• Title/Summary/Keyword: error generator

Search Result 359, Processing Time 0.024 seconds

Design of Software GPS L2 Civil Signal Generator (ICCAS 2003)

  • Seo, Sam-Suk;Cho, Deuk-Jae;Lee, Sang-Jeong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2632-2635
    • /
    • 2003
  • This paper designs a software signal generator for the new GPS L2 civil signal. The CM/CL code and the message structure of L2CS described in GPS ICD PPIRN-200C-007 are used in designing the signal generator. The output of the GPS signal generator is designed as the sampled IF data with the sampling frequency 5.7MHz and stored in the binary data format. By analyzing both the spectrum characteristics of the output signal and the correlation properties of the CM/CL code, the validation of the designed GPS signal generator is shown. It should be mentioned that the modeling of the GPS satellite constellation and the error sources remains for implementing the software space segment of GPS.

  • PDF

System Analysis of a Gas Generator Cycle Rocket Engine

  • Cho, Won Kook;Kim, Chun IL
    • International Journal of Aerospace System Engineering
    • /
    • v.6 no.2
    • /
    • pp.11-16
    • /
    • 2019
  • A system analysis program has been developed for a gas generator cycle liquid rocket engine of 30 ton class. Numerical models have been proposed for a combustor, a turbopump, a gas generator and pressure drop through a regenerative cooling system. Numerical algorithm has been validated by comparing with the published data of MC-1. The major source of error is not the numerical algorithm but the imperfect performance models of subsystems. So the precision of the program can be improved by revising the performance models using experimental data. The sea level specific impulse and vacuum specific impulse have been demonstrated for a 30 ton class gas generator engine. The optimal condition of combustor pressure and mixture ratio for specific impulse which is a typical characteristic of a gas generator cycle engine has been illustrated.

A Study on the Improvement of the Arithmetic for Emergency Generator Capacity (비상발전기용량 산정식 개선에 관한 연구)

  • Lee, Jong-Hyuk;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1517-1522
    • /
    • 2018
  • This paper describes the improvement of the arithmetic for emergency generator capacity. This formula which calculates emergency generator is dependent on the Korean Design Standard of building electrical equipment issued by the Ministry of Land, Infrastructure and Transport, and the technical data related to the generator. when appling the formula, the capacity of the generator is insufficient at the starting conditions of the load facility. In case of emergency, the generator is not operated normally. $PG_2$ of the formula ($PG_1$, $PG_2$, $PG_3$) applied in determining the capacity of the emergency generator is selected by calculating the capacity of the generator based on only biggest one motor among the load equipment and $PG_3$ may not be able to start the generator normally in case of emergency because there is an error such that the power factor is applied at the last start of the motor having the maximum capacity of the load. We analyze the problem of capacity calculation of emergency generators used for general purposes. As a consequence, the improved formulas have been presented for safety of electrical installation.

Analysis for the Operating Characteristics when the Induction Motor is Used as a Generator (유도전동기를 발전기로 사용시 동작 특성 해석)

  • Kim, Jong-Gyeum
    • New & Renewable Energy
    • /
    • v.10 no.2
    • /
    • pp.5-11
    • /
    • 2014
  • Squirrel cage induction motor is the main driving system of industrial field and familiar with its use in a large variety of applications. The structure and operating characteristics of induction generator is almost identical to induction motor, but the induction generator part is used restrictively from hydropower power and wind power development etc. Recently induction generator is commonly used for micro & small hydro power applications due to its simplicity, reliability, low cost and robustness. Input and output of induction motor has turned against at the induction generator operation. Rotation speed of induction generator is small faster than synchronous speed of induction motor. As output of induction machines increases with the increasement of speed, so loss is same. Actually, generator efficiency is lower than motor at this condition. If induction generator is connected with mechanical load such as increaser, total efficiency is decreased. Consequently the quality in compliance with an induction motor parameter applying like that in the generator is a possibility of having the error of some. In this paper, we analyzed that input, output, torque and efficiency of induction machine is different from each other above and below synchronous speed.

On the Optimum Linear Voltage Regulator of a Self-excited DC Shunt Generator (직류자여자분권발전기의 최적선형전압조정기에 관한 연구)

  • Jong Swoo Won
    • 전기의세계
    • /
    • v.22 no.4
    • /
    • pp.11-16
    • /
    • 1973
  • This paper presents an optimum control of the field resistance for the self-excited DC shunt generator to keep a constant terminal voltage in case of the load change or the torque variation in the system. The non-linearity of the system is linearized by applying the small signal technique and the linearized equation is solved by the maximum principle with the digital computer. The optimal control value of the field resistance for the step error of the generator output voltage is obtained and the transient voltage characteristics in the system are investigated.

  • PDF

The Improvement Output of the Synchronous Generator Excitor using CRA control method (CRA 제어기법을 이용한 동기발전기 여자기의 출력 개선)

  • Hong, Hyun-Mun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.449-450
    • /
    • 2008
  • It is difficult to find for analysis solution of the synchronous generator exciter system. Recently, it had good performence UPS converter system using CRA method. The single converter of synchronous generator excitor system under considerations : (i) the overall system shall keep very low AC-voltage tracking error as well as no phase delay over different load condition, and (ii) the digital controller shall be employed at a fixed sampling. It is shown that the synchronous exciter system can be achieved by the proposed controller using Characteristic Ratio Assignment.

  • PDF

Design Circuit Parameter Estimation of Impulse Generator and its application to 10/350${\mu}s$ Lightning Impulse Current Generator (임펄스 발생기의 회로 설계 파라미터 예측계산과 10/350${\mu}s$ 뇌임펄스 전류발생기 적용)

  • Lee, Jae-Bok;Shenderey, S. V.;Chang, Sug-Hun;Myung, Sung-Ho;Cho, Yuen-Gue
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1822-1828
    • /
    • 2008
  • This paper presents design parameter calculation methodology and its realization to construction for the 10/350${\mu}s$ lightning impulse current generator(ICG) modelled as double exponential function waveform with characteristic parameters ${\alpha},{\beta}$. Matlab internal function, "fzero" was applied to find ${\lambda}={\alpha}/{\beta}$ which is solution of nonlinear equation linearly related with two wave parameter $T_1$ and $T_2$. The calculation results for 10/350${\mu}s$ lightning impulse current show very good accuracy with error less 0.03%. Two type of 10/350${\mu}s$ ICGs based on the calculated design circuit parameters were fabricated by considering the load variation. One is applicable to the MOV based Surge protective device(SPD) for less 15 kA and the other is to test small resistive devices such as spark gap arrester and bonding device with maximum current capability 30 kA. The tested waveforms show error within 10% in comparison with the designed estimation and the waveform tolerance recommended in the IEC 61643-1 and IEC 60060-1.

Magnetic Flux Leakage (MFL) based Defect Characterization of Steam Generator Tubes using Artificial Neural Networks

  • Daniel, Jackson;Abudhahir, A.;Paulin, J. Janet
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.34-42
    • /
    • 2017
  • Material defects in the Steam Generator Tubes (SGT) of sodium cooled fast breeder reactor (PFBR) can lead to leakage of water into sodium. The water and sodium reaction will lead to major accidents. Therefore, the examination of steam generator tubes for the early detection of defects is an important requirement for safety and economic considerations. In this work, the Magnetic Flux Leakage (MFL) based Non Destructive Testing (NDT) technique is used to perform the defect detection process. The rectangular notch defects on the outer surface of steam generator tubes are modeled using COMSOL multiphysics 4.3a software. The obtained MFL images are de-noised to improve the integrity of flaw related information. Grey Level Co-occurrence Matrix (GLCM) features are extracted from MFL images and taken as input parameter to train the neural network. A comparative study on characterization have been carried out using feed-forward back propagation (FFBP) and cascade-forward back propagation (CFBP) algorithms. The results of both algorithms are evaluated with Mean Square Error (MSE) as a prediction performance measure. The average percentage error for length, depth and width are also computed. The result shows that the feed-forward back propagation network model performs better in characterizing the defects.

Design of digital nuclear power small reactor once-through steam generator control system

  • Qian, Hong;Zou, Mingyao
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2435-2443
    • /
    • 2022
  • The once-through steam generator used in the small modular reactor needs to consider the stability of the outlet steam pressure and steam superheat of the secondary circuit to achieve better operating efficiency. For this reason, this paper designs a controllable operation scheme for the steam pressure and superheat of the small reactor once-through steam generator. On this basis, designs a variable universe fuzzy controller, first, design the fuzzy control rules to make the controller adjust the PI controller parameters according to the change of the error; secondly, use the domain adjustment factor to further subdivide the input and output domain of the fuzzy controller according to the change of the error, to improve the system control performance. The simulation results show that the operation scheme proposed in this paper have better system performance than the original scheme of the small reactor system, and controller proposed in this paper have better control performance than traditional PI controller and fuzzy PI controller, what's more, the designed control system also showed better anti-disturbance performance in lifting experiment between 100% and 80% working conditions. Finally, the experimental platform formed by connecting the digital small reactor with Matlab/Simulink through OPC(OLE for Process Control) communication technology also verified the feasibility of the proposed scheme.

Data Randomization Scheme for Endurance Enhancement and Interference Mitigation of Multilevel Flash Memory Devices

  • Cha, Jaewon;Kang, Sungho
    • ETRI Journal
    • /
    • v.35 no.1
    • /
    • pp.166-169
    • /
    • 2013
  • In this letter, we propose a data randomization scheme for endurance and interference mitigation of deeply-scaled multilevel flash memory. We address the relationships between data patterns and the raw bit error rate. An on-chip pseudorandom generator composed of an address-based seed location decoder is developed and evaluated with respect to uniformity. Experiments performed with 2x-nm and 4x-nm NAND flash memory devices illustrate the effectiveness of our scheme. The results show that the error rate is reduced up to 86% compared to that of a conventional cycling scheme. Accordingly, the endurance phenomenon can be mitigated through analysis of interference that causes tech shrinkage.