• Title/Summary/Keyword: exposure test

Search Result 1,962, Processing Time 0.03 seconds

The Characteristics of Heavy Metal(Zn, Pb) Accumulations in Paridae Nesting Material (박새과 조류의 둥지 재료 내 중금속(Zn, Pb) 축적특성 연구)

  • Kyeong-Tae Kim;Hyun-Jung Lee;Whee-Moon Kim;Won-Kyong Song
    • Korean Journal of Environment and Ecology
    • /
    • v.36 no.6
    • /
    • pp.566-574
    • /
    • 2022
  • Heavy metals are one of the dangerous pollutants that threaten urban biodiversity due to their accumulation over a long period without being decomposed in vivo. Accordingly, there is a need for biological monitoring to compare accumulation concentrations in living organisms according to the degree of heavy metal exposure to evaluate heavy metal contamination in the air in urban areas. This study aims to examine the possibility of using nesting materials as heavy metal monitoring samples and determine the effects of heavy metals on Paridae. We installed 54 artificial nest boxes in the research areas that included campus green spaces (14), urban forests (11), and urban parks (29) on a university campus in Cheonan City, Chungcheongnam Province. The birds' use rate of artificial nest boxes was 11/14 (78.57%) in campus green spaces, 8/11 (72.72%) in urban forests, and 6/29 (20.68%) in urban parks. Moss materials were collected from collected nests, and the heavy metal accumulation characteristics of each type of urban green space and the effects of heavy metals on the success of fledging of Paridae were compared through heavy metal analysis. The analysis showed that the average concentrations of zinc and lead were 228.08±209.62 ㎍/dry g and 17.67 ± 6.72 ㎍/dry g, respectively. There was no significant difference in zinc concentration for each type of urban green space (Kruskal-Wallis test, p-value=0.28), but lead concentration showed a significant difference (Kruskal-Wallis test, p<0.05*). Of the 21 Paridae, nests analyzed for heavy metals, fledging of birds was observed in 11 nests (52.38%). Fledging of birds observed in each urban green space type was 7 campus green spaces (77.78%), 6 in urban forests (85.71%), and 1 in urban park (20%), mainly in urban forests and green spaces on campus. Heavy metal concentrations were compared to check the effect of heavy metal accumulation on the successful fledging of Paridae, but there was no statistically significant difference (Zn: W=44, p-value=0.74, Pb: t=0.64676, df =7.2422, p-value=0.54). This study is a basic study using the nesting materials of Paridae as heavy metal monitoring samples, and it is determined that it can be used as basic data for non-invasive biological monitoring.

CT Examinations for COVID-19: A Systematic Review of Protocols, Radiation Dose, and Numbers Needed to Diagnose and Predict (COVID-19 진단을 위한 CT 검사: 프로토콜, 방사선량에 대한 체계적 문헌고찰 및 진단을 위한 CT 검사량)

  • Jong Hyuk Lee;Hyunsook Hong;Hyungjin Kim;Chang Hyun Lee;Jin Mo Goo;Soon Ho Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1505-1523
    • /
    • 2021
  • Purpose Although chest CT has been discussed as a first-line test for coronavirus disease 2019 (COVID-19), little research has explored the implications of CT exposure in the population. To review chest CT protocols and radiation doses in COVID-19 publications and explore the number needed to diagnose (NND) and the number needed to predict (NNP) if CT is used as a first-line test. Materials and Methods We searched nine highly cited radiology journals to identify studies discussing the CT-based diagnosis of COVID-19 pneumonia. Study-level information on the CT protocol and radiation dose was collected, and the doses were compared with each national diagnostic reference level (DRL). The NND and NNP, which depends on the test positive rate (TPR), were calculated, given a CT sensitivity of 94% (95% confidence interval [CI]: 91%-96%) and specificity of 37% (95% CI: 26%-50%), and applied to the early outbreak in Wuhan, New York, and Italy. Results From 86 studies, the CT protocol and radiation dose were reported in 81 (94.2%) and 17 studies (19.8%), respectively. Low-dose chest CT was used more than twice as often as standard-dose chest CT (39.5% vs.18.6%), while the remaining studies (44.2%) did not provide relevant information. The radiation doses were lower than the national DRLs in 15 of the 17 studies (88.2%) that reported doses. The NND was 3.2 scans (95% CI: 2.2-6.0). The NNPs at TPRs of 50%, 25%, 10%, and 5% were 2.2, 3.6, 8.0, 15.5 scans, respectively. In Wuhan, 35418 (TPR, 58%; 95% CI: 27710-56755) to 44840 (TPR, 38%; 95% CI: 35161-68164) individuals were estimated to have undergone CT examinations to diagnose 17365 patients. During the early surge in New York and Italy, daily NNDs changed up to 5.4 and 10.9 times, respectively, within 10 weeks. Conclusion Low-dose CT protocols were described in less than half of COVID-19 publications, and radiation doses were frequently lacking. The number of populations involved in a first-line diagnostic CT test could vary dynamically according to daily TPR; therefore, caution is required in future planning.

One-stop Evaluation Protocol of Ischemic Heart Disease: Myocardial Fusion PET Study (허혈성 심장 질환의 One-stop Evaluation Protocol: Myocardial Fusion PET Study)

  • Kim, Kyong-Mok;Lee, Byung-Wook;Lee, Dong-Wook;Kim, Jeong-Su;Jang, Yeong-Do;Bang, Chan-Seok;Baek, Jong-Hun;Lee, In-Su
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.33-37
    • /
    • 2010
  • Purpose: In the early stage of using PET/CT, it was used to damper revision but recently shows that CT with MDCT is commonly used and works well for an anatomical diagnosis. This hospital makes the accuracy and convenience more higher in the diagnosis and evaluate of coronary heart disease through concurrently running myocardial perfusion SPECT examination, myocardial PET examination with FDG, and CT coronary artery CT angiography(coronary CTA) used PET/CT with 64-slice. This report shows protocol and image based on results from about 400 coronary heart disease examinations since having 64 channels PET/CT in July 2007. Materials and Methods: An Equipment for this examination is 64-slice CT and Discovery VCT (DVCT) that is consisted of PET with BGO ($Bi_4Ge_3O_{12}$) scintillation crystal by GE health care. First myocardial perfusion SPECT with pharmacologic stress test to reduce waiting time of a patient and get a quick diagnosis and evaluation, and right after it, myocardial FDG PET examination and coronary CTA run without a break. One-stop evaluation protocol of ischemic heart disease is as follows. 1)Myocardial perfusion SPECT with pharmacologic stress: A patient is injected with $^{99m}Tc$-MIBI 10 mCi and does not have any fatty food for myocardial PET examination and drink natural water with ursodeoxcholic acid 100 mg and we get SPECT image in an hour. 2)Myocardial FDG PET: To reduce blood fatty content and to increase uptake of FDG, we used creative oral glucose load using insulin and Acipimox to according to blood acid content. A patient is injected with $^{18}F$-FDG 5 mCi for reduction of his radiation exposure and we get a gated image an hour later and get delay image when we need. 3) Coronary CTA: The most important point is to control heart rate and to get cooperation of patient's breath. In order to reduce a heart rate of him or her below 65 beats, let him or her take beta blocker 50 mg ~ 200 mg after a consultation with a doctor about it and have breath-practices then have the examination. Right before the examination, we spray isosorbide dinitrate 3 to 5 times to lower tension of bessel wall and to extension a blood wall of a patient. It makes to get better the shape of an anatomy. At filming, a patient is injected CT contrast with high pressure and have enough practices before the examination in order to have no problem. For reduction of his radiation exposure, we have to do ECG-triggered X-ray tube modulation exposure. Results: We evaluate coronary artery stenosis through coronary CTA and study correlation (culprit vessel check) of a decline between stenosis and perfusion from the myocardial perfusion SPECT with pharmacologic stress, coronary CTA, and can check viability of infarction or hibernating myocardium by FDG PET. Conclusion: The examination makes us to set up a direction of remedy (drug treatment, PCI, CABG) because we can estimate of effect from remedy, lesion site and severity. In addition, we have an advantage that it takes just 3 hours and one-stop in that all of process of examinations run in succession and at the same time. Therefore it shows that the method is useful in one stop evaluation of ischemic heart disease.

  • PDF

A Study on measurement of scattery ray of Computed Tomography (전산화 단층촬영실의 산란선 측정에 대한 연구)

  • Cho, Pyong-Kon;Lee, Joon-Hyup;Kim, Yoon-Sik;Lee, Chang-Yeop
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2003
  • Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

  • PDF

A study on lead exposure indices of male workers exposed to lead less than 1 year in storage battery industries (축전지 제조업에서 입사 1년 미만 남자 사원들의 연 노출 지표치에 관한 연구)

  • HwangBo, Young;Kim, Yong-Bae;Lee, Gap-Soo;Lee, Sung-Soo;Ahn, Kyu-Dong;Lee, Byung-Kook;Kim, Joung-Soon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.4 s.55
    • /
    • pp.747-764
    • /
    • 1996
  • This study intended to obtain an useful information for health management of lead exposed workers and determine biological monitoring interval in early period of exposure by measuring the lead exposure indices and work duration in all male workers (n=433 persons) exposed less than 1 year in 6 storage battery industries and in 49 males who are not exposed to lead as control. The examined variables were blood lead concentration (PBB), Zinc-protoporphyrin concentration (ZPP), Hemoglobin (HB) and personal history; also measured lead concentration in air (PBA) in the workplace. According to the geometric mean of lead concentration in the air, the factories were grouped into three categories: A; When it is below $0.05mg/m^3$, B; When it is between 0.05 and $0.10mg/m^3$, and C; When it is above $0.10mg/m^3$. The results obtained were as follows: 1. The means of blood lead concentration (PBB), ZPP concentration and hemoglobin(HB) in all male workers exposed to lead less than 1 year in storage battery industries were $29.5{\pm}12.4{\mu}g/100ml,\;52.9{\pm}30.0{\mu}g/100ml\;and\;15.2{\pm}1.1\;gm/100ml$. 2. The means of blood lead concentration (PBB), ZPP concentration and hemoglobin(HB) in control group were $5.8{\pm}1.6{\mu}g/100ml,\;30.8{\pm}12.7{\mu}g/100ml\;and\;15.7{\pm}1.6{\mu}g/100ml$, being much lower than that of study group exposed to lead. 3. The means of blood lead concentration and ZPP concentration among group A were $21.9{\pm}7.6{\mu}g/100,\;41.4{\pm}12.6{\mu}g/100ml$ ; those of group B were $29.8{\pm}11.6{\mu}g/100,\;52.6{\pm}27.9{\mu}g/100ml$ ; those of group C were $37.2{\pm}13.5{\mu}g/100,\;66.3{\pm}40.7{\mu}g/100ml$. Significant differences were found among three factory group(P<0.01) that was classified by the geometric mean of lead concentration in the air, group A being the lowest. 4. The mean of blood lead concentration of workers who have different work duration (month) was as follows ; When the work duration was $1\sim2$ month, it was $24.1{\pm}12.4{\mu}g/100ml$, ; When the work duration was $3\sim4$ month, it was $29.2{\pm}13.4{\mu}g/100ml$ ; and it was $28.9\sim34.5{\mu}g/100ml$ for the workers who had longer work duration than other. Significant differences were found among work duration group(P<0.05). 5. The mean of ZPP concentration of workers who have different work duration (month) was as follows ; When the work duration was $1\sim2$ month, it was $40.6{\pm}18.0{\mu}g/100ml$, ; When the work duration was $3\sim4$ month, it was $53.4{\pm}38.4{\mu}g/100ml$ ; and it was $51.5\sim60.4{\mu}g/100ml$ for the workers who had longer work duration than other. Significant differences were found among work duration group(P<0.05). 6. Among total workers(433 person), 18.2% had PBB concentration higher than $40{\mu}g/100ml$ and 7.1% had ZPP concentration higher than $100{\mu}g/100ml$ ; In workers of factory group A, those were 0.9% and 0.0% ; In workers of factory group B, those were 17.1% and 6.9% ; In workers of factory group C, those were 39.4% and 15.4%. 7. The proportions of total workers(433 person) with blood lead concentration lower than $25{\mu}g/100ml$ and ZPP concentration lower than $50{\mu}g/100ml$ were 39.7% and 61.9%, respectively ; In workers of factory group A, those were 65.5% and 82.3% : In workers of factory group B, those were 36.1% and 60.2% ; In workers of factory group C, those were 19.2% and 43.3%. 8. Blood lead concentration (r=0.177, P<0.01), ZPP concentration (r=0.135, P<0.01), log ZPP (r=0.170, P<0.01) and hemoglobin (r=0.096, P<0.05) showed statistically significant correlation with work duration (month). ZPP concentration (r=0.612, P<0.01) and log ZPP (r=0.614, P<0.01) showed statistically significant correlation with blood lead concentration 9. The slopes of simple linear regression between work duration(month, independent variable) and blood lead concentration (dependent variable) in workplace with low air concentration of lead was less steeper than that of poor working condition with high geometric mean air concentration of lead. The study result indicates that new employees should be provided with biological monitoring including blood lead concentration test and education about personal hygiene and work place management within $3\sim4$ month.

  • PDF

THE EFFECT OF IRRADIATION MODES ON POLYMERIZATION AND MICROLEAKAGE OF COMPOSITE RESIN (광조사 방식이 복합레진의 중합과 누출에 미치는 영향)

  • Park, Jong-Jin;Park, Jeong-Won;Park, Sung-Ho;Park, Ju-Myong;Kwon, Tae-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.158-174
    • /
    • 2002
  • The aim of this study was to investigate the effect of light irradiation modes on polymerization shrinkage, degree of cure and microleakage of a composite resin. VIP$^{TM}$ (Bisco Dental Products, Schaumburg, IL, USA) and Optilux 501$^{TM}$ (Demetron/Kerr, Danbury, CT, USA) were used for curing Filtek$^{TM}$ Z-250 (3M Dental Products, St. Paul., MN, USA) composite resin using following irradiation modes: VIP$^{TM}$ (Bisco) 200mW/$\textrm{cm}^2$ (V2), 400mW/$\textrm{cm}^2$ (V4), 600mW/$\textrm{cm}^2$ (V6), Pulse-delay (200 mW/$\textrm{cm}^2$ 3 seconds, 5 minutes wait, 600mW/$\textrm{cm}^2$ 30seconds, VPD) and Optilux 501$^{TM}$ (Demetron/Kerr) C-mode (OC), R-mode (OR). Linear polymerization shrinkage of the composite specimens were measured using Linometer (R&B, Daejeon, Korea) for 90 seconds for V2, V4, V6, OC, OR groups and for up to 363 seconds for VPD group (n=10, each). Degree of conversion was measured using FTIR spectrometer (IFS 120 HR, Bruker Karlsruhe, Germany) at the bottom surface of 2 mm thick composite specimens V2, Y4, V6, OC groups were measured separately at five irradiation times (5, 10, 20, 40, 60 seconds) and OR, VPD groups were measured in the above mentioned irradiation modes (n=5 each). Microhardness was measured using Digital microhardness tester (FM7, Future-Tech Co., Tokyo, Japan) at the top and bottom surfaces of 2mm thick composite specimens after exposure to the same irradiation modes as the test of degree of conversion(n=3, each). For the microleakage test, class V cavities were prepared on the distal surface of the ninety extracted human third molars. The cavities were restored with one of the following irradiation modes : V2/60 seconds, V4/40 seconds, V6/30 seconds, VPD , OC and OR. Microleakage was assessed by dye penetration along enamel and dentin margins of cavities. Mean polymerization shrinkage, mean degree of conversion and mean microhardness values for all groups at each time were analyzed using one-way ANOVA and Duncan's multiple range test, and using chi-square test far microleakage values. The results were as follows : . Polymerization shrinkage was increased with higher light intensity in groups using VIP$^{TM}$ (Bisco) : the highest with 600mW/$\textrm{cm}^2$, followed by Pulse-delay, 400mW/$\textrm{cm}^2$ and 200mW/$\textrm{cm}^2$ groups, The degree of polymerization shrinkage was higher with Continuous mode than with Ramp mode in groups using Optilux 501$^{TM}$ (Demetron/Kerr). . Degree of conversion and microhardness values were higher with higher light intensity. The final degree of conversion was in the range of 44.7 to 54.98% and the final microhardness value in the range of 34.10 to 56.30. . Microleakage was greater in dentin margin than in enamel margin. Higher light intensity showed more microleakage in dentin margin in groups using VIP$^{TM}$ (Bisco). The microleakage was the lowest with Continuous mode in enamel margin and with Ramp mode in dentin margin when Optilux 501$^{TM}$ (Demetron/Kerr) was used.

Image Evaluation and Exposure Dose with the Application of Tube Voltage and Adaptive Statistical Iterative Reconstruction of Low Dose Computed Tomography (저 선량 전산화단층촬영의 관전압과 적응식 통계적 반복 재구성법 적용에 따른 영상평가 및 피폭선량)

  • Moon, Tae-Joon;Kim, Ki-Jeong;Lee, Hye-Nam
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.261-267
    • /
    • 2017
  • The study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying filter back projection (FBP), the existing test method, and adaptive statistical iterative reconstruction (ASIR) with different values of tube voltage during the low dose computed tomography (LDCT). With the image reconstruction method as basis, chest phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of tube voltage (100 kVp, 120 kVp). For image evaluation, back ground noise, signal-noise ratio (SNR) and contrast-noise ratio (CNR) were measured, and, for dose assessment, CTDIvol and DLP were measured respectively. In terms of image evaluation, there was significant difference in ascending aorta (AA) SNR and inpraspinatus muscle (IM) SNR with the different amount of tube voltage (p < 0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120 kVp were 2.6 mGy with no-ASIR and 2.17 mGy with 20%-ASIR respectively, decreased by 0.43 mGy, and the values with 100 kVp were 1.61 mGy with no-ASIR and 1.34 mGy with 20%-ASIR, decreased by 0.27 mGy. In terms of DLP, the measured values with 120 kVp were $103.21mGy{\cdot}cm$ with no-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$ (about 16.7%), and the values with 100 kVp were $63.84mGy{\cdot}cm$ with no-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$ (about 16.7%). At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise.

A Small Outbreak of Measles in 2013: In a Single Hospital in Northern Gyeonggi-do (2013년 경기 북부 한 병원에서 확인된 소규모 홍역 유행)

  • Kim, Min Jae;Kim, So Hyun;Kim, Sung Un;Jang, Mi Jin;Lee, Hyun Seung;Kim, Young Hoon;Han, Ji Whan;Kim, Jin Tack;Jang, Pil Sang
    • Pediatric Infection and Vaccine
    • /
    • v.22 no.2
    • /
    • pp.63-68
    • /
    • 2015
  • Purpose: This study analyzed a small outbreak of measles at a single hospital located in northern Gyeonggi-do in 2013. Methods: We reviewed the medical records of measles patients at The Catholic University of Korea Uijeongbu St. Mary's Hospital from August to October, 2013. Results: Fifteen children were confirmed to have measles by RT-PCR and serum IgM test; 1 neonate, 11 infants, and 3 toddlers. None of the patients had received Measles-Mumps-Rubella vaccination. All patients showed B3 type in viral genotyping. Nine children (60%) had been exposed to measles during treatment for other diseases in the pediatric ward. Incubation period was between 8 and 15 days. Fever started at a median 10 days after exposure and persisted for a median of 8 days. Rash showed at a median 13 days after exposure. Respiratory complications were observed in 40% of patients. Diarrhea developed in 53% of patients. Conclusion: Although measles has been well-controlled due to the high rate of vaccination coverage, it is possible to have an outbreak at any given time, especially in infants. We must learn from this outbreak, and remain fully aware of the possibility of reemergence and provide proper management, including vaccination or immune globulin administration, to infants exposed to measles. Reevaluation of serum IgG titer of neonates, infants, and pregnant women may be the first step to prevent further outbreaks.

A CASE-ANALYSIS OF THE PSYCHIATRIC SEQUELAE IN ADOLESCENTS VICTIMIZED BY SCHOOL VIOLENCE (학교폭력 피해 청소년의 정신의학적 후유증에 관한 사례 연구)

  • Yook, Ki-Hwan;Lee, Ho-Bun;Noh, Kyung S.;Song, Dong-Ho
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.8 no.2
    • /
    • pp.232-241
    • /
    • 1997
  • The psychological problems following the experiences of school-violence could be more important than the physical problems. Victims could suffer from fear, depression, anger, lowered self-esteem, suicidal thought, and personality changes. To study the risk factors for school violence and the psychiatric problems after the experiences to school-violence provide us important informations to prevent and solve the problems of school violence. We examined clinical characteristics and psychosocial backgrounds of 13 adolescents who visited the psychiatric clinic after exposures to school violence from September, 1996 to May, 1997. The clinical data included intensity, motivations, durations, and methods of violence, psychiatric symptoms following exposure, findings of psychological test, and treatment course. The socioeconomic data included developmental characteristics of subjects, family characteristics, school life, and peer relationships. Of the 13 adolescents who experienced exposure to violence, 8 have experienced chronic psychiatric disturbances, 5 experienced transient psychiatric symptoms such as anxiety, depression, suicidal attempt who eventually returned to home and school life. Of the 8 adolescents who experienced chronic psychiatric disturbances, 4 experienced PTSD and depression lasting 3-6 months more, otherwise 4 showed converted features, such as aggressive behavioral disorder or perpetrator by strong compensatory effects after psychological shock. The subjects who have experienced chronic psychiatric disturbance have clinical characteristics such as physical or emotional abuse, physical illness or handicap, defects of ego functionings, and lack of family support. In summary, victims by school-violence manifested serious psychiatric disturbances, and they had clinically significant risk factors and some of them became perpetrators of school-violence.

  • PDF

The Differences of the Smoking Habit Between Emphysema and Chronic Bronchitis (폐기종과 만성기관지염의 흡연습관 차이)

  • Mun, Yeung-Chul;Yu, Sung-Keun;Park, Hye-Jung;Shin, Kyeong-Cheol;Chung, Jin-Hong;Lee, Kwan-Ho;Lee, Jung-Cheol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.6
    • /
    • pp.693-703
    • /
    • 2001
  • Background : Smoking is the most important and consistent determinant of the development and progression of COPD(Ed Note : Define COPD). The fact that cigarette smokers develop a different type of COPD, chronic bronchitis and emphysema, with different clinical and pathological aspects, suggests that the development of COPD has a relationship with other smoking-associated factors beyond just a simple smoking history. The aim of this was to analyze the smoking habits and history of patients with COPD and to evaluate the development of different types of COPD according to patient's smoking habits. Method : To evaluate the differences in the smoking patterns of patients with chronic bronchitis and emphysema, a pulmonary function test was conducted, and the smoking history and patterns was obtained through a smoking history questionnaire by a direct personal interview from 333 male cigarette smokers diagnosed with COPD, in the Yeungnam university medical center(190 patients diagnosed with chronic bronchitis, 143 patients diagnosed with emphysema). Result : The patients with emphysema smoked earlier and had a higher smoking history(ie, more packyears, more total amounts of smoked cigarette, and more deep inhalation and longer duration of plain cigarette exposure) than those with chronic bronchitis. The depth of inhalation was also significantly higher in the emphysema patients after taking into account age, cumulative cigarette consumption and the type of cigarette smoked. Conclusion : Emphysema was more associated with the increasing degree of inhalation as assessed by the depth of inhalation. A high alveolar smoke exposure may be a significant risk factor for the development of emphysema.

  • PDF