• Title/Summary/Keyword: excess pattern

Search Result 186, Processing Time 0.025 seconds

Effect of hCG on TeBG (hCG가 TeBG에 미치는 영향)

  • Sung, Ho-Kyung;Kim, Woo-Gyeum
    • The Korean Journal of Physiology
    • /
    • v.14 no.1
    • /
    • pp.7-13
    • /
    • 1980
  • In the previous experiment, authors have shown that during the latter half of estrous cycle there was an increase in plasma testosterone level in the rats stimulated with hCG. To determine the physiologic significance of elevated plasma testosterone, changes of the plasma concentrations of TeBG and testosterone following hCG stimulation were analyzed in the rats having a regular 5 day cycle. The rats were divided into three groups; the control, the rats stimulated with single hCG on the day of proestrus and stimulated with hCG throughout the entire cycle. Blood samples were obtained once a day for an estrous cycle and analyzed for the binding capacity of TeBG using ammonium sulphate precipitation method and testosterone concentration by means of radioimmunoassay. Followings were the results; 1) There was no significant variation in the binding capacity of TeBG in peripheral blood during the estrous cycle of the control rats. 2) No cyclic variation in the binding capacity of TeBG was observed in the rats stimulated with single hCG on proestrus. although the levels tended to be higher in the rats with stimulation than in the control rats. 3) Continual stimulation of hCG produced a marked increase in the binding capacity of TeBG especially on the day of metaestrus. 4) The changes in the plasma level of testosterone followed the same basic pattern seen in the TeBG binding capacity. 5) From above results, the followings were suggested. a. hCG related increase of the binding capacity of TeBG is probably secondary to a modest increase in estrogen as well. b. hCG related increase of plasma testosterone in female rats is not entirely due to excess production rather in part due to decreased metabolism induced by the rise in TeBG. c. It seems likely that most of elevated testosterone shown in the rat stimulated with hCG is bound to TeBG and only small portion is unbound form which influence cellular activity. It is rather possible that an increase in TeBG could augment estrogen activity.

  • PDF

Numerical Analysis of Off-Gas Flow in Hot Area of the Vitrification Plant (유리화공정 고온영역에서의 방사성 배기체 유동해석)

  • Park, Seung-Chul;Kang, Won-Gu;Hwang, Tae-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.3
    • /
    • pp.213-220
    • /
    • 2007
  • Appropriate numerical models for the simulation of off-gas flow in hot area of the vitrification plant have been developed in this study. The models have been applied to analyze the effect of design parameters of real plant and numerical analyses have been performed for CCM(Cold Crucible Melter), pipe cooler and HTF(High Temperature Filter). At first, the effect of excess oxygen and the ratio of oxygen distribution on combustion characteristics in the CCM has been studied. Next, solidification behavior of radio nuclide in the pipe cooler has been numerically modeled and scrutinized. Finally, flow pattern in accordance with the location of off-gas entrance of the HTF has been compared.

  • PDF

Effects of Water Amount in Refrigerant on Cooling Performance of Vehicle Air Conditioner (냉매 내 수분의 혼입량이 차량 에어컨의 냉각성능에 미치는 영향)

  • Moon, Seong-Won;Min, Young-Bong;Chung, Tae-Sang
    • Journal of Biosystems Engineering
    • /
    • v.36 no.5
    • /
    • pp.319-325
    • /
    • 2011
  • This study was conducted to figure out the diagnosis basis of cooling performance depending on water amount in the refrigerant of air conditioner, which can be estimated by the temperatures and pressures along the refrigerant circulation line. A car air conditioner of SONATA III (Hyundai motor Co., Korea) was tested at maximum cooling condition at the engine speed of 1500 rpm in the room controlled at 33~$35^{\circ}C$ air temperature and 55~57% relative humidity conditionally. Measured variables were temperature differences between inlet and outlet pipe surfaces of the compressor, condenser, receive drier and evaporator; and high pressure and low pressure in the refrigerant circulation line; and temperature difference between inlet and outlet air of the cooling vent of evaporator. In this study, changes of the water amount in the refrigerant were correlated to the temperatures and pressure changes and also water amount caused poor cooling performance. As water amount increased in the refrigerant in the air conditioner, the performance of the cooling or the heat transfer became worse. Temporal variations of the surface temperature of the evaporator outlet pipe and the low-side pressure showed various patterns that could estimate the water amount. When the water amount caused bad cooling performance, the patterns of the temperature of the evaporator outlet pipe indicated irregular fluctuation greater than $5^{\circ}C$. When the diagnosis system is using just external sensors of the low-side pressure and the temperatures of inlet and outlet air of cooling vent of the evaporator, the precise pattern of bad cooling performance caused by excess water amount in the cooling line was irregular pressure fluctuation, 25 kPa under 120 kPa, and temperature, $12^{\circ}C$ and less.

Numerical Analysis of Off-Gas Flow in Hot Area of the Vitrification Plant (유리화공정 고온영역에서의 방사성 배기체 유동해석)

  • Park Seung-Chul;Kim Byong-Ryol;Shin Sang-Woon;Lee Jin Wook;Kang Won Gu;Hong Seok Jin
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11a
    • /
    • pp.69-78
    • /
    • 2005
  • Appropriate numerical models for the simulation of off-gas flow in hot area of the vitrification plant have been developed in this study. The models have been applied to analyze the effect of design parameters of real plant and numerical analyses have been performed for CCM(Cold Crucible Melter), pipe cooler and HTF(High Temperature Filter) At first, the effect of excess oxygen and the ratio of oxygen distribution on combustion characteristics in the CCM has been studied. Next, solidification behavior of radio nuclide In the pipe tooler has been numerically modeled and scrutinized. Finally, flow pattern In accordance with the location of off-gas entrance of the HTF has been compared.

  • PDF

A study on Jang Cong-zheng's treatment in "Ru-Men-Shi-Qin" ("유문사친(儒門事親)"에 나타난 장종정(張從正)의 치료법(治療法)에 관(關)한 연구(硏究))

  • Kim, Yong-Hwan;Lee, Sang-Hyup;Kim, Joong-Han
    • Journal of Korean Medical classics
    • /
    • v.25 no.3
    • /
    • pp.127-147
    • /
    • 2012
  • Objective : Methods of Jang Cong-zheng's treatment related to his theories include of promoting the sweating-vomiting-purgation(汗吐下三法), prickling-bleeding method(瀉血療法), and emotional therapy(情志療法). He succeeded Liu wan-su(劉完素) as promoter of fire-heat pattern theory(火熱論), thereby emphasizing six qi(六氣), especially fire(火) and dampness(濕), as pathogens. He suggested that physician should treat patients whose diseases occurred due to fire(火) and dampness(濕) with promoting the sweating(汗)-vomiting(吐)-purgation(下) methods, which would remove pathogen qi(邪氣) and help circulation of qi and blood, therefore getting them back healthy qi(正氣). Method : I will try to describe the Jang Cong-zheng's treatment in "Ru-Men-Shi-Qin", and I would like to explain the sweating-vomiting-purgation(汗吐下三法), prickling-bleeding method(瀉血療法), and emotional therapy(情志療法). Result : For emotional diseases, he suggested that most should be caused by heart fire(心火) so they should be treated with methods of suppressing heart fire and medication would be using cool and cold herbal drugs which lead to clear heart fire. Conclusion : Theories of Zhang zi-he(張子和) can be applied to nurturing for modern world maintaining and improving health by his care methods. People these days suffer usually from excess intake or unbalanced diet problem, so wastes matter and pathogenic qi can be driven out of the human body by applying the sweating-vomiting-purgation methods. His medical theories could contribute to modernization of traditional medicine this way.

The annihilation of the flow pattern defects in CZ-silicon crystal by high temperature heat treatment (고온 열처리에 의한 결정결함의 재용해)

  • 서지욱;김영관
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.11 no.3
    • /
    • pp.89-95
    • /
    • 2001
  • The CZ-silicon crystal was annealed at $1350^{\circ}C$ to dissolve the vacancy type grown-in defects. A this temperature, the equilibrium concentration of the oxygen in the silicon crystal is around $1.7{\times}10^{18}$ which induces the oxygen undersaturation in the silicon crystal. This situation results in the faster dissolution of the grown-in defects in the bulk of the silicon wafer than near the surface. This indicates the possibility that the presence of the higher concentration of silicon interstitial hinders the dissolution of the grown-in defects, which were known to compose of the vacancy clusters with surrounding silicon oxide film. This expectation was confirmed by the observation that the slower dissolution of the grown-in defects near the surface of the silicon wafer in the oxygen atmosphere than in the argon atmosphere. This result is quite opposite to the previous argument hat presence of the excess silicon interstitial leads to faster dissolution of the vacancy type defects.

  • PDF

Scenario Analysis of Personal Nitrogen Dioxide Exposure with Monte Carlo Simulation on Subway Station Workers in Seoul (확률론적 모의실험 기법을 이용한 일부 지하철 근무자들의 이산화질소 개인노출 시나리오 분석)

  • 손부순;장봉기;양원호
    • Journal of Environmental Science International
    • /
    • v.10 no.3
    • /
    • pp.195-200
    • /
    • 2001
  • The personal exposures of nitrogen dioxide(NO$_2$), microenvironmental levels and daily time activity patterns on Seoul subway station workers were measured from February 10 to March 12, 1999. Personal NO$_2$exposure for 24 hours were 29.40$\pm$9.75 ppb. NO$_2$level of occupational environment were 27.87$\pm$7.15 ppb in office, 33.60$\pm$8.64 ppb in platform and 50.13$\pm$13.04 ppb in outdoor. Personal exposure time of subway station workers was constituted as survey results with $7.94\pm$3.00 hours in office, $2.82\pm$1.63 hours in platform and 1 hours in outdoor. With above results, personal $NO_2$exposure distributions on subway station workers in Seoul were estimated with Monte Carlo simulation which uses statistical probabilistic theory on various exposure scenario testing. Some of distributions which did not have any formal patterns were assumed as custom distribution type. Estimated personal occupational $NO_2$exposure using time weighted average (TWA) model was 31.$29\pm$5.57 ppb, which were under Annual Ambient Standard (50ppb) of Korea. Though arithmetic means of measured personal $NO_2$exposure was lower than that of occupational $NO_2$exposure estimated by TWA model, considering probability distribution type simulated, probability distribution of measured personal $NO_2$exposures for 24 hours was over ambient standard with 3.23%, which was higher than those of occupational exposure(0.02%). Further research is needed for reducing these 24 hour $NO_2$personal excess exposures besides occupational exposure on subway station workers in Seoul.

  • PDF

A Study on Workers' Exposure to Organic Solvents in Petroleum Refinery (원유정제업 작업자들의 유기용제에 대한 노출 평가)

  • Choi, Sang Jun;Paik, Nam Won;Kim, Jin Kyoung;Choi, Yeon Ki;Jung, Hyun Hee;Heo, Sung-Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.27-35
    • /
    • 2005
  • This study was carried out to evaluate the characteristics of petroleum refinery workers' exposure to organic solvents. Exposure assessment was conducted by full shift-based long term personal sampling(TWA-P) and task-based short term personal sampling(STEL-P) strategy. Major organic solvents that workers can be exposed are various, varying from C3~C12, and this study focused on 11 kinds including benzene, considering toxicity and concentration level. In comparison with two sampling results, STEL-P shows a significant(p<0.001) excess of exposure level rather than TWA-P. As the potential risk index for benzene is calculated as 16, benzene should be set the highest priority for control in petroleum refinery industry. The tasks with the highest benzene exposure level were de-watering(AM;99.8 ppm), draining(AM;19.6ppm), sampling(AM;16.2ppm), and manual gauging(AM;15.02ppm). Petroleum refinery workers' exposure pattern to organic solvents differs by tasks performed, and some task has a high risk of temporary extreme exposure. Therefore, traditional 8-hour TWA sampling strategy have possibility of underestimation of exposure level of workers in petroleum refinery.

Retail Fashion Buyers' Utilization of Information Source in Dongdaemum Market (동대문 시장을 이용하는 리테일 바이어의 경력 및 소속업체 연매출에 따른 정보원 활용)

  • Kim, Jihye;Chung, Sung-Jee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.16 no.1
    • /
    • pp.41-52
    • /
    • 2014
  • The purposes of this study were to explore differences in utilization of information sources depending on the length of buyers' career and annual sales volume of stores where buyers work for. The questionnaire was prepared by the researcher and was answered by 200 buyers who purchase their items from Dondaemun market. The researcher analyzed the data using both ANOVA and Tukey's test as a post-hoc test. The conclusion of this study is summarized below. First, there were significant differences in utilization of information sources among buyer groups depending on the length of buyers' career. The buyers with more than 10 years career showed more effective utilization of information source such as resident buying offices, manufacturers, trade publications, trade associations, fashion reports, celebrities, window shopping, professional magazines, and advice from others. Second, there were significant differences in utilization of information sources among buyer groups depending on annual sales volume of the stores where the buyers work for. The buyer who work for the store with its annual sales volume in excess of 2 billion won showed more effective utilization of information source such as trade association, professional magazines, sales record, want slips, advertising results, sales trends, customer surveys, sales meetings, customer advisory panel, in-store merchandising bureau and advice from other experienced buyers. However, buyers of the store with its annual sales volume lower than 100 million won showed different pattern utilization of information sources such as vendors, trade publication, celebrities and advice from others.

  • PDF

Analysis of Burnable Poison Effect on Power Distribution using Power Sensitivity Coefficient Concept (출력민감도 계수개념을 이용한 가연성 독붕봉이 출력분포에 미치는 영 향의 분석)

  • Yi, Yu-Han;Oh, Soo-Youl;Seong, Seung-Hwan;Lee, Un-Chul
    • Nuclear Engineering and Technology
    • /
    • v.20 no.1
    • /
    • pp.19-26
    • /
    • 1988
  • The low leakage leading pattern has features as the placement of some fresh fuel assemblies in the core interior to reduce the neutron fluence on the pressure vessel and to enhance the neutron economics. But as fresh fuel assemblies are loaded in the core interior, the local power tends to exceed safety limit due to the high reactivity of the fresh assemblies. Therefore, a large number of burnable poisons must be utilized in a low leakage scheme to suppress the high assembly power as well as the excess reactivity. In this study the effects of burnable poisons are treated as a perturbation on the power distribution, and the 'Power Sensitivity Coefficient' concept is adopted. An application study is performed for cycle 1 of the Korea Nuclear Unit-7 (KNU-7) to justify the usefulness of the reverse depletion method coupled with the above concept. To obtain the optimal burnable poision distribution at the given burnup step, the linear programming technique is adopted. The result shows maximum 4.5% error in the amount of burnable poisons between the calculated and the reference values. It is concluded that the design methodology which consists of the reverse depletion, the power sensitivity coefficient concept, and the linear programming technique can be used to find the optimal turnable poison distribution.

  • PDF