• Title/Summary/Keyword: error range

Search Result 2,811, Processing Time 0.028 seconds

A Study on the Reliability Verification of Availability Simulation for Complex Plant (플랜트 가용도 평가 시뮬레이터의 신뢰성 검증에 관한 연구)

  • Lee, Hongcheol;Hwang, Inju;Lee, Hyundong
    • Korean Journal of Computational Design and Engineering
    • /
    • v.20 no.1
    • /
    • pp.36-43
    • /
    • 2015
  • Recently, a number of evaluation studies on availability of plant were carried out. This study was conducted to verify of the reliability of a simulation with some variable such as configuration of process, failure probability density function and the number of iteration times for the natural gas liquefaction plant. The error rate of the KICT-RAM solution was evaluated as 0.03~1.79% compared with the result of the MAROS(commercial solution). And the error-rate change was observed in the range of 0.03~1.75 on the condition of the iteration times as 30, 100, 250. As a result the plant availability evaluation approach of KICT-RAM solution was verified as reasonable. However, the careful approach was required to use the solution because the error-rate increased according to iteration times change.

Plasma Initiation in the KAERIT Tokamak (KAERIT 토카막의 플라즈마 생성 실험)

  • In, Sang-Ryul;Bak, Hae-Ill
    • Nuclear Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.246-252
    • /
    • 1988
  • Experiments on the hydrogen gas breakdown for plasma initiation in the KAERIT tokamak are described. The influence of the applied loop voltage, toroidal magnetic field, gas filling pressure, error magnetic field, and preionization is studied. It is concluded that the magnitude of the error field is the most important factor for successful discharge initiation. The gas breakdown voltage becomes minumum when the external compensating field most effectively corrects the net error field. Even though preionization effect is not prominent, it is exhibited more easily in the case of worse confinement. Discharge initiation conditions experimentally determined are compared with those calcuated from a theoretical model. Some other unknown physical processes maintain the operation range somewhat narrower than predicted by the present theoretical model. However, this model is adequate for the breakdown phase of tokamaks.

  • PDF

An Adaptive Utterance Verification Framework Using Minimum Verification Error Training

  • Shin, Sung-Hwan;Jung, Ho-Young;Juang, Biing-Hwang
    • ETRI Journal
    • /
    • v.33 no.3
    • /
    • pp.423-433
    • /
    • 2011
  • This paper introduces an adaptive and integrated utterance verification (UV) framework using minimum verification error (MVE) training as a new set of solutions suitable for real applications. UV is traditionally considered an add-on procedure to automatic speech recognition (ASR) and thus treated separately from the ASR system model design. This traditional two-stage approach often fails to cope with a wide range of variations, such as a new speaker or a new environment which is not matched with the original speaker population or the original acoustic environment that the ASR system is trained on. In this paper, we propose an integrated solution to enhance the overall UV system performance in such real applications. The integration is accomplished by adapting and merging the target model for UV with the acoustic model for ASR based on the common MVE principle at each iteration in the recognition stage. The proposed iterative procedure for UV model adaptation also involves revision of the data segmentation and the decoded hypotheses. Under this new framework, remarkable enhancement in not only recognition performance, but also verification performance has been obtained.

Power Transmission from a Vibrating Mass to a Supporting Elate through Isolators (능동 및 수동격리기를 적용한 진동계에 있어서 힘의 전달에 관한 연구)

  • Jin-Woo Lee;Colin H. Hansen
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.200-207
    • /
    • 2001
  • The transmission of harmonic vibratory power form a vibrating rigid body into a supporting plate through passive and active isolators is investigated theoretically and experimentally. The theoretical model allows for the transmission of vertical and horizontal harmonic forces and moments about all three coordinate sun. The experiment is to use vibration actuators attached to the intermediate mass of the two-stage mount to minimize the rotational and translational vibration of the intermediate mass. The performance is done by measuring the vibration at the error sensors due to the primary vibration source and measuring the transfer functions from the control sources to the error sensors. Results show that over a frequence range from 1 to 100Hz, transmission into the supporting plate can be reduced substantially by employing in parallel with existing passive isolators, active isolators adjusted to provide appropriate control force amplitudes.

  • PDF

A Systematic Method of Probing Channel Characteristics of Home Power Line Communication Network for IP Based Control of Home Appliances (IP기반 가전 제어를 위한 전력선 통신망 채널 특성 추정기법에 관한 연구)

  • Ahn, Nam-Ho;Kim, Jung-Keun;Lee, Jae-Sik;Chang, Tae-Gyu;Kim, Hoon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.12
    • /
    • pp.696-701
    • /
    • 2003
  • This paper presents a systematic method of probing channel characteristics and communication reliabilities of home power line communication network applied to the Internet accessed control of home appliances. The effects of the three performance deterioating factors, i.e., additive noise, channel attenuation, and intersymbol interference, can be systematically measured by applying the channel probing waveform in the frequency range from 100KHz to 450KHz. Probability of bit error is derived with the probed channel parameters of the signal attenuation, noise and signal-to-interference ratio read in the frequency domain. The agreement between the derived probability of bit error and the measured probability of bit error supports the validity of the proposed approach of probing home power line channel characteristics. The experimental results performed with the constructed test-bed applying the proposed channel probing method also support the feasibility of commercially deploying the PLC modem installed home appliances and their services for the Internet accessed home automation.

Sensorless Control of Non-salient PMSM using Rotor Position Tracking PI Controller (회전자 위치 추정 PI 제어기를 이용한 비돌극형 PMSM 센서리스 제어)

  • Lee Jong-Kun;Seok Jul-Ki;Lee Dong-Choon;Kim Heung-Geun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.11
    • /
    • pp.664-670
    • /
    • 2004
  • This paper presents a new velocity estimation strategy of a non-salient permanent magnet synchronous motor (PMSM) drive without high frequency signal injection or special PWM pattern. This approach is based on the d-axis current regulator output voltage of the drive system that has the information of rotor position error. The rotor velocity can be estimated through a rotor position tracking PI controller that controls the position error to zero. For zero and low speed operation, PI controller gains of rotor position tracking controller have a variable structure according to the estimated rotor velocity. In order to boost the bandwidth of PI controller around zero speed, a loop recovery technique is applied to the control system. The proposed method only requires the flux linkage of permanent magnet and is insensitive to the parameter estimation error and variation. The designers can easily determine the possible operating range with a desired bandwidth and perform the vector control even at low speeds. The experimental results show the satisfactory operation of the proposed sensorless algorithm under rated load conditions.

CRA Based Robust Controller Design for PWM Converter (CRA 기법을 이용한 PWM 컨버터의 강인제어기 설계)

  • Kim, Soo-Cheol;Kim, Hyung-Chul;Chung, Gyo-Bum;Choi, Jae-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.183-190
    • /
    • 2007
  • In this paper, a robust controller for PWM converter is proposed. The proposde converter controller consists of a PI controller for DC output voltage and a current controller using error-space approach for maintaining the sinusoidal current waveform and unity power factor. Conventionally, the try and error method has been used to design the current controller considering the switching frequency of the devices and sampling frequency of the digital controller. But this proposed method is based on characteristic ratio assignment(CRA) method which has the advantage to design the optimal gain to meet the referenced response and overshoot within the limit range. First, the CRA based current controller algorithm is explained. Then the validity of proposed controller is verified through the PSiM simulation and experience results.

The Propose of Optimal Flow Data Acquisition by Error Rate Analysis of Flow Data (유량 데이터 오차율 분석을 통한 최적의 유량데이터 취득방안 제안)

  • Kim, Yunha;Choi, Hyunju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.3
    • /
    • pp.249-256
    • /
    • 2017
  • Recently, application areas based on M2M (Machine-to-Machine communications) and IoT (Internet of Things) technologies are expanding rapidly. Accordingly, water flow and water quality management improvements are being pursued by applying this technology to water and sewage facilities. Especially, water management will collect and store accurate data based on various ICT technologies, and then will expand its service range to remote meter-reading service using smart metering system. For this, the error in flow rate data transmitting should be minimized to obtain credibility on related additional service system such as real time water flow rate analysis and billing. In this study, we have identified the structural problems in transmitting process and protocol to minimize errors in flow rate data transmission and its handling process which is essential to water supply pipeline management. The result confirmed that data acquisition via communication system is better than via analogue current values and pulse, and for communication method case, applying the industrial standard protocol is better for minimizing errors during data acquisition versus applying user assigned method.

FPGA Implementation of Reed-Solomon Encoder for image transmission (영상 전송을 위한 Reed-Solomon Encoder의 FPGA 구현)

  • Kim, Dong-Nyeon;Cai, Yu Qing;Byon, Kun-sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.907-910
    • /
    • 2009
  • This paper is the FPGA Implementation of Reed-Solomon Encoder that is one of Error control Codes. Reed-Solomon codes are block-based error control codes with a wide range of applications in digital communications. RS codes are strong on burst errors because it process signals as symbol. We simulate this system using Matlab from Mathworks and design it using System Generator from Xilinx. We refer Matlab source in Implementation of Reed-Solomon Error Control Coding for Compressed Images by Simon Anthony Raspa.

  • PDF

New mathematical approach to determine solar radiation for the southwestern coastline of Pakistan

  • Atteeq Razzak;Zaheer Uddin;M. Jawed Iqbal
    • Advances in Energy Research
    • /
    • v.8 no.2
    • /
    • pp.111-123
    • /
    • 2022
  • Solar Energy is the energy of solar radiation carried by them in the form of heat and light. It can be converted into electricity. Solar potential depends on the site's atmosphere; the solar energy distribution depends on many factors, e.g., turbidity, cloud types, pollution levels, solar altitude, etc. We estimated solar radiation with the help of the Ashrae clear-sky model for three locations in Pakistan, namely Pasni, Gwadar, and Jiwani. As these locations are close to each other as compared to the distance between the sun and earth, therefore a slight change of latitude and longitude does not make any difference in the calculation of direct beam solar radiation (BSR), diffuse solar radiation (DSR), and global solar radiation (GSR). A modified formula for declination angle is also developed and presented. We also created two different models for Ashrae constants. The values of these constants are compared with the standard Ashrae Model. A good agreement is observed when we used these constants to calculate BSR, DSR, GSR, the Root mean square error (RMSE), Mean Absolute error (MABE), Mean Absolute percent error (MAPE), and chisquare (χ2) values are in acceptance range, indicating the validity of the models.