• Title/Summary/Keyword: esthetic values

검색결과 97건 처리시간 0.023초

광중합형 복합레진과 콤포머의 두께와 배경색에 따른 색변화 (THE COLOR CHANGE OF VISIBLE LIGHT-CURED COMPOSITE RESINS AND COMPOMERS ACCORDING TO THE THICKNESS AND BACKGROUND COLOR)

  • 임주환;한진순;이수종;임미경
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.71-77
    • /
    • 2000
  • The color of an esthetic restorative material is controlled primarily by thickness of the material and background color. Although the effects of the two factors on the color coordinates of esthetic dental materials have been reported, the mechanism has not been clarified well enough to explain the effects quantitatively. The purpose of this study was to evaluate the effect of thickness and background color on the color of tooth colored restorative materials quantitatively. One hundred sixty samples were fabricated from two commercial light-cured composite resins and two commercial compomers. The color characteristics and changes in the color coordinates were measured by a tristimulus colorimeter (Model TC-6FX, Tokyo Denshoku Co. Japan) using the CIELAB system. The results were as follows: 1. As thickness increased from 1.0 to 4.0mm, values of $L^*$ $a^*$ $b^*$ changed irregulary for white and dentin color background, but showed no obvious difference in color for black background. 2. The colors of composite resins and compomers were significantly influenced by background color. 3. The color difference was recognized even the same shade name in four representative kinds of composite resins and compomers. 4. As thickness changed, values of color difference for same products and same background color showed constancy, but showed difference for different background color.

  • PDF

청소년잡지에 나타난 화장품광고의 소구유형 및 소비가치의 변화에 관한 연구 (A Study on the Changes of Advertising Appeals and Consumption Values of Cosmetic Advertisements in Adolescent′s Magazines)

  • 김희숙
    • 한국의류학회지
    • /
    • 제26권3_4호
    • /
    • pp.492-502
    • /
    • 2002
  • The purpose of this study was to investigate the advertising appeals and consumption values expressed on cosmetic advertisements in Adolescent's magazines from 1973 to 2000. The data for longitudinal content analysis were collected from Adolescent's magazine : Junior Joongang(1973.3∼1985.12), Highteen(1986.1∼1994.9), Cci(1994.l0∼2000.12). Collected data was consisted of 542 advertisements. 1. The product categories in cosmetics advertisements, the major were Base Make-up in the past but the number of Color Make-up, Functional Make-up, and Hair-related Products had increased in 1990s. Also, there were more increasing number of imported products than domestics. 2. The trend of appeals showed change according to time and society. Overall, a great many of cosmetic advertisements had emotional approach. Before the middle of the 1980's emotional approach had decreased, and mixed(rational and emotional) approach were dominated in 1990s. 3. The major consumption values in cosmetics advertisements were effective value. Especially, it had increased from 1990s. And esthetic value was dominated in the middle of the 1970s.

광중합복합레진의 두께에 따른 투명도 차이가 수복물의 색상에 미치는 영향 (TRANSLUCENCY OF LIGHT CURED COMPOSITE RESINS DEPENDS ON THICKNESS & ITS INFLUENCE ON COLOR OF RESTORATIONS)

  • 황인남;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.585-603
    • /
    • 1999
  • Esthetic availabilities used as an esthetic restorative maternals can be determined by the optical coincidence among materials, enamel and dentin. Enamel is highly translucent. That's why esthetic materials need to correspond the close translucency of enamel. But the translucent materials are affected by the background color. So it should be predicted that the color of estorative materials depend on the any thickness and the spectral reflectance of the background on which they are placed. The object of this investigation, under above hypothesis, was to determine and analyze how they affect the final color according to the thickness, translucency and background color (white, black and dentin) fill three commercial light cured composite resins(Charisma, Spectrum TPH and Z100). And correlation was analyzed to find out the possibility of the prediction when using the certain background color and thickness of materials. Followings are the result 1. The I shade of CHA showed the lowest contrast ratio($Co_7$) while the B3 shade of Z100 showed the highest contrast ratio(p<0.05). 2. The value of $L^*$ and $b^*$ on the white and dentin background is increased with decreasing thickness. And there are significant relationships between increasing thickness and each value(R>0.085). But there is a little change of $L^*$ and $b^*$ value on the black background regardless of the thickness(p>0.05). 3. For the $a^*$ value, there was little difference in values as a function of thickness and changed irregularly regardless of thickness in all background. 4. The pattern of increasing value of $L^*$ and $b^*$ with decreasing thickness was similar to the group of white and dentin background. In both dentin one showed lesser change of value. 5. The values of $L^*a^*b^*$ measured on the different background with same thickness showed the recognizable color difference(${\Delta}E^*$>2) when the thickness was below 2.6mm. 6. Contrast ratio was increased with increasing thickness with significant relationship (R>0.9). 7. Spectral reflectance of composite resins that calculated from Kubelka-Munk equation was showed little difference compared with observed value w1th decreasing thickness.

  • PDF

임플랜트 지대주의 삭제과정이 결합부 안정성에 미치는 영향 (THE EFFECT OF PREPARATION PROCEDURE ON IMPLANT-ABUTMENT JOINT STABILITY)

  • 이장욱;김창회;장경수;임영준
    • 대한치과보철학회지
    • /
    • 제43권5호
    • /
    • pp.662-670
    • /
    • 2005
  • Statement of problem: Little is known about the effect of abutment preparation procedure on do-torque values in different implant platform and the relationship of final do-torque values with different implant platform size. Purpose: This study evaluated the effect of abutment preparation procedure on do-torque values in different implant platform and the relationship of final do-torque values with different implant platform size. Material and method: Six ITI implants (2 narrow-neck implants, 2 regular-neck implants, 2 wide-neck implants) and six Branemark implants (2 narrow platforms, 2 regular platforms, 2 wide platforms) were embedded in each acrylic resin block with epoxy resin. Eighteen $synOcta^(R)$ abutments (6 narrow-neck implant-abutments, 6 regular-neck implant-abutments, 6 wide-neck implant-abutments) and eighteen esthetic abutments (6 narrow platform-abutments, 6 regular platform-abutments, 6 wide platform-abutments) were tightened to each implant with digital torque gauge. Initial do-torque values were measured using digital torque gauge. After preparation of abutments, Final do-torque values were measured with digital torque gauge. Results and conclusion: 1. Screws loosening or abutments motion were not detected in all experimental group, but some scratches of implant-abutment joints were detected in all group 2. Reduction ratios of final do-torque values were greater than initial do-torque values in all measured group, except in narrow-neck implant-abutment group (p<0.05). 3. Reduction ratios of final do-torque values in wide-neck implant-abutment group were greater than regular-neck implant-abutment group (p<0.01). 4. The greatest standard deviation value was detected in wide platform group in both implant systems.

포스트의 종류에 따른 Empress 2 도재관의 색상에 관한 비교연구 (COLOR COMPARISON OF VARIOUS POST SYSTEMS WITH EMPRESS 2 CROWNS)

  • 이영수;유동엽
    • 대한치과보철학회지
    • /
    • 제39권2호
    • /
    • pp.197-207
    • /
    • 2001
  • Development of new ceramics and esthetic needs of patients increase the use of all ceramic restorations. Fractured teeth often need metal post and core as foundation for final restoration. When all ceramic restorations are planned, metal post and core may lead to compromised esthetics because of opacity and gray color of metal post and core. Many techniques have been proposed to solve this problem such as application of an opaque porcelain to the metal core or all ceramic post and core. This study was performed to evaluate effect on color of Empress 2 crown according to various post systems. Color was evaluated by the CIE $L^*a^*b^*$ systems and measured by spectrophotometer (Model CM-3500, Minolta, Japan). Specimens were divided into 4 groups as follows Group 1 : gold cast post specimen + Empress 2 crown specimen Group 2 : application of an opaque porcelain to gold cast post specimen + Empress 2 crown specimen Group 3 : cosmopost specimen + Empress 2 crown specimen Group 4 : In-ceram post specimen + Empress 2 crown specimen. The results obtained as follows, 1. $L^*$ Values showed that group 2, 3, 4 were higher than group 1 with significant difference and group 2, 3, 4 were not significantly different. 2. $a^*$ Values and $b^*$ values also showed that group 2. 3, 4 were higher than group 1 with significant difference and group 2, 3, 4 were not significantly different. 3. ${\Delta}E^* ab$ Values showed that ${\Delta}E^* ab$ 3 was the highest value and ${\Delta}E^* ab$ 5 was the lowest value.

  • PDF

THE EFFECT OF THICKNESS OF THE PROVISIONAL CROWN AND FIXED PARTIAL DENTURE MATERIALS ON THE TRANSLUCENCY AND MASKING EFFECT

  • Jae, Hyun-Jee;Kim, Sung-Hun;Lee, Seok-Hyung;Pae, Ahran
    • 대한치과보철학회지
    • /
    • 제45권6호
    • /
    • pp.724-734
    • /
    • 2007
  • Statement of problem. Translucency and masking effect of provisional crown and fixed partial denture materials is an important esthetic consideration. But, provisional resin materials differ substantially in their ability to mask underlying colors. Purpose. The purpose of this study was to evaluate the translucency differences of provisional resin materials at various thicknesses and the correlation between the translucency and the masking efficiency. Material and methods. Two polymethyl methacrylate resins (Jet Tooth Shade, Alike) and three resin composites (Protemp 3 Garant, Luxatemp and Revotek LC) were used. Specimens (n=6) were fabricated from each material in 0.3, 0.5, 0.8, 1.0, 1.5, 2.0 and 3.0 mm thickness. The CIELAB parameters of each specimens were measured using a spectrophotometer. The translucency parameter (TP) values and the masking effect $({\Delta}ME^*{_{ab}})$ values were computed and all data were statistically analyzed by one-way ANOVA and the multiple comparisons Scheffe test. The correlation between the thickness and the TP values and the correlation between the thickness and the ${\Delta}ME^*{_{ab}}$ values were also evaluated by correlation analysis and regression analysis. Results. The TP values and the ${\Delta}ME^*{_{ab}}$ values were significantly related to the thickness in all specimens. The TP values were more sensitive to the change of thickness than the ${\Delta}ME^*{_{ab}}$ values. The order of the translucency by brand was different from the order of the masking effect by brand in all thickness groups. Conclusion. Within the limitations of this study, the translucency and masking effect of the provisional resin materials investigated were significantly related to their thickness. The masking effect of provisional resin was correlated with the translucency parameter, but the order of the masking effect by brand was different from the order of the translucency parameter.

동양회화에 있어서 형상관점의 심미 (The beauty of form in Oriental painting from a realistic point of view)

  • 정진룡
    • 조형예술학연구
    • /
    • 제6권
    • /
    • pp.119-139
    • /
    • 2004
  • The intention of the research is to look into the form reflecting the spiritual image due to Oriental aesthetic from a realistic point of view. In this regard, I will pay attention to examining the process from figurative perspectives, in which painting image by subject acquires the beauty of form. Of the main subjection this paper, figure is an image itself appearing in painting. At this point, I will attempt to show how the meaning and value of image have been interpreted and judged on the aesthetic standard in Oriental painting in particular. For this process, I generalize the conception of the image as 'figure' and through this I will reconsider the standard of understanding and the value of perception regarding painting images on the method which are more applicable to the expressions of Oriental painting. The reason why I try to find out the true nature of images in Oriental painting from a figurative viewpoint is to convert a conventional sense of value which recognizes the images of Oriental painting only as results of idealism, into more practical field. If the true nature of Oriental painting is fixed and restricted to natures of idealism, any productive development and any changes in form for future couldn't be expected at all. In fact, what the ideological and aesthetic values of art suggest is clearly a proof of real art form. However, it is not a hard thing to prospect that only a superficial idealism will be ceaselessly produced, while the practical study about aesthetic values, meaningful results of painting expressions, is totally ignored, if ideology itself is used as criteria to judge the identity of it or if only the idealistic aesthetic values are emphasized while any clue to show a real existence of oriental paintings is not certain. Actually, nobody can deny the fact that interests about real natures regarding art expressions have been relatively ignored while armed with mental ideology for esthetic view of oriental painting in traditionalism Therefore, it is clear that 'spiritual status' itself can generate any form. Traditionally, in the Orient, the standard of judging a real value of things, which put a focus on a spiritual view of value rather than on a materialistic view of it, has been vaguely positioned the identity of images in painting As a result, the aesthetic convention has finally committed to an error that for images of oriental painting, ideological criteria like so called spiritualism are applied as a judging way, and esthetic meanings and values of real painting are considered as strategic results and spiritual intentions.

  • PDF

Influence of different universal adhesives on the repair performance of hybrid CAD-CAM materials

  • Demirel, Gulbike;Baltacioglu, Ismail Hakki
    • Restorative Dentistry and Endodontics
    • /
    • 제44권3호
    • /
    • pp.23.1-23.9
    • /
    • 2019
  • Objectives: The aim of this study was to investigate the microshear bond strength (${\mu}SBS$) of different universal adhesive systems applied to hybrid computer-aided design/computer-aided manufacturing (CAD-CAM) restorative materials repaired with a composite resin. Materials and Methods: Four types of CAD-CAM hybrid block materials-Lava Ultimate (LA), Vita Enamic (VE), CeraSmart (CS), and Shofu Block HC (SH)-were used in this study, in combination with the following four adhesive protocols: 1) control: porcelain primer + total etch adhesive (CO), 2) Single Bond Universal (SB), 3) All Bond Universal (AB), and 4) Clearfil Universal Bond (CU). The ${\mu}SBS$ of the composite resin (Clearfil Majesty Esthetic) was measured and the data were analyzed using two-way analysis of variance and the Tukey test, with the level of significance set at p < 0.05. Results: The CAD-CAM block type and block-adhesive combination had significant effects on the bond strength values (p < 0.05). Significant differences were found between the following pairs of groups: VE/CO and VE/AB, CS/CO and CS/AB, VE/CU and CS/CU, and VE/AB and CS/AB (p < 0.05). Conclusions: The ${\mu}SBS$ values were affected by hybrid block type. All tested universal adhesive treatments can be used as an alternative to the control treatment for repair, except the AB system on VE blocks (the VE/AB group). The ${\mu}SBS$ values showed variation across different adhesive treatments on different hybrid CAD-CAM block types.

치과용 분광광도계를 이용한 상악 유전치의 색조 분포에 관한 연구 (Color distribution of maxillary primary incisors using a dental spectrophotometer in Korean children)

  • 송지수;신터전;현홍근;김영재;김정욱;장기택;이상훈
    • 대한치과의사협회지
    • /
    • 제58권8호
    • /
    • pp.476-485
    • /
    • 2020
  • The purpose of this study was to analyze the color distribution of the maxillary primary central and lateral incisors using a dental spectrophotometer. Color measurements of maxillary primary central and lateral incisors of 32 pediatric patients aged 2 to 6 years were performed using SpectroShade Handy Dental Type 713000 (Serial No. HDL2678, MHT, Verona, Italy) by one researcher in the same clinic. CIE L*, a*, b* values of total surfaces and cervical, middle, incisal region were recorded. L* values were higher and a* values were lower in the primary central incisors than those in primary lateral incisors, but b* values didn't show statistical difference. L* values of the middle region were the highest, and a* and b* values decreased from the cervical region to the incisal region. There were significant color differences between each region, and ΔE*ab between each region were greater than ΔE*ab between the primary central and lateral incisors. For esthetic restorations of primary incisors, it is necessary to consider the color differences between each region rather than those between the primary central and lateral incisors.

  • PDF

지르코늄 임플란트 지대주의 나사결합부 안정성에 관한 연구 (Screw Joint Stability under Cyclic Loading of Zirconia Implant Abutments)

  • 이미순;서규원;류재준
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.164-173
    • /
    • 2009
  • 연구 목적: 심미적 장점을 지닌 지르코니아 지대주와 금속 지대주 사이에 반복 하중 전, 후의 풀림 회전력을 비교하여 지대주 재질에 따른 나사 안정성에 차이가 있는지를 비교 분석해 보고자 하는 것이다. 연구 재료 및 방법: 실험군은 크게 외측 연결 구조(US II, Osstem Implant, Korea)와 내측 연결 구조(GS II, Osstem Implant, Korea)의 임플란트 시스템을 두 군으로 나누었다. 각각의 군에서 지르코니아 지대주군와 금속 지대주군으로 나누어 실험하였다. 각군당5개씩의 시편을 제작하였다. 임플란트 고정체를 별도 제작된 지그에 고정시킨다. 디지털 토크게이지를 이용하여 30 Ncm의 조임 회전력을 가하고 10분 후 동일 조임 회전력을 한번 더 적용하였다. 다음 각 지대주 나사의 초기 풀림 회전력을 디지털 토크게이지로 측정하였다. 동일 시편을 다시 30 Ncm의 조임 회전력을 가하여 체결한 후, 유압식 동적 재료시험기(Instron, USA)에 임플란트 매식체를 치과용 임플란트 피로시험에 관한 ISO/FPIS 14801:2003(E)규정을 참고하여 고정시켰다. 최소 하중은 10 N, 최대 하중은 250 N의 sine형 반복 하중을 $30^{\circ}$의 경사각도로, 하중 주기는 14 Hz로, 100만 회의 반복 하중을 적용한 후 풀림 회전력을 측정하였다. 결과: 1. 모든 시스템에서 지대주 나사의 풀림 회전력이 조임 회전력 보다 감소하였으나, 나사 풀림 현상은 나타나지 않았다. 2. 반복 하중 전과 후의 나사 풀림 회전력은 두 임플란트 시스템 모두에서 지르코니아 지대주가 금속 지대주보다 더 컸다(P<.05). 3. 반복 하중에 따른 풀림 회전력 상실률은 두 임플란트 시스템 모두에서 지르코니아 지대주와 금속 지대주가 차이가 없는 것으로 나타났다(P>.05). 4. 금속 지대주에서 반복 하중에 따른 풀림 회전력 상실률은 내측 연결 형태의 GS II 시스템이 외측 연결형태의 US II 시스템보다 작았다(P<.05). 5. 지르코니아 지대주에서는 반복 하중에 따른 풀림 회전력 상실률은 두 임플란트 시스템 간에 차이가 없는 것으로 나타났다(P>.05). 결론: 본 실험을 통해 100만회 반복 하중 하에서 지르코니아 지대주가 금속 지대주에 비해 나사 결합부 안정성이 더 크다는 결론을 내릴 수 있다.