• Title/Summary/Keyword: error range

Search Result 2,816, Processing Time 0.035 seconds

Reference Trajectory Generation of Flight Tests Using an Aircraft through Post-Processing of GPS Receiver Data (GPS 수신기 데이터의 후처리를 통한 항공기 비행시험 기준궤적 생성)

  • Moon, Ji-Hyeon;Kwon, Byung-Moon;Shin, Yong-Sul;Choi, Hyung-Don
    • Aerospace Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.60-66
    • /
    • 2010
  • This paper deals with a post-processing of GPS receiver data in order to acquire a reference flight trajectory of an aircraft test. The flight test using an aircraft that is carried out several times since 2007 is the integrated test to verify the performance of the tracking and communications facilities in Naro Space Center and Jeju Tracking Center. In order to analyze performance of the tracking and navigation equipments, true reference data should be used for performance comparisons. Therefore off-the-shelf commercial GPS receiver, DL-V3 made by NovAtel Inc., is operated on the test to collect the GPS navigation data and the collected data is post-processed by GrafNav which is the off-the-shelf post-processing program made by NovAtel Inc. Through the post-processing of the collected data, a reference trajectory is generated with small error range about several decade centimeter level.

X-Ray Fluorescence Analysis of $Ta_2O_5,\;Nb_2O_5$ and ZrO_2$ in Tin-Slag Samples using Simple Dilution Method (주석 슬랙중 $Ta_2O_5,\;Nb_2O_5$ZrO_2$의 단일희석법을 이용한 X-선 형광분석)

  • Young-Sang Kim;Hak Je Sung
    • Journal of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.293-301
    • /
    • 1984
  • -ray fluorescence analysis of $Ta_2O_5$, $Nb_2O_5$ and $ZrO_2$ in tin-slag samples using the simple dilution method was studied. The method is to correct mathematically the calibration curve to the linear line by the dilution. One synthesized standard having similar composition to the sample and tin slag samples were diluted with anhydrous $Li_2B_4O_7$ at the level of 1%, 2% and 3% of the sample content respectively. The diluted samples were fused at $1150^{\circ}C$ for 30 minutes and these glass beads were finely ground and pelletized. Measuring the X-ray intensities with these pellets, analytical results were calculated by the equation derived from J. Scherman's equation for the characteristic X-ray intensity of an element. Analytical results agreed with the reference values obtained by the standard calibration method within allowable error range and were reproducible.

  • PDF

X-Ray Spectrometric Determination of $Ta_2O_5,\;Nb_2O_5$ and $ZrO_2$in Tin-Slag Samples by Double Dilution Technique (주석-슬랙중 $Ta_2O_5,\;Nb_2O_5$$ZrO_2$의 이중희석법을 이용한 X-선 분광분석)

  • Young-Sang Kim;Kee-Chae Park
    • Journal of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.302-308
    • /
    • 1984
  • X-ray spectrometric determination of $Ta_2O_54, $Nb_2O_5$ and $ZrO_2$ in tin-slag samples using the double dilution technique was conducted. Tin-slag samples and one synthesized standard sample having similar composition to the samples were diluted with anhydrous $Li_2B_4O_7$ at the level of 1.00, 2.00 and 3.00% of the sample content, respectively. The diluted samples were fused at $1,150^{\circ}C$ for 30 minutes, and these glass beads were finely ground and pelletized. With the X-ray intensities measured, analytical results were calculated by the double dilution equation. The results agreed to the reference values obtained by the standard calibration method and the simple dilution technique within allowable error range and were reproducible.

  • PDF

Studies on the Elution Behavior and the Simultaneous Analysis of Some Metal-Dithiocarbamate Chelates by Reversed-Phase High Performance Liquid Chromatography (역상 액체 크로마토그래피에 의한 몇가지 금속-Dithiocarbamate 킬레이트의 용리거동 및 동시분석에 관한 연구)

  • Dai Woon Lee;Yun Je Kim;Hyun Chul Kim;Won Lee
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.3
    • /
    • pp.211-226
    • /
    • 1988
  • Liquid chromatographic behavior of several metal ions in dithiocarbamate(DTC) chelates were investigated by reversed phase high performance liquid chromatography on Novapak $C_{18}$ and ${\mu}$-Bondapak $C_{18}$ columns. The optimum conditions for the separation of DTC-metal chelate were examined with respect to the pH, shaking time, flow rate, extraction solvent, and mobile phase strength. The metal ions in mixtures at trace level, chelated with some dithiocarbamate derivatives were separated successfully on Novapak $C_{18}$ column using acetonitrile/methanol/water or acetonitril/water mixtures as mobile phases. It was found that all DTC metal chelates studied were eluted in an acceptable range of capacity factor values ($0{\leqq}log\;k'{\leqq}1$). Although several foreign metal ions were coexisted, high recovery and good precision were attained ; 97.0-106.7 % for the recovery and 0.98-3.41% for the coefficient of variation. Under the optimum analytical conditions, trace metal ions in the composite water samples were determined sucessfully with in relative error of about {\pm}$6.7 %.

  • PDF

A Two-Phase Pressure Drop Calculation Code Based on A New Method with a Correction Factor Obtained from an Assessment of Existing Correlations (기존 상관관계식들의 평가를 통해 얻은 수정계수를 사용하는 새로운 방법에 기초한 2상류 압력강하 계산코드)

  • Chun, Moon-Hyun;Oh, Jae-Guen
    • Nuclear Engineering and Technology
    • /
    • v.21 no.2
    • /
    • pp.73-88
    • /
    • 1989
  • Ten methods of the total two-phase pressure drop prediction based on five existing models and correlations have been examined for their accuracy and applicability to pressurized water reactor conditions. These methods were tested against 209 experimental data of local and bulk boiling conditions : Each correlations were evaluated for different ranges of pressure, mass velocity and Quality, and best performing models were identified for each data subsets. A computer code entitled 'K-TWOPD' has been developed to calculate the total two-phase pressure drop using the best performing existing correlations for a specific property range and a correction factor to compensate for the predicted error of the selected correlations. Assessment of this code shows that the present method fits all the available data within $\pm$11% at a 95% confidence level compared with $\pm$25%, for the existing correlations.

  • PDF

Tolerance analysis of Multi-Configurative Microscopic System for Inspecting the Wire-Bonding Status of Semiconductor Chips (반도체 와이어 본딩 검사용 다중배치 현미경 광학계에 대한 공차분석)

  • Ryu, Jae-Myung;Kim, Jae-Bum;Kang, Geon-Mo;Jung, Jin-Ho;Baek, Seung-Sun;Jo, Jae-Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.2
    • /
    • pp.149-158
    • /
    • 2006
  • We have analyzed various tolerances of the multi-configurative microscopic system for inspecting the wire-bonding of a reed frame by using the Gaussian bracket method and the equivalent lens method. The tolerances for the curvature and the thickness, which are axial symmetric tolerances, are given by varying the back focal length within a fecal depth under diffraction-limited conditions. Moreover, by using the trial and error method, the axial non-symmetric tolerances for decenter and tilt are established by assigning the 5% variation of MTF(modulation transfer function) at the spatial frequency of 50 lp/mm and at the field angle of 0.7 field. As the tolerances with the most probable distribution are distributed within the range of the decay rate of less than 5% independent of the probability distribution of tolerances, we can achieve completely the desired design performances of the multi-configurative microscopic system by using the various ranges of these tolerances.

Method for Analysis of C3 System of Systems Using Transformation of Federation Based on an Extended DEVS Formalism (확장된 DEVS 형식론 기반 페더레이션의 변환을 통한 C3 복합 체계의 분석 방법)

  • Kang, Bong Gu;Kim, Tag Gon
    • Journal of the Korea Society for Simulation
    • /
    • v.27 no.3
    • /
    • pp.13-21
    • /
    • 2018
  • The system of systems (SoS) based analysis method for the C3 system consisting of the communication system and the command and control (C2) system has the advantage that detailed analysis is possible, but it requires long execution time per one trial, which makes the analysis of various scenarios difficult. To solve this problem, this paper proposes a method for analysis of C3 SoS using a transformation of a federation into an integrated simulation. This transformation technique reduces the execution time while maintaining accuracy by abstracting the system other than the one to be analyzed, consisting of model hypothesis and function identification. The former can construct an abstracted model for the simulation through the proposed extended Discrete Event Systems Specification (DEVS) formalism and the latter can express the characteristics of the model influenced by other systems. From the case study on C and C2 analysis, the experimental results show that this method shortened the time considerably while maintaining the accuracy within an acceptable error range and we expect that this method will enable the exploratory analysis of the complex systems other than C3.

Tape-Type Liquid Leakage Film Sensor (액체누설 감지용 테이프형 필름센서)

  • Yu, D.K.;Kim, K.S.;Yub, H.K.;Han, G.H.;Jin, D.J.;Kim, J.H.;Han, S.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.2
    • /
    • pp.146-154
    • /
    • 2011
  • The adhesive-tape of a liquid leak film sensor including the alarm system is developed. The sensing film is composed of three layers such as base film layer, conductive line layer, and protection film layer. The thickness of film is 300~500 um, the width is 3.55 cm, and the unit length is 200 m. On the conductive line layer, three conducting lines and one resistive line are formulated by the electronic printing method with a conducting ink of silver-nano size. When a liquid leaks for the electricity to be conducted between the conductive line and the resistive line, the position of leakage is monitored by measuring the voltage varied according to the change of resistance between two lines. The error range of sensing position of 200 m film sensor is ${\pm}1m$.

Heat Transfer between Substrate and Substrate-heater in Low Vacuum (저진공 내 시료가열판과 시료의 열전달)

  • Park, Hyon-Jae;Oh, Soo-Ghee;Shin, Yong-Hyeon;Chung, Kwang-Hwa
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.302-310
    • /
    • 2008
  • Heat transfer between substrate and substrate-heater in low vacuum was investigated. The convection related with gas flow and pressure, the heat conduction considering surface roughness and contact pressure, and the heat loss by radiation depending on the surface emissivity were considered. The coefficient of heat conduction $h_c$ in the Fourier's law were determined experimentally from the temperature difference between the substrate and the substrate-heater in the range of substrate-heater temperature $100\;-\;500^{\circ}C$, in the pressures of 300 mTorr - 1 Torr. The temperature difference was then calculated in the reverse way for the purpose of verification, using the heat flow and the experimentally determined coefficients. The verified temperature differences were thus obtained within 0.33 % error.

Construction of the Airborne Gravity Based Geoid and its Evaluation (항공중력기반 지오이드 모델 구축 및 검증)

  • Lee, Ji-Sun;Kwon, Jay-Hyoun;Lee, Bo-Mi;Hong, Chang-Ki
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.2
    • /
    • pp.159-167
    • /
    • 2009
  • To obtain the gravity data with consistent quality and good distribution over Korea, to overcome the difficulties in constructing precision geoid from biased distribution of ground data, to resolve the discrepancy between the ground and ocean gravity data, an airborne gravity survey was conducted from Dec. 2008 to Jan. 2009. The data was measured at the average flying height of 3,000m and the data with cross-over error of 2.21mGal is obtained. The geoid constructed using this airborne gravity data shows the range of 9.34 $\sim$ 33.88m. Comparing the geoid with respect to the GPS/levelling data, a precision of 0.145m is obtained. After fitting, the degree of fit to GPS/levelling data was calculated about 5cm. It was found that there exists large biases in the area of south-western and northern part of the peninsular which is considered to be the effect of distorted vertical datum in Korea. Thus, more investigation on vertical datum would be needed in near future.