• Title/Summary/Keyword: evaluate a image

Search Result 2,316, Processing Time 0.031 seconds

Automatic Detection and Classification of Rib Fractures on Thoracic CT Using Convolutional Neural Network: Accuracy and Feasibility

  • Qing-Qing Zhou;Jiashuo Wang;Wen Tang;Zhang-Chun Hu;Zi-Yi Xia;Xue-Song Li;Rongguo Zhang;Xindao Yin;Bing Zhang;Hong Zhang
    • Korean Journal of Radiology
    • /
    • v.21 no.7
    • /
    • pp.869-879
    • /
    • 2020
  • Objective: To evaluate the performance of a convolutional neural network (CNN) model that can automatically detect and classify rib fractures, and output structured reports from computed tomography (CT) images. Materials and Methods: This study included 1079 patients (median age, 55 years; men, 718) from three hospitals, between January 2011 and January 2019, who were divided into a monocentric training set (n = 876; median age, 55 years; men, 582), five multicenter/multiparameter validation sets (n = 173; median age, 59 years; men, 118) with different slice thicknesses and image pixels, and a normal control set (n = 30; median age, 53 years; men, 18). Three classifications (fresh, healing, and old fracture) combined with fracture location (corresponding CT layers) were detected automatically and delivered in a structured report. Precision, recall, and F1-score were selected as metrics to measure the optimum CNN model. Detection/diagnosis time, precision, and sensitivity were employed to compare the diagnostic efficiency of the structured report and that of experienced radiologists. Results: A total of 25054 annotations (fresh fracture, 10089; healing fracture, 10922; old fracture, 4043) were labelled for training (18584) and validation (6470). The detection efficiency was higher for fresh fractures and healing fractures than for old fractures (F1-scores, 0.849, 0.856, 0.770, respectively, p = 0.023 for each), and the robustness of the model was good in the five multicenter/multiparameter validation sets (all mean F1-scores > 0.8 except validation set 5 [512 x 512 pixels; F1-score = 0.757]). The precision of the five radiologists improved from 80.3% to 91.1%, and the sensitivity increased from 62.4% to 86.3% with artificial intelligence-assisted diagnosis. On average, the diagnosis time of the radiologists was reduced by 73.9 seconds. Conclusion: Our CNN model for automatic rib fracture detection could assist radiologists in improving diagnostic efficiency, reducing diagnosis time and radiologists' workload.

GET Imaging Evaluation of Patients with Esophageal Cancer (식도암 환자의 GET 영상 평가)

  • Moon, Jong Wun;Lee, Chung Wun;Seo, Young Deok;Yun, Sang Hyeok;Kim, Yong Keun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.31-36
    • /
    • 2013
  • Purpose: Measure gastric emptying time (GET: Gastric Emptying Time) is a non-invasive and quantitative evaluation methods, mainly by endoscopic or radiological examination confirmed no mechanical obstruction in patients with symptoms of congestion is checked. Such tests are not common gastric emptying time measured esophageal cancer patients (who underwent esophagectomy) patients after surgery for gastric emptying time was measured test. And the period of time for more than one year after the gastric emptying time measurement was performed. By comparing the two kinds of tests in the chest cavity after surgery as the evaluation of gastrointestinal function tests evaluate the usefulness of GET, and will evaluate the characteristics of the image. Materials and Methods: 93 patients who underwent esophagectomy with gastric emptying time measurement of subject tests immediately after surgery and after 1 year or longer were twice. Preparation of the patient before the test is more than 12 hours of overnight fasting is important, in addition to the medicine or to stop smoking, and diabetes insulin injections should be early in the morning is ideal to test. Generally labeled with $^{99m}Tc-DTPA$ resin which is used to make steamed egg, seaweed and fermented milk with a high viscosity after eating, three hours in the standing position was measured. Evaluation of gastric emptying curves on the way intragastric radioactivity level by 50% the time (half-time [T1/2]) was calculated, based on the half-life was divided into three steps: over 180 minutes was defined as delayed gastric emptying, within 180minutes was defined as intermediate gastric emptying and when all the radioisotopes were dumped into the jejunum as soon as swallowed, was defined as rapid gastric emptying. Results: Gastric emptying time of a typical images stomach of antrum and fundus additional images appear stronger over time move on to the small intestine. but esophageal cancer who underwent esophagectomy side of the thoracic cavity showed a strong image. Immediately after surgery, the half-time (T1/2) of rapid gastric emptying appeared to 12.9%, intermediate gastric emptying appeared to 52.7%, delay gastric emptying appeared to 34.4%. After more than a year the results of the half-life after surgery, 67% of rapid gastric emptying to intermediate gastric emptying was changed, 69% of delay gastric emptying to intermediate gastric emptying changed. Intermediate gastric emptying worse in patients rapid gastric emptying and the delay gastric emptying is 24% in the case. Conclusion: Esophagectomy for esophageal cancer who underwent half-time measurement test (T1/2) rapid gastric emptying and delay gastric emptying are the result of the comparison over time, changes were observed intermediate gastric emptying. Mainly seeing of gastric emptying time measurement in the esophagus instead of thoracic cavity to check the evaluation of gastrointestinal function can be useful even means. And segmentation criteria and narrow time interval of checking if more accurate information and analysis of the clinical diagnosis and evaluation seems to be done.

  • PDF

Evaluation after Applicated a Mold to a Paraneoplastic Autoimmune Multiorgan Syndrome Patient with Hypervascular Ulcer in the Oral Cavity during Treatment with Mold Brachytherapy (Paraneoplastic Autoimmune Multiorgan Syndrome으로 인하여 구강 내 국소적으로 발생한 과다혈관성 궤양의 방사선 근접치료 시 자체 제작한 Mold의 유용성 평가)

  • Park, Ju-Kyeong;Lee, Sun-Young;Lim, Seok-Geon;Kwak, Geun-Tak;Lee, Seung-Hun;Kim, Yang-Su;Hwang, Ho-In;Cha, Seok-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.25-31
    • /
    • 2009
  • Purpose: Evaluate the mold we have made to improve the reproducibility of the patient position and make homogeneous dose distribution to the treatment volume effectively when treating the patient who has hypervascular ulcer on her tongue caused by paraneoplastic autoimmune multiorgan syndrome by mold brachytherapy. Materials and Methods: The mold is consisted of upper and lower parts. We inserted 2 mm of lead sheet on the gums toward the oral cavity to protect them from unnecessary irradiation during the treatment. We had planned on orthogonal images obtained the patient. 200 cGy was delivered in every fraction with a total dose of 3000 cGy. To evaluate the effect of the lead sheet, we made a measurement with a phantom that has gums and tongue made of tissue with an equivalent material (bolus). Five of TLDs were placed on the interesting points of gums to measure the dose during irradiation with lead sheet and without lead sheet for three times respectively. Results: The result of the measurement without lead sheet are A: 33.9 cGy, B: 30.1 cGy, C: 31.8 cGy, D: 23.3 cGy, E: 24.1 cGy. The results of measurement with lead sheet are A: 20.6 cGy, B: 18.8 cGy, C: 19.6 cGy, D: 14.7 cGy, E: 15.1 cGy. Conclusion: Since we are using the mold made in our department during the treatment of the patient with hypervascular ulcer on tongue, we could deliver a proper dose to the treatment volume. In addition, the mold provided highly accurate and reproducible treatment and reduced the dose to the gums and teeth. Therefore, the possibility of side effects could be decreased significantly.

  • PDF

Development of an Offline Based Internal Organ Motion Verification System during Treatment Using Sequential Cine EPID Images (연속촬영 전자조사 문 영상을 이용한 오프라인 기반 치료 중 내부 장기 움직임 확인 시스템의 개발)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Huh, Woong;Kim, Min-Kyu;Han, Young-Yih;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jing-Sung;Park, Hee-Chul;Ahn, Sung-Hwan;Lim, Do-Hoon;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.91-98
    • /
    • 2012
  • Verification of internal organ motion during treatment and its feedback is essential to accurate dose delivery to the moving target. We developed an offline based internal organ motion verification system (IMVS) using cine EPID images and evaluated its accuracy and availability through phantom study. For verification of organ motion using live cine EPID images, a pattern matching algorithm using an internal surrogate, which is very distinguishable and represents organ motion in the treatment field, like diaphragm, was employed in the self-developed analysis software. For the system performance test, we developed a linear motion phantom, which consists of a human body shaped phantom with a fake tumor in the lung, linear motion cart, and control software. The phantom was operated with a motion of 2 cm at 4 sec per cycle and cine EPID images were obtained at a rate of 3.3 and 6.6 frames per sec (2 MU/frame) with $1,024{\times}768$ pixel counts in a linear accelerator (10 MVX). Organ motion of the target was tracked using self-developed analysis software. Results were compared with planned data of the motion phantom and data from the video image based tracking system (RPM, Varian, USA) using an external surrogate in order to evaluate its accuracy. For quantitative analysis, we analyzed correlation between two data sets in terms of average cycle (peak to peak), amplitude, and pattern (RMS, root mean square) of motion. Averages for the cycle of motion from IMVS and RPM system were $3.98{\pm}0.11$ (IMVS 3.3 fps), $4.005{\pm}0.001$ (IMVS 6.6 fps), and $3.95{\pm}0.02$ (RPM), respectively, and showed good agreement on real value (4 sec/cycle). Average of the amplitude of motion tracked by our system showed $1.85{\pm}0.02$ cm (3.3 fps) and $1.94{\pm}0.02$ cm (6.6 fps) as showed a slightly different value, 0.15 (7.5% error) and 0.06 (3% error) cm, respectively, compared with the actual value (2 cm), due to time resolution for image acquisition. In analysis of pattern of motion, the value of the RMS from the cine EPID image in 3.3 fps (0.1044) grew slightly compared with data from 6.6 fps (0.0480). The organ motion verification system using sequential cine EPID images with an internal surrogate showed good representation of its motion within 3% error in a preliminary phantom study. The system can be implemented for clinical purposes, which include organ motion verification during treatment, compared with 4D treatment planning data, and its feedback for accurate dose delivery to the moving target.

EFFECT OF PULSED ELECTROMAGNETIC FIELD STIMULATION ON THE EARLY BONE CONSOLIDATION AFTER DISTRACTION OSTEOGENESIS IN RABBIT MANDIBLE MODEL (가토 하악골 골신장 후 맥동전자기장이 조기 골경화에 미치는 효과에 대한 연구)

  • Hwang, Kyung-Kyun;Cho, Tae-Hyung;Song, Yun-Mi;Kim, Do-Kyun;Han, Sung-Hee;Kim, In-Sook;Hwang, Soon-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.2
    • /
    • pp.123-131
    • /
    • 2007
  • Introduction: Distraction osteogenesis is widely used as for bone lengthening in patients with maxillofacial deformity and alveolar bone atrophy. One of the major problems in distraction osteogenesis is long consolidation period for 2-3 months, in which the devices have to be fixed on the bone to prevent relapse. It results in scar formation on the face, disturbance of mastication and speech. This study was performed to evaluate the stimulating effect of pulsed electromagnetic field on the early bone consolidation in distraction osteogenesis. Materials and methods: Total 10 rabbit were used (5 for control group, 5 for experimental group). A vertical osteotomy in the mandibular body was performed and the distraction device was fixed. After 5 days distraction was done 1mm per a day for 7 days. A pulsed electromagnetic field (38 Gauss, 60 Hz) was applied for 8 hours per day and it continued for 5 days immediately after distraction in the experimental group. Both groups were sacrificed after 2 weeks. Histological specimens with H&E and Masson Trichrome staining were made and histomorphometrically analysed with image analyser. Results: The device for distraction osteogenesis was displaced in one animal for each group, therefore, only four animals in both groups were evaluated. In both groups, a new bone formation was observed in the distracted area after 2 weeks. The bone formation was enhanced in the experimental groups ($31.76{\pm}8.68%$) compared with control group ($9.94{\pm}3.23%$), its difference was statistically significant (p<0.001). Conclusion: This study suggests that electrical stimulation with electromagnectic field may be effective in the early bone formation after distraction osteogenesis. Further studies with large number of animals are needed before clinical application.

Development of Predicting Models of the Operating Speed and Operating environment Satisfaction Model in Expressways (고속도로의 주행속도예측 및 주행환경만족도 모형 개발에 관한 연구)

  • Kim, Jang-Uk;Jang, Il-Jun;Kim, Jeong-Hyeon;Lee, Su-Beom
    • Journal of Korean Society of Transportation
    • /
    • v.27 no.2
    • /
    • pp.117-131
    • /
    • 2009
  • When most drivers take to the freeway, they don't necessarily pay attention to the geometric design. They expect proper design by depending on their own senses and recognition. When they evaluate the features of traveling on the freeway, they can think differently than engineers. The design needs to predict the exact speed of the driver to satisfy the driver's expectation, safety, pleasure and so on. This study categorized the factors influencing the speed of six freeways considering geometric and operational features to make a prediction model of speed. The model used multiple regression with these factors and produced statically appropriate results. This study utilized the principle component analysis and the quantification II analysis based on the image data of the satisfaction of the traveling environment collected through individual interviews. As a result, this study found the factors of satisfaction in a traveling environment. It made a satisfaction model of the traveling environment on freeways considering the change of driver's actual recognition and societal recognition using structural equations and the quantification II theory. Through the model made in this study, This model can present not only qualitative factors like satisfaction of traveling environment on freeways, but also the quantitative elements like speed. What is important is the evaluation of features of traveling on freeways reflected in the recognition and traffic environment felt by drivers.

Public Art and Urban Reimagineering : An Evaluation of Busan Biennale 2006 (공공예술과 도시 재이미지화 : 2006 부산 비엔날레 평가)

  • Choi, Byung-Doo
    • Journal of the Korean association of regional geographers
    • /
    • v.13 no.5
    • /
    • pp.543-562
    • /
    • 2007
  • Busan Biennale, began from 2000, has been argued that it would improve 'intrinsic introspection related to localism' against 'a lifestyle forced by capitalism in a global dimension', by promoting urban esthetic imagination in the public sphere of the city and reflecting it upon exhibited artworks. But Busan Biennale seems to reflect partly an attempt for new place marketing or urban reimagineering as a part of postmodern culture, even thought it has been planned to be an authentic stage or public-place art for citizens. This paper is to examine Busan Biennale 2006, held from Sep.16 to Nov.25 in Busan main theme of which is 'everywhere', constituted with three major projects: the Contemporary Art Exhibition, Sea Art Festival, and the Busan Sculpture Project. Ths paper considers first some implications of the transformation of modem to postmodern city, focusing on spatial representation of the city and public place art, and then tries to evaluate whether Busan Biennale is really embedded in the local authenticity and esthetic imagination for citizen or not. As concluding remarks, this paper suggests that Busan Biennale would be continuously developed, when it is oriented more towards local public-place art for citizens with their active participations rather than towards urban reimagineering strategy to make and promote an image of Busan as a global city.

  • PDF

Retrospective Evaluation of Risk Factors and Immunohistochemical Findings for Pre-Neoplastic and Neoplastic lesions of Upper Urinary Tract in Patients with Chronic Nephrolithiasis

  • Desai, Fanny Sharadkumar;Nongthombam, Jitendra;Singh, Lisam Shanjukumar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8293-8298
    • /
    • 2016
  • Background: Urinary stones are known predisposing factors for upper urinary tract carcinoma (UUTC) which are commonly detected at advanced stage with poor outcome because of rarity and lack of specific criteria for early detection. Aims and objectives: The main aim was to evaluate the impact of age, gender andstone characteristics on risk of developing UUTC in patients with chronic nephrolithiasis. We also discuss the role of aberrant angiogenesis (AA) and immunohistochemical expression of p53, p16INK4a, CK20 and Ki-67 in diagnosis of pelvicalyceal neoplastic (NL) and pre-neoplastic lesions (PNL) in these patients. Materials and Methods: Retrospective analysis of pelvicalyceal urothelial lesions from 88 nephrectomy specimens were carried out in a tertiary care centre from June 2012 to December 2014. Immunohistochemistry (IHC) was performed on 37 selected cases. Computed image analysis was performed to analyse aberrant angiogenesis. Results: All UUTC (5.7%) and metaplastic lesions were found to be associated with stones. Some 60% were pure squamous cell carcinoma and 40% were transitional cell carcinoma. Odd ratios for developing NL and PNL lesions in presence of renal stone, impacted stones, multiple and large stag horn stones were 9.39 (95% CI 1.15-76.39, p value 0.05), 6.28 (95% CI 1.59-24.85, p value 0.000) and 7.4 (95% CI, 2.29-23.94, p value 0.001) respectively. When patient age was ${\geq}55$, the odds ratio for developing NL was 3.43 (95% CI 1.19-9.88, p value 0.019). IHC analysis showed that mean Ki-67 indices were $3.15{\pm}3.63%$ for non-neoplastic lesions, $10.0{\pm}9.45%$ for PNL and $28.0{\pm}18.4%$ for NL. Sensitivity and specificity of CK20, p53, p16INK4a, AA were 76% and 95.9%; 100% and 27.5%; 100% and 26.5%; 92.3 % and 78.8% respectively. Conclusions: Age ${\geq}55years$, large stag horn stones, multiple stones and impacted stones are found to be associated with increased risk of NL and PNL in UUT. For flat lesions, a panel of markers, Ki 67 index >10 and presence of aberrant angiogenesis were more useful than individual markers.

The Effect of Dose Distribution under Treatment Techniques on Cerebrospinal Irradiation (뇌 및 척수조사시 치료기법의 변화가 선량분포에 미치는 영향)

  • Lee, Seungchul;Kim, Youngjae
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.21-28
    • /
    • 2016
  • This study tries to evaluate the usefulness CSI treatment. Compare the standard technique and simple technique, using the volume region of a high dose of Field joints (hot spot) or low dose regions (cold Spot). In patients who agreed to this study, obtain CT image using CT simulator skull to pelvis region. Standard Technique were performed on the movement of the joint radiation field range and simple technique has set a treatment plan to secure the radiation field range and analyzed treatment planning. Under analysis standard technique occurred the area of the high dose(Hot Spot) for the area overlapping the field and simple technique showing a uniform doses. CI indices of standard technique and simple technique was 1.6~3, 1.6~1.87, CN indices was 0.32~0.53, 0.46~0.51 and HI indices was 0.11~0.33, 0.2~0.26. Therefore, adjacent to part of the dose distribution junction more equally than simple technique compared to the Standard Technique. Compare the dose distribution patterns using CI, CN, HI indices, showed a uniform dose distribution in the simple technique. so, simple technique was determined appropriate treatment the CSI.

MTF Evaluation according to change in posture and channel during CT examination for wrist Joint : X-axis and Z-axis changes around Isocenter (손목관절 CT 검사 시 자세 변화와 채널 변경에 따른 MTF 평가 : Isocenter를 중심으로 X-축, Z-축 변화)

  • Seo, Min Jae;Lim, Jong Chon;Jung, Dabin;Han, Dong Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.811-817
    • /
    • 2020
  • This study aims to evaluate the Modulation Transfer Function (MTF) according to the change in the number of channels of the CT examination device by changing the posture of the patient to the X-axis and Y-axis in the wrist joint CT examination. Using a CT device and a wrist phantom, the test was performed by moving 0 (matched), 5, 10, and 15 cm in the X-axis around the isocenter, and the Z-axis was rotated by -20° and -40°. For the test, 16, -40 and 64 channels were used to check whether there was a difference for each number of channels. The examined images were compared by measuring the MTF values of the ulna and left and right sides of the radius. In the experiment where the isocenter was moved along the X-axis, the MTF value decreased with an increase in the moving distance, and the MTF value was found to be unaffected by the number of channels. In the experiment in which the wrist joint was rotated by -20° and -40° on the Z-axis, the degree of deviation and MTF were found to be irrelevant. It was not related to the number of channels either. In conclusion, the movement of the wrist along the X-axis should be restrained as much as possible for a wrist joint CT scan, whereas deviation around the Z-axis depending on the environment for the patient would not affect the MTF of the image.