• Title/Summary/Keyword: etching solution.

Search Result 531, Processing Time 0.029 seconds

Study of metal dopants and/or Ag nanoparticles incorporated direct-patternable ZnO film by photochemical solution deposition

  • Kim, Hyun-Cheol;Reddy, A.Sivasankar;Park, Hyung-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.368-368
    • /
    • 2007
  • Zinc oxide (ZnO) has drawn much interest as a potential transparent conducting oxide (TCO) for applying to solar cell and front electrode of electro-luminescent devices. For the enhancement of electrical property of TCOs, dopant introduction and hybridization with conductive nanoparticles have been investigated. In this work, ZnO films were formed on glass substrate by using photochemical solution deposition of Ag nanoparticles dispersed or various metal (Ag, Cd, In, or Sn) contained photosensitive ZnO solutions. The usage of photosensitive solution permits us to obtain a micron-sized direct patterning of ZnO film without using conventional dry etching procedure. The structural, optical, and electrical characteristics of ZnO films with the introduction of metal dopants with/without Ag nanoparticles have been investigated to check whether there is a combined effect between metal dopants and Ag nanoparticles on the characteristics of ZnO film. The phase formation and crystallinity of ZnO film were monitored with X-ray diffractometer. The optical transmittance measurement was carried out using UV-VIS-NIR spectrometer and the electrical properties such as sheet resistance and conductivity were observed by using four-point probe.

  • PDF

SHEAR BOND STRENGTH OF ORTHODONTIC BONDING RESINS TO PORCELAIN; AN IN VITRO STUDY (도재에 대한 교정용 브라켓 접착 레진의 전단접착강도에 관한 연구)

  • Ko, Jin-Hwan;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.22 no.1
    • /
    • pp.43-65
    • /
    • 1992
  • Bonding orthodontic adhesive resins to glazed porcelain surface is not attainable. The aim of this investigation was to examine, in vitro, the effect of three methods of porcelain surface pretreatment on the shear bond strength of orthodontic adhesives, and to compare the shear strength of orthodontic bracket bonding to porcelain surface by the best results that to human enamel. Porcelain disks ($Ceramco^{(TM)}$ and $Vita^{(TM)}$) baked in the laboratory were roughened by sandpapers, #320, #600, #800, #1000 and #1200, and were pretreated with silane and dried at the various temperatures, room temperature, $50^{\circ}C$, $70^{\circ}C$ and $90^{\circ}C$, and were etched by 3% hydrofluoric acid solution for 1, 3, 5, 7, and 9 minutes, orthodontic adhesives (System $1+^{(TM)}$ and $Unite^{(TM)}$) were applied on them, and shear bond strengths were measured by Instron. The best results of pretreatment of each method were determined by the shear bond strengths. Again, porcelain disks were pretreated by the determined best results and human enamel were etched by 37% hydrofluoric acid solution, orthodontic brackets were bonded on them by the orthodontic adhesives, and the shear bond strengths were measured and compared between them. 1. Roughening porcelain surfaces with coarse sandpaper (#300) showed higher shear bond strength than that with finer sandpapers, but it $(22.44Kgf/cm^2)$ was distinguishably low compared to that from etched human enamel $(144.11Kgf/cm^2)$. 2. There were disparities in shear bond strengths upon the orthodontic resins, which was presumably related to the contents of fillers in orthodontic adhesive resins. Also there were disparities in shear bond strength upon the porcelains which had different composition. 3. Silane enhanced the shear bond strength of orthodontic resins to porcelain surfaces ($25.20Kgf/cm^2$ at $50^{\circ}C$), which was markedly low compared to that from etched human enamel. 4. Etched porcelain surface with 3% hydrofluoric acid solution for 1 to 9 minutes showed no difference in shear bonding strength of orthodontic adhesive resins. Shear bond strength from etched porcelain $(97.43-120.72Kgf/cm^2)$ were as high as clinically available, but low compared to that from etched human enamel. 5. Roughening with #300 sandpaper and etching by 3% hydrofluoric acid followed silane application on porcelain surface showed lower shear bond strength than etched human enamel, but were as high as clinically useful. 6. The results suggest that etching porcelain surface by 3% hydrofluoric acid solution might provide comparatively high shear bond strength as much as clinically favorable.

  • PDF

A Study on the Corrosion Susceptibility and Corrosion Fatigue Characteristics on the Material of Turbine Blade (Turbine Blade재료의 부식민감성과 부식피로특성에 관한 연구)

  • Jo, Seon-Yeong;Kim, Cheol-Han;Ryu, Seung-U;Kim, Hyo-Jin;Bae, Dong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.3 s.174
    • /
    • pp.603-612
    • /
    • 2000
  • Corrosion characteristics on the 12Cr alloy steel of turbine blade was electro-chemically investigated in 3.5wt% NaCI and 12.7wt% Na2S04 solution, respectively. Electro-chemical polarization test, Huey test and Oxalic acid etching test were previously conducted to estimate corrosion susceptibility of the material. And, using the horizontal corrosion fatigue tester, corrosion fatigue characteristics of 12Cr alloy steel in distilled water, 3.5wt% NaCI solution, and 12.7wt%(1M) Na2S04 solution were also fracture-mechanically estimated and compared their results. Parameter considered was room temperature, 60'C and 90'C. Corrosion fatigue crack length was measured by DC potential difference method.Obtained results are as follows,1) 12Cr alloy steel showed high corrosion rate in 3.5wt% NaCI solution and Na2S04 solution at high tempratue.2) Intergranular corrosion sensitivity of 12 Cr alloy was smaller than austenitic stainless steel.3) Corrosion fatigue crack growth rate in 3.5wt% NaCI and 12.7wt%(IM) Na2S04 solution is entirely higher than in the distilled water, and also increased with the temperature increase.

INFLUENCE OF THE ENAMEL TREATMENT WITH ER:YAG LASER ON THE MICROLEAKAGE OF PIT AND FISSURE SEALANT (Er:YAG 레이저를 이용한 법랑질 표면처리가 치면열구전색제의 미세누출에 미치는 영향)

  • Lee, Ji-Hyun;Kim, Jae-Moon;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.192-200
    • /
    • 2006
  • The aim of this study was to assess the microleakage underneath a pit and fissure sealant bonded to occlusal surfaces treated by Er:YAG laser To determine the most effective energy density of laser, fourteen specimens were irradiated from 50mJ to 300mJ at 3Hz. After irradiation, the lased specimens were observed under the scanning electron microscope. Thirty six non-carious extracted premolars were randomly assigned to four groups of nine teeth: group 1, no treatment on the occlusal surface; group 2, acid etching for 15 seconds; group 3, Er:YAG laser irradiation; group 4, acid etching followed by Er:YAG laser irradiation. The pits and fissures were sealed with unfilled sealant(Helioseal F) and the specimen teeth were thermo-cycled, immersed in 2% Rhodamine B solution, longitudinally sectioned and analyzed for microleakage with fluorescent microscope. The results were as follows: 1. Er:YAG lased surfaces with 50mJ, 3Hz showed a similar pattern of irregularity with acid etched enamel surfaces 2. The mean microleakage score increased in the order of group 2, 4, 3 and 1. There was no significant difference among group 1, 3 and 4(p>0.05), however group 2 showed significantly less microleakage compared with group 1 and 3. Conclusively, the laser irradiation seemed not enough to replace the acid etching for proper retention of pit and fissure sealants.

  • PDF

EFFECTS OF ACID TREATMENT OF FLUORIDE APPLIED DENTIN SURFACE ON DENTIN BONDING (불소도포한 상아질면의 산처리가 상아질접착에 미치는 영향)

  • Hwang, Hea-Kyung;Ahn, Sik-Hwan;Kim, Sung-Kyo;Jo, Kwang-Hun;Park, Jin-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.2
    • /
    • pp.602-618
    • /
    • 1996
  • The purpose of this study was to investigate the effect of acid treatment of fluoride applied dentin surface with various concentrations of phosphoric acid for various periods of time on dentin bonding. Dentin specimens prepared from freshly extracted bovine mandibular anterior teeth were divided into fluoridated and nonfluoridated groups. Specimens of nonfluoridated group were pretreated with 10% phosphoric acid for 15 seconds. Those of fluoridated groups were treated with 2% sodium fluoride or 2% stannous fluoride solution for 5 minutes and stored in $37^{\circ}C$ distilled water for 3 days, followed by phosphoric acid treatment. The concentrations of phosphoric acid were 10%, 32% or 50% and the treatment periods of time were 15, 30 or 60 seconds. All the specimens were bonded with All Bond$^{(R)}$ 2 and Bisfil$^{TM}$ composite resin. After bonded specimens were stored in $37^{\circ}C$ distilled water for 24 hours, tensile bond strengths of each specimens were measured and the pretreated dentin and the fractured dentin surfaces were examined under the scanning electron microscope. The results were as follows : The tensile bond strengths from the fluoridated groups were significantly lower than those from the nonfluoridated group when the concentrations of phosphoric acid and the treatment periods of time were equal in all the groups (p<0.05). In general, the higher the concentration of phosphoric acid and the longer the treatment period of time for acid etching on the fluoride applied dentin surface, the higher were the bond strength values. Recovery of bond strength of the dentin bonding agent was better in the NaF applied group than in the $SnF_2$ applied one. SEM findings of NaF applied and $SnF_2$ applied dentin surfaces demonstrated reaction product-covered and partially or completely obstructed dentinal tubules. SEM findings of dentin surfaces fluoridated for 5 minutes followed by etching showed wider tubular openings and more clean dentin surfaces when dentin was etched with higher concentration of phosphoric acid for longer period of time. On the SEM observations of the fractured dentin-resin interface, the etched specimens of fluoridated group showed an adhesive failure mode when the concentration of phosphoric acid and the treatment period of time were same as in the nonfluoridated group. As the concentration of phosphoric acid and the treatment period of time increase during acid etching, the cohesive failure area increased. However, excessive acid etching caused adhesive failure.

  • PDF

Study of Aging and Durability on Plasma Polymerized Tire Cords (플라즈마 중합 코팅된 타이어 코드의 노화에 따른 접착력 변화 연구)

  • Kang, H.M.;Yoon, T.H.
    • Journal of Adhesion and Interface
    • /
    • v.4 no.1
    • /
    • pp.28-34
    • /
    • 2003
  • Steel tire cords were subjected to plasma polymerization coating of acetylene in order to enhance the adhesion to rubber compounds. Plasma polymerization coating was varied to plasma polymerization coating of acetylene, argon plasma etching+plasma polymerization, or argon plasma. etching+plasma polymerization with Ar carrier gas. Adhesion was evaluated via TCAT samples and compared to those with brass coated tire cord. For durability study, plasma polymer cooled tire cords were aged in lab atmosphere for 1, 3, 5, 10 or 15 days, while TCAT specimens prepared with plasma polymer coated tire cords were aged in distilled water, 10% NaCl solution or $100^{\circ}C$ oven for 1, 2, 3 or 4 weeks. After testing, failure surfaces were analyzed with SEM/EDX. Among the treatments, the highest adhesion was obtained by Ar etching+acetylene plasma. polymerization coating with Ar carrier gas, providing almost same pull-out force as the brass coated tire cords. Upon the aging of the tire cords in the lab atmosphere, brass coated tire cords provided better adhesion than plasma polymer coated tire cords, while the TCAT samples with plasma polymer coated tire cords exhibited similar or slightly superior durability to those with brass coated tire cords.

  • PDF

The Effects of Dielectric Coatings on Electron Emission from Tungsten

  • Al-Qudah, Ala'a M.;Alnawasreh, Shady S.;Madanat, Mazen A.;Trzaska, Oliwia;Matykiewicz, Danuta;Alrawshdeh, Saad S.;Hagmann, Mark J.;Mousa, Marwan S.
    • Applied Microscopy
    • /
    • v.47 no.1
    • /
    • pp.36-42
    • /
    • 2017
  • Field electron emission measurements were performed on dielectric-coated tungsten emitters, with apex radii in the nanometer and micrometer range, which were prepared by electrochemical etching in NaOH solution. Measurements were performed in a field electron microscopy (FEM) with a base pressure <$10^{-6}$ Pascal ($10^{-8}$ mbar). Four different types of dielectric were used, namely: (1) Clark Electromedical Instruments epoxylite resin, (2) Epidian 6 produced by Ciech Sarzyna S. A., (3) a Radionox solution of colloidal graphite; and (4) Molyslip 2001 E compound ($MoS_2$ and MoS). Current-voltage measurements and FEM images were used to investigate the characteristics of these composite emitters, and to assess how the different types of dielectric coating affect the suitability of the composite emitter as a potential electron source.

Electrochemical Properties of Metal Aluminum and Its Application (금속알루미늄의 전기화학적 성질과 응용)

  • Tak, Yongsug;Kang, Jinwook;Choi, Jinsub
    • Applied Chemistry for Engineering
    • /
    • v.17 no.4
    • /
    • pp.335-342
    • /
    • 2006
  • Metal aluminum, of which has a low standard reduction potential, participates in the electrochemical oxidation reaction and results in the structural change and accompanying property variation of aluminum and its oxide film. Aluminum was electrochemically etched in acid solution and the surface area was magnified by the formation of high density etch pits. Etched aluminum was covered with a compact and dense dielectric oxide film by anodization and applied to the capacitor electrode. Anodization of aluminum in acid solution at low temperature makes a nanoporous aluminum oxide layer which can be used for the fabrication template of nanostructural materials. Electrochemical characteristics of aluminum turn the metal aluminum into functional materials and it will bring the diverse applications of metal aluminum.

Effect on the Pyramid Structure with Saw Mark Density of Silicon Wafer Surface (실리콘 웨이퍼 표면의 saw mark 밀도에 따른 피라미드 구조의 영향)

  • Lee, Min Ji;Park, Jeong Eun;Lee, Young Min;Kang, Sang Muk;Lim, Donggun
    • Current Photovoltaic Research
    • /
    • v.5 no.2
    • /
    • pp.59-62
    • /
    • 2017
  • Surface texturing is affected the uniformity and size of pyramid with saw mark defect density. To analysis the influence of the saw mark defect density, we textured various si wafer. When the texturing process proceeds without the saw mark removal, silicon wafer of low-saw mark defect density showed small pyramid size of $3.5{\mu}m$ with the lowest average value of the reflectance of 10.6%. When texturing carried out after removal of the saw mark using the TMAH solution, we obtained a reflectance of about 11% and the large pyramid size of $5{\mu}m$. As a result, saw mark wafers showed a better pyramid structure than saw mark-free wafer. This result showed that saw mark can take place more smooth etching by the KOH solution and saw mark-free wafer is determined to be a factor that have a higher reflectance and a large pyramid.

Analysis of mixture experimental data with process variables (공정변수를 갖는 혼합물 실험 자료의 분석)

  • Lim, Yong-B.
    • Journal of Korean Society for Quality Management
    • /
    • v.40 no.3
    • /
    • pp.347-358
    • /
    • 2012
  • Purpose: Given the mixture components - process variables experimental data, we propose the strategy to find the proper combined model. Methods: Process variables are factors in an experiment that are not mixture components but could affect the blending properties of the mixture ingredients. For example, the effectiveness of an etching solution which is measured as an etch rate is not only a function of the proportions of the three acids that are combined to form the mixture, but also depends on the temperature of the solution and the agitation rate. Efficient designs for the mixture components - process variables experiments depend on the mixture components - process variables model which is called a combined model. We often use the product model between the canonical polynomial model for the mixture and process variables model as a combined model. Results: First we choose the reasonable starting models among the class of admissible product models and practical combined models suggested by Lim(2011) based on the model selection criteria and then, search for candidate models which are subset models of the starting model by the sequential variables selection method or all possible regressions procedure. Conclusion: Good candidate models are screened by the evaluation of model selection criteria and checking the residual plots for the validity of the model assumption. The strategy to find the proper combined model is illustrated with examples in this paper.