• Title/Summary/Keyword: experimental modules

Search Result 603, Processing Time 0.029 seconds

An Experimental Study on the Supplemental Cooling and Heating Performance Using 1 kW Thermoelectric Module for Vehicle (열전모듈을 이용한 자동차용 1 kW급 보조 냉난방 시스템의 성능에 관한 실험적 연구)

  • Lee, Dae-Woong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.224-230
    • /
    • 2014
  • The purpose of this paper is to investigate the performance of supplemental cooling and heating system equipped with the 1 kW thermoelectric module. The system consist of 96 thermoelectric modules, heat sink with louver fin and water cooling jacket which is attached on the hot side of the thermoelectric module. The cooling and heating performance test of the thermoelectric system is conducted with various conditions, such as intake voltage, air inlet temperature, air flow volume, water inlet temperature and water flow rate at calorimeter chamber in consideration of environmental conditions in realistic vehicle drive. The experimental results of a thermoelectric system shows that the cooling capacity and COP is 1.03 kW, and 1.0, and heating capacity and COP is 1.53 kW, and 1.5 respectively.

Fatigue Behavior of GFRP Bridge Deck in the Transverse Direction (GFRP 바닥판의 약축방향 피로거동 특성)

  • Zi, Goang-Sseup;Jung, Jin-Kyu;Kim, Byung-Min;Hwang, Yoon-Koog;Lee, Young-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.393-398
    • /
    • 2007
  • Fatigue Behavior of a GFRP bridge deck consisting of rectangular unit modules is studied by an experimental method. The experiment focuses on how the damage in the transverse direction influence the overall behavior of the deck It is proposed filling the space in each module with a soft foam. Using the recent experimental data, the fatigue behavior is discussed. If the space of the deck is filled with the foam, the fatigue life of the deck was increased about 1,000 times for the same level of the stress variation as the reference deck not filled.

  • PDF

The Experimental Study on Cooling-Heating System Using Thermoelectric Module and Parallel Flow Type Oscillating Heat Pipe (열전소자와 PF Type 진동형 히트파이프를 이용한 냉.난방기에 관한 연구)

  • 김종수;임용빈;조원호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.8
    • /
    • pp.741-747
    • /
    • 2004
  • The purpose of this study was to develop a cooler/heater using a thermoelectric module combined with a parallel flow type oscillating heat pipe with R-142b as a work ing fluid. The experiment was performed for 16 thermoelectric modules (6 A/15 V, size: 40${\times}$40${\times}$4 mm), varying design parameters of the heat pipe (inclination angle, working fluid charging ratio, etc) . Experimental results indicate that the optimum charging ratio and the inclination angle of the parallel flow type oscillating heat pipe were 30% by volume and 30%, respectively. The maximum cooler/heater capacity were 479W (COP : 0.47) and 630W (COP : 0.9), respectively.

A Development of Agent-Based IEDs for Integration Control of Building Microgrid in Smart Green Building (그린빌딩에서의 빌딩마이크로그리드 통합제어를 위한 에이전트용 IED 개발)

  • Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.10
    • /
    • pp.35-43
    • /
    • 2012
  • In this paper, a development of agent-based IEDs(Intelligent electronic devices) for integration control of building microgrid in smart green building are proposed. To manage and control this complex energy system of smart green buildings, multi-agent system based networks is needed. Thus, several IEDs for utilizing multi-agent system are developed and modified for the their verification of performance as agent modules functions in the integrated experimental equipment. The good performance of these IED agents are verified from experimental results obtained from seamless bi-directional communication by SOAP/XML protocol between PC agent and IED agent.

Dynamic Performance Analysis of Unified Power Quality Conditioner with Cascaded H-Bridges (다중브리지로 구성된 UPQC(Unified Power Quality Conditioner)의 동적 성능분석)

  • Han, Byung-Moon;Soh, Yong-Cheol;Kim, Hyun-Woo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.2
    • /
    • pp.94-102
    • /
    • 2006
  • This paper describes experimental analysis of UPQC, which is composed of cascaded H-bridges and single-phase multi-winding transformers. The operational characteristic was analyzed through experimental works with a scaled model, and simulations with PSCAD/EMTDC. The UPQC proposed in this paper can be directly connected to the distribution line without series injection transformers. It has flexibility to expand the operation voltage by increasing the number of H-bridge modules. The analysis results can be utilized to design the actual UPQC system applicable for the actual distribution system.

Improving Adaptability of the DEVS Based Simulator with AOP (AOP 기술을 이용한 DEVS 기반 시뮬레이터의 적응성 향상 기법)

  • Kim, Cheol-Ho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.90-99
    • /
    • 2007
  • The DEVS formalism has the well-defined relationship between its model and simulator. However, it does not define the connection between its model and experimental frame needed when a simulator's implemented with it. So, in most DEVS based simulators, the modules of the two parts are tangled, so that changing and reusing them is not easy. This paper proposes a method to improve the changeability of the experimental frame and the reusability of the model by modularizing the two parts using the AOP technology. I applied the new method to a real project, and the result shows that it improves the two qualities effectively than before.

A Design of an AMI System Based on an Extended Home Network for the Smart Grid (스마트 그리드를 위한 확장 홈 네트워크 기반의 AMI 시스템 설계)

  • Hwang, Yu-Jin;Lee, Kwang-Hui
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.7
    • /
    • pp.56-64
    • /
    • 2012
  • A smart grid is the next generation power grid which combines the existing power grid with information technology, so an energy efficient power grid can be provided. In this paper, in order to build an efficient smart grid an AMI system, which gears with the existing home network and provides an user friendly management function, is proposed. The proposed AMI system, which is based on an extended home network, consists of various functional units; smart meters, communication modules, home gateway, security modules, meter data management modules (MDMM), electric power application modules and so on. The proposed home network system, which can reduce electric power consumption and transmit data more effectively, is designed by using IEEE 802.15.4. The extended home gateway can exchange energy consumption information with the outside management system via web services. The proposed AMI system is designed to enable two-way communication between the home gateway and MDMM via the Internet. The AES(Advanced Encryption Standard) algorithm, which is a symmetric block cipher algorithm, is used to ensure secure information exchange. Even though the results in this study could be limited to our experimental environment, the result of the simulation test shows that the proposed system reduces electric power consumption by 4~42% on average compared to the case of using no control.

An Experimental Study on Control and Development of an Omni-directional Mobile Robot (전방향 이동로봇의 제작과 제어에 관한 실험연구)

  • Lee, Jeong Hyung;Jung, Seul
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.4
    • /
    • pp.412-417
    • /
    • 2014
  • This paper presents the development and control of an omni-directional holonomic mobile robot platform, which is equipped with three lateral orthogonal-wheel assemblies. Omni-directionality can be achieved with decoupled rotational and translational motions. Simulation studies on collision avoidance are conducted. A real robot is built and its hardware is implemented to control the robot. Control algorithm is embedded on DSP and FPGA chips. Hardware for motor control such as PWM, encoder counter, serial communication modules is implemented on an FPGA chip. Experimental studies of following joystick commands are performed to demonstrate the functionality and controllability of the robot.

The Impact of Aircraft Spare Engine and Module Inventory Level on Wartime Operational Availability (항공기 예비엔진 및 모듈 재고수준이 전시 운용가용도에 미치는 영향)

  • Kim, Jinho;Lee, Sangjin;Jung, Sungtae
    • Korean Management Science Review
    • /
    • v.31 no.2
    • /
    • pp.33-48
    • /
    • 2014
  • It is important to maintain on operational availability of aircraft during wartime. The KF-16 fighter, the backbone of the ROKAF (Republic Of Korea Air Force), has a single engine. Therefore, the engine has a critical influence on operational availability. The purpose of this study is to estimate optimal levels of spare part inventories concerning both engines and modules. That is provided by linear programming methods utilizing a developed meta-model. For drawing out the meta-model, we develop a simulation model which can consider wartime demands. In the previous study, $2^k$ factorial design method is used to check the influence of each independent variable. That method requires relatively many scenarios because every extreme value combination of independent variables should be checked. However, this study adopts NOLH (Nearly Orthogonal Latin Hypercube) as an experimental design. By adopting NOLH, this study increases not only efficiency but also accuracy. That is proven by comparing the validity of the developed meta-model on both experimental designs. This study also utilizes the OptQuest simulation tool in ARENA to derive the optimal level of spare stocks. By comparing the result of OptQuest to that of the developed meta-model, the validity of this study is secured.

An Experimental Study of a Water Type Unglazed PV/Thermal Combined Collector Module (액체식 Unglazed PVT 복합모듈의 성능실험연구)

  • Kim, Jin-Hee;Kang, Jun-Gu;Kim, Jun-Tae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.184-189
    • /
    • 2008
  • The excess heat that is generated from PV modules can be removed and converted into useful thermal energy. A photovoltaic/thermal(PVT) module is a combination of photovoltaic module with a solar thermal collector, forming one device that converts solar radiation into electricity and heat simultaneously In general, two types of PVT can be distinguished: glass-covered PVT module, which produces high-temperature heat but has a slightly lower electrical yield, and uncovered PVT module, which produces relatively low-temperature heat but has a somewhat higher electrical performance. In this paper, the experimental performance of water type unglazed PVT combined module, analyzed. The electrical and thermal performance of the module were measured in outdoor conditions, and the results are analyzed. The results showed that the thermal efficiency of the PVT module was 27.05% average and its PV efficiency was about 11.85% average, both depending on solar radiation, inlet water temperature and ambient temperature.

  • PDF