• 제목/요약/키워드: evaporation effect

검색결과 778건 처리시간 0.03초

핀-튜브 열교환기에서 PVE오일이 증발/응축 열전달 성능에 미치는 영향 (The Effect of PVE Oil on the Evaporation/Condensation Heat Transfer Performance of Fin-tube Heat Exchanger)

  • 이현우;정영만;이재근;박내현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1067-1072
    • /
    • 2009
  • In vapor compression systems which use refrigerant as a working fluid, the oil is commonly used for compressor lubrication. Since the presence of lubrication oil can change the characteristics properties of refrigerant, the oil affects the heat transfer performance of heat exchanger to a large extent. In this paper, we focus on the effect of PVE oil experimentally on heat transfer performance of the fin-tube heat exchangers which use R410A as a refrigerant. To evaluate the heat transfer performance, the refrigerant to air type test facility chamber has been used. Fin-tube heat exchanger with grooved has been tested while according to the oil mass fraction variation from nearly zero to 1.7 wt%. It was found that the low level of oil mass fraction has an obvious effect on heat transfer performance, while the high level seems no significant influence. The influence of the oil mass fraction to heat transfer performance, however, is different between evaporation and condensation.

  • PDF

산부인과 펄스형 $CO_2$ 레이저의 펄스 특성에 의한 안정된 동작파형의 시스템 (System of stable action waveform by pulse special quality of obstetrics and gynecology pulse style $CO_2$ laser)

  • 김휘영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.55-57
    • /
    • 2007
  • $CO_2$ laser sees that is most suitable to get this effect through minimum formation damage and advantage that is root enemy of effect that happen in minimum cellular tissue depth of 0.1mm is stable living body organization or internal organs institution. Formation damage by ten can be related in formation's kind or energy density, length of evaporation time. If shorten evaporation time, surroundings cellular thermal damage 200 - because happen within 400ums laser beam in rain focus sacred ground surroundings cellular, tissue without vitiation me by evaporation Poe of very small floor as is clean steam can. Application is possible to vulva cuticle cousins by a paternal aunt quantity, uterine cancer, cuticle tumor by laser system that $CO_2$ laser gets into standard in obstetrics and gynecology application. Because effect that super pulse output is ten enemies of laser if uniformity one pulse durations are short almost is decreased, most of all pulse module special quality of pulse style $CO_2$ laser for obstetrics and gynecology mode stabilization by weight very, in this research to get into short pulse duration and higher frequency density, do switching by high frequency in DC-DC Converter output DC's ripple high frequency to be changed, high frequency done current ripple amount of condenser for output filter greatly reduce can. Ripple of output approximately to Zero realization applying possible inductor realization through a special quality experiment do.

  • PDF

운전조건에 따른 R744용 해양온도차 발전 사이클의 성능 특성 (Performance Characteristics of R744 OTEC Power Cycle with Operation Parameters)

  • 윤정인;손창효;백승문;김현주;이호생
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.580-585
    • /
    • 2012
  • R744용 해양온도차 발전 시스템의 작동변수에 대한 기초 설계자료를 제공하고자 증발열량, 응축열량, 전체일량, 효율에 대한 사이클 성능을 분석하였다. 본 연구에서 고려된 작동변수는 R744 해양온도차 발전 사이클의 과열도, 과냉각도, 응축온도, 증발온도 등이다. 주요 결과를 요약하면 다음과 같다. R744의 증발열량은 과열도와 과냉각도가 증가할수록 증가하는 반면, 응축온도가 증가할수록 감소한다. 전체일량은 R744의 과열도와 과냉각도와 함께 증가하나 증발온도는 증가할수록 감소한다. 그리고 효율은 과열도와 과냉각도가 증가할수록 증가하는 반면, 응축온도는 감소한다. 그러므로 R744용 해양온도차 발전 시스템의 증발열량, 응축열량, 전체일량, 효율은 과열도, 과냉각도, 응축온도, 증발온도, 펌프와 터빈 효율에 영향을 받는 것을 알 수 있었다. 따라서 R744용 해양온도차 발전 시스템의 설계시에는 이러한 영향을 면밀하게 파악하여야 한다.

도시의 수목이 기온의 조절에 미치는 영향 (Influences of Urban Trees on the Control of the Temperature)

  • 김수봉;김해동
    • 한국조경학회지
    • /
    • 제30권3호
    • /
    • pp.25-34
    • /
    • 2002
  • The purpose of this paper is to discuss the function of microclimate amelioration of urban trees regarding the environmental benefits of street trees in summer, focusing on the heat pollution-urban heat island, tropical climate day's phenomenon and air pollution. We measured the diurnal variation of air/ground temperatures and humidity within the vegetation canopy with the meteorological tower observation system. Summertime air temperatures within the vegetation canopy layer were 1-2$^{\circ}C$ cooler than in places with no vegetation. Due to lack of evaporation, the ground surface temperatures of footpaths were, at a midafternoon maximum, 8$^{\circ}C$ hotter than those under trees. This means that heat flows from a place with no vegetation to a vegetation canopy layer during the daytime. The heat is consumed as a evaporation latent heat. These results suggest that the extension of vegetation canopy bring about a more pleasant urban climate. Diurnal variation of air/ground temperatures and humidity within the vegetation canopy were measured with the meteorological tower observation system. According to the findings, summertime air temperatures under a vegetation canopy layer were 1-2$^{\circ}C$ cooler than places with no vegetation. Due mainly to lack of evaporation the ground surface temperature of footpaths were up to 8$^{\circ}C$ hotter than under trees during mid-afternoon. This means that heat flows from a place where there is no vegetation to another place where there is a vegetation canopy layer during the daytime. Through the energy redistribution analysis, we ascertain that the major part of solar radiation reaching the vegetation cover is consumed as a evaporation latent heat. This result suggests that the expansion of vegetation cover creates a more pleasant urban climate through the cooling effect in summer. Vegetation plays an important role because of its special properties with energy balance. Depended on their evapotranspiration, vegetation cover and water surfaces diminish the peaks of temperature during the day. The skill to make the best use of the vegetation effect in urban areas is a very important planning device to optimize urban climate. Numerical simulation study to examine the vegetation effects on urban climate will be published in our next research paper.

증기 재압축을 활용한 증발공정에서 스팀 절감에 대한 연구 (The Reduced Steam Consumptions in the Evaporation Process Using a Vapor Recompression)

  • 노상균
    • 청정기술
    • /
    • 제22권4호
    • /
    • pp.225-231
    • /
    • 2016
  • 본 연구에서는 2중 효용 증발관을 이용하여 21.0 wt%의 NaCl 수용액에서 고형물의 NaCl을 $1,524.58kg\;h^{-1}$만큼 석출시키는 공정에 대해서 증기 재압축을 활용하여 스팀 소모량을 $3,139kg\;h^{-1}$에서 $496kg\;h^{-1}$로 줄이는 공정에 대한 전산모사 및 최적화 작업을 수행하였다. 디에틸렌 글리콜(diethylene glycol)을 포함한 NaCl 수용액을 농축시키기 위한 증발농축 공정의 전산모사를 위해서는 AspenTech사의 Aspen Plus V8.8을 활용하였으며, 중간에 냉각기를 가지는 증기 재압축 공정의 전산모사를 위해서는 Schneider Electric사의 PRO/II with PROVISION V9.4를 이용하였다. 증기 재압축 공정에 대해서는 1기의 압축기를 사용한 공정과 중간에 냉각기를 가지는 2단 압축 공정을 상호 비교하였다.

미세채널 내 이산화탄소의 증발 열전달 특성 및 오일의 영향에 관한 실험적 연구 (Experimental Study on Characteristics of Evaporation Heat Transfer and Oil Effect of $CO_2$ in Mini-channels)

  • 이상재;김대훈;최준영;이재헌;권영철
    • 설비공학논문집
    • /
    • 제21권1호
    • /
    • pp.16-22
    • /
    • 2009
  • In order to investigate $CO_2$ heat transfer coefficient and pressure drop by PAG oil concentration during $CO_2$ evaporation, the experiment on evaporation heat transfer characteristics in a mini-channels were performed. The experimental apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes($300{\sim}800kg/m^{2}s$), heat fluxes($10{\sim}40kW/m^2$) saturation temperatures($-5{\sim}5^{\circ}C$), and PAG oil concentration(0, 3, 5wt%). The variation of the heat transfer coefficient was different according to the oil concentration. With the increase of the oil concentration, the evaporation heat transfer coefficient decreased and the delay of dryout by oil addition was found. Pressure drop increased with the increase of the oil concentration and heat flux, and the decrease of saturation temperature.

수평원관내 $CO_2$의 증발열전달 (Evaporation Heat Transfer of Carbon Dioxide in a horizontal Round Tube)

  • 경남수;장승일;최선묵;손창효;오후규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.262-267
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ in a horizontal round tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 7.75 mm, and length of 5 m. The experiments were conducted at mass flux of 200 to 500 $kg/m^2s$, saturation temperature of $-5^{\circ}C$ to $5^{\circ}C$, and heat flux of 10 to 40 $kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. In comparison with teat results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

  • PDF

판형열교환기에서 POE오일이 R134a 증발 열전달에 미치는 영향에 대한 실험적 연구 (Experimental study on Effects of POE oil on R134a Evaporation Heat Transfer in Plate Heat Exchanger)

  • 장영수;장재규;강병하;김석현
    • 대한기계학회논문집B
    • /
    • 제38권3호
    • /
    • pp.255-262
    • /
    • 2014
  • 판형열교환기의 증발과정에서 오일에 위한 영향을 알아보기 위해 마이크로 기어 펌프를 이용한 냉매-R134a 순환 성능실험 장치를 구성하여, 증발열전달 실험을 수행하였다. POE 오일을 펌프를 이용하여 냉매 질량 유량에 비례하도록 0~5%를 첨가하여, 오일순환량에 따른 열전달계수 변화를 측정하였다. 오일순환율이 증가할수록 R134a 증발 열전달계수는 감소하며, 압력손실은 증가한다. 질량유량 80 g/s, 증발 온도 $30^{\circ}C$ 일 때, 오일 순환율 2%조건에서 무오일 대비 약 10%의 열전달계수가 감소하였고, 압력손실은 약 10% 증가하였다.

반응적 교수법이 예비화학교사들의 증발과 끓음에 관한 수업설계 인식에 미친 영향 (The Effect of Responsive Teaching Method on the Recognition of Pre-service Chemistry Teachers about Instructional Design related to Evaporation and Boiling)

  • 조나연;김은지;백성혜
    • 대한화학회지
    • /
    • 제63권2호
    • /
    • pp.123-133
    • /
    • 2019
  • 이 연구에서는 H대학교 화학교육과 예비교사들을 대상으로 반응적 교수법의 효과를 알아보고자 하였다. 이를 위하여 토론을 학습자 생각의 본질 존중하기, 학습자 생각에서 학문적 연결 관계 인식하기, 학습자 생각의 본질 확장하기의 3단계로 구성하였다. 학습자 생각의 본질 존중하기 단계에서는 예비교사 20명을 대상으로 실시한 설문지를 분석하여 증발과 끓음에 관련된 예비교사들의 생각의 본질을 파악하였다. 이 중에서 5명의 예비교사를 선발하여 자신의 생각과 학문적 연결 관계를 인식하도록 하였다. 이러한 단계를 통해 예비교사들은 증발과 끓음에 대한 자신들의 생각의 본질을 파악하였으며, 이러한 생각의 본질을 학문적으로 연결하여 사고의 프레임을 수정하거나 확장하는 과정을 경험하였다. 또한 예비교사 스스로 자신의 개념이 역동적인 변화하는 과정을 직접 체험함으로써 반응적 교수법의 효과를 인식하였다.

낙동강 중류에서 하천 증발이 안개에 미치는 영향 (The Influence of Evaporation from a Stream on Fog Events in the Middle Nakdong River)

  • 박준상;김규랑;강미선;김백조
    • 한국지구과학회지
    • /
    • 제38권6호
    • /
    • pp.395-404
    • /
    • 2017
  • 본 연구에서는 구미에 위치한 낙동강에서 발생한 안개를 분류하였고 안개 발생 전후의 기상특성을 분석하였다. 안개는 2013년부터 2015년까지 시정계를 이용하여 관측되었다. 안개는 총 74회 발생하였고 대부분 증기안개로 분류되었다. 관측된 증기 안개는 내륙에서 발생한 안개보다 지속시간이 길게 나타났는데 이는 지형적 특징으로 인해 야간 증발이 다른 지역보다 강하게 나타났기 때문이다. 안개 지속시간에 대한 하천 증발 효과를 분석하기 위해 Penman-Monteith(Penman법)와 Bulk aerodynamic (Bulk법) 방법을 사용하여 증발량을 추정하였다. 이 중 Bulk법은 실제 수면에서 측정한 증발량과 유사하게 나타났다. 따라서 Bulk법이 실제 수면 증발량 추정에 적합한 방법임을 확인할 수 있었다. Bulk법으로 추정한 증발량은 안개 비발생일 보다 안개 발생일에 06 LST와 07 LST에 더 높게 나타났다. 안개 발생일에 하천의 증발은 대기에 증발잠열 에너지를 공급하고 안개 내부의 난류를 유지하는 에너지원으로 작용한다. 이와 같은 결과는 안개내부의 풍속, 기온, 그리고 난류운동에너지의 증가를 통해 확인하였다.