• Title/Summary/Keyword: evaporation rates

Search Result 160, Processing Time 0.026 seconds

The Effects of Hydrogen on DME HCCI Combustion (DME 예혼합 압축착화 엔진에서 수소의 영향)

  • Baek, Cheul-Woo;Yoon, Hyeon-Sook;Yeom, Ki-Tae;Jang, Jin-Young;Bae, Choong-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.15-21
    • /
    • 2007
  • The aim of this paper is controlling ignition timing and load in homogeneous charge compression ignition (HCCI) combustion with low cetane number fuel, hydrogen. Homogeneous charge compression ignition (HCCI) combustion is an advanced combustion technology that achieves higher thermal efficiency and lower $NO_x$ emissions than that of conventional combustion system. Dimethyl ether (DME), which has been researched widely as the most attractive alternative fuel of diesel, is attractive for HCCI combustion because of the easy evaporation. In this study, the single cylinder DME engine operated with a direct injection system has been used to investigate combustion processes and emissions of DME HCCI with a premixed hydrogen supply. The experiment was carried out under various engine speed and fraction rates of hydrogen. As a result, the increase of fraction rates of hydrogen retard the DME ignition timing and eliminated the knocking during high engine speed condition. IMEP was increased with increase of fraction rates of hydrogen by 30%. 40% of the fraction rates of hydrogen resulted in misfiring. The $NO_x$ emission was reduced by increasing the fraction rates of hydrogen, but HC emission was increased.

Basic Studies on the Consumptive Use of Water Required for Dry Field Crops -Tomato and Chinese Cabbage- (밭작물소비수량에 관한 기초적 연구 -토마토 및 가을배추-)

  • 김철기;김진한;최홍규
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.30 no.3
    • /
    • pp.25-37
    • /
    • 1988
  • The purpose of this study is to fmd out the bask data for irrigation plans of tomato and chinese cabbage during the growing period, such as total amount of evapotranspiration, coefficients of evapotranspiration at each growth stage, the peak stage of evapotranspiration, the maximum evapotranspiration, optimum irrigation point, total readily available moisture and intervals of irrigation date. The plots of experiment were arranged with split plot design which were composed of two factors, irrigation point for main plot and soji texture for split plot, and three levels, irrigation points with PF 1.8, PF 2.2, PF 2.6 for tomato and those with PF 1.9, PF 2.3, PF 2.7, for Chinese cabbage, soil textures of silty clay, sandy loam and sandy soil for both tomato and Chinese cabbage, with two replications. The results obtained are summarized as follows 1. There was the highest significant correlation between the evapotranspiration and the pan evaporation, beyond all other meteoralogical factors considered. Therefore, the pan evaporation is enough to be used as a meteorological index measuring the quantity of evapotranspiration. 2. 1/10 probability values of maximum total pan evaporation during growing period for tomato and Chinese cabbage were shown as 355.8 mm and 233.0 mm, respectively, and those of maximum ten day pan evaporation for tomato and Chinese cabbage, 68.0 mm and 43.8 mm, respectively. 3. The time that annual maximum of ten day pan evaporation can be occurred, exists at any stage of growing period for tomato, and at any growth stage till the late of Septemberfor Chinese cabbage. 4. The magnitude of evapotranspiration and of its coefficient for tomato and Chinese cabbage was occurred in the order of pF 1.8>pF 2.2>pF 2.6 and of pF 1.9>pF 2.3>pF 2.7 respectively in aspect of irrigation point and of silty clay>sandy loam>sandy soil in aspect of soil texture. 5. 1/10 probability value of evapotranspiration and its coefficient during the growing period of tomato were shown as 327.3 mm and 0.92 respectively, while those of Chinese cabbage, 261.0 mm and 1.12 respectively. 6. The time that maximum evapotranspiration of tomato can be occurred is at the date of fortieth to fiftieth after transplanting and the time for Chinese cabbage is presumed to he in the late of septemben At that time, 1/10 probability value of ten day evapotranspiration and its coefficient for tomato is presumed to be 74.8 mm and 1.10 respectively, while those of Chinese cabbage, 43.8 mm and 1.00. 7. In aspect of only irrigaton point, the weight of raw tomato and Chinese cabbage were mcreased in the order of pF 2.2>pF 1.8>pF 2.6 and of pF 1.9>pF 2.3>pF 2.7, respectively but optimum irrigation point for tomato and Chinese cabbage, is presumed to be pF 2.6 - 2.7 if nonsignificance of the yield between the different irrigation treatments, economy of water, and reduction in labour of irrigaion are synthetically considered. 8. The soil moisture extraction patterns of tomato and Chinese cabbage have shown that maximum extraction rate exists at 7 cm deep layer at the beginning stage of growth m any soil texture and that extraction rates of 21 cm to 35 cm deep layer are increased as getting closer to the late stage of growth. And especially the extraction rates of 21 cm deep layer and 35 cm deep layer have shown tendency to be more increased in silty clay than in any other soils. 9. As optimum irrigation point is presumed to be pF Z6-2.7, total readily available moisture of tomato in silty clay, sandy loam and sandy sofl becomes to be 19.06 mm, 21.37 mm and 20.91 mm respectively while that of Chinese cabbage, 18.51 mm, 20.27 mm, 21.11 mm respectively. 10. On the basis of optimum irrigation point with pF 2.6 - 2.7 the intervals of irrigation date of tomato and Chinese cabbage at the growth stage of maximum consumptive use become to be three days and five days respectively.

  • PDF

A Study on Composition of Solvent Thinners and Evaporation in the Air (일부 신나의 구성성분과 공기중 증발에 관한 연구)

  • Zoh, Kyung Ehi;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.245-263
    • /
    • 1997
  • For twelve solvent thinners, evaporation rates of components were investigated and models to estimate the actual concentration have been evaluated. Also, the current ACGIH TLVs (Threshold Limit Values) for the concentration of organic mixtures have been adjusted. The results of this study are summarized as follows : 1. Airborne concentrations of solvent thinner components were related to their respective vapor pressure (r=0.96). On the other hand, there was no significant relation between the concentrations in the air of the thinner compounds and the original amount in liquid form. 2. Airborne concentrations of each chemical were estimated by temperature at $8.5{\pm}1$, $16.7{\pm}1$ and $31.5{\pm}2^{\circ}C$ with an air velocity of 1.5 m/s. The concentrations were increased by increasing temperature (p<0.05). The percentage of concentrations were proportionate to their respective percentage of vapor pressure. Among the chemicals studied, n-butyl acetate, n-butyl alcohol, m-xylene, p-xylene and o-xylene showed a clear relationship to temperature. 3. Airborne concentration of each chemical was estimated by air velocity at 0.05, 1.50 and 2.50 m/s, with a constant temperature at $17{\pm}2^{\circ}C$. The concentrations were increased by increasing air velocity (p<0.05). The percentage of concentrations were proportionate to their respective percentage of vapor pressure. Among the chemicals studied, n-butyl alcohol, m-xylene and p-xylene showed a clear relationship to velocity. 4. In estimating the concentrations of solvent thinners by temperature and air velocity, ACGIH TLVs for mixtures tended to be larger than the values obtained by ACGIH exposure index. It shows that ACGIH TLVs for mixtures are not adequate for evaluating the airborne concentration of thinners and other organic mixtures. 5. The evaporation rate of the thinners were compared to the theoretical equations of Hummel, Braun and Mackay. The Hummel and Braun methods were close to exposure index but Makay's showed an underestimated value. In order to see the accuracy of each three models, the SSE (Error Sum of Squares) calculated for Hummel's was 1.73, being the closest to the actual values. 6. Present ACGIH TLVs for mixtures are not appropriate evaluate industrial environments. In this study, a correction of TLVs using vapor pressure of respective components was suggested. In order to evaluate the corrected TLVs a paired t-test was performed. There was no significant difference between the exposure index and the concentration over suggested TLVs (p>0.05). Thus, this corrected TLVs seem appropriate in order to evaluate actual industrial workplaces organic chemical concentration in the air.

  • PDF

Evaporation Heat Transfer and Pressure Drop of R-404A at Low Flow Rates in 9.5 mm O.D. Smooth and Microfin Tubes (낮은 유량에서 외경 9.5 mm 평활관과 마이크로핀관 내 R-404A 증발 열전달 및 압력 손실)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.27-36
    • /
    • 2018
  • A significant amount of studies were performed on evaporation heat transfer and pressure drop in microfin tubes. Most studies, however, focused on the refrigerants used in air-conditioners or heat pumps, and very limited information is available on R-404A, which is used in low temperature refrigeration. In this study, the evaporation heat transfer and pressure drop characteristics of R-404A in a 9.5 mm O.D. microfin tube were investigated for the mass flux range from $80kg/m^2s$ and $200kg/m^2s$. A smooth tube of the same outer dimeter was also tested for comparison. The results showed that the heat transfer enhancement ratio of the microfin tube increased with increasing mass flux and the heat flux decreased. The relative contribution of the convective heat transfer and the heat flux on total heat transfer was attributed to the observed trend. The pressure drops of the microfin tube were slightly (maximum 28%) larger than those of the smooth tube. Existing correlations do not adequately predict the measured heat transfer coefficients of pressure drops, probably due to the test range of the present study, which is outside of the existing correlations.

A Study on Heat and Mass Transfer in a Vertical Tube Absorber Using LiBr Family Solutions (LiBr계 용액을 사용한 수직관 흡수기의 열 및 물질 전달에 관한 연구)

  • Cho, H.C.;Kim, C.B.;Jeong, S.Y.;Kang, S.W.;Lee, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.196-206
    • /
    • 1995
  • Experimental investigations on heat and mass transfer characteristics in a vertical tube absorber have been carried out. Three different copper tubes with a length of 1.5m have been tested using LiBr solution and LiBr-$CaCl_2$ solution. The effects of solution flow rate, cooling water temperature, solution inlet temperature and evaporation temperature have been investigated in detail. It is found that heat transfer coefficient increases gradually with the increase of solution flow rate, but decreases rapidly for the flow rates less than 0.02kg/ms. The grooved tube generally shows better heat transfer performances than the smooth tube. LiBr solution shows almost no absorption capability for the cooling water temperatures over $40^{\circ}C$. LiBr-$CaCl_2$ gives less decreasing rate in absorption capability at these temperatures and the heat transfer coefficient becomes less dependent on the types of tubes in use. Considering heat and mass transfer rates, LiBr-$CaCl_2$ solution is found to be more suitable than LiBr solution for air cooled absorber, which operates at higher temperature than water cooled absorber.

  • PDF

Thermogravimetric and Fourier Transform Infrared Analysis of Switchgrass Pyrolysis (스위치그라스 열분해에 대한 TGA-FTIR 분석)

  • Lee, Seong-Beom;Fasina, Oladiran O.
    • Journal of Biosystems Engineering
    • /
    • v.34 no.1
    • /
    • pp.44-49
    • /
    • 2009
  • This study was conducted to investigate the pyrolysis characteristics of switchgrass using TGA-FTIR instrument. Switchgrass is a high yielding perennial grass that has been designated as a potential energy crop, because of its high energy value. Ground switchgrass were pyrolysed at different heating rates of 10, 20, 30, and $40^{\circ}C/min$ in a TGA-FTIR instrument. The thermal decomposition characteristics of switchgrass were analyzed, and the gases volatilized during the experiment were identified. The thermal decomposition of switchgrass started at approximately $220^{\circ}C$, followed by a major loss of weight, where the main volatilization occurred, and the thermal decomposition was essentially completed by $430^{\circ}C$. The pyrolysis process was found to compose of four stages; moisture evaporation, hemicellulose decomposition, cellulose decomposition, and lignin degradation. The peak temperatures for hemicellulose decomposition ($306^{\circ}C$ to $327^{\circ}C$) and cellulose decomposition ($351^{\circ}C$ to $369^{\circ}C$) were increased with greater heating rates. FTIR analysis showed that the following gases were released during the pyrolysis of switchgrass; $CO_2$, CO, $CH_4$, $NH_3$, COS, $C_{2}H_{4}$, and some acetic acid. The most gas species were released at low temperature from 310 to $380^{\circ}C$, which was corresponding well with the observation of thermal decomposition.

Optimal Estimation of Water Use in the Large-Scale Basin (대규모 유역에서의 적정 용수이용량 산정)

  • Ryoo, Kyong-Sik;Hwang, Man-Ha
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.3
    • /
    • pp.3-10
    • /
    • 2007
  • In general method to estimate the water supplies in the large-scale basin, indirect estimation method such as unit loading factor method has been used. However, the estimated water supplies are much different to the real water supplies used in the any basin because these general methods estimate them considering water supply demands only. Especially, water supplies for irrigation are big different to the real water supplies in which the water supplies for irrigation are depend on the weather conditions such as evaporation, basin conditions such as infiltration, the reservoir operation rule for irrigation water, and distribution methods. Thus, a new estimation method is developed to estimate the real water demands which is essential factors for the effective water resources operation in the basin. This method is for estimating the water supplies and return rates based on the survey of the irrigation reservoirs and the analysis of effects to the stream flows, return flows, and water supplies for irrigation which water supplies and return rates are used in the basin water management model. The water supply usages in each subbasin are validated by comparisons between the simulated discharges from the basin water management model and the discharges measured in the control points.

THERMAL EFFECTS OF EYELID IN HUMAN EYE TEMPERATURE MODEL

  • Gokul, K.C.;Gurung, D.B.;Adhikary, P.R.
    • Journal of applied mathematics & informatics
    • /
    • v.32 no.5_6
    • /
    • pp.649-663
    • /
    • 2014
  • Presence of eyelid on anterior ocular surface and its thermal effects play significant role in maintaining eye temperature. In most of the literatures of thermal modeling in human eye, the eyelid is not considered as an eye component. In this paper, finite element model is developed to investigate the thermal effects of eyelid closure and opening in human eye. Based on different properties and parameter values reported in literatures, the bio-heat transfer process is simulated and compared with experimental results in steady and transient state cases. The sensitivity analysis using various ambient temperatures, evaporation rates, blood temperatures and lens thermal conductivities is carried out. The temperature values so obtained in open eye show a good agreement with past results. The closure of eyelid is found to increase/decrease the eye temperature significantly than its opening, when the parameter values are considered to be at extreme.

The Influence of Bi-Sticking Coefficient in Bi-2212 Thin Film

  • Lee, Hee-Kab;Park, Yong-Pil;Lee, Joon-Ung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04b
    • /
    • pp.152-156
    • /
    • 2000
  • Bi-thin films are fabricated by an ion beam sputtering, and sticking coefficients of the respective elements are evaluated. The sticking coefficient of Bi element exhibits a characteristic temperature dependence : almost a constant value of 0.49 below $730^{\circ}C$ and decreases linearly with temperature over $730^{\circ}C$. This temperature dependence can be elucidated from the evaporation and sublimation rates of bismuth oxide, $Bi_2O_3$, from the film surface. It is considered that the liquid phase of the bismuth oxide plays an important role in the Bi(2212) phase formation in the co-deposition process.

  • PDF

Effects of Various Deposition Rates of Al2O3 Gate Insulator on the Properties of Organic Thin Film Transistor (알루미늄 옥사이드 절연층의 증착율이 유기박막 트랜지스터의 특성에 미치는 영향)

  • Choi, Kyung-Min;Hyung, Gun-Woo;Kim, Young-Kwan;Choi, Eou-Sik;Kwon, Sang-Jik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.12
    • /
    • pp.1063-1066
    • /
    • 2009
  • In this study, we fabricated pentacene organic thin film trasistors(OTFTs) which used aluminum oxide as the gate insulator. Aluminum oxide for OTFTs was deposited on glass substrate with a different deposition rate by E-beam evaporation. In case of the deposition rate of $0.1\;{\AA}$, the fabricated aluminum oxide gate insulating OTFT showed a threshold voltage of -1.36 V, an on/off current ratio of $1.9{\times}10^3$ and field effect mobility $0.023\;cm^2/V_s$.