• Title/Summary/Keyword: esthetic properties

Search Result 85, Processing Time 0.025 seconds

Biocompatibility study of lithium disilicate and zirconium oxide ceramics for esthetic dental abutments

  • Brunot-Gohin, Celine;Duval, Jean-Luc;Verbeke, Sandra;Belanger, Kayla;Pezron, Isabelle;Kugel, Gerard;Laurent-Maquin, Dominique;Gangloff, Sophie;Egles, Christophe
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.6
    • /
    • pp.362-371
    • /
    • 2016
  • Purpose: The increasing demand for esthetically pleasing results has contributed to the use of ceramics for dental implant abutments. The aim of this study was to compare the biological response of epithelial tissue cultivated on lithium disilicate ($LS_2$) and zirconium oxide ($ZrO_2$) ceramics. Understanding the relevant physicochemical and mechanical properties of these ceramics will help identify the optimal material for facilitating gingival wound closure. Methods: Both biomaterials were prepared with 2 different surface treatments: raw and polished. Their physicochemical characteristics were analyzed by contact angle measurements, scanning white-light interferometry, and scanning electron microscopy. An organotypic culture was then performed using a chicken epithelium model to simulate peri-implant soft tissue. We measured the contact angle, hydrophobicity, and roughness of the materials as well as the tissue behavior at their surfaces (cell migration and cell adhesion). Results: The best cell migration was observed on $ZrO_2$ ceramic. Cell adhesion was also drastically lower on the polished $ZrO_2$ ceramic than on both the raw and polished $LS_2$. Evaluating various surface topographies of $LS_2$ showed that increasing surface roughness improved cell adhesion, leading to an increase of up to 13%. Conclusions: Our results demonstrate that a biomaterial, here $LS_2$, can be modified using simple surface changes in order to finely modulate soft tissue adhesion. Strong adhesion at the abutment associated with weak migration assists in gingival wound healing. On the same material, polishing can reduce cell adhesion without drastically modifying cell migration. A comparison of $LS_2$ and $ZrO_2$ ceramic showed that $LS_2$ was more conducive to creating varying tissue reactions. Our results can help dental surgeons to choose, especially for esthetic implant abutments, the most appropriate biomaterial as well as the most appropriate surface treatment to use in accordance with specific clinical dental applications.

Effects of Esthetic Essential Oils on LPS-Induced Nitric Oxide Generation in Murine Marcrophage RAW 264,7 Cells (Medical Skin Care에서 사용빈도가 높은 Esthetic Essential Oils에 의한 Nitric Oxide 생성억제 효과)

  • Hong, Jin-Tae;Lee, Hwa-Jeong;Lee, Chung-Woo;Choi, Myoung-Suk;Son, Dong-Ju
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.32 no.2 s.57
    • /
    • pp.111-116
    • /
    • 2006
  • Essential oils have been used extensively in pharmacy, medicine, food, beverages, cosmetics, perfumery and aromatherapy. Although anti-bacteria, anti-virus, alleviation of fever operations and an anti-inflammatory properties have been reported, action mechanisms have not been fully discovered. In the present study, anti-inflammatory activities of thirty three essential oils have been evaluated in lipopolysaccharide (LPS)-treated macrophage RAW 264.7 cells by the evaluation of nitric oxide (NO) generation since NO generation is implicated in causal factor of inflammation. Among the tested 33 essential oil, Lemongrass oil showed the most inhibitory effect on LPS-induced NO generation in a dose dependent manner ($IC_{50}$ : $22 {\mu}g/mL$). In further study, it was found that Lemongrass oil inhibited the expression of inducible nitric oxide synthase. These results suggest that Lemongrass oil may be useful for improvements of the inflammatory disease such as pimple acne skin.

Shear bond strength and fracture patterns between Ormocer-based-resin and dentin (Ormocer-Based-Resin의 상아질에 대한 전단결합강도 및 파절 양상에 대한 연구)

  • Ahn, Shi-Hyun;Cho, In-Ho;Lim, Ju-Hwan;Lim, Heon-Song
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.4
    • /
    • pp.289-299
    • /
    • 2002
  • The bond strength is one of the most important factor in establishing long-term success of esthetic restorative dentistry. So, various restorative materials have been introduced to improve the esthetic and physical properties. Ormocer (organically modified ceramic) was developed as a result of such efforts. This study was performed to compare the shear bond strength of ormocer based adhesive with that of existing dentin adhesive. In this study $Admira^{(R)}$ and $Admira^{(R)}$ bond of the ormocer system are grouped together for ADM, Single $Bond^{(R)}$ which is an one-bottle adhesive and Z-250TM which is hybrid composite resin of BIS-GMA system for SIN, and $Definite^{(R)}$ of ormocer and Etch & $Prime^{(R)}$ 3.0 which is a self etching priming/ bonding agent for ETC. The results of this study were as follows. : (1) In the comparison of shear bond strength according to different adhesive system, shear bond strength was increased in the order of ETC group, SIN group, ADM group. There was no significant difference between ADM group and SIN group. However, there was a significant level of difference between ADM and ETC groups as well as SIN and ETC groups( p<0.05). (2) Examination by a scanning electron microscope showed a well established hybrid layer and resin tag in both ADM group and SIN group, while ETC group showed a minimal formation of the hybrid layer when compared with ADM and SIN groups. From the above results, it may be reasonable to start the clinical application of ormocer system, and it is recommended that ormocer system should be used along with an ormocer based adhesive because ormocer system showed the lower shear bond strength when it used with other existing self etching priming/bonding agent. The self etching priming/bonding agent showed relatively low shear bond strength, and it is considered that the further study should be needed.

The Linguistic Properties Comparison between nongifted children and Gifted children (일반아동과 영재아동의 언어적 특성 비교)

  • Jang, Hye-Ja;Kim, Hye-Ok;Un, Hyeon-Seon;Jo, Bok-Hui
    • Journal of Gifted/Talented Education
    • /
    • v.10 no.2
    • /
    • pp.25-46
    • /
    • 2000
  • These purposes are to have a necessity to be educated for the linguistic gifted among many gifted in speedy changeable age, and to find out what differences are of properties between the linguistic gifted children and nongifted children through comparing/analysing to gifted children any nongifted children using performance evaluation on writer's ability. Therefore, it intends to use as a assisting material in order to develop ability and properties of the linguistic gifted children and nongifted children as well. The studying details are 1) to compare/analyze thinking ability between the linguistic gifted children and nongifted children 2) to find out differences of thinking ability for unrealistic reasoning between the linguistic gifted children and nongifted children. The studying subjects had been chosen 3 children as a first grade in 'C' Gifted Academy and 3 children as a first grade in an elementary school from June 3, 1999 to June 12, 1999. The studying instrument was an evaluation of linguistic properties certification(Project Spectrum : Krechevsky,'1994). It had got a frequency calculation, average and standard deviation through the material anylzing with the program SPSSWIN. The conclusions are as belows, First, as a result of performance evaluation on writer's ability to gifted children and nongifted children, the gifted children were outstandingly shown the linguistic ability getting much higher score than nongifted children in respect of vocabulary level, structure of writing, and consistency/logicality of theme. Second, it was shown the gifted children had diffusing thought than nongifted children through the esthetic question and impformation memories with listening to the realistic juvenil story and the unrealistic juvenile story.

  • PDF

Review on factors affecting the optical properties of dental zirconia (치과용 지르코니아의 광학적 성질에 영향을 미치는 요소에 대한 문헌고찰)

  • Park, Chan-Ho;Ko, Kyung-Ho;Park, Chan-Jin;Cho, Lee-Ra;Huh, Yoon-Hyuk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.177-185
    • /
    • 2021
  • Clinical applications of translucent zirconia as well as traditional zirconia (3 mol% yttria stabilized tetragonal zirconia polycrystal, 3Y-TZP) are increasing. For this reason, studies on factors affecting the optical properties of dental zirconia have been continuously reported. The optical effect of dental zirconia may vary depending on the yttria content, the thickness of the prosthesis, the sintering process, polishing, glazing and cementation in laboratory and clinical procedures. Increasing the yttria concentration can reduce the masking effect. Translucency decreases as the thickness of the restoration increases, but the required thickness may vary depending on the properties of the zirconia block. The high-speed sintering method can shorten the manufacturing time, but in some cases, the translucency of the prosthesis may decrease. In addition, the optical properties can be affected by the surface roughness of zirconia and the polishing process. The use of an appropriate colored cement can help with the masking effect of zirconia and can be useful for color matching for more esthetic results.

Superimposition: a simple method to minimize occlusal adjustment of monolithic restoration (디지털 장비의 중첩기능을 이용하여 단일체 수복물의 교합조정을 최소화한 증례)

  • Choi, Changhun;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.253-258
    • /
    • 2016
  • The development of translucent zirconia enabled clinicians to choose a monolithic zirconia crown as one treatment modality in the posterior dentition. Careful occlusal adjustments are recommended for monolithic zirconia crowns because grinding zirconia inevitably causes phase transformation, which may deteriorate mechanical properties. intraoral scanners enable the clinician to scan and superimpose a complete tooth structure before preparation onto the prepared abutment. This technique helps to reproduce the original tooth form and occlusion of the patient. In this case report, prostheses were fabricated for patients with cracked or fractured tooth by applying intraoral scanner, Computer aided design-computer aided manufacturing (CAD-CAM) and monolithic zirconia crown to reproduce the occlusion of original tooth and to minimize occlusal adjustment. The clinical results were satisfactory in both esthetic and functional aspects.

Spectrophotometric analysis of feldspathic porcelain with silver ion (은이온을 첨가한 장석계 도재의 분광 측색학적 평가)

  • Kim, Jihyun;Song, Kyeongwoo;Noh, Sera;Yun, Kyelim;Yun, Kwidug
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.1
    • /
    • pp.20-25
    • /
    • 2015
  • Purpose: This study was evaluated the shade of feldspathic porcelain with various concentration of silver ion. Materials and Methods: The control group was conventional feldspathic porcelain with no silver ion, the experimental groups were the feldpathic porcelain with 5%, 10%, 20%, 30% silver ion. The number of specimens on the each group was 5. Commission Internationale de I'Eclairage (CIE) $L^*a^*b^*$ parameters were recorded twice for each specimen with a spectrophotometer (Model CM-2600d, Minolta, Japan). One-way Anova was used for statistical analysis. Results: L value was similar. a value was increasing and b value was decreasing with silver ion statistically significantly. ${\Delta}E$ was increasing according to silver ion significantly. Conclusion: The shade of feldspahtic porcelain was influenced by silver ion. Ag ion under 10% concentration is acceptable clinically.

THE PHYSICAL PROPERTIES OF REUSED IPS EMPRESS CERAMIC PART IV : HARDNESS AND FRACTURE TOUGHNESS (반복 사용된 IPS Empress ceramic의 물리적 성질에 관한 연구 Part IV : 경도 및 파괴인성에 관한 연구)

  • Jin Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.532-537
    • /
    • 2003
  • Statement of the problem : IPS Empress ceramic has been used as one of a esthetic restorative material since it's development, but the broad application of IPS Empress ceramic to clinical prosthodontic field has been limited by its high material cost. Purpose : This study was investigated to evaluate the hardness and fracture toughness after recycling of the IPS Empress ceramic. Material and methods : Reused specimens of IPS Empress were fabricated with repeated pressing. The hardness(Vickers hardness) and fracture toughness of 1st, 2nd and 3rd pressed specimens were measured with Digital Micro Hardness Tester(Model MXT70, Matsuzawa Seiki Co., Ltd, Tokyo, Japan). The obtained data were analyzed using SPSS(Ver 9.5). Result : The mean value of the hardness in the 1st, 2nd and 3rd pressed Empress were $6.23{\pm}0.48MPa,\;5.50{\pm}0.25MPa$, and $5.70{\pm}0.42MPa$. The hardness of the 1st pressing ceramic was higher than those or the 2nd and 3rd pressed ceramics(P<0.05). Hardness of the 3rd pressed ceramic was greater than that of the 2nd pressed ceramic. but there was no significant difference of hardness between those two(P>0.05). The mean value of the fracture toughness was $1.71{\pm}0.16MPam^{1/2}$ in 1st pressed ceramic, $1.78{\pm}0.10MPam^{1/2}$ in 2nd pressed and $1.73{\pm}0.14MPam^{1/2}$ in 3rd pressed IPS ceramic. Fracture toughness of the 2nd pressed ceramic was the highest and that of the 1st pressed ceramic was the lowest. There was no significant difference of fracture toughness among them(P>0.05). Conclusion : Hardness of the 2nd and 3rd pressed IPS Empress ceramics were lesser than that of 1st pressed IPS Empress ceramic(P<0.05), but there was no significant changes of fracture toughness among them(P>0.05).

Study on Convergence Technique through Flow Analysis at the Flexible Joint of the Pipe Laying (배관의 신축이음에서의 유동해석을 통한 융합기술연구)

  • Lee, Jung-Ho;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.3
    • /
    • pp.13-18
    • /
    • 2015
  • This paper is the study on the safe design of joint controling the pressure and temperature by connecting between pipes laying with the flexible joint. This study aims at decreasing the excessive pressure applied in the pipe and preventing the accident occurrence in order to solve the pipe damage by extraction and contraction due to the pressure of open air and transport gas. The flow properties of each model are investigated through the simulation analysis by applying three kinds of the flexible joints. When transport gas passes the flexible joint, the flow characteristics of heat, pressure and velocity at pipe laying are analyzed. It is thought to be contributed to the safe design due to the shape of the flexible joint by using the result of this study. And it is possible to be grafted onto the convergence technique at design and show the esthetic sense.

Characteristics of BGsome-Coated Illite as a Face Powder (BGsome이 코팅된 일라이트 및 이를 함유한 페이스 파우더의 특성)

  • Lim, Jin Kyong;Jin, Byung Suk
    • Applied Chemistry for Engineering
    • /
    • v.24 no.2
    • /
    • pp.126-131
    • /
    • 2013
  • BGsome coating on the surface of illite powder was attempted to impart skin affinity and improve various characteristics of the powder for makeup cosmetics. BGsome is a type of hydrated liquid crystalline vesicles prepared by the hydration of 1,3-butylene glycol (BG) dissolved lecithin. BGsome droplets were coated through wet process and the coated powders were analyzed by TGA, SEM, and particle size measurements. Effect of BGsome coating on the physical properties, such as flow-ability, dispersibility, spreadability, and adhesion, were examined. The repose angle of BGsome-coated illite was decreased, which means that BGsome coating improves the flowability of the powder. Dispersibility, spreadability, and adhesion of the coated illite were also improved remarkably. The result of adhesion tests showed that the BGsome-coated illite was evenly adhered onto artificial leather surface with almost no lumps. The flowability, dispersibility, spreadability and adhesion of face powders containing the BGsome-coated illite were also improved.