The Comparative Analysis of Exposure Conditions between F/S and C/R System for an Ideal Image in Simple Abdomen (복부 단순촬영의 이상적 영상구현을 위한 F. S system과 C.R system의 촬영조건 비교분석)

  • Son, Sang-Hyuk;Song, Young-Geun;Kim, Je-Bong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.37-43
    • /
    • 2007
  • 1. Purpose : This study is to present effective exposure conditions to acquire the best image of simple abdomen in Film Screen (F.S) system and Computed Radiography (C.R) system. 2. Method : In the F.S system, while an exposure condition was fixed as 70kVp, images of a patients simple abdomen were taken under the different mAs exposure conditions. Among these images, the best one was chosen by radiologists and radiological technologists. In the C.R system, the best image of the same patient was acquired with the same method from the F.S system. Both characteristic curves from F.S system and C.R system were analyzed. 3. Results : In the F.S system, the best exposure condition of simple abdomen was 70kVp and 20mAs. In the CR system, with the fixed condition at 70kVp, the image densities of human organs, such as liver, kidney, spleen, psoas muscle, lumbar spine body and iliac crest, were almost same despite different environments (3.2mAs, 8mAs, 12mAs, 16mAs and 20mAs). However, when the exposure conditions were over or under (below) 12mAs, the images between the abdominal wall and the directly exposed part became blurred because the gap of density was decreased. In the C.R system, while the volume of mAs was decreased, an artifact of quantum mottle was increased. 4. Conclusion : This study shows that the exposure condition in the C.R system can be reduced 40% than in the F.S system. This paper concluded that when the exposure conditions are set in CR environment, after the analysis of equipment character, such as image processing system(EDR : Exposure Data Recognition processing), PACS and so on, the high quality of image with maximum information can be acquired with a minimum exposure dose.

  • PDF

Comparison of Gold Biosensor Combined with Light Microscope Imaging System with ELISA for Detecting Salmonella in Chicken after Exposure to Simulated Chilling Condition

  • Mi-Kyung Park
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.2
    • /
    • pp.228-234
    • /
    • 2023
  • In this study, the performance of a gold biosensor combined with light microscope imaging system (GB-LMIS) was comparatively evaluated against enzyme-linked immunosorbent assay (ELISA) for detecting Salmonella under simulated chilling condition. The optimum concentration of antiSalmonella polyclonal antibodies (pAbs) was determined to be 12.5 and 100 ㎍/ml for ELISA and GBLMIS, respectively. GB-LMIS exhibited a sufficient and competitive specificity toward three tested Salmonella among only. To mimic a real-world situation, chicken was inoculated with Salmonella cocktail and stored under chilling condition for 48 h. The overall growth of Salmonella under chilling condition was significantly lower than that under non-exposure to the chilling condition (p < 0.05). No significant differences in bacterial growth were observed between brain heart infusion and brilliant green broth during the enrichment period (p > 0.05). Finally, both GB-LMIS and ELISA were employed to detect Salmonella at every 2-h interval. GB-LMIS detected Salmonella with a competitive specificity by the direct observation of bacteria on the sensor using a charge-coupled device camera within a detection time of ~2.5 h. GB-LMIS is a feasible, novel, and rapid method for detecting Salmonella in poultry facilities.

Compound Effect of Persistent Organic Pollutants on the Mortality of Marine Copepods (유기오염물질의 복합독성이 요각류 사망률에 미치는 영향)

  • Kang, Jung-Hoon;Kim, Woong-Seo
    • Ocean and Polar Research
    • /
    • v.28 no.1
    • /
    • pp.45-56
    • /
    • 2006
  • This study investigated primarily the toxic effects of bis(tributyltin)oxide (TBT) and DDT (Dichlorodiphenyltrichloroethane) on the mortality of adult Acartia omorii and barnacle nauplii as well as the hatching rate of A. omorii. Subsequently, compound effects of TBT and DDT on the mortality of immature copepods were tested in order to assess whether or not synergistic influence existed in the mixture of sublethal concentration of two pollutants. Mortality of adult A. omorii increased as exposure concentration of DDT increased in the range of from 0.0001 to 1ppm. Egg hatching rate of the copepod showed no distinctive difference in the range between 0.1 and 10ppm, while barnacle nauplii showed abnormal motility of their appendages in the range of 0.0001 to 1 ppm. Mortality of adult A. omorii increased as TBT concentration increased within the range of 1 and 10 ppb, whereas egg hatching rate of the copepod showed no linear response to the same exposure range. Moreover, copepod nauplii were almost motionless even though copepod eggs hatched under the exposure condition of TBT $(0{\sim}10 ppb)$ and DDT $(0{\sim}10 ppm)$, respectively, suggesting that the nauplii are hard to develop into adult stage. On the basis of the sublethal concentration less than the 24-h $LC_{50}$, 0.001 ppm (DDT) and 2 ppb (TBT) were selected to confirm the compound effects of two pollutants on the mortality of immature copepods. Mortality of immature copepods under the condition of mixture of the two pollutants was higher than that in the single exposure condition. This result seems to indicate that synergistic effects of sublethal toxicants can make a more hazardous effect on the survival of immature copepods even though the concentration of single toxicant is not lethal to copepods in the marine environment.

The research for the enhancement of depth of focus by elliptical polarization illumination(EPI) (타원편광 조명에 의한 초점심도 향상에 관한 연구)

  • 박정보;김기호;이성묵
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.3
    • /
    • pp.146-150
    • /
    • 1998
  • To enhance the resolution and the depth of focus of the patterns whose size reaches the optical resolution limits, the various imaging methods are being tried. Generally in the linear polarization illumination methods, the contrast gap exists between TE mode TM mode according to the pattern direction. However, through the previous research, the elliptical polarization illumination(EPI) method was proposed to overcome this contrast gap. In this research, we investigated the optimal polarization condition to be able to enhance the depth of focus(DOF) for the optional mask which is containing the opposite direction patterns by applying the various polarization conditions including EPI. The DOF according to each polarization condition was obtained by ED-Tree(Exposure-Defocus Tree) for the given exposure dose and CD error boundaries. As the result, we can ascertain th effect of EPI for the enhancement of DOF in some condition of optical system.

  • PDF

A Study on Dose Reduction Method according to Slice Thickness Change using Automatic Exposure Controller and Manual Exposure in Intervention (인터벤션에서 자동노출제어장치와 수동노출 사용 시 두께 변화에 따른 선량감소 방안 연구)

  • Hwang, Jun-Ho;Jung, Ku-Min;Choi, Ji-An;Kim, Hyun-Soo;Lee, Kyung-Bae
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.115-122
    • /
    • 2018
  • We aims to perform comparative analysis on the dose area and image qualities varying on the slice thickness when using Automatic Exposure Controller (AEC) and manual exposure; thus, it wants to suggest a measure to reduce exposure dose by setting the optimal examination condition for each slice thickness. The method was to set the thickness as Thin, Normal, and Heavy adult and evaluate the dose area, spatial resolution, low contrast resolution, Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) according to each slice thickness by using the AEC and the manual exposure controller. The dose area according to each slice thickness all increased both when using the AEC and the manual exposure. However, the manual exposure showed lower dose area product than the AEC. Spatial resolutions and low contrast resolutions were all observed to be higher than the evaluation standard. Also, the SNR and CNR of each thickness all increased when using the AEC. When using the manual exposure, SNR and CNR increased in all cases other than the Heavy Adult. Consequently, the Thin and Normal Adult showed dose reduction about 2 times when using the manual exposure controller, while ensuring the image quality. Heavy adult was able to maintain good image quality by using AEC.

Analysis of the cause by Pre Exposure Tube Voltage and Actual Exposure Tube Voltage deviation in Mammography Examination (유방 촬영검사에서 사전조사 관전압과 실제조사 관전압 편차에 따른 원인 분석)

  • Cho, Ji-Hwan;Lee, Hyo-Yeong;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.79-85
    • /
    • 2017
  • The purpose of this study is to investigate the cause analysis according to the difference between the pre exposure tube voltage and actual exposure tube voltage in mammography in connection with breast pressure thickness, breast size and body mass index and to find the improvement. The study tracked 377 women age 40 and older among the mammography examiners conducted by the National Health Insurance Corporation. It was analyzed that breast pressure thickness, breast size and body mass index according to the difference between the pre exposure tube voltage and actual exposure tube voltage among the parameters of dose report been sent to the picture archiving communication system with reference to the image with cranio-caudal projection in mammography. As are result, it shows that the thicker the breast thickness, smaller the breast size and lower body mass index, the higher the difference of tube voltage. In conclusion, the minimum tube voltage of mammography machine should be reset in order to set the tube voltage according to breast pressure thickness and breast size that are suitable for our country in mammography, in addition, it was considered that radiologist should make an effort to reduce radiation exposure and make a good quality image with reducing the difference of mammography condition by making a correct exposure condition in case of examining the patients with thin breast pressure and small breast size.

Suggestion of The Manual Exposure Condition Guideline for Reducing Patient Dose in Digital Breast Tomosynthesis (디지털 유방단층촬영의 피폭선량 경감을 위한 수동 촬영조건의 가이드라인 제시)

  • Hong, Eun-Ae;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.483-491
    • /
    • 2016
  • The conditions after exposure to digital mammography and digital breast tomosynthesis were analyzed. The examinations for the ACR phantom were done using manual exposure, not auto exposure, to examine image discrimination and patient dose. As a result, the following results were derived: In the CC exposure, the kVp was 2kVp higher while mAs decreased to 58.6% for the 3D tomography. Such result showed an approximate decrease of 60mAs. At that time, the patients' Average Glandular Dose (AGD) was 1.65mGy in 2D and 1.87mGy in 3D; thus, AGD of 3D was shown to have about 1.13times higher. The result of the manual exposure revealed a reduced mAs of up to 80%; there was no effect in the assessment standard in terms of image discrimination, resulting in more than 10 points. When mAs was reduced to 80% in the manual exposure for ACR phantom, AGD was decreased to 0.66mGy. The diagnostic values of images were maintained and patients dose was reduced in the manual exposure in the AEC condition for 3D. Since the use of 3D has recently increased, using the manual exposure has been recommended in this study to improve the diagnostic value, while, simultaneously reducing patients dose.

Effect of Very Low Levels of Lead in Diet and Exposure Time on the Accumulation and Distribution of Lead in Rat Organs (식이와 함께 섭취시킨 미량의 납 수준과 납 섭취기간이 납의 체내 축적 및 분포에 미치는 영향)

  • 이명희
    • Journal of Nutrition and Health
    • /
    • v.27 no.1
    • /
    • pp.12-22
    • /
    • 1994
  • Effects of very low level of lead in diet and exposure time on the accumulation and distribution in organs and tissues was investigated with growing rats. 21 days old Sprague-Dawley rats were exposed to lead for 7, 14 and 21 days by feeding of 0.03, 0.42, 0.92 and 1.46mg/kg Pb as Pb-acetate containing diet, respectively. Lead concentrations in blood, liver, kidney and bone exhibit a linear relationship with lead levels in diet. After 7 days of exposure, the greatest dose dependent accumulation of lead was found in kidney and followed in bone. However, after 14 and 21 days, the dose dependent accumlation of lead in bone was about two fold greater than that in kidney. The accumulation of lead in liver and blood was relatively low. As continuous exposure to lead, the concentrations of lead in liver, kidney, blood and intestinal tracts were rather not increased with exposure time. However, bone lead concentration was increased with exposure time by feeding of 0.92 and 1.46mg/kg Pb in diet, but not 0.42mg/kg. The lead concentration in gastrointestinal tracts tends also to increasing with lead levels in diet after 7 and 14 days of exposure. However, by 21 days of exposure the lead concentration revealed relatively constant value regardless of the dietary lead levels. It is concluded that the binding capacity of the lead in blood, liver, kidney and bone seems to be increased with increasing lead levels in diet. The lead concentration in these organs, with the exception of the lead in bone, seems, however, to be standing under steady state regulation by continued exposure with the same dietary lead level. Therefore, by chronic exposure condition with environmental relevant lead level bone might be a principle targe organ for lead and blood lead repesents better the current lead exposure than the lead body burden.

  • PDF

$PM3.5/NO_2$ Concentration Ratio in Roadside and Exposure Assessment of Shoes Repairmen in Seoul (서울시 도로변의 $PM3.5/NO_2$ 농도비 및 구두수선대 근로자의 노출평가)

  • 배현주;양원호;김나리;정문호
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.4
    • /
    • pp.21-30
    • /
    • 2001
  • Vehicles, especially diesel-using, are a major source of airborne particulate matter(PM), nitrogen dioxide($NO_2$) and so on in metropolitan cities such as Seoul. Therefore workers, who are mainly merchants, near roadside may be highly exposed to air pollutants from exhausted emissions of vehicles. This means that occupational type and location can affect the workers'health by exposure to outdoor pollutions of ambient as well as indoor pollutions of working condition, respectively. In this study, we simultaneously measured the PM3.5 and $NO_2$concentrations in indoor and outdoor of shoes repair shops in Seoul, which were generally located at roadside in Korea. Shoes repairmen were highly exposed to PM3.5 and $NO_2$ both indoor and outdoor of repair shops comparing with other sub-population groups. High exposure to air pollutants for shoes repairmen was considered to be outdoor source from exhausted emission of vehicles and indoor source from working condition. The $PM3.5/NO_2$ concentration ratio was $1.17{\pm}$0.59 in roadside, of which ratio was higher 7han ratios of other studies. This result suggested that major air pollutant in Seoul was fine particle. Also, this PM3.5 to $NO_2$ ratio will be used in environmental exposure and risk assessment by estimation of PM3.5 concentration as measuring the only $NO_2$ concentration with small and accurate $NO_2$ passive sampler.

  • PDF

AN EXPERIMENTAL STUDY ON THE READABILITY OF THE DIGITAL IMAGES IN THE FURCAL BONE DEFECTS (디지털영상의 치근이개부 골손실 판독효과에 관한 실험적 연구)

  • Oh Bong-Hyeon;Hwang Eui-Hwan;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.363-373
    • /
    • 1995
  • The aim of this study was to evaluate and compare observer performance between conventional radiographs and their digitized images for the detection of bone loss in the bifurcation of mandiblar first molar. One dried human mandible with minimal periodontal bone loss around the first molar was selected and serially enlarged 17 step defects were prepared in the bifurcation area. The mandible was radiographed with exposure time of 0.12, 0.20, 0.25, 0.32, 0.40, 0.64 seconds, after each successive step in the preperation and all radiographs were digitized with IBM-PC/32 bit-Dx compatible, video camera (VM-S8200, Hitachi Co., Japan), and color monitor(Multisync 3D, NEC, Japan). Sylvia Image Capture Board for the ADC(analog to digital converter) was used. The obtained results were as follows: 1. In the conventional radiographs, the mean score of the readability was higher at the condition of exposure time with 0.32 second. Also, as the size of artificial lesion was increased, the readability of radiographs was elevated (P<0.05). 2. In the digital images, the mean score of the readability was higher at the condition of exposure time with 0.40 second. Also, as the size of artificial lesion was increased, the readability of digital images was elevated(P<0.05). 3. At the same exposure time, the mean scores of readibility were mostly higher in the digitized images. As the exposure time was increased, the digital images were superior to radiographs in readability. 4. As the size of lesion was changed, the digital images were superior to radiographs in detecting small lesion. 5. The coefficient of variation of mean score has no significant difference between digital images and radiographs.

  • PDF