• Title/Summary/Keyword: examination method

Search Result 2,890, Processing Time 0.03 seconds

A Study on the Nursing Needs and Satisfactions of Early Postpartum Women (초기 산욕부의 간호요구도와 만족도에 관한 연구)

  • Yoo, Youn-Ja;Lee, Eun-Ju
    • Women's Health Nursing
    • /
    • v.5 no.3
    • /
    • pp.389-409
    • /
    • 1999
  • This study was carried out to identify the differences between nursing needs and levels of satisfaction of postpartum women during the early postpartum period. The goal of this study was to obtain needed to develope the nursing quality for postpartum women. The subjects were 87 postpartum women who had vaginal delivery at 2 general hospital and 2 maternity hospital in the Ulsan City. The period for the data collection was from June 1 to 29, 1999. The data was gathered using an 98 items questionnaire which was a modified version of a questionnaire the developed by Y. J. Chun. Results found are as follows : 1. The general characteristics of the subjects : The majority of subjects were 25-29 yrs. (57.5%), high school and college graduates(96.5%), unemployed(75.9%), middle ranged economics(93.1%), had no religion(43.7%), male baby(52.9%), birth weight 3-3.5Kg(49.4%), wanted pregnancy(96.6%), no abortion history(50.6%), had antenatal care(89.7%), had prenatal education(32.2%), postnatal education(42.5%), intended breast feeding (46.0%), had resonable self confidence about self(20.7%), infant care(36.8%) and nuclear family pattern(82.3%). 2. The level of nursing needs of overall nursing care(3.93) and the levels of satisfaction(3.86) was relatively high. The nursing needs by category of nursing care, the highest need was in the emotional and psychological care(4.09), and the lowest need was in physical need(3.73). The satisfactions by category of nursing care, the highest satisfaction was in emotional and psychological care(4.11) and the lowest satisfaction was in education in self care(3.64). The significant differences between nursing needs and satisfactions were found on education in infant care(p=.005), and education in self care(p=.020). 3. Among items of physical care, 'accurate medication and treatment(4.21)', 'control of postpartum hemorrhage(4.13)', 'pain control and care of episiotomy wound (4.12)' and 'regular observation of postpartum conditions(4.09)' showed high nursing needs. 'Accurate medication and treatment(4.31)', 'regular observation of postpartum condition(4.24)', 'control of postpartum hemorrhage(4.22)' and 'pain control and care of episiotomy wound(4.12)' showed high satisfaction levels. 4. Among items of emotional and psychological care, 'personal treatment(4.32)', kind and faithful care(4.30)', 'detailed explanation on the treatment or nursing care(4.25)', 'adequate draping during the care and treatment(4.23)' and detailed explanation on a doubt(4.13)', showed high nursing needs, 'personal treatment(4.52)', 'kind and faithful care(4.45)', 'detailed explanation on a doubt(4.24)', 'detailed explanation on the treatment or nursing care(4.21)' and 'adequate draping during the care and treatment(4.18)' showed high satisfaction of nursing care. Difference between the level of nursing needs and satisfaction was significant except item of 'early contacts with their baby and breast feeding'. 5. Among items of environmental care, the highest level of need and satisfaction were on the items of 'neat bedding and clothes(4.05, 4.21)' and 'room cleansing or care of room(4.01, 4.28)'. Differences between the level of nursing care and satisfaction were 'room cleansing of care of room'. 6. Among items of educational needs on self care, 'sitz bath method(4.22)', 'high risk symptoms to immediate clinic visits(4.13)', 'the timing of tub bath(4.05)' and 'good secretion of breast milk(4.03)', showed high nursing needs, 'sitz bath method(4.22)' showed high satisfaction of nursing care. Differences between the level of nursing care and satisfaction were 'the timing of hair shampoo', 'the timing of tub bath', ' the method of pad change', 'postpartum exercise', 'good secretion of breast milk', 'maintenance of breast figure', 'contraindicated drugs in postpartum women', 'kegel exercise' and 'breast self examination'. 7. Among items of educational needs on infant care, 'immunization of infants(4.36)', 'symptoms of sickness to immediate clinic visits(4.28)'. 'safety and emergency care(4.28)', 'umbilical care(4.26)', 'feeding times and intervals(4.24)', 'normal growth and development of infant(4.24)' and 'infection control(4.22)', showed high level of nursing care, 'immunization of infants(4.21)', 'feeding times and intervals(4.17)', were high satisfaction items showed significant differences between the level of nursing care and satisfaction. 8. Relationship between nursing needs and levels of satisfaction among postpartum women were as follows : 1) Physical area : There were no significant differences in the level of nursing needs, but satisfaction levels were significantly different among 'working mothers', 'baby's weights', 'baby's sex', 'planning of feeding' and 'routes of receiving postpartum informations'. 2) Emotional and psychological area : The level of nursing needs were significantly different in the area of 'confidence in self care'. Satisfaction levels were significantly different among 'baby's sex', 'baby's weights', 'the confidence of infant care' and 'working mother'. 3) Environment area : There were on significant differences in the level of nursing needs, but satisfaction levels were significantly different among 'maternal age' and 'baby's weights'. 4) Education in self care : The level of nursing needs were significantly different among 'parity history' and 'type of family formation'. Satisfaction levels were significantly different among 'working mother', 'baby's sex', 'antenatal care', 'postpartum education', 'planning of feeding', 'routes of receiving postpartum informations'. 5) Education in infant care area : The level of nursing needs were significantly different among 'parity history'. Satisfaction levels were significantly different among 'baby's sex', 'receiving postpartum education or not' and 'working mother'.

  • PDF

Standardization of the Method of Measuring Average Glandular Dose (AGD) and Evaluation of the Breast Composition and Thickness for AGD (평균 유선선량 측정방법의 표준화 및 유방 두께, 실질양상과의 상관관계 분석)

  • Park, Hye-Suk;Kim, Hee-Joung;Lee, Chang-Lae;Cho, Hyo-Min;Yu, A-Ram
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.21-29
    • /
    • 2009
  • Breast cancer is the most common form of cancer among korean woman. Therefore, the early detection activities of breast cancer such as breast self-examinations, clinical breast examinations, mammography are important. A yearly mammography examination has been recommended for women aged 40 and older for the early detection of breast cancer in asymptomatic periods. However, the glandular tissue of breast is the most radiation-sensitive tissue, and the determination of average glandular dose (AGD) forms an important part of the quality control of the mammographic systems. Because of the difficulty of estimating AGD directly, it is often estimated from the measurements of the incident air kerma and by applying the appropriate conversion factors. The primary objective of this study was to standardize the method of measuring AGD. The secondary objective was to evaluate the relationships between AGD per various composition and thickness of the breast using Monte Carlo simulations. As a result, we standardized the method of measuring AGD according to International Atomic Energy Agency (IAEA) guidelines (CoP: an international code of practice). Overall, AGD for mammographic practice in Korea was less than 3.0 mGy recommended by the Korea Food and Drug Adminstration (KFDA) protocol, and Korean Institute for Accreditation of Medical Image (KIAMI). The measured and simulated AGD for a given condition were calculated as 1.7 and 1.6 mGy, respectively. For the AGDs obtained, there was no significant difference between them. The simulated AGD was dependent on the fraction of glandular tissue of the breast. The AGD increases with increasing of the breast glandularity due to increasing absorption of low energy photons. The AGD also increases as a function of breast thickness. In conclusion, the results of this study could be used as a baseline to establish a reference level of radiation dose in mammography.

  • PDF

Internal Fixation of Proximal Humerus Fracture with Polyaxial Angular Stable Locking Compression Plate in Patients Older Than 65 Years (65세 이상의 상완골 근위부 골절 환자에서 다축 각안정 잠김 압박 금속판을 이용한 내고정술)

  • Lee, Ki-Won;Choi, Young-Joon;Ahn, Hyung-Sun;Kim, Chung-Hwan;Hwang, Jae-Kwang;Kang, Jeong-Ho;Choo, Han-Ho;Park, Jun-Seok;Kim, Tae-Kyung
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.25-31
    • /
    • 2012
  • Purpose: The clinical and radiographic outcomes of the internal fixation, which were executed on patients over the age of 65 with proximal humerus fracture by using a polyaxial angular stable locking compression plate (Non-Contact-Bridging proximal humerus plate, Zimmer, Switzerland, NCB), were evaluated. Materials and Methods: Thirty two patients over the age of 65 among the proximal humerus fracture treated with NCB plate, between August 2007 and January 2011, were chosen as the subjects. The average age of patients was 71 years, and the average postoperative follow-up period was 11.5 months. The fractures included 14 two-part and 18 three-part fractures. The clinical results were evaluated, using the visual analog scale (VAS) score and the Constant score. The radiological results were evaluated by time to union and Paavolainen method, which measures the neck shaft angle. Results: At the last follow-up examination, the mean VAS score was 3 points and the mean Constant score was 64.5 points, with bone union achieved after the average of 16.2 weeks following the surgery in all the cases. The mean neck shaft angle was 125.9 and 24 cases had good results, while 8 cases had fair results by Paavolainen method, at the last follow-up. There were 1 case of delayed union and cerclage wire failure, and 3 cases of subacromial impingement. There were no complications, such as loss of reduction, nonunion, screw loosening, or avascular necrosis of the humeral head. Conclusion: Internal fixation, using a NCB plate, was considered to be an effective surgical method in treating proximal humerus fracture in the elderly patients, on whom the fixation of the fracture and maintenance of reduction are difficult.

Usefulness of Region Cut Subtraction in Fusion & MIP 3D Reconstruction Image (Fusion & Maximum Intensity Projection 3D 재구성 영상에서 Region Cut Subtraction의 유용성)

  • Moon, A-Reum;Chi, Yong-Gi;Choi, Sung-Wook;Lee, Hyuk;Lee, Kyoo-Bok;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.18-23
    • /
    • 2010
  • Purpose: PET/CT combines functional and morphologic data and increases diagnostic accuracy in a variety of malignancies. Especially reconstructed Fusion PET/CT images or MIP (Maximum Intensity Projection) images from a 2-dimensional image to a 3-dimensional one are useful in visualization of the lesion. But in Fusion & MIP 3D reconstruction image, due to hot uptake by urine or urostomy bag, lesion is overlapped so it is difficult that we can distinguish the lesion with the naked eye. This research tries to improve a distinction by removing parts of hot uptake. Materials and Methods: This research has been conducted the object of patients who have went to our hospital from September 2008 to March 2009 and have a lot of urine of remaining volume as disease of uterus, bladder, rectum in the result of PET/CT examination. We used GE Company's Advantage Workstation AW4.3 05 Version Volume Viewer program. As an analysis method, set up ROI in region of removal in axial volume image, select Cut Outside and apply same method in coronal volume image. Next, adjust minimum value in Threshold of 3D Tools, select subtraction in Advanced Processing. It makes Fusion & MIP images and compares them with the image no using Region Cut Definition. Results: In Fusion & MIP 3D reconstruction image, it makes Fusion & MIP images and compares them by using Advantage Workstation AW4.3 05's Region Cut Subtraction, parts of hot uptake according to patient's urine can be removed. Distinction of lesion was clearly reconstructed in image using Region Cut Definition. Conclusion: After examining the patients showing hot uptake on account of volume of urine intake in bladder, in process of reconstruction image, if parts of hot uptake would be removed, it could contribute to offering much better diagnostic information than image subtraction of conventional method. Especially in case of disease of uterus, bladder and rectum, it will be helpful for qualitative improvement of image.

  • PDF

Evaluation of the Usefulness of Assist Device for Rosenberg View Test (Rosenberg View 검사를 위한 보조기구의 유용성 평가)

  • Kong, Chang gi;Song, Jong Nam;Kim, In Soo;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.129-138
    • /
    • 2020
  • Due to the nature of the Rosenberg Method, the patient needs to maintain posture for a certain period of time, and the joint space is observed in various forms depending on the angle of knee flexion, which causes difficulties in examination. In order to solve these problems, Image quality was evaluated in order to evaluate the usefulness of the assistive device by making the assistive device itself. SNR and CNR analysis about the presence or absence of an assistive device using the extremity phantom and the angle of the assistive device itself were not statistically significant(p < 0.05). As a result of measuring the distance between the right and left edges of the medial condyle based on the presence or absence of an assist device, and the absence of assist device (96.00±40.6 mm) and presence of an assist device (134.86±17.68 mm) were statistically significant (p <0.05). To find the aLDFA relationship about the femur and tibia, we measured the right and left aLDFA based on the presence or absence of assist device. As a result, the absence of the right-side aLDFA assist device (74.63°±4.87) and the presence of assist device (79.64°±3.65) were statistically significant (p <0.05). The absence of the left-side aLDFA assist device (76.39°±4.62) and the presence of assist device (79.64°±3.65) were statistically significant (p < 0.05). but, As a result of measuring the distance of the overlapping parts of the right and left proximal tibiofibular joint and the lateral condyle, There were no statistically significant differences between the right and left sides. In conclusion, we confirmed that we can obtain Diagnostically valuable images with a constant knee-to-knee spacing using an assist device we self-created. In addition, we could learn through aLDFA relationship between femur and tibial that the smaller the angle, the more medial condyle overlaps with JSW, We also confirmed the significance by deriving similar values on the normal range values of aLDFA using assist devices. However, it is considered necessary to pay attention to internal and external rotations in order to obtain good quality images by evaluating the distance of overlapping parts between proximal tibiofibular joint and lateral condyle.

Application of Radiological Study by Small Bowel Disease - Comparison of Diagnostic Results of Small Bowel Series and Abdominal Pelvic Computed Tomography - (소장 질환별 방사선학적 검사의 적용에 관한 연구 - 소장조영술과 복부골반전산화단층촬영의 결과 분석을 중심으로 -)

  • Lee, Hee-Jung;Son, Soon-Yong;Lee, Won-Hong
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.279-286
    • /
    • 2005
  • Purpose : There are two modalities, those are small bowel series(SBS) and abdominal pelvic computed tomography(CT), for diagnosis of small bowel disease. The aim of this study is to lend radiological technologists who are doing the two modalities assistance in the understanding characteristic of disease by comparing the two results. Meterials and method : 284 patients were examined the two SBS and abdominal pelvic CT together from 1999 to 2003. 250 ml $BaSO_4$ suspension 40 w/v% and 600ml carboxy methyl cellulose 0.5 w/v% were used for SBS. Abdominal Pelvic CT was examined in one hour before taking 450 ml $BaSO_4$ suspension 1.5 w/v%. The CT scan was done in 72 sec after 150 ml contrast media injection. the used protocol was helical mode 5:5 mm pitch 1.375:1, speed 27.50, exposure 120 kv, 240 mA, tube rotation time 0.5 sec. the statistic analysis was conducted with statistical program SPSS 10 version with frequency and crossing analysis. P-value less than 0.05 were considered significant. Results : In the results of SBS, normal findings were 131 patients(46.1%), inflammatory bowel disease(IBD) 64(22.9%), ischemia+ileocolitis+vasculitis 22(7.7%), Obstruction+stricture 21(7.7%) and Others 45(15.9%). In the results of abdominal pelvic CT, normal findings were 103 patients(36.3%), inflammatory bowel disease 65(22.9%), wall thickening+lymphadenopathy 42(14.8%), Fluid collection 17(6%), and Others 57case(20%). The same results of the two were 130patients(45.8%). 30patients(10.6%) of normal finding in SBS were diagnosed as wall thickening+lymphadenopathy and IBD in CT, and 15patients(5.3%) of normal finding in CT were diagnosed as ischemia+ileocolitis+vasculitis, mass and IBD in SBS(p<0.05). Transit time delay was diagnosed in 10patients(3.5%) on only SBS, wall thickening+lymphadenopathy was diagnosed in 20patients(7%) in only CT(p<0.05). Conclusion : We think that proper examination method will be selected in the small bowel disease, if we understand the characteristics of the disease and method.

  • PDF

Evaluate Utility of Thyroid Cancer Discrimination by 18F-FDG PET/CT Delay Scan Images (18F-FDG PET/CT검사에서 지연영상을 이용한 갑상선암 진단의 유용성 평가)

  • Lee, Hyeon-Guck;Han, Man-Seok;Kim, Yong-Kyun;Seo, Sun-Youl;Jeon, Min-Cheol;Kim, Tae-Hyung;Hong, Seong-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2958-2965
    • /
    • 2013
  • Purpose : To evaluate the degree of malignancy of incident thyroid lesion found in 18F-FDG PET/CT findings and the usefulness of the method suggested in this study, we applicate the Delay Scan Method that differentiate a false positive benign tumor, inflammation and malignancy, as well as make the criteria of SUV. Materials and Methods : A retrograde study was conducted of 25 patients(1 exception) who were admitted in E hospital to receive 18F-FDG PET/CT examination until Janaary and April of 2008. 18F-FDG PET/CT image photographing was taken in Biograph-Duo made by SIEMENS, after taking normal 18F-FDG PET/CT image(1hr) and then 1hr later we took the thyroid 1 bed-delayed image for the patients who showed abnormal thyroid 18F-FDG uptake and above 2.0 SUV for 2 minutes every 1 bed. For the patients who showed abnormal thyroid uptake and above 2.0 SUV, 1hr later, we took a 1 bed-delayed image and then made a comparative study between measured maxSUV of 1hr-abnormal uptake image and that of 2hr-delayed image. Results : In this 18F-FDG PET/CT study among the patients who showed incidental 18F-FDG thyroidal uptake the number of thyroid cancer was 5(20.8%), all of then showed benign findings. a comparison of results for 18F-FDG PET/CT. the benign patient measured maxSUV in the PET/CT. image(1hr) mean value 5.06maxSUV and delay image(2hr) mean value 5.23maxSUV differences of two value is 0.19maxSUV and the malignantIt patient measured maxSUV in the PET/CT. image(1hr) mean value 9.63maxSUV and delay image(2hr) mean value 10.65maxSUV differences of two value is 10.65maxSUV in Thyroid abnormal uptake patients. Conclusion : in the case of incidental 18F-FDG uptake in thyroid, max SUV of focal thyroid lesion is above 5.0 if 18F-FDG PET/CT examine the delayed images to add, You could see that reasonable diagnostic method useful. to differentiate whether lesions of malignant.

Experiments on the stability of the spatial autocorrelation method (SPAC) and linear array methods and on the imaginary part of the SPAC coefficients as an indicator of data quality (공간자기상관법 (SPAC)의 안정성과 선형 배열법과 자료 품질 지시자로 활용되는 SPAC 계수의 허수 성분에 대한 실험)

  • Margaryan, Sos;Yokoi, Toshiaki;Hayashi, Koichi
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.121-131
    • /
    • 2009
  • In recent years, microtremor array observations have been used for estimation of shear-wave velocity structures. One of the methods is the conventional spatial autocorrelation (SPAC) method, which requires simultaneous recording at least with three or four sensors. Modified SPAC methods such as 2sSPAC, and linear array methods, allow estimating shear-wave structures by using only two sensors, but suffer from instability of the spatial autocorrelation coefficient for frequency ranges higher than 1.0 Hz. Based on microtremor measurements from four different size triangular arrays and four same-size triangular and linear arrays, we have demonstrated the stability of SPAC coefficient for the frequency range from 2 to 4 or 5 Hz. The phase velocities, obtained by fitting the SPAC coefficients to the Bessel function, are also consistent up to the frequency 5 Hz. All data were processed by the SPAC method, with the exception of the spatial averaging for the linear array cases. The arrays were deployed sequentially at different times, near a site having existing Parallel Seismic (PS) borehole logging data. We also used the imaginary part of the SPAC coefficients as a data-quality indicator. Based on perturbations of the autocorrelation spectrum (and in some cases on visual examination of the record waveforms) we divided data into so-called 'reliable' and 'unreliable' categories. We then calculated the imaginary part of the SPAC spectrum for 'reliable', 'unreliable', and complete (i.e. 'reliable' and 'unreliable' datasets combined) datasets for each array, and compared the results. In the case of insufficient azimuthal distribution of the stations (the linear array) the imaginary curve shows some instability and can therefore be regarded as an indicator of insufficient spatial averaging. However, in the case of low coherency of the wavefield the imaginary curve does not show any significant instability.

Analysis of Factors Influencing the Integrated Bolus Peak Timing in Contrast-Enhanced Brain Computed Tomographic Angiography (Computed Tomographic Angiography (CTA)의 검사 시 조영제 집적 정점시간에 영향을 미치는 특성 인자를 분석)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Jung, Jae-Yong;Yun, Jung-Soo;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.59-69
    • /
    • 2016
  • The objective of this study was to analyze the factors influencing integrated bolus peak timing in contrast-enhanced computed tomographic angiography (CTA) and to determine a method of calculating personal peak time. The optimal time was calculated by performing multiple linear regression analysis, after finding the influence factors through correlation analysis between integrated peak time of contrast medium and personal measured value by monitoring CTA scans. The radiation exposure dose in CTA was $716.53mGy{\cdot}cm$ and the radiation exposure dose in monitoring scan was 15.52 mGy (2 - 34 mGy). The results were statistically significant (p < .01). Regression analysis revealed, a -0.160 times decrease with a one-step increase in heart rate in male, and -0.004, -0.174, and 0.006 times decrease with one-step in DBP, heart rate, and blood sugar, respectively, in female. In a consistency test of peak time by calculating measured peak time and peak time by using the regression equation, the consistency was determined to be very high for male and female. This study could prevent unnecessary dose exposure by encouraging in clinic calculation of personal integrated peak time of contrast medium prior to examination.

A Study on the Structure and Function of the Underground Storage Facility in Baekje (백제 지하저장시설(地下貯藏施設)의 구조와 기능에 대한 검토)

  • Shin, Jong-Kuk
    • Korean Journal of Heritage: History & Science
    • /
    • v.38
    • /
    • pp.129-156
    • /
    • 2005
  • Increasing discovery cases of underground storage facilities made of earth, wood, or stone are being reported from the recent excavation survey of the Baekje relics. Accordingly, the purpose of this study is to examine the structure and function of the underground storage facilities of Baekje following a classification made by the type and building method as follows: plask shape, wooden box shape, and stone box shape. The plask shape storage is the most representative underground storage of Baekje that has been found in numerous relics more than 600 sets around Hangang(Han River) and Geumgang(Geum River) from the Hansung period to Sabi period in Baekje Dynasty. It is a historical artefact as a part of the unique storage culture of Baekje around Hangang and Geumgang from the 3rd to 7th Century. Considering its structure and the example of Chinese one, it might had been used for a long-term storage of grains and various other items including earth wares. The storage facility in wooden box shape and stone box shape are found mostly in the relics Of Sabi period. Thus it might had taken some functions of the storage in traditional pouch shape which had decreased after the 6th Century. In particular, the wooden box shape and stone box shape storage required enormous labor force to build owing to their structure and building method. Thus, they were considered to had been used for official purposes in province fortress and citadel artefact. The wooden box shape storage facility is classified into flat rectangular type and square type based on the structure, and into Gagu type(架構式) and Juheol type(柱穴式) based on the building method. It might had been decided according to the geography and geological feature of the place where the storage was to be built. Considering the examples of Gwanbuk-ri relics and Weolpyong-dong relics, the wooden box shape storage facility might had been used for various items depending on the needs, including foods such as fruits and essential provisions at the military base. Considering the long-term food storage, the examples in Japan, and the functional characteristics of the underground storage facility, there is a possibility that the wooden and stone box shape storage facilities had been built so as to safely store important items in case of fire. This study is only a rudimentary examination for the storage facility in Baekje. Thus further studies are to be made specifically and comprehensively on the comparison with other regions, distribution pattern, discovered relics and artefacts, and functions.