• Title/Summary/Keyword: exposure radius

Search Result 31, Processing Time 0.034 seconds

The Safety Evaluation of Expressway Geometries by Cross-sectional Analysis Techniques (횡단면 분석기법을 적용한 고속도로 기하구조 안전성 평가)

  • Seo, Im-Ki;Choi, Jong-Tae;Park, Je-Jin;Park, Shin-Hyoung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.417-426
    • /
    • 2015
  • The representative design elements of the road geometric structure are longitudinal slope, horizontal curve radius, super elevation, and transition curve. According to the function of a road, the design standards of these elements is applied by diverse combinations of them. This study divided expressway into homogeneous segments based on longitudinal slope and horizontal curve radius. And then, data required for analysis were matched to each segment, and the safety performance function was built by using the established data. crash modification factors which can explain traffic accident exposure rate were calculated. When the threshold value of horizontal curve radius R=1,000 m was set to 1.0, the crash modification factors at R=300 m was calculated as 1.33, which means that the accident exposure rate is increased by 33%. When the threshold value of the longitudinal slope 0% was set to 1.0, the crash modification factors demonstrated that the accident exposure rate decreases on the upward slope and the accident exposure rate increases on the downward slope. The results of this study can be used as basic information in the design of expressway geometries during the improvement or the construction of expressways.

Exposure-Limit Distance as a Safety-Indicating Parameter of a High-Intensity Flash Source (고광도 섬광의 안전지표로서 노출제한거리)

  • Park, Seung-Man;Kim, Sang-Wook
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.1
    • /
    • pp.16-21
    • /
    • 2017
  • A systematic understanding of the effects of high-intensity flash sources on the human eye is strongly needed, not only for proper use of the sources, but for human eye health. In this study, the exposure-limit distance (ELD), indicating the minimal safe distance in case of seeing by chance a high-intensity flash, is proposed. The optical procedures to determine the ELD of a high-intensity flash are clarified, and the dependence of ELD on its parameters such as luminous intensity, duration, and radius of a flash are thoroughly investigated. From this investigation it is obvious that, while being weakly dependent on duration, the ELD is nearly proportional to the luminous intensity and the radius of a flash. The proposed ELD as an intuitive safety-indicating parameter is more useful and intuitive than the other characteristic parameters of a high-intensity flash. The ELD is expected to be an essential parameter as a safety indicator, to characterize the performance of a high-intensity flash and to promote the safety of the human eye.

A Study of Explosion Risk Assessment for Designation of Dangerous Goods Transshipment Pier at Ulsan Port (울산항 위험물 환적부두 지정을 위한 폭발 위험성 평가에 관한 연구)

  • Kang, Min-Kyoon;Lee, Yun-Sok;Ahn, Young-Joong
    • Journal of Navigation and Port Research
    • /
    • v.45 no.3
    • /
    • pp.109-116
    • /
    • 2021
  • The explosion of a chemical tanker ship during cargo transshipment via double-banking at Ulsan Port, resulted in major damage including fires involving nearby ships. As a follow-up measure to prevent the recurrence of similar accidents, the 'Safety Management of Dangerous Goods in Port' was established, and the designation of a transshipment pier for dangerous goods is required given the risk of explosion and the impact on major facilities in the port. This study evaluated the Fire & Explosion Index of major transshipment cargoes in Ulsan Port to design a transshipment pier based on the Explosion Risk Assessment. Based on the results of Fire & Explosion Index evaluation of styrene monomer and benzene, severe explosion risk was confirmed, and the exposure radius was calculated. Based on the results of the exposure radius, the risk range for each major pier was calculated, and 12 terminals were proposed as transshipment pier candidates considering port facilities, surrounding dangerous facilities, and residential aspects. Since the results of the study suggest transshipment piers based on the risk radius alone, maritime traffic safety, pier and mooring facilities, safety facilities and accessibility for emergency response should be considered comprehensively to designate actual transshipment piers.

Comparative Study of Coupling Factors for Assessment of Low-Frequency Magnetic Field Exposure

  • Shim, Jae-Hoon;Choi, Min-Soo;Jung, Kyu-Jin;Kwon, Jong-Hwa;Byun, Jin-Kyu
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.516-523
    • /
    • 2016
  • In this paper, coupling factors are calculated based on numerical analysis in order to assess various non-uniform low-frequency magnetic field exposure situations. Two types of non-uniform magnetic field sources are considered; circular coil and parallel wires with balanced currents. For each magnetic field source, source current values are determined so that reference magnetic field magnitude can be measured at the specified point on the human model. Various exposure situations are investigated by changing parameters such as the distance between source and human model, radius of circular coil, and the gap between parallel wires. For equivalent human models, prolate spheroid model and simplified human model from IEC 62311 standard are used. The calculated coupling factor values are compared with those obtained by 2D uniform disk human model, and the dependence of coupling factor on the choice of equivalent human model is analyzed.

Hybrid UV Lithography for 3D High-Aspect-Ratio Microstructures (하이브리드 자외선 노광법을 이용한 3차원 고종횡비 미소구조물 제작)

  • Park, Sungmin;Nam, Gyungmok;Kim, Jonghun;Yoon, Sang-Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.8
    • /
    • pp.731-736
    • /
    • 2016
  • Three-dimensional (3D) high-aspect-ratio (HAR) microstructures for biomedical applications (e.g., microneedle, microadhesive, etc.) are microfabricated using the hybrid ultraviolet (UV) lithography in which inclined, rotational, and reverse-side UV exposure processes are combined together. The inclined and rotational UV exposure processes are intended to fabricate tapered axisymmetric HAR microstructures; the reverse-side UV exposure process is designed to sharpen the end tip of the microstructures by suppressing the UV reflection on a bottom substrate which is inevitable in conventional UV lithography. Hybrid UV lithography involves fabricating 3D HAR microstructures with an epoxy-based negative photoresist, SU-8, using our customized UV exposure system. The effects of hybrid UV lithography parameters on the geometry of the 3D HAR microstructures (aspect ratio, radius of curvature of the end tip, etc.) are measured. The dependence of the end-tip shape on SU-8 soft-baking condition is also discussed.

Exposure Assessment for Toxic Hepatitis Caused by HCFC-123

  • Kim, Ki-Woong;Park, Hae Dong;Jang, Konghwa;Ro, Jiwon
    • Safety and Health at Work
    • /
    • v.9 no.3
    • /
    • pp.356-359
    • /
    • 2018
  • This case report attempts to present a case of acute toxic hepatitis in fire extinguisher manufacturing workers exposed to 2,2-dichloro-1,1,1-trifluoro-ethane (HCFC-123) in August 2017 in Korea. Twenty-two-year-old male workers were exposed to HCFC-123 for 1.5 hours one day and for 2.5 hours the other day, after which one worker died, and the other recovered after treatment. The workers were diagnosed with acute toxicity of hepatitis. However, exposure levels of HCFC-123 were not known with no work environment measurement done. Therefore, this study was conducted to estimate the exposure concentration of HCFC-123 via a job simulation experiment. In the simulation, the HCFC-123 exposure concentration was measured with the same working practice and working time as with the workers aforementioned. As a result, the workers who infused HCFC-123 into storage tanks were estimated to be exposed to HCFC-123 at a concentration of $20.65{\pm}10.81ppm$, and a mean concentration of area samples within a working radius were estimated as $70.30{\pm}18.10ppm$. Valve assembly workers working on valves of a fire extinguisher filled with HCFC-123 were exposed to HCFC-123 at concentrations of $91.65{\pm}4.03ppm$ and $115.55{\pm}7.28ppm$, respectively, in the simulation, and area samples simulated within the working radius were also found to be high with concentrations of $122.75{\pm}91.15ppm$ and $126.80{\pm}60.25ppm$, respectively. Nitrogen gas packing workers, who did not handle HCFC-123 directly, were exposed to the agent at a concentration of $71.80{\pm}8.49ppm$. These results suggest that exposure to HCFC-123 at high concentrations for 1.5-2.5 hours caused acute toxic hepatitis in two workers.

The Effects of Computer Game Exposure on Musculoskeletal Pathological Symptoms in Adolescents

  • Chae, Woen-Sik;Jung, Jae-Hu
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.1
    • /
    • pp.55-60
    • /
    • 2018
  • Objective: This study aimed to analyze the effects of computer game exposure on pathological musculoskeletal symptoms in adolescents. Method: This study included 10 male junior high school students who used computers less than 3 times a week for 1 hr per day. The subjects were asked to play computer games for 4 hr. Magnetic resonance imaging of the hand and wrist, from the distal radius and ulnar head to the distal phalanges, and radiography of the cervical vertebrae were performed before and after playing computer games. For each dependent variable, a paired t-test was performed to identify significant changes before and after a 4-hr active computer game (p<.05). Results: The horizontal diameters of the flexor tendons in the index and middle fingers were significantly reduced after playing computer games. The horizontal diameters of the flexor tendons of other fingers did not show any significant differences, but there was a tendency toward a decrease after playing computer games. There was no significant change in the cervical lordosis angle before and after playing computer games. However, the cervical lordosis angle was relatively decreased. Conclusion: The results of this study showed that computer game exposure had direct and indirect effects on morphological changes of flexor tendons. In addition, playing computer games for long periods of time can have a negative effect on normal functioning of the musculoskeletal system, with the possible development of abnormalities. However, computer game exposure in adolescents cannot be decisively identified as a factor causing pathological symptoms, based on the results of this study alone. Thus, longterm longitudinal studies on the overall musculoskeletal system are necessary.

Existing Population Exposure Assessment Using PM2.5 Concentration and the Geographic Information System (지리정보시스템(GIS) 및 존재인구를 이용한 초미세먼지(PM2.5) 노출평가)

  • Jaemin, Woo;Gihong, Min;Dongjun, Kim;Mansu, Cho;Kyeonghwa, Sung;Jungil, Won;Chaekwan, Lee;Jihun, Shin;Wonho, Yang
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.6
    • /
    • pp.298-305
    • /
    • 2022
  • Background: The concentration of air pollutants as measured by the Air Quality Monitoring System (AQMS) is not an accurate population exposure level since actual human activities and temporal and spatial variability need to be considered. Therefore, to increase the accuracy of exposure assessment, the population should be considered. However, it is difficult to obtain population data due to limitations such as personal information. Objectives: The existing population defined in this study is the number of people in each region's grid. The purpose is to provide a methodology for evaluating exposure to PM2.5 through existing population data provided by the National Geographic Information Institute. Methods: The selected study period was from October 26 to October 28, 2021. Using PM2.5 concentration data measured at the Sensor-based Air Monitoring Station (SAMS) installed in Guro-gu and Wonju-si, the concentration for each grid was estimated by applying inverse distance weights through QGIS version 3.22. Considering the existing population, population-weighted average concentration (PWAC) was calculated and the exposure level of the population was compared by region. Results: The outdoor PM2.5 concentration as measured through the SAMS was high in Wonju-si on all three days. Wonju-si showed an average 22% higher PWAC than Guro-gu. As a result of comparing the PWAC and outdoor PM2.5 concentration by region, the PWAC in Guro-gu was 1~2% higher than the observed value, but it was almost the same. Conversely, observations of Wonju-si were 10.1%, 11.3%, and 8.2% higher than PWAC. Conclusions: It is expected that the Geographic Information System (GIS) method and the existing population will be used to evaluate the exposure level of a population with a narrow activity radius in further research. In addition, based on this study, it is judged that research on exposure to environmental pollutants and risk assessment methods should be expanded.

Analysis of the Distributional Effects of Radioactive Materials on External Gamma Exposure (방사성물질의 분포특성에 따른 외부 감마피폭해석)

  • Han, Moon-Hee;Kim, Eun-Han;Suh, Kyung-Suk;Hwang, Won-Tae;Choi, Young-Gil
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.211-218
    • /
    • 1998
  • The distributional effects of radioactive materials on external gamma exposure have been analyzed. An approximate method for estimating external gamma dose given from an arbitrary distribution of radioactive material has been developed. The minimum gamma exposure given from a point source is shown at 0.07 MeV if the source to receptor distance is shorter than 10 m. But if the receptor to point source distance is longer than 20 m, gamma exposure rate increases monotonously according to the average gamma energy. For the analysis of the effects of volume source, we estimated the gamma dose given from different size of hemisphere in which radioactive materials are distributed uniformly. When the radius of hemisphere is longer than 40 m, external gamma dose rate increases monotonously. The gamma dose rate given from the radioactive materials deposited on the ground shows the minimum value at 0.07 MeV in any case. The analysis shows that external gamma exposure is strongly dependent on the distribution of radioactive materials in the environment and gamma energy.

  • PDF

Spatial Dose Distribution for Diagnostic X-ray Examination within X-ray Room using the MCNPX Program (MCNPX 프로그램을 통한 일반 X선 검사 시 검사실 내 공간선량분포)

  • Lee, Dong-yeon;Lee, Jin-soo
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.298-306
    • /
    • 2015
  • This study is the material of the additional filter(Cu, Ni, CaWO4, Gd+Ba) being used when the diagnosis X-ray was varied to evaluate the spatial dose distribution accordingly. And it suggest to find a suitable material. Experiments using MCNPX program based on the Monte Carlo simulation method was carried out by selecting the chest and abdomen taken. As a result, each material per dose, the average scatter dose is approximately 62%, 100 cm radius of the point of the simulated body surface exposure dose and 50 cm radius centered on the point average about 47%. It is determined that an Al material is currently available in accordance with the result to be replaced by Cu, Ni material is sufficient. With just the thickness due to the difference in the atomic number and density adjusted to be about one-tenth of the Al it will be suitable.