• 제목/요약/키워드: error generator

검색결과 359건 처리시간 0.024초

윤활특성을 고려한 사절경로 발생기구의 기계적 오차해석 및 공차설계 (Mechanical Error Analysis and Tolerance Design of A Four-Bar Path Generator With Lubricated Joints)

  • 최진호;이세정;최동훈
    • 대한기계학회논문집A
    • /
    • 제21권2호
    • /
    • pp.327-336
    • /
    • 1997
  • This paper addresses an analytical approach to the mechanical error analysis and tolerance design of a four-bar path generator with lubricated joints. The mobility method is applied to consider lubrication effects and the four-bar path generator is stochastically modeled by using the clearance vector model for methanical error analysis. To show the validity of the proposed method, the mechanical errors obtained by applying the method to a four-bar path generator are compared with those by Monte Carlo simulation. Based on this analytical method, an optimal tolerance design problem is formulated and solved for the four-bar path generator.

회전축의 정밀 토그 발생용 직류 발전기 제어장치의 설계 및 성능평가에 관한 연구 (Design and Performance Evaluation of DC Generator Control System for Cortrolling Torque of Rotating Shaft)

  • 김갑순;강대임;안병덕
    • 한국정밀공학회지
    • /
    • 제11권6호
    • /
    • pp.50-56
    • /
    • 1994
  • A DC generator control system was designed to control the torque of a rotating shaft precisely. The control system is composed of a strain gage type torque cell, a torque cell amplifier, a computer, a D/A converter, a error detector, a DC voltage amplifier and a resistor. The response test under unit step input and the dynamic stability test for the designed control system were carried out. It was confirmed that the settling time from the response test is about 4 s and the error from the dynamic stability test is less than 0.06% of rated output of torque cell. The designed control system may be used to control a DC generator which may be used to apply torque to a rotating shaft.

  • PDF

교류 발전기 고정자 사고 검출을 위한 최적 마더 웨이브릿의 선정 (A Selection of an Optimal Mother Wavelet for Stator Fault Detection of AC Generator)

  • 박철원
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.377-382
    • /
    • 2008
  • For stator winding protection of AC generator, KCL(Kirchhoff's Current Law) is widely applied. Actually a CRDR(Current Ratio Differential Relay) based on DFT(Discrete Fourier Transform) has been used for protecting generator. It has been pointed out that defects can occur during the process of transforming a time domain signal into a frequency domain one which can lead to loss of time domain information. Wavelets techniques are proposed for the analysis of power system transients. This paper introduces an algorithm to choose a suitable Mother Wave1et for generator stator fault detection. For optimal selection, we analyzed db(Daubechies), sym(Symlets), and coif(Coiflects) of Mother Wavelet. And we compared with performance of the choice algorithm using detail coefficients energy and RMS(root mean square) error. It can be improved the reliability of the conventional DFT based CRDR. The feasibility and effectiveness of the proposed scheme is proved with simulation using collected data obtained from ATP (Alternative Transient Program) package.

Introduction of Generator Unit Controller and Its Tuning for Automatic Generation Control in Korean Energy Management System (K-EMS)

  • Park, Min-Su;Chun, Yeong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권1호
    • /
    • pp.42-47
    • /
    • 2011
  • Automatic generation control (AGC) is an important function for load frequency control, which is being implemented in Energy Management System (EMS). A key feature of AGC is to back up governors to enhance the performance of frequency control. The governor regulates system frequency in several to ten seconds, while the droop control concept results in steady-state control error. AGC is a supplementary tool for compensation of the steady-state error caused by the droop setting of the governors. As the AGC target is delivered to each generator as an open loop control target, the generator output is not guaranteed to follow the AGC target. In this paper, we introduce generating unit controller (GUC) control block, which has the purpose of enabling the generator output to track the AGC target while maintaining the governor performance. We also address the tuning methods of GUC for better performance of AGC in the Korea Energy Management System (K-EMS).

원자력발전소의 증기발생기 수위계측 오차 원인분석 (Cause Analysis of Level Measurement Error in Steam Generator of Nuclear Power Plant)

  • 이광대;오응세;양승옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.591-593
    • /
    • 2006
  • The differential pressure method has been used in the level measurement of steam generator in nuclear power plant. Two sensing lines from a steam generator to a pressure transmitter are needed to measure the high pressure and low pressure. The fluid conditions in the sensing line require the uniform phase with no bubbles and the slope of sensing line should be installed with forward slope. The expansion of the bubble volume according to the upper pressure and the reverse slope of sensing lines explain how the level errors took place.

  • PDF

Design of Fault Tolerant Control System for Steam Generator Using Fuzzy Logic

  • Kim, Myung-Ki;Seo, Mi-Ro
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.321-328
    • /
    • 1998
  • A controller and sensor fault tolerant system jot a steam generator is designed with fuzzy logic. A structure of the : proposed fault tolerant redundant system is composed of a supervisor and two fuzzy weighting modulators. A supervisor alternatively checks a controlled and a sensor induced performances to identify Which Part, a controller or a sensor, is faulty. In order to analyze controller induced performance both an error and a charge in error of the system output an chosen as fuzzy variables. The fuzzy logic jot a sensor induced performance uses two variables : a deviation between two sensor outputs and its frequency, Fuzzy weighting modulator generates an output signal compensated for faulty input signal. Simulations show that the : proposed fault tolerant control scheme jot a steam generator regulates welt water level by suppressing fault effect of either controllers or sensors. Therefore through duplicating sensors and controllers with the proposed fault tolerant scheme, both a reliability of a steam generator control and sensor system and that of a power plant increase even mote.

  • PDF

마이크로프로세서에 의한 WALSH 함수 발생기 구현 (A Microprocessor Based Design of Walsh Function Generator)

  • 안두수;박준훈;이명규;김종부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.303-305
    • /
    • 1993
  • Walsh function and transform are important analytical tools for control theory and signal processing and have wide applications in those fields, especially in the field of digital communications. Therefore there is a need for a Walsh function generator in order to realize certain applications. And a number of different desists are known. But desist and implementation of such a generator through hardware logic nay give rise to orthogonality error. To develop Walsh function generator which gets rid of orthogonality error, this paper presents a microprocessor based design and implementation method.

  • PDF

조기학습정지를 이용한 원전 SG세관 결함크기 예측 신경회로망의 성능 향상 (A performance improvement of neural network for predicting defect size of steam generator tube using early stopping)

  • 조남훈
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.2095-2101
    • /
    • 2008
  • In this paper, we consider a performance improvement of neural network for predicting defect size of steam generator tube using early stopping. Usually, neural network is trained until MSE becomes less than a prescribed error goal. The smaller the error goal, the greater the prediction performance for the trained data. However, as the error goal is decreased, an over fitting is likely to start during supervised training of a neural network, which usually deteriorates the generalization performance. We propose that, for the prediction of an axisymmetric defect size, early stopping can be used to avoid the over-fitting. Through various experiments on the axisymmetric defect samples, we found that the difference bet ween the prediction error of neural network based on early stopping and that of ideal neural network is reasonably small. This indicates that the error goal used for neural network training for the prediction of defect size can be efficiently selected by early stopping.

GNSS 신호생성기에서 DCO 누적오차 보상 알고리즘 (Compensation Algorithm of DCO Cumulative Error in the GNSS Signal Generator)

  • 김태희;신천식;김재훈
    • 한국위성정보통신학회논문지
    • /
    • 제9권2호
    • /
    • pp.119-125
    • /
    • 2014
  • 본 논문에서 우리는 GNSS 항법 신호 생성 시뮬레이터 개발 연구를 수행하고, DCO(Digitally Clock Oscillator) 누적오차로 인한 의사거리 오차를 보상하기 위한 알고리즘을 구현한 후 시뮬레이션을 통하여 성능을 분석하였다. 일반적으로 신호를 생성하기 위하여 위성과 수신기의 위치 정보를 이용하여 초기의사거리 및 도플러를 계산한다. GNSS 신호생성기는 초기 의사거리를 이용하여 신호를 생성할 시점의 비트정보 및 코드정보를 생성하고 시간에 따라 계산된 도플러 정보를 이용하여 코드 및 반송파 출력주파수를 결정한 후 신호를 생성하게 된다. 이때 코드 및 반송파 출력주파수는 DCO를 이용하게 된다. DCO를 누적하여 샘플마다 코드 정보 및 비트정보를 추출하는데 DCO의 누적오차로 인하여 의사거리의 오차가 발생하게 된다. 의사거리 오차가 발생하면 수신기의 항법해에 영향을 주게 된다. 따라서 본 논문에서는 이러한 DCO 누적오차 성분을 제거하기 위한 DCO 누적오차 보상 알고리즘을 구현하고 실험을 통하여 의사거리 누적오차가 제거되며 항법해가 정밀해지는 것을 확인할 수 있었다.

다중 엔트로피를 기반으로 하는 새로운 결정 트리 생성기 MEC (MEC; A new decision tree generator based on multi-base entropy)

  • 전병환;김재희
    • 한국통신학회논문지
    • /
    • 제22권3호
    • /
    • pp.423-431
    • /
    • 1997
  • A new decision tree generator MEC is proposed in this paper, which uses the difference of multi-base entropy as a consistent criterion for discretization and selection of attributes. To evaluate the performance of the proposed generator, it is compared to other generators which use criteria based on entropy and adopt different discretization styles. As an experimental result, it is shown that the proposed generator produces the most efficient classifiers, which have the least number of leaves at the same error rate, regardless of whether attribute values constituting the training set are discrete or continuous.

  • PDF