• Title/Summary/Keyword: experimental measurement

Search Result 5,391, Processing Time 0.035 seconds

Transmittance measurement for thickness control of ITO layer (ITO막의 두께 제어를 위한 투과율 측정)

  • 박정규;이무영
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.213-213
    • /
    • 2000
  • A sensor system which can measure the transmittance of ITO(Indium Tin Oxide) layed glass is proposed. The sensor system includes a single wavelength laser beam source, photo diodes and electronic circuit processing sensor signal. The wavelength of laser is 543.5 m, this is most sensitive wavelength to photopic and scotopic vision. We applied the sensor to measure transmittance of ITO layer on general manufacturing environment and verified the effectiveness of sensor through experimental measurement.

  • PDF

Children's Perceptions on Multi-culturalism and their Playfulness with Peers according to the Multi-culturalism Understanding Program by Marital Migrant Women (결혼이주여성교사에 의한 다문화 이해 프로그램과 유아의 다문화에 대한 인식 및 또래와의 놀이성)

  • Park, Jae Ok;Lee, Wanjeong
    • Korean Journal of Childcare and Education
    • /
    • v.8 no.1
    • /
    • pp.45-64
    • /
    • 2012
  • This research is about how infants' multi-cultural recognition and their sphere of activity can be changed when married immigrant women and infants' homeroom teachers were put together in the infants' multi-cultural teaching program. The subjects(children under 5) were selected in "S" city of Gyeonggi-do, South Korea. And they were divided into experimental group 1, experimental group 2, and the control group. And this research did a pretest and post-test for the 60 children. The result of this research can be summarized into three parts. Therefore, it is possible to suggest that the improvement of infants' diversity recognition is affected by a certain kind of teacher and that he/ she can improve the infants' play ability. Experimental group 1 is proceeded by both married immigrant woman and the infants's homeroom teacher. Experimental group 2 was managed by only the homeroom teacher who was going through the same program as the teachers above. The control group was managed by a general nurturing program. This research did do a pretest and post-test for this experiment. -by Chun-Ok. Lee was used for infant's multi-cultural measurement. Mee-sook. Kim's measurement was used for measurement of playfulness between same age children. Meaningful differences was exposed in experimental group 1, experimental group 2, and the control group in sequence. The two experimental groups who had experienced a multi-cultural program seemed to have higher playfulness.

Experimental Measurement and Numerical Computation on the Air-Side Forced Convective Heat Tranfer Coefficient in Plate Fin-Tube Exchangers (평판 핀 튜브 열교환기의 공기측 강제대류 열전달계수에 대한 실험 및 수치계산)

  • Yoon, Young-Hwan;Paeng, Jin-Gi;Yoon, Keon-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.9
    • /
    • pp.729-737
    • /
    • 2006
  • Air-side forced convective heat transfer of a plate fin-tube heat exchanger is investigated by experimental measurement and numerical computation. The heat exchanger consists of staggered arrangement of refrigerant pipes of 10.2 m diameter and the pitch of fins is 3.5 m. In the experimental study, the forced convective heat transfer is measured at Reynolds number of 1082, 1397, 1486, 1591 and 1649 based on diameter of refrigerant piping and mean velocity. Average Nusselt number for the convective heat transfer coefficient is also computed for the same Reynolds number by commercial software of STAR-CD with standard $k-{\varepsilon}$ turbulent model. It is found that the relative errors of average Nusselt numbers between experimental and numerical data are less than 6 percentage in Reynolds number of $1082{\sim}1649$. The errors between experiment and other correlations are ranged from 7% to 32.4%. But the correlation of Kim at al is closest to the experimental data within 7% of the relative error.

Signal Processing of Capacitive Load and Gap Measurement with High Precision Using Surface Acoustic Wave Device (표면 탄성파 장치를 이용한 용량성 부하의 신호처리 및 이를 이용한 초정밀 간극 측정)

  • Kim, Jae-Geun;Lee, Taek-Joo;Lim, Soo-Cheol;Park, No-Cheol;Park, Young-Pil;Park, Kyoung-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.376-380
    • /
    • 2009
  • Surface acoustic wave (SAW) device is widely used as a bandpass filter, a chemical or physical sensor, and an actuator. In this paper, we propose the capacitive gap measurement system with high precision through the signal processing using SAW device. The research process is mainly composed of theoretical part and experimental part. In theoretical part, equivalent circuit model was used to simulate the SAW response by the change of capacitance. In experimental part, commercialized capacitor was used to see the SAW response by the change of load capacitance. After that, gap adjustment system was made physically and the SAW response by the change of gap which caused the capacitance change was measured. And resolution and stroke was decided comparing the signal change and basic measurement noise level.

  • PDF

Experimental Measurement of Magnetic Properties of a Toroidal-type Bulk Electrical Steel using B-waveform Control (자속밀도 파형제어에 의한 토로이달 벌크 전기강의 자기특성 측정)

  • Eum, Young-Hwan;Koh, Chang-Seop;Hong, Sun-Ki;Shin, Pan-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.869-875
    • /
    • 2007
  • Magnetic properties of electrical steel are, in general. measured by using Epstein frame or single sheet tester (SST). These methods, however, require very strict regulation of a specimen in its size and shape. thus, can not be easily applied to various types of specimen. On the other hand, a ring-test method, which measures only the isotropic properties, can be easily applied to most cases because it requires a toroidal-type specimen of arbitrary size. This method, especially, is considered as an unique available method for a bulk-type specimen. In this paper, a ring-test method is developed, and applied to the measurement of magnetic properties of a bulk-type electrical steel with a toroidal-type specimen. In the measurement, the magnetic properties and iron losses are measured and compared with each other at the both sinusoidal magnetic flux density and sinusoidal magnetic field intensity conditions under 0.2Hz and 60Hz alternating magnetic fields excitation. Through experimental measurements, a sinusoidal magnetic flux density condition is proven appropriate for the measurement of magnetic properties, including iron loss characteristics, of electrical steels.

An experimental study for prediction of the fluctuating pressure induced by a cavitating propeller (캐비티가 발생한 프로펠러의 변동압력 추정을 위한 실험적 연구)

  • K.S. Kim;I.S. Moon;K.Y. Kim;I.H. Song;J.T. Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.36 no.1
    • /
    • pp.47-52
    • /
    • 1999
  • The influence of propeller revolution on measurement of fluctuating pressure is almost minimized in the KRISO cavitation tunnel and the measurement accuracy of fluctuating pressure acting on a flat plate due to a cavitating propeller is improved. The measurement data for Sydney Excess propeller is compared with the measurement results of other research institutes loading to the conclusion that KRISO data is so stable and reasonable. The fluctuating pressure data measured on a model ship and the prototype ship is compared with the data measured on the flat plate. The solid boundary factor, derived from a calculation based on a lifting surface theory, is applied to predict full scale pressure level from the experimental data on the flat plate, showing quite reasonable agreement with full scale data.

  • PDF

Development of accuracy enhancement system for boron meters using multisensitive detector for reactor safety

  • Sung, Si Hyeong;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.52 no.3
    • /
    • pp.538-543
    • /
    • 2020
  • Boric acid is used as a coolant for pressurized-water reactors, and the degree of burnup is controlled by the concentration of boric acid. Therefore, accurate measurement of the concentration of boric acid is an important factor in reactor safety. An improved system was proposed for the accurate determination of boron concentration. A new boron-concentration measurement technique, called multisensitive detection, was developed to improve the measurement accuracy of boron meters. In previous studies, laboratory-scale experiments were performed based on different sensitivity detectors, confirming a 65% better accuracy than conventional single-detector boron meters. Based on these experimental results, an experimental system simulating the coolant-circulation environment in the reactor was constructed; accuracy analysis of the boron meter with a multisensitivity detector was performed at the actual coolant pressure and temperature. In this study, the boron concentration conversion equation was derived from the calibration test, and the accuracy of the boron concentration conversion equation was examined through a repeatability test. Through the experiment, it was confirmed that the accuracy was up to 87.5% higher than the conventional single-detector boron meter.

Measurement and Verification of Thermal Conductivity of Multilayer Thin Dielectric Film via Differential 3$\omega$ Method (차등 3$\omega$ 기법을 이용한 다층 유전체 박막의 열전도도 측정 및 검증)

  • Shin Sang-Woo;Cho Han-Na;Cho Hyung-Hee
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.254-259
    • /
    • 2005
  • In this study, measurement of thermal conductivity of multilayer thin dielectric film has been conducted via differential 3$\omega$ method. Also, verification of differential 3$\omega$ method has been accomplished with various proposed criteria. The target film for measurement is 300 nm silicon dioxide and this thin film is covered with various thicknesses of upper protective layer. The upper protective layer is inserted between the target film and the heater line for purpose of electrical insulator or anti-oxidation barrier since the target film may be a good electrical conductor or a well-oxidizing material. However, the verification of differential 3$\omega$ method has not been conducted. Thus we have shown that the measurement of thermal conductivity of thin films with upper protective layer via differential 3$\omega$ method is verified to be reliable as long as the proposed preconditions are satisfied. Experimental results show that the experimental errors tend to increase with aspect ratio between upper protective layer thickness and width of the heater line due to heat spreading effect.

  • PDF

Experimental and Simulated Efficiency of a HPGe Detector in the Energy Range of $0.06{\sim}11$ MeV

  • Park Chang Su;Sun Gwang Min;Choi H.D.
    • Nuclear Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.234-242
    • /
    • 2003
  • The full energy peak efficiency of a hyper pure germanium (HPGe) detector was calibrated in a wide energy range from 0.06 to 11 MeV. Both the experimental technique and the Monte Carlo method were used for the efficiency calibration. The measurement was performed using the standard radioisotopes in the low energy region of $60{\sim}1408$ keV, which was further extended up to 11 MeV by using the $^{14}N(n,r)\;and\;^{35}Cl(n,r)$ reactions. The GEANT Monte Carlo code was used for efficiency calculation. The calculated efficiency had the same dependency on the r-ray energy with the measurement, and the discrepancy between the calculation and the measurement was minimized by fine-tuning of the detector geometry. From the calculated result, the efficiency curve of the HPGe detector was reliably determined particularly in the high energy region above several MeV, where the number of measured efficiency points is relatively small despite the wide energy region. The calculated efficiency agreed with the measurement within about $7\%$. In addition to the efficiency calculation, the origin of the local minimum near 600 keV on the efficiency curve was analyzed as a general characteristics of a HPGe detector.

Measurements of the Vibrational Power Flow in Structure Beam by Using the Structural Intensity Method (Structural Intensity 법을 이용한 구조체의 진동전달량 측정)

  • ;Tichy, Jiri
    • Journal of KSNVE
    • /
    • v.4 no.2
    • /
    • pp.231-238
    • /
    • 1994
  • This paper presents an experimental method to find the vibrational transmission characteristics of structures by using the structural intensity method which is used as the important techniques of active vibration control method. Experimental results are obtained from measurements performed on a structure beam by 2, 3 and 4 position linear accelerometr array (2, 3 and 4 structural intensity : 2, 3 and 4 S.I.) methods at near and farfield conditions. These results are compared with the measurement values of conventional power flow measurement method called input power measurement in order to verify the accuracy of structural intensity methods. To minimize the errors associated with 2, 3 and 4 S.I. methods, the measurement locations were selected by the result of modal analysis and the averaged data by the inter-change of accelerometer array was utilized. In 3 and 4 S.I. methods measured wavenumber instead of theoretical wavenumber was used. This paper shows that measurements of bending wave power flow by using 2, 3 and 4 S.I. methods can give accurate values under general field conditions in structural beam and the accuracy of 2, 3 S.I. methods is higher than 4 S.I. methods. Finally, 2 position linear accelerometer array method is suggested as the practical structural intensity technique.

  • PDF