• Title/Summary/Keyword: excitation table

Search Result 118, Processing Time 0.024 seconds

An Assessment Study of Seismic Resistance of Two-story Wood-frame Housing by Shaking Table Tests

  • Ni, Chun;Kim, Sang-Yeon;Chen, Haijiang;Lu, Xilin
    • Land and Housing Review
    • /
    • v.3 no.1
    • /
    • pp.79-82
    • /
    • 2012
  • While there exists a relatively large body of technical information for the engineered design of wood-frame buildings to resist seismic ground motions, the quantitative assessment of seismic resistance of conventional houses built by prescriptive requirements is less well understood. Forintek Canada Corp., in collaboration with other research and industry partners, has embarked on a research project to address this topic. This paper will report on the seismic shake table tests of a full-scale wood-frame building. The two-story specimen, $6m{\times}6m$ in plan, was built on the seismic shake table at Tongji University in Shanghai, China, according to Part 9 of the 1995 National Building Code of Canada and shaken uni-directionally in each of the two principal directions. Three different seismic table motions were applied at increasing peak ground motion amplitudes up to 0.40 and 0.50 g. The specimen was repaired after the above sets of seismic table motions, and successive runs were conducted for increased door openings. Measurements included specimen accelerations, displacements and anchorage forces. Static stiffness of the specimen was measured at low force levels, and natural frequencies were measured after each seismic loading stage by applying low-level random excitation. The results presented consist of the capacity spectra of the shake table tests, changes in specimen stiffness and natural frequencies with increasing seismic loading. These results and those from other recent shake table tests elsewhere will be compared with simplified engineering calculations based on codified values of strength, and on that basis preliminary conclusions will be drawn on the adequacy of the current code provisions and design guides in Canada and the USA for conventional wood-frame construction.

Shaking Table Test of 1/3-Scale 3-Story Sam-Hwan Camus Precast Concrete Model (1/3축소 3층 삼환까뮤 P.C 모델의 진동대 실험)

  • 이한선
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.10a
    • /
    • pp.140-154
    • /
    • 1992
  • The objective of the research stated here was aimed at providing the information needed to establish the Korean Seismic Design Code Recommendations and Guides for precast concrete (P.C) large panel apartment buildings. This was accomplished by investigation and analysis of the response of P.C large panel structures subjected to shaking table excitation simulating earthquake ground motion. one of the test specimens used was 1/3-scaled 3-story box P.C model provided by Sam-Hwan Camus Corporation. The 4m $\times$4m shaking table was used to simulate the earthquake ground motion. the employed input accelerogram was the one recorded as Taft N21E component and the peak ground acceleration(PGA) was scaled depending on the desired level of seismic severity and the time according to dynamic similitude rule. Based on results obtained from shaking table test of this P.C model, the following conclusions were drawn . (1) As far as test specimen is concerned, the seismic safety factors turns out to be 7~8. (2)P.C model has damping ratio of about8% which is twice larger than in-situ R.C. structure. And (3)this model has global displacement ductility ratio of 2~3 through the energy dissipation by opening and sliding of joints.

  • PDF

Examination on Active Pneumatic Vibration Isolation Table with Moving Masses on It by Time Delay Control (이동 질량을 포함하는 능동형 공압제진대에 대한 시간지연제어기법의 적용 검토)

  • Shin, Yun-Ho;Moon, Seok-Jun;Chung, Jung-Hoon;Kim, Byung-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.9
    • /
    • pp.858-867
    • /
    • 2011
  • As applying an active control technique to a pneumatic vibration isolation system, the settling time for the payload excitation could be remarkably reduced as well as the improvement of isolation performance for the ground vibration. Some previous researches were dealt with the settling time through the simulation or experiment but, the discussion on the simulation or experimental results including moving parts, such as a XY-stage, on the isolation table rarely exists. As considering the moving part, the dynamic model could be time varying system and in such a case the force imposed on pneumatic vibration isolation table could be described by inertial forces of moving parts according to Newton's 3rd law, the action and reaction law. In this paper, the simulation procedure of the 3-DOF active pneumatic vibration isolation system including moving parts by TDC(time delay control) technique is proposed and the effectiveness through simulation results are also shown.

Dynamic Test of Structural Models Using 4m $\times$ 4m Shaking Table (4m$\times$4m 진동대를 이용한 구조모델의 동적실험)

  • 이한선
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.04a
    • /
    • pp.207-214
    • /
    • 1997
  • The objective of this study is to review the current stare of earthquake simulation techniques using the shaking table and check the reliability. One degree-of-freedom(d.o.f.)and three d.o.f. aluminium shear models were used and 4m$\times$4m 6 d.o.f. shaking table was excitated in one horizontal direction to simulate 1940 El centro earthquake accelerogram (NS component). When the acceleration history of shaking table is compared to the desired one, it can be found that the overall histories are very similar, but that the lower frequency range (0~2 Hz) of the actual excitation has generally lower amplitude than that of the desired in fourier transform amplitude. Free vibration and white noise tests have shown almost the same values for natural frequencies, but shown quite different values for damping ratios, that is, 1.37% in case of r\free vibration test vs 14.76% in case of white noise test. The time histories of story shear versus story drift show the globally linear elastic behaviors. But the elliptical shape of the histories with one of the axis being the stiffness of the story implies the effect of viscous damping.

  • PDF

Damage evaluation of seismic response of structure through time-frequency analysis technique

  • Chen, Wen-Hui;Hseuh, Wen;Loh, Kenneth J.;Loh, Chin-Hsiung
    • Structural Monitoring and Maintenance
    • /
    • v.9 no.2
    • /
    • pp.107-127
    • /
    • 2022
  • Structural health monitoring (SHM) has been related to damage identification with either operational loads or other environmental loading playing a significant complimentary role in terms of structural safety. In this study, a non-parametric method of time frequency analysis on the measurement is used to address the time-frequency representation for modal parameter estimation and system damage identification of structure. The method employs the wavelet decomposition of dynamic data by using the modified complex Morlet wavelet with variable central frequency (MCMW+VCF). Through detail discussion on the selection of model parameter in wavelet analysis, the method is applied to study the dynamic response of both steel structure and reinforced concrete frame under white noise excitation as well as earthquake excitation from shaking table test. Application of the method to building earthquake response measurement is also examined. It is shown that by using the spectrogram generated from MCMW+VCF method, with suitable selected model parameter, one can clearly identify the time-varying modal frequency of the reinforced concrete structure under earthquake excitation. Discussions on the advantages and disadvantages of the method through field experiments are also presented.

Wavelet based system identification for a nonlinear experimental model

  • Li, Luyu;Qin, Han;Niu, Yun
    • Smart Structures and Systems
    • /
    • v.20 no.4
    • /
    • pp.415-426
    • /
    • 2017
  • Traditional experimental verification for nonlinear system identification often faces the problem of experiment model repeatability. In our research, a steel frame experimental model is developed to imitate the behavior of a single story steel frame under horizontal excitation. Two adjustable rotational dampers are used to simulate the plastic hinge effect of the damaged beam-column joint. This model is suggested as a benchmark model for nonlinear dynamics study. Since the nonlinear form provided by the damper is unknown, a Morlet wavelet based method is introduced to identify the mathematical model of this structure under different damping cases. After the model identification, earthquake excitation tests are carried out to verify the generality of the identified model. The results show the extensive applicability and effectiveness of the identification method.

DEVELOPMENT OF X-Y PLANE DRIVING CONTROL SYSTEM BY STEPPING MOTOR (스텝 모터에 의한 X-Y 평면 구동 제어 시스템 개발)

  • Lee, S.Y.;Kim, B.H.;Park, S.D.;Kim, H.C.;Kim, W.C.;Hong, I.S.;Woo, C.H.;Oh, B.W.;Lee, B.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2166-2168
    • /
    • 1998
  • A PWM inverter using power FET is developed to switch the excitation current of 5 phase hybrid stepping motor for the use of driving X, Y table. A micro processor based controller is also developed to control the excitation current switching of X, Y axis stepping motor as well as synchronizing operation of Z-axis servo motor. The developed driving control system is applied to the industrial embroidery sewing machine.

  • PDF

Shaking Table Test on ASME III Globe Valve with Actuator for Seismic Qualification Program (ASME III 글로브밸브의 내진검증을 위한 진동대시험)

  • 박형기
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.139-146
    • /
    • 1998
  • The prototype ASME III motor actuated Y-type globe valve has been tested to identify dynamic characteristics. The valve is Seismic Category I equipment and has the function to control water flow in the safety-related system. In this study, two different types of structural identification test i.e. swept sine and broadband random, have been performed at various levels of excitation to verify the effects of test method and excitation level on cross coupling effect as well as natural frequencies and damping values. It was found that swept sine test and broadband random test showed similar natural frequencies, and that the primary interaction was exhibited between horizontal and vertical axes.

  • PDF

Seismic Response Characteristics of the Main Building of Bongjeong Temple (봉정사 대응전의 지진응답 특성)

  • Joo, Seok-Jun;Hong, Sung-Gul;Kim, Nam-Hee;Lee, Young-Wook;Jeong, Seong-Jin;Hwang, Jong-Kook
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.235-240
    • /
    • 2007
  • For the identification of the 3 dimensional dynamic characteristics of the Bongjeong Temple, the dynamic test for 1/3 scaled model was performed. Dynamic test with impulse excitation and vibration table excitation can provide useful data for the estimation of dynamic characteristics such as natural frequencies, damping ratios, mode shapes and stiffness center. This will complement the previous research from the 2-dimensional static test and provide the reference data for the enhanced structural analysis of the traditional wooden structures.

  • PDF

Implementation of MPEG-4 HVXC decoder with VHDL (VHOL을 이용한 MPEG-4 HVXC 복호화기 구현)

  • 김구용;임강희;차형태
    • Proceedings of the IEEK Conference
    • /
    • 2001.09a
    • /
    • pp.465-468
    • /
    • 2001
  • MPEG-4 Parametric Coding 중 저 비트율로 음성신호를 부호화하는 HVXC(Harmonic Vector excitation Ending)의 복호화 모듈인 LSP 합성필터와 무성음 합성부, 유성음 합성부를 VHDL을 이용하여 구현하였다. MPEG-4 HVXC의 복호화 과정은 코드북을 이용하여 LSP 계수, VXC signal, 그리고 Spectral Envelop이 복호화 되어 각각 LSP 역필터, 무성음과 유성음 합성단을 통과하여 LPC계수와 유,무성음 여기신호로 변환된 후 LPC 합성필터링 과정을 거쳐 최종적으로 음성신호를 출력시킨다. LSP inverse filter에서 사용되는 cosine함수값을 위하여 Table based Approximation을 이용하여 적은 양의 Table 값을 사용하여 정확하고 고속의 cosine 연산을 수행하였다. VXC 복호화 과정에서는 신호의 중복성을 제거하는 Hidden Address in LSH 방법을 사용하여 코드북의 크기를 줄였다. 유성음 합성단에서는 IFFT 모듈을 이용하여 연산속도를 증가 시켰다. 최종적으로 위와 같이 구현된 시스템을 Simulation을 통해 Software 검증을 하였다.

  • PDF