• Title/Summary/Keyword: expected frequency

Search Result 2,002, Processing Time 0.027 seconds

A pooled Bayes test of independence using restricted pooling model for contingency tables from small areas

  • Jo, Aejeong;Kim, Dal Ho
    • Communications for Statistical Applications and Methods
    • /
    • v.29 no.5
    • /
    • pp.547-559
    • /
    • 2022
  • For a chi-squared test, which is a statistical method used to test the independence of a contingency table of two factors, the expected frequency of each cell must be greater than 5. The percentage of cells with an expected frequency below 5 must be less than 20% of all cells. However, there are many cases in which the regional expected frequency is below 5 in general small area studies. Even in large-scale surveys, it is difficult to forecast the expected frequency to be greater than 5 when there is small area estimation with subgroup analysis. Another statistical method to test independence is to use the Bayes factor, but since there is a high ratio of data dependency due to the nature of the Bayesian approach, the low expected frequency tends to decrease the precision of the test results. To overcome these limitations, we will borrow information from areas with similar characteristics and pool the data statistically to propose a pooled Bayes test of independence in target areas. Jo et al. (2021) suggested hierarchical Bayesian pooling models for small area estimation of categorical data, and we will introduce the pooled Bayes factors calculated by expanding their restricted pooling model. We applied the pooled Bayes factors using bone mineral density and body mass index data from the Third National Health and Nutrition Examination Survey conducted in the United States and compared them with chi-squared tests often used in tests of independence.

Expected Overtopping P개bability Considering Real Tide Occurrence

  • Kweonl, Hyuck-Min;Lee, Young-Yeol;Oh, Young-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.479-483
    • /
    • 2004
  • A new calculation method of expected overtopping probability of rubble mound breakwater considering real tide occurrence has been proposed. A calculation method of expected overtopping probability of rubble mound breakwater was proposed by Kweon and Suh (2003). In their calculation, the fluctuation of tidal elevation was expressed by the sinusoidal change that yields the uniform distribution of occurrence frequency. However, the realistic distribution of tidal elevation should influence on the overtopping chance. In this study, the occurrence frequency of tidal elevation obtained from the real sea is included. The tidal elevation used in this study is collected from the east coastal part of Korean peninsular. Analyzing the annual data of the tidal fluctuation measured hourly during 355 days, the distribution of occurrence frequency is formulated utilizing by the normal distribution with one peak. Among the calculation procedures of annual maximum wave height, wave height-period joint distribution, wave run-up height and occurrence frequency of tide, only the annual maximum wave height is again chosen randomly from normal distribution to consider the uncertainty. The others are treated by utilizing the distribution function or relationship itself, It is found that the inclusion of the variability of tidal elevation has great influence on the computation of the expected overtopping probability of rubble mound breakwater. The bigger standard deviation of occurrence frequency is, the lower the overtopping probability of rubble mound breakwater is.

  • PDF

Perception on Nursing Practice of Total Care Service in Nursing Students (간호간병 통합서비스 간호업무에 대한 간호대학생의 인식)

  • Cho, Mi-Kyoung;Koo, Byung-Chul;Kim, Ga-Ran;Cheon, Hong-Seop;Lee, Jee-Young;Lee, Hwan-Hee;Cho, A-Ra;Whang, Ga-Ram;Kang, Shin-Hu;Oh, Ji-Hyeon;Jin, Hyun-A
    • Perspectives in Nursing Science
    • /
    • v.14 no.2
    • /
    • pp.70-80
    • /
    • 2017
  • Purpose: This study aims to identify the factors that affect the expected frequency of performance and the importance in nursing practice of total care service recognized by nursing college students. Methods: This is a descriptive study. A self-administered questionnaire survey was conducted on 288 nursing students of E university and data was collected and analyzed using the SPSS program. Results: The average scores for the expected frequency of performance and the importance in nursing practice of total care service were $4.07{\pm}0.58$ and $4.00{\pm}0.50$ respectively. The expected frequency of performance was found to have a significantly positive correlation with the importance in nursing practice. Additionally, the factors that influenced the degree of recognition in the expected frequency of performance and the importance in nursing practice of total care service among nursing students were comfortable care and respiratory care, respectively. Conclusion: The major finding of this study shows a significantly positive correlation between the expected frequency of performance and the importance in nursing practice. These results suggest that effective and systematic education is needed on factors affecting the expected frequency of performance and the importance in nursing practice for nursing college students.

Estimation of Voltage Swell Frequency Caused by Asymmetrical Faults

  • Park, Chang-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1376-1385
    • /
    • 2017
  • This paper proposes a method for estimating the expected frequency of voltage swells caused by asymmetrical faults in a power system. Although voltage swell is less common than voltage sag, repeated swells can have severe destructive impact on sensitive equipment. It is essential to understand system performance related to voltage swells for finding optimal countermeasures. An expected swell frequency at a sensitive load terminal can be estimated based on the concept of an area of vulnerability (AOV) and long-term system fault data. This paper describes an effective method for calculating an AOV to voltage swells. Interval estimation for an expected swell frequency is also presented for effective understanding of system performance. The proposed method provides long-term performance evaluation of the frequency and degree of voltage swell occurrences.

Frequency Response of the electrode for Indirect-contact ECG (간접접촉 심전도 측정용 전극의 주파수 특성)

  • Lim, Yong-Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.3
    • /
    • pp.249-253
    • /
    • 2008
  • The indirect-contact ECG (IDC-ECG) was introduced by a prior study for daily non-intrusive measurements. To improve the signal quality and to extend the application area of IDC-ECG, close study of the frequency characteristics of the IDC-ECG is necessary. In this study, the frequency response of the active electrode for several sample clothes was measured under conditions of actual IDC-ECG measurement with human body. Higher gain in low frequency range than expected by prior study was observed. In addition to it, wide variation in gain according to the cloth type in the low frequency range was observed. Variation in gain caused by moisture variation in the clothes was also observed. This study shows that the parallel R-C connection is proper for electrode model and the resistive factor is influenced by moisture in the clothes. This study is the first that provides the frequency response of the electrode in the actual indirect-contact ECG measurement and it is expected that the results will be helpful to improve the indirect-contact ECG method.

Design and Implementation of a Novel Frequency Modulation Circuit using Phase Locked Loop Synthesizer (PLL 주파수 합성기를 이용한 새로운 주파수 변조 회로 설계 및 제작)

  • 양승식;이종환;염경환
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.6
    • /
    • pp.599-607
    • /
    • 2004
  • In this paper, using phase locked loop(PLL) synthesizer, we introduce a novel but simple and low cost frequency modulation(FM) circuit of a flat peak frequency deviation fur modulation signal whose frequency covers from outside to inside of the loop-bandwidth of PLL. The FM circuit was basically designed to compensate an amount of feedback of the loop filter in PLL. The circuit also includes the capability of the adjustment of peak frequency deviation and of blocking the intereference with the loop filter. The designed circuit was successfully implemented and showed the flat frequency deviation as expected in the design. In addition, the novel measurement method of the wideband FM modulation index is suggested verified With the suggest measurement, it can be successfully shown the designed circuit has the expected frequency deviation.

Frequency, Expected Effects, Obstacles, and Facilitators of Disclosure of Patient Safety Incidents: A Systematic Review

  • Ock, Minsu;Lim, So Yun;Jo, Min-Woo;Lee, Sang-il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.50 no.2
    • /
    • pp.68-82
    • /
    • 2017
  • Objectives: We performed a systematic review to assess and aggregate the available evidence on the frequency, expected effects, obstacles, and facilitators of disclosure of patient safety incidents (DPSI). Methods: We used the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for this systematic review and searched PubMed, Scopus, and the Cochrane Library for English articles published between 1990 and 2014. Two authors independently conducted the title screening and abstract review. Ninety-nine articles were selected for full-text reviews. One author extracted the data and another verified them. Results: There was considerable variation in the reported frequency of DPSI among medical professionals. The main expected effects of DPSI were decreased intention of the general public to file medical lawsuits and punish medical professionals, increased credibility of medical professionals, increased intention of patients to revisit and recommend physicians or hospitals, higher ratings of quality of care, and alleviation of feelings of guilt among medical professionals. The obstacles to DPSI were fear of medical lawsuits and punishment, fear of a damaged professional reputation among colleagues and patients, diminished patient trust, the complexity of the situation, and the absence of a patient safety culture. However, the factors facilitating DPSI included the creation of a safe environment for reporting patient safety incidents, as well as guidelines and education for DPSI. Conclusions: The reported frequency of the experience of the general public with DPSI was somewhat lower than the reported frequency of DPSI among medical professionals. Although we identified various expected effects of DPSI, more empirical evidence from real cases is required.

Comparisons of the Expected Overtopping Probability along Korean Coast Utilizing by Reliability Analysis (신뢰성 해석에 의한 우리나라 해역별 기대월파확률 특성 비교)

  • Kweon, Hyuck Min;Park, Hyun Suck;Ahn, Kyungmo;Cheon, Se Hyeon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4B
    • /
    • pp.399-404
    • /
    • 2006
  • Kweon et al. (2004) proposed the calculation method of Expected Overtopping Probability (EOP) that considers the occurrence frequency distribution of real sea tide. The method was applied for the comparison of the EOP of Mukho and Busan sea. They showed that the tide occurrence frequency had a great effect on the EOP and the value becomes smaller as the standard deviation of the frequency comes bigger. The present study following Kweon et al.'s method estimates the EOP characteristic of the crest elevation located on East, South, and West sea. The study shows that the EOP becomes smaller following East, South, West sea in order.

Non-Parametric Low-Flow Frequency Analysis Using RCPs Scenario Data : A Case Study of the Gwangdong Storage Reservoir, Korea (RCPs 시나리오 자료를 이용한 비매개변수적 갈수빈도 해석: 광동댐 유역을 중심으로)

  • Yoon, Sun Kwon;Cho, Jae Pil;Moon, Young Il
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.4
    • /
    • pp.1125-1138
    • /
    • 2014
  • In this study, we applied an advanced non-parametric low-flow frequency analysis using boundary kernel by Representative Concentration Pathways (RCPs) climate change scenarios through Arc-SWAT long-term runoff model simulation at the Gwangdong storage reservoir located in Taeback, Gangwondo. The results show that drought frequency under RCPs was expected to increase due to reduced runoff during the near future, and the variation of low-flow time series was appeared greatly under RCP8.5 scenario, respectively. The result from drought frequency of Median flow in the near future (2030s) compared historic period, the case of 30-year low-flow frequency was increased (the RCP4.5 shows +22.4% and the RCP8.5 shows +40.4%), but in the distant future (2080s) expected increase of drought frequency due to the reduction of low-flow (under RCP4.5: -4.7% and RCP8.5: -52.9%), respectively. In case of Quantile 25% flow time series data also expected that the severe drought frequency will be increased in the distant future by reducing low-flow (the RCP4.5 shows -20.8% to -60.0% and the RCP8.5 shows -30.4% to -96.0%). This non-parametric low-flow frequency analysis results according to the RCPs scenarios have expected to consider to take advantage of as a basis data for water resources management and countermeasures of climate change in the mid-watershed over the Korean Peninsula.

Dilemma of a small dam with large basin area under climate change condition

  • Jeong-Hyeok Ma;Chulsang Yoo;Tae-Sup Yun;Dongwhi Jung
    • Computers and Concrete
    • /
    • v.33 no.5
    • /
    • pp.559-572
    • /
    • 2024
  • Problems of under-sized dams (small dams with large basin area) could get worse under the global warming condition. This study evaluates the possible change of these problems with the Namgang Dam, an under-sized dam in Korea. For this purpose, first, this study simulates the dam inflow data using a rainfall-runoff model, which are then used as input for the reservoir operation. As a result, daily dam storage, dam release, and dam water supply are derived and compared for both past observed period (1973~2022) and future simulated period (2006~2099) based on the global warming scenarios. Summarizing the results are as follows. First, the inflow rate in the future is expected to be increased significantly. The maximum inflow could be twice of that observed in the past. As a result, it is also expected that the frequency of the water level reaching the high level is increasing. Also, the amount and frequency of dam release are to be increased in the future period. More seriously, this increase is expected to be concentrated on rather extreme cases with large dam release volume. Simply, the condition for flood protection in the downstream of the Namgang Dam is becoming worse and worse. Ironically, the severity of water shortage problem is also expected to become much worse. As the most extreme case, the frequency of no water supply was zero in the observed period, but in the future period, it becomes once every five years. Both the maximum consecutive shortage days and the total shortage volume are expected to become more than twice in the future period. To prevent or mitigate this coming problem of an under-sized dam, the only countermeasure at this moment seems to be its redevelopment. Simply a bigger dam with larger dam reservoir can handle this adverse effect more easily.