• 제목/요약/키워드: exact difference

검색결과 707건 처리시간 0.031초

강체모드분리와 급수전개를 통한 준해석적 민감도 계산 방법의 개선에 관한 연구(I) - 정적 문제 - (A Refined Semi-Analytic Sensitivity Study Based on the Mode Decomposition and Neumann Series Expansion (I) - Static Problem -)

  • 조맹효;김현기
    • 대한기계학회논문집A
    • /
    • 제27권4호
    • /
    • pp.585-592
    • /
    • 2003
  • Among various sensitivity evaluation techniques, semi-analytical method(SAM) is quite popular since this method is more advantageous than analytical method(AM) and global finite difference method(FDM). However, SAM reveals severe inaccuracy problem when relatively large rigid body motions are identified fur individual elements. Such errors result from the numerical differentiation of the pseudo load vector calculated by the finite difference scheme. In the present study, an iterative method combined with mode decomposition technique is proposed to compute reliable semi-analytical design sensitivities. The improvement of design sensitivities corresponding to the rigid body mode is evaluated by exact differentiation of the rigid body modes and the error of SAM caused by numerical difference scheme is alleviated by using a Von Neumann series approximation considering the higher order terms for the sensitivity derivatives.

2치수차 사이클로이드 감속기의 형상설계에 관한 연구 (A Study on Epitrochoidal Tooth Profile in A Two Teeth Difference Cycloidal Reducer)

  • 신중호;권순만;김봉주;김종찬;김무성
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.389-390
    • /
    • 2006
  • The cycloidal reducer is one of the velocity controlling equipments in machinery. It has advantages of the higher reduction ratio, the higher accuracy, the easier adjustment of the transmission ratio and the smaller workspace than any other kinds of the reducers. This paper proposes a simple and exact approach for the lobe profile design of the two teeth difference cycloidal plate gear, which is different from the standard cycloidal reducer, by means of the principle of the instant velocity center in the general contact mechanism and the homogeneous coordinate transformation.

  • PDF

Two-way ANOVA를 활용한 공동주택 내 타일 하자의 유형 및 위치에 따른 발생기간 차이 특성 (Characteristics of the difference in occurrence period according to the type and location of tile defects in an apartment house using two-way ANOVA)

  • 편수정;김규용;최병철;김문규;이예찬;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.29-30
    • /
    • 2022
  • Tile defects in apartment houses are caused by a combination of various factors. These factors cannot be specified, and it is difficult to determine the exact cause because a number of causes are intertwined. In addition, because the climate of Korea is different by season, the coefficient of thermal expansion between materials is different, which is a major cause of tile defects. Therefore, this study analyzed the difference between the construction location and the period of defect occurrence according to the types of tile defects caused by environmental differences between indoor and outdoor environments. Two-way ANOVA was used, indoor and outdoor spaces were selected, and defect types were selected accordingly to show the difference in the occurrence period of each defect.

  • PDF

수면 대장내시경 검진자에게 시행한 복부마사지의 효과 (The Effect of Abdominal Massage on Sleep Colonoscopy Subjects)

  • 이윤정;제남주
    • 한국산학기술학회논문지
    • /
    • 제20권6호
    • /
    • pp.410-420
    • /
    • 2019
  • 본 연구는 수면 대장내시경 검진자에게 복부마사지를 시행하여 장운동 회복과 복부팽만감에 미치는 효과를 파악하기 위하여 시도된 비동등성 대조군 전후 시차설계연구이다. 연구대상자는 C시, G병원에서 외래를 통해 수면 대장내시경 검진을 받는 실험군 22명, 대조군 22명으로 자료 수집 기간은 2018년 6월 1일부터 8월 25일까지였으며, 실험의 확산효과를 막기 위하여 대조군을 먼저 자료수집 한 후 시차를 두고 실험을 실시하였다. 자료분석은 IBM SPSS 24.0을 이용하여 자료를 분석하였으며, 대상자의 일반적 특성의 동질성을 검증하기 위하여 독립표본 t-test, $x^2-test$ 와 Fisher's exact probability test, 실험군, 대조군의 복부둘레 변화량에 대한 정규성을 검증하기 위하여 Shapiro-Wilk로 검증, 복부둘레의 사전 동질성을 검증하기 위하여 Mann-Whitney U test를 실시하였다. 실험처치 효과 검증은 Fisher's exact probability test, Friedman test와 Mann-Whitney U test로 검증하였다. 연구 결과, 복부마사지가 대장내시경 검진자의 가스배출 시간($x^2=19.75$, p<.001)과 복부팽만감($x^2=29.93$, p<.001)을 감소시켜, 수면 대장내시경 검진자의 가스팽만으로 인한 불편감을 완화하는 간호중재로 활용할 수 있을 것으로 생각된다.

유리선량계를 이용한 저선량 방사선의 마우스 피폭선량 연구 (A Study on Mice Exposure Dose for Low-dose Gamma-irradiation Using Glass Dosimeter)

  • 노성진;김효진;김현;정동혁;손태건;김정기;양광모;남상희;강영록
    • Journal of Radiation Protection and Research
    • /
    • 제40권4호
    • /
    • pp.202-210
    • /
    • 2015
  • 저선량 조사는 낮은 선량을 지속적으로 장기간 조사시키기 때문에 조사되는 마우스들에 대한 선량분포를 정확히 알고 있어야만 한다. 본 연구는 저선량 방사선에 대한 생물학적 영향평가를 위하여 동남권원자력의학원 연구센터에 설치된 $^{137}Cs$ 조사장치에 대하여 마우스조사 실험 시 마우스에 원하고자 하는 선량을 전달하기 위한 방법에 대하여 연구를 수행하였다. 마우스에 원하고자 하는 정확한 선량을 전달하기 위하여 선원에 대하여 동일한 위치에 마우스 케이지 45개를 설치할 수 있는 아파트를 자체 개발하였으며, 개발된 마우스 아파트 시스템에 대한 선량평가를 하기 위하여 유리선량계(glass dosimeter)를 실험용 마우스 머리와 배에 삽입한 후 기존 조사 시스템과 자체 개발한 마우스 아파트 시스템에 대해 비교 선량평가를 수행하였다. 기존시스템의 조사방식에서 최대 42%의 선량차이를 보였으며 개발한 마우스 아파트 시스템은 6% 이내의 선량차이를 보였다. 본 연구를 통해 개발된 마우스 아파트를 활용한 저선량 방사선에 대한 생물학적 영향평가 연구는 전달하고자 하는 선량을 보다 정확하게 제공할 수 있으며, 생물학적 분석결과에 신뢰성을 확보할 수 있다.

침치료에 익숙한 한국의 여자 임상시험 피험자를 대상으로 한 침관 변형을 통한 Minimal acupuncture 경험 (A study on the minimal acupuncture using a modified guide tube for Korean female participants familiar with acupuncture therapy)

  • 노진주;정수경;최민선;최선미;김동일
    • 대한한방부인과학회지
    • /
    • 제20권3호
    • /
    • pp.200-212
    • /
    • 2007
  • Purpose: To find objective validity of minimal acupuncture using a modified guide tube as a method to verify the effect of acupuncture. Methods: Subjects of this study were participants of a randomized clinical trial which was practiced to verify the effect of acupuncture on postmenopausal hot flash. There were 2 arms of treatment, one's for active acupuncture group(AG) with manipulation and De qi, the other's for minimal acupuncture group(MG) using a modified guide tube which was designed to give minimal stimulation to the patient. After 8 weeks' treatment followed by 4 weeks' observation, participants were asked to fill in self-report forms on their education, previous experiences of acupuncture, original idea on the efficacy of acupuncture and recognition of blinding. Results: 19 participants of 26 in AG and 19 of 26 in MG completed the self-report form. There was no difference between AG and MG in their education(p=0.5976, Fisher exact test) and previous experiences of acupuncture(p=0.9999, Fisher exact test). In their original ideas on the efficacy of acupuncture, most of AG and MG respondents have been thought that acupuncture is very effective or quite effective, and there was no difference between 2 groups(p=0.5065). 16 of 19 in AG and 14 of 19 in MG believed that they underwent more effective way, there was no statistical difference between 2 groups(p=0.6928, Fisher exact test). Participants believed in undergoing more effective way not because they recognized treatment method, but they were satisfied with the effectiveness of treatment retrospectively. Conclusion: As the result of this study, these authors suggest that minimal acupuncture using a modified guide tube is acceptable as a method to verify the effect of acupuncture in acupuncture-familiar Korean culture. Also further studies on the stimulation-specific effect of minimal acupuncture are demanded.

  • PDF

폐암 환자의 전신 정위적 방사선 수술시 정확한 SET UP에 대한 고찰 (The consideration about exact set-up with stereotactic radiosurgery for lung cancer.)

  • 서동린;홍동기;권경태;박광호;김정만
    • 대한방사선치료학회지
    • /
    • 제16권2호
    • /
    • pp.1-8
    • /
    • 2004
  • 목적 : 전신 정위적 방사선 수술환자 치료 시 환자의 set up을 정확히 확인하고 평가하는 것은 치료 성적을 좌우 하는데 중요한 요소이다. 특히 폐암 환자의 경우 호흡 등에 의한 종양의 움직임으로 인해서 L-gram이나 EPID를 이용하여 정확한 위치를 확인하는데는 여러 가지 어려움이 있다. 이러한 문제점들에 대하여 verification system(exactrac)을 이용하여 set up의 정확성을 확인해 보고자 한다. 대상 및 방법 : Body frame(elekta, sweden)을 이용하여 전신 정위적 방사선 수술을 받는 폐암 환자 6명을 대상으로 (ABC tool을 사용한 환자 5명과 사용 안한 환자1명) 기존의 L-gram과 EPIDs로 image를 획득하여 Ant, Lat image를 비교하여 환자의 set-up을 확인하고 CT에서 얻은 DRR image와 Verification system(exactrac)의 X-ray image를 얻어서 두image를 3차원적으로 fusion하여 그 좌표 값(vertical, longitudinal, lateral)을 분석하고 기존의 방법과의 차이를 확인하였다. 결과 : L-gram과 EPIDs로는 정확한 좌표 값보다는 주관적으로 Set up의 정확성 여부를 판단하여 치료할 수 있었지만 Verification system(exactrac)을 이용하여 확인한 결과 치료환자의 Set up 전, 후의 좌표 값(vertical, longitudinal, lateral)이 0.5cm이내에 포함되는 것을 볼 수 있었고 좌표 값의 차이를 시각적이고 객관적으로 평가할 수 있어서 Set up의 정확성을 판단하는 데 유용했다. 결론 : Verification system(exactrac)을 사용하면 환자의 Set up이 정확한 지 치료 전 또는 중간에도 시각적인 확인이 가능한 장점이 있지만 기존의 방법보단 확인과정이 조금 복잡하고 CT scan 시 3mm 이내로 해야 하며 X-ray image가 선명하게 나타나야 된다는 단점이 있다. 이러한 문제점만 해결된다면 Set up의 정확성을 쉽게 확인할 수 있어서 치료 시 많은 도움이 되리라고 생각된다.

  • PDF

굴의 패각으로부터 추출된 단백질의 특성연구 (Characteristics of protein extracted from oyster shell)

  • 이승우;신나영;최청송
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2001년도 추계학술발표대회
    • /
    • pp.37-40
    • /
    • 2001
  • We showed the result that an appreciable difference of secondary structures in the intracrystlline protein was observed between Normal and Deform shells. In order to understand the exact secondary structure of proteins, we investigated the changes in protein conformation from the specific layers via Fourier Self-Deconvolution(FSD) techniques, using ATR(Attenuated Total Reflection) information.

  • PDF

가치공학(VE)에 있어 Fuzzy Set을 이용한 기능평가 방법 (A Function Evaluation by Fuzzy Set in Value Engineering)

  • 이근희;이동형
    • 산업경영시스템학회지
    • /
    • 제13권22호
    • /
    • pp.43-50
    • /
    • 1990
  • In conventional function analysis, the function values are evaluated by experts, which are treated as exact values. For many cases, it is often difficult to evaluate the function values of a certain subject because the criteria of evaluation are very vague. This paper presents a new function evaluation method using fuzzy set. The purpose of the method is to minimize the difference among experts by recognizing an intersection point of membership function as a representative value.

  • PDF

Intensity차를 이용한 차선의 위치 검출에 관한 연구 (A Study on the Estimation of Lane position using difference of Intensity)

  • 손경희;송현승;노도환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.403-403
    • /
    • 2000
  • Generally estimation of driving direction uses the way which uses lane detection and vanishing point in autonomous-driving system. Especially we use Sub-window for decreasing Process time when we detect lane, but fixed sub-window can not detect lane because of some factors in road image. So we suggest algorithm using one-dimension line scan method to detect an exact position of lane.

  • PDF