A Measurement Apparatus of Lateral Restoring Force Exerted on Electrostatically Suspended Object (정전부상체에 작용하는 횡방향 복원력 측정장치)

  • Jeon Jong Up;Park Ki-Tae;Park Kyu-Yeol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.2
    • /
    • pp.60-69
    • /
    • 2005
  • In electrostatic suspension system of thin plates like a silicon wafer or an aluminum disk for hard disk applications, the lateral restoring force exerted on a suspended object plays an important role since the lateral motion of the suspended object, owing to the inherently stable restoring forces, can be passively stabilized without any active control of it. This paper reports about the measurement apparatus of the lateral restoring force originating from a relative translation of the suspended object with respect to the electrodes-for-suspension. An approximate calculation of the lateral force in disk-shaped objects, the structure of the measurement apparatus, a measurement method, stabilization condition and the guideline in designing the measurement apparatus are described. Experimental results obtained by using a 3.5-inch aluminum disk as a suspended object are presented as well in order to assess the magnitude of lateral force and stiffness, and also verify the usefulness of the measurement apparatus.

Analysis of Measurement Precisions Using Measurement Experimental Design for Split Plot (단일분할법 측정 실험계획을 이용한 정밀측정도 분석)

  • Choi, Sung-Woon;You, Jung-Sang
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.32 no.4
    • /
    • pp.223-227
    • /
    • 2009
  • The study presents two measurement split-plot models with a restricted randomization to save cost and time. Split-plot models are used to handle HTCM (Hard To Control Measurement) factors such as high temperature and long-time catalyst control. The models developed are represented by the processes for estimating the measurement precisions, that is, gauge R&R. The study also introduces three-step procedures to indentify resolution, improve R&R reduction, and evaluate the precision effect.

Analysis of Gerontological Nursing Researches in Korea from 1997 to 2003 (국내 노인간호연구 분석 (1997년부터-2003년까지))

  • Yang, Kyung-Mi;Park, Chai-Soon;Kim, Soon-Lae
    • Research in Community and Public Health Nursing
    • /
    • v.15 no.3
    • /
    • pp.419-437
    • /
    • 2004
  • Purpose: This study aims to analyze the trends of the gerontological nursing researches in Korea and suggest the direction for research in this nation. Method: A total of 241 dissertations and other published articles in Korea from 1997 to 2003 were analyzed in this study focusing on the design of the research, key words, measurement tools for basic concepts, and the intervention outcomes in the case of the experimental research. Result: Of those analyzed researches. it was found that 80.9% accounted for the published articles and 19.1% dissertations. There were no clear criteria for the classification of the old men. The most popular research design was an exploratory/descriptive study (54.4%). The major concepts were about 'physical and mental health'. Most of the measurement tools used were developed by foreigners. which were translated into Korean. Among 56 experimental studies, nursing intervention programs in 22 studies were based on physical exercise programs. Conclusion: It is necessary to analyze the trend of gerontological health research in comparison with multidisciplinary researches for elderly people. In addition, the experimental researches for both development and verification of nursing intervention programs are needed. Also, accumulation of research outcomes and development of a standardized instrument for the measurement of Korean elderly people are required.

  • PDF

The effect of motion according to general coordination manipulation treatment on cervical (경추의 전신조정술 관절치료가 관절가동범위에 미치는 영향)

  • Kim Hyoung-Su;Kim Eun-Young;Koo Bong-Oh;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.4
    • /
    • pp.90-102
    • /
    • 2003
  • Purpose: The purpose of this study is to search effect that GCM joint treatment gets to range of motion of cervical, lumbar, trunk and anke. And cervical gets in ankle joint. Methods: Estimated body deformity using GCM body type assesment chart then measured range of motion of each region. After control group did as act freely after do experiment pre measurement control group did post measurement. After control group did as act freely after do experiment premeasurement, control group did postmeasurement. Each region was measured by measurer who each subject person differs. Experimental group did GCM joint treatment and all measurements each region by measurer who each subject person differs three times measure postmeasurement after premeasurement. When measure with each measurement, measured after leave and walk time interval for 10 minutes. Result: For the analysis of the result of experiment, the results is change amount comparison increased to keep in mind except cervical flexion and both ankle joint's dorsiflexion after experiment of experimental group. In experimental group, cervical, lumber and ankle joint of range of motion was significantly increased(p<.05).

  • PDF

Experimental Study of Spacecraft Pose Estimation Algorithm Using Vision-based Sensor

  • Hyun, Jeonghoon;Eun, Youngho;Park, Sang-Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.35 no.4
    • /
    • pp.263-277
    • /
    • 2018
  • This paper presents a vision-based relative pose estimation algorithm and its validation through both numerical and hardware experiments. The algorithm and the hardware system were simultaneously designed considering actual experimental conditions. Two estimation techniques were utilized to estimate relative pose; one was a nonlinear least square method for initial estimation, and the other was an extended Kalman Filter for subsequent on-line estimation. A measurement model of the vision sensor and equations of motion including nonlinear perturbations were utilized in the estimation process. Numerical simulations were performed and analyzed for both the autonomous docking and formation flying scenarios. A configuration of LED-based beacons was designed to avoid measurement singularity, and its structural information was implemented in the estimation algorithm. The proposed algorithm was verified again in the experimental environment by using the Autonomous Spacecraft Test Environment for Rendezvous In proXimity (ASTERIX) facility. Additionally, a laser distance meter was added to the estimation algorithm to improve the relative position estimation accuracy. Throughout this study, the performance required for autonomous docking could be presented by confirming the change in estimation accuracy with respect to the level of measurement error. In addition, hardware experiments confirmed the effectiveness of the suggested algorithm and its applicability to actual tasks in the real world.

Experimental Validation on Underwater Sound Speed Measurement Method Using Cross-Correlation of Time-Domain Acoustic Signals in a Reverberant Water Tank (잔향 수조에서의 시간 이력 수음 신호 간 교차상관을 이용한 수중 음속 계측 방법에 관한 실험적 검증)

  • Joo-Yeob Lee;Kookhyun Kim;Sung-Ju Park;Dae-Seung Cho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.61 no.1
    • /
    • pp.1-7
    • /
    • 2024
  • Underwater sound speed is an important analysis parameter on an estimation of the underwater radiated noise (URN) emitted from vessels. This paper aims to present an underwater sound speed measurement procedure using a cross-correlation of time-domain acoustic signals and validate the procedure through an experiment in a reverberant water tank. For the purpose, time-domain acoustic signals transmitted by a Gaussian pulse excitation from an acoustic projector have been measured at 20 hydrophone positions in the reverberant water tank. Then, the sound speed in water has been calculated by a linear regression using 190 cross-correlation cases of distances and time lags between the received signals and the result has been compared with those estimated by the existing empirical formulae. From the result, it is regarded that the presented experimental procedure to measure an underwater sound speed is reliably applicable if the time resolution is sufficiently high in the measurement.

Simultaneous Multi-Channel Sensor System for Gas Flow Measurementtion Measurement

  • Kim, Young-Han;Joung, Ok-Jin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.95.3-95
    • /
    • 2002
  • A multi-channel electrostatic probe is utilized to determine gas flow rate in a cylindrical container. A numerical analysis is conducted to compare experimental measurement with the computed gas velocity in radial and axial directions.

  • PDF

Development of Measurement Equipment of Membrane Stress Using White Noise Sound Wave (화이트 노이즈 음파를 이용한 막구조물의 장력 측정장치 개발)

  • Jin, Sang-Wook;Ohmori, Hiroshi;Kim, Jae-Yeol
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.2
    • /
    • pp.63-72
    • /
    • 2008
  • One of the most important matters in keeping membrane structures in healthy condition is to maintain the proper tension distribution over the membrane. However, it is not easy to know the real stress level in the membrane quantitatively after completion of the structures. Authors suggested measurement method that can measure membrane stress using sound wave, and have been holding experimental tests of membrane stress measurement that used the sound external excitation with sine wave and white noise. The concept of the method is the fact that measurement of resonance frequency by vibrating membrane having rectangular boundary by audible frequency can measure membrane stress indirectly. In this paper, through the experimental tests it is proved that the equipment can be used for not only the membrane material of type A but also for types B and C. In addition, it is proved that the developed measurement equipment is available to stably measure the membrane stress which exists in the membrane material of the actual membrane structures.

  • PDF

An experimental study of hot filament chemical vapor deposition for diamond films (HFCVD에 의한 다이아몬드 박막 증착에 관한 실험적 연구)

  • Kim, Yeong-Jae;Han, Dong-Cheol;Choe, Man-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.5
    • /
    • pp.563-572
    • /
    • 1998
  • An experimental study of hot filament chemical vapor deposition(HFCVD) has been carried out for the fabrication of diamond thin film. Of particular interest is the measurement of deposition uniformity on large substrates. Experimental apparatus including a vacuum chamber, heating elements, etc. has been designed and manufactured. Deposition profiles for different pretreatment powders and different flow rates have been measured in conjunction with the measurement of substrate temperature distribution on a large substrate surface. As the flow rate increases, deposition rate increases, however, the crystallinity becomes worse. Higher growth rate has been found on the region closer to the center location where substrate temperature is higher. The crystallinity has been improved as gas flow rate decreases. The growth rate and morphology of deposition were identified by SEM and the existence of diamond phase was proved by Raman spectroscopy.