplace (p = 0.030), eyewash and emergency shower (p < 0.001), first aid (p = 0.012), and facial protection availability (p = 0.019). In spite of the lack of safety culture and efficient training on laboratory safety, participants have shown a very good perception regarding safety measures to be applied in case of work accidents. Conclusion: Based on our findings, the prevalence of accident occurrence is elevated among lab workers at the public university. The impact of regular training on laboratory safety preventive measures is of great importance to ensure the efficiency of occupational health and safety in scientific laboratories.

Usefulness of CTAC Shift Revision Method of Artifact by Diaphragm in PET/CT (PET/CT 검사에서 횡격막에 의한 인공물의 CTAC Shift 보정방법의 유용성)

  • Ham, Jun Cheol;Kang, Chun Koo;Cho, Seok Won;Bahn, Young Kag;Lee, Seung Jae;Lim, Han Sang;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.71-75
    • /
    • 2013
  • Purpose: Currently, decrement revision using LDCT is used in PET/CT. But cold artifacts are often found in decrement revision image by mismatch between LDCT image and Emission image near diaphragm due to patient's respiration. This research studied reduction of cold artifact by patient's respiration using CTAC Shift among revision methods. Materials and Methods: From March to September in 2012, 30 patients who had cold artifacts by respiration were targeted using PET/CT Discovery 600 (GE Healthcare, MI, USA) equipment. Patients with cold artifacts were additionally scan in diaphragm area, and the image shown cold artifacts at whole body test were revised using CTAC Shift. Cold artifacts including image, additional scan image and CTAC Shift revision image were evaluated as 1~5 points with naked eye by one nuclear medicine expert, 4 radiotechnologists with over 5 year experience. Also, standard uptake value of 3 images was compared using paired t-test. Results: Additional scan image and CTAC Shift revision image received relatively higher score in naked eye evaluation than cold artifacts including image. The additional scan image and CTAC Shift revision image had high correlation as the results of ANOVA test of standard uptake value and did not show significant difference. Conclusion: When cold artifacts are appeared by patient's respiration at PET/CT, it causes not only patient inconvenience but troubles in test schedule due to extra radiation exposure and time consumption by additional scan. But if CTAC Shift revision image can be acquired with out additional scan, it is considered to be helped in exact diagnosis without unnecessary extra radiation exposure and additional scan.

  • PDF

Treatment of Carcinoma of the Uterine Cervix with High-Dose-Rate Intracavitary Irradiation using Ralstron (고선량률 강내조사를 사용한 자궁경부암의 치료)

  • Suh Chang Ok;Kim Gwi Eon;Loh John J.K.
    • Radiation Oncology Journal
    • /
    • v.8 no.2
    • /
    • pp.231-239
    • /
    • 1990
  • From May 1979 through December 1981 a total of 524 patients with carcinoma of the uterine cervix were treated by radiation therapy with curative intent. Among the 524 patients, 350 were treated with a high-dose-rate (HDR), remote-controlled, afterloading intracavitary irradiation (ICR) system using a cobalt source (Ralstron), and 168 patients received a low-dose-rate (LDR) ICR using a radium source. External beam irradiation with a total dose of 40-50 Gy to the whole pelvis followed by intracavitary irradiation with a total dose of 30-39 Gy in 10-13 fractions to point A was the treatment protocol. ICR was given three times a week with a dose of 3 Gy per fraction. Five-year actuarial survival rates in the HDR-ICR group were $77.6{\%}$ in stage IB (N=20), $68.2{\%}$ in stage II (N=182), and $50.9{\%}$ in stage III (N=148). In LDR-ICR group, 5-year survival rates were $87.5{\%}$ in stage IB (N=22), $66.3{\%}$ in stage II (N=91), and $55.4{\%}$ in stage III (N=52). Survival rates showed a statistically significant difference by stage, but there was no significant difference between the two ICR groups. Late bowel complications after radiotherapy were noted in $3.7{\%}$ of the HDR-ICR group and $8.4{\%}$ of the LDR-ICR group. There was no severe complication requiring surgical management. The incidence of bladder complications was $1.4{\%}$ in the HDR-ICR group and $2.4{\%}$ in the LDR-ICR group. The application of HDR-ICR was technically simple and easily performed on an outpatient basis without anesthesia, and the patients tolerated it very well. Radiation exposure to personnel was virtually nil in contrast to that of LDR-ICR. Within a given period of time, more patients can be treated with HDR-ICR because of the short treatment time. Therefore, the HDR-ICR system is highly recommended for a cancer center, particularly one with a large number of patients to be treated. In order to achieve an improved outcome, however, the optimum dose-fractionation schedule of HDR-ICR and optimum combination of intracavitary irradiation with external beam irradiation should be determined through an extensive protocol.

  • PDF