• Title/Summary/Keyword: error control

Search Result 6,602, Processing Time 0.035 seconds

Development of Continuous Monitoring Method of Root-zone Electrical Conductivity using FDR Sensor in Greenhouse Hydroponics Cultivation (시설 수경재배에서 FDR 센서를 활용한 근권 내 농도의 연속적 모니터링 방법)

  • Lee, Jae Seong;Shin, Jong Hwa
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.409-415
    • /
    • 2022
  • Plant growth and development are also affected by root-zone environment. Therefore, it is important to consider the variables of the root-zone environment when establishing an irrigation strategy. The purpose of this study is to analyze the relationship between the volumetric moisture content (VWC), Bulk EC (ECb), and Pore EC (ECp) used by plant roots using FDR sensors in two types of rockwool media with different water transmission characteristics, using the method above this was used to establish a method for collecting and correcting available root-zone environmental data. For the experiment, two types of rockwool medium (RW1, RW2) with different physical characteristics were used. The moisture content (MC) and ECb were measured using an FDR sensor, ECp was measured after extracting the residual nutrient solution from the medium using a disposable syringe in the center of the medium at a volumetric moisture content (VWC) of 10-100%. Then, ECb and ECp are measured by supplying nutrient solution having different concentration (distilled water, 0.5-5.0) to two types of media (RW1, RW2) in each volume water content range (0 to 100%). The relationship between ECb and ECp in RW1 and RW2 media is best suited for cubic polynomial. The relationship between ECb and ECp according to volume moisture content (VWC) range showed a large error rate in the low volume moisture content (VWC) range of 10-60%. The correlation between the sensor measured value (ECb) and the ECp used by plant roots according to the volumetric water content (VWC) range was the most suitable for the Paraboloid equation in both media (RW1, RW2). The coefficient of determination the calibration equation for RW1 and RW2 media were 0.936, 0.947, respectively.

Model Evaluation for Predicting the Full Bloom Date of Apples Based on Air Temperature Variations in South Korea's Major Production Regions (기온 변화에 따른 우리나라 사과 주산지 만개일 예측을 위한 모델 평가)

  • Jae Hoon Jeong;Jeom Hwa Han;Jung Gun Cho;Dong Yong Lee;Seul Ki Lee;Si Hyeong Jang;Suhyun Ryu
    • Journal of Bio-Environment Control
    • /
    • v.32 no.4
    • /
    • pp.501-512
    • /
    • 2023
  • This study aimed to assess and determine the optimal model for predicting the full bloom date of 'Fuji' apples across South Korea. We evaluated the performance of four distinct models: the Development Rate Model (DVR)1, DVR2, the Chill Days (CD) model, and a sequentially integrated approach that combined the Dynamic model (DM) and the Growing Degree Hours (GDH) model. The full bloom dates and air temperatures were collected over a three-year period from six orchards located in the major apple production regions of South Korea: Pocheon, Hwaseong, Geochang, Cheongsong, Gunwi, and Chungju. Among these models, the one that combined DM for calculating chilling accumulation and the GDH model for estimating heat accumulation in sequence demonstrated the most accurate predictive performance, in contrast to the CD model that exhibited the lowest predictive precision. Furthermore, the DVR1 model exhibited an underestimation error at orchard located in Hwaseong. It projected a faster progression of the full bloom dates than the actual observations. This area is characterized by minimal diurnal temperature ranges, where the daily minimum temperature is high and the daily maximum temperature is relatively low. Therefore, to achieve a comprehensive prediction of the blooming date of 'Fuji' apples across South Korea, it is recommended to integrate a DM model for calculating the necessary chilling accumulation to break dormancy with a GDH model for estimating the requisite heat accumulation for flowering after dormancy release. This results in a combined DM+GDH model recognized as the most effective approach. However, further data collection and evaluation from different regions are needed to further refine its accuracy and applicability.

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

A Study of Microsatellite Instability in Primary Small Cell Lung Cancers by Microsatellite Analysis (원발성 소세포폐암에서 Microsatellite 분석을 이용한 Microsatellite 불안정화에 대한 연구)

  • Cho, Eun-Song;Chang, Joon;Park, Jae-Min;Shin, Dong-Hwan;Kim, Se-Hoon;Kim, Young-Sam;Chang, Yoon-Soo;Cho, Chul-Ho;Kwak, Seung-Min;Lee, Jun-Gu;Chung, Kyung-Young;Kim, Sung-Kyu;Lee, Won-Young;Kim, Se-Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.2
    • /
    • pp.180-190
    • /
    • 2000
  • Background: Genomic instability, which is manifested by the replication error(RER) phenotype, has been proposed for the promotion of genetic alterations necessary for carcinogenesis. Merlo et al. reported frequent microsatellite instability in primary small cell lung cancers. However, Kim et al. found that instability occurred in only 1% of the loci tested and did not resemble the replication error-positive phenotype. The significance of microsatellite instability in the tumorigenesis of small cell lung cancer as well as the relationship between microsatellite instability and its clinical prognosis was investigated in our study. Methods: Fifteen primary small cell lung cancers were chosen for this study. The DNAs extracted from paraffin-embedded tissue blocks with primary tumor and corresponding control tissue were investigated. Forty microsatellite markers on chromosome 1p, 2p, 3p, 5q, 6p, 6q, 9p, 9q, 13q, and 17p were used in the microsatellite analysis. Results: Thirteen(86.7%) of 15 tumors exhibited LOH in at least one of the tested microsatellite markers. Three of 13 tumors exhibiting LOH lost a larger area in chromosome 9p. LOH was shown in 72.7% on chromosome 2p, 40% on 3p, 50% on 5q, 46.7% on 9p, 69.2% on 13q, and 66.7% on 17p(Table 1). Nine(60%) of 15 tumors exhibited shifted bands in at least one of the tested microsatellite markers. Nine cases exhibiting shifted bands showed altered loci ranging 2.5~52.5%(mean $9.4%\pm16.19$)(Table 2). Shifted bands occurred in 5.7% (34 of 600) of the loci tested(Table 2). Nine cases with shifted bands exhibited LOH ranging between 0~83.3%, and the median survival duration of those cases was 35 weeks. Six cases without shifted bands exhibited LOH ranging between 0~83.3%, and the median survival duration of those cases was 73 weeks. There was no significant difference between median survival durations of the two groups(p=0.4712). Conclusion: Microsatellite instability as well as the inactivation of several tumor suppressor genes may play important roles in the development and progression process of tumors. However, the relationship between microsatellite instability and its clinical prognosis in primary small cell lung cancer could not be established.

  • PDF

Plasma Activity of Lysosomal Enzymes in Active Pulmonary Tuberculosis (활동성 폐결핵 환자에서 혈중 리소솜 효소의 활성도)

  • Koh, Youn-Suck;Choi, Jeong-Eun;Kim, Mi-Kyung;Lim, Chae-Man;Kim, Woo-Sung;Chi, Hyun-Sook;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.5
    • /
    • pp.646-653
    • /
    • 1995
  • Background: The confirmative diagnosis of pulmonary tuberculosis(Tb) can be made by the isolation of Mycobacterium Tuberculosis(MTb) in the culture of the sputum, respiratory secretions or tissues of the patients, but positive result could not always be obtained in pulmonary Tb cases. Although there are many indirect ways of the diagnosis of Tb, clinicians still experience the difficulty in the diagnosis of Tb because each method has its own limitation. Therefore development of a new diagnostic tool is clinically urgent. It was reported that silica cause some lysosomal enzymes to be released from macrophages in vitro and one of these enzymes is elevated in workers exposed to silica dust and in silicotic subjects. In pulmonary Tb, alveolar macrophages are known to be activated after ingestion of MTb. Activated macrophages can kill MTb through oxygen free radical species and digestive enzymes of lysosome. But if macrophages allow the bacilli to grow intracellularly, the macrophages will die finally and local lesion will enlarge. Then it is assumed that the lysosomal enzymes would be released from the dead macrophages. The goal of this investigation was to determine if there are differences in the plasma activities of lysosomal enzymes, ($\beta$-glucuronidase(GLU) and $\beta$-N-acetyl glucosaminidase(NAG), among the groups of active and inactive pulmonary Tb and healthy control, and to see if there is any possibility that the plasma activity of GLU and NAG can be used as diagnostic indicies of active pulmonary Tb. Methods: The plasma were obtained from 20 patients with bacteriologically proven active pulmonary Tb, 15 persons with inactive Tb and 20 normal controls. In 10 patients with active pulmonary Tb, serial samples after 2 months of anti-Tb medications were obtained. Plasma GLU and NAG activities were measured by the fluorometric methods using 4-methylumbelliferyl substrates. All data are expressed as the mean $\pm$ the standard error of the mean. Results: The activites of GLU and NAG in plasma of the patients with active Tb were $21.52{\pm}3.01$ and $325.4{\pm}23.37$(nmol product/h/ml of plasma), respectively. Those of inactive pulmonary Tb were $24.87{\pm}3.78$, $362.36{\pm}33.92$ and those of healthy control were $25.45{\pm}4.05$, $324.44{\pm}28.66$(nmol product/h/ml of plasma), respectively. There were no significant differences in the plasma activities of both enzymes among 3 groups. The plasma activities of GLU at 2 months after anti-Tb medications were increased($42.18{\pm}5.94$ nmol product/h/ml of plasma) in the patients with active pulmonary Tb compared with that at the diagnosis of Tb(P-value <0.05). Conclusion: The results of the present investigation suggest that the measurement of the plasma activities of GLU and NAG in the patients with active pulmonary Tb could not be a useful method for the diagnosis of active Tb. Further investigation is necessary to define the reasons why the plasma activities of the GLU was increased in the patients with active pulmonary Tb after Tb therapy.

  • PDF

Why A Multimedia Approach to English Education\ulcorner

  • Keem, Sung-uk
    • Proceedings of the KSPS conference
    • /
    • 1997.07a
    • /
    • pp.176-178
    • /
    • 1997
  • To make a long story short I made up my mind to experiment with a multimedia approach to my classroom presentations two years ago because my ways of giving instructions bored the pants off me as well as my students. My favorite ways used to be sometimes referred to as classical or traditional ones, heavily dependent on the three elements: teacher's mouth, books, and chalk. Some call it the 'MBC method'. To top it off, I tried audio-visuals such as tape recorders, cassette players, VTR, pictures, and you name it, that could help improve my teaching method. And yet I have been unhappy about the results by a trial and error approach. I was determined to look for a better way that would ensure my satisfaction in the first place. What really turned me on was a multimedia CD ROM title, ELLIS (English Language Learning Instructional Systems) developed by Dr. Frank Otto. This is an integrated system of learning English based on advanced computer technology. Inspired by the utility and potential of such a multimedia system for regular classroom or lab instructions, I designed a simple but practical multimedia language learning laboratory in 1994 for the first time in Korea(perhaps for the first time in the world). It was high time that the conventional type of language laboratory(audio-passive) at Hahnnam be replaced because of wear and tear. Prior to this development, in 1991, I put a first CALL(Computer Assisted Language Learning) laboratory equipped with 35 personal computers(286), where students were encouraged to practise English typing, word processing and study English grammar, English vocabulary, and English composition. The first multimedia language learning laboratory was composed of 1) a multimedia personal computer(486DX2 then, now 586), 2) VGA multipliers that enable simultaneous viewing of the screen at control of the instructor, 3) an amplifIer, 4) loud speakers, 5)student monitors, 6) student tables to seat three students(a monitor for two students is more realistic, though), 7) student chairs, 8) an instructor table, and 9) cables. It was augmented later with an Internet hookup. The beauty of this type of multimedia language learning laboratory is the economy of furnishing and maintaining it. There is no need of darkening the facilities, which is a must when an LCD/beam projector is preferred in the laboratory. It is headset free, which proved to make students exasperated when worn more than- twenty minutes. In the previous semester I taught three different subjects: Freshman English Lab, English Phonetics, and Listening Comprehension Intermediate. I used CD ROM titles like ELLIS, Master Pronunciation, English Tripple Play Plus, English Arcade, Living Books, Q-Steps, English Discoveries, Compton's Encyclopedia. On the other hand, I managed to put all teaching materials into PowerPoint, where letters, photo, graphic, animation, audio, and video files are orderly stored in terms of slides. It takes time for me to prepare my teaching materials via PowerPoint, but it is a wonderful tool for the sake of presentations. And it is worth trying as long as I can entertain my students in such a way. Once everything is put into the computer, I feel relaxed and a bit excited watching my students enjoy my presentations. It appears to be great fun for students because they have never experienced this type of instruction. This is how I freed myself from having to manipulate a cassette tape player, VTR, and write on the board. The student monitors in front of them seem to help them concentrate on what they see, combined with what they hear. All I have to do is to simply click a mouse to give presentations and explanations, when necessary. I use a remote mouse, which prevents me from sitting at the instructor table. Instead, I can walk around in the room and enjoy freer interactions with students. Using this instrument, I can also have my students participate in the presentation. In particular, I invite my students to manipulate the computer using the remote mouse from the student's seat not from the instructor's seat. Every student appears to be fascinated with my multimedia approach to English teaching because of its unique nature as a new teaching tool as we face the 21st century. They all agree that the multimedia way is an interesting and fascinating way of learning to satisfy their needs. Above all, it helps lighten their drudgery in the classroom. They feel other subjects taught by other teachers should be treated in the same fashion. A multimedia approach to education is impossible without the advent of hi-tech computers, of which multi functions are integrated into a unified system, i.e., a personal computer. If you have computer-phobia, make quick friends with it; the sooner, the better. It can be a wonderful assistant to you. It is the Internet that I pay close attention to in conjunction with the multimedia approach to English education. Via e-mail system, I encourage my students to write to me in English. I encourage them to enjoy chatting with people all over the world. I also encourage them to visit the sites where they offer study courses in English conversation, vocabulary, idiomatic expressions, reading, and writing. I help them search any subject they want to via World Wide Web. Some day in the near future it will be the hub of learning for everybody. It will eventually free students from books, teachers, libraries, classrooms, and boredom. I will keep exploring better ways to give satisfying instructions to my students who deserve my entertainment.

  • PDF

A Study on eDesign Platform for Effective Communication and Information sharing - with an emphasis on process and template (효과적인 커뮤니케이션과 정보공유를 위한 e디자인 플랫폼 구축에 관한 연구 - 프로세스와 템플릿을 중심으로)

  • 윤주현
    • Archives of design research
    • /
    • v.17 no.2
    • /
    • pp.425-436
    • /
    • 2004
  • A new design field called eDesign appears as if eBiz is an online related business in which an industrialized design creates the individual value added facing a digital revolution. The field of eDesign requires a special design process and management methodology regardless of the fact that human sensitivity will be satisfied through a dehumanized computer technique. However, it is the reality of eDesign that has been dependent upon a simple process or project management tool of general design. In this study, we develop an eDesign platform based on an eDesign process and template mainly focused on eBusiness in order to overcome the wrong situation. The template is a kind of document that has a standardization form. We aim to establish a general process through various case projects, store information using a necessary template, and use for the way of visual communication. We propose a standard of eDesign platform that can be widely applied to the field of design, medium and small enterprises focused on IT businesses or design-team through this project performed as an educational-industrial study. It makes it possible to get a detailed process methodology, which can be applied to many small design related companies that don't have their own process yet, and will be a scale for comparing their own process in which the company has a process of opened standard eDesign with it. In addition, it makes possible a systematic control of the own projects within and outside the firm, accumulating information for the firm through the database, and easy communication. Furthermore, it can be applied to check the process of the project as a checklist, and then it will reduce trial and error repeated for every project that has been done.

  • PDF

Hydrogeochemistry and Statistical Analysis of Water Quality for Small Potable Water Supply System in Nonsan Area (논산지역 마을상수도 수질의 수리지화학 및 통계 분석)

  • Ko, Kyung-Seok;Ahn, Joo-Sung;Suk, Hee-Jun;Lee, Jin-Soo;Kim, Hyeong-Soo
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.6
    • /
    • pp.72-84
    • /
    • 2008
  • This study was carried out to provide proper management plans for small portable water supply system in the Nonsan area through water quality monitoring, hydrogeochemical investigation and multivariate statistical analyses. Nonsan area is a typical rural area heavily depending on small water supply system for portable usage. Geology of the area is composed of granite dominantly along with metasedimentary rocks, gneiss and volcanic rocks. The monitoring results of small portable water supply system showed that 13-21% of groundwaters have exceeded the groundwater standard for drinking water, which is 5 to 8 times higher than the results from the whole country survey (2.5% in average). The major components exceeding the standard limits are nitrate-nitrogen, turbidity, total coliform, bacteria, fluoride and arsenic. High nitrate contamination observed at southern and northern parts of the study area seems to be caused by cultivation practices such as greenhouses. Although Ca and $HCO_3$ are dominant species in groundwater, concentrations of Na, Cl and $NO_3$ have increased at the granitic area indicating anthropogenic contamination. The groundwaters are divided into 2 groups, granite and metasedimentary rock/gneiss areas, with the second principal component presenting anthropogenic pollution by cultivation and residence from the principal components analysis. The discriminant analysis, with an error of 5.56% between initial classification and prediction on geology, can explain more clearly the geochemical characteristics of groundwaters by geology than the principal components analysis. Based on the obtained results, it is considered that the multivariate statistical analysis can be used as an effective method to analyze the integrated hydrogeochemical characteristics and to clearly discriminate variations of the groundwater quality. The research results of small potable water supply system in the study area showed that the groundwater chemistry is determined by the mixed influence of land use, soil properties, and topography which are controlled by geology. To properly control and manage small water supply systems for central and local governments, it is recommended to construct a total database system for groundwater environment including geology, land use, and topography.

A study on accuracy and application of the implant torque controller used in dental clinic (임상에서 사용하고 있는 임플란트 토크조절기의 정확도와 적용에 관한 사용실태)

  • Joo, Young-Hun;Lee, Jin-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.197-205
    • /
    • 2011
  • Purpose: This study was to evaluate the accuracy of the implant torque controller used in dental clinics and to investigate whether it was applied appropriately. Materials and methods: Fifty dentists who work in dental clinics were enrolled in this study. Dental (implant) practice career, experience frequency of implant screw loosening and fracture, education of implant torque controller application and infection control methods were included in the survey. 25 Ncm and 30 Ncm of the tightening torque applied to the implant screw were measured by 50 clinicians. After measuring the torque value by using the torque controller, the torque mean according to where education about the implant torque controller was received was analyzed with independent t-test at the significance level of 0.05. Results: The torque controller used in private dental clinics showed 4.78% error ratio. When 50 dentists applied 25 Ncm to the implant screw was $29.0{\pm}8.4$ Ncm, and that in 30 Ncm was $34.3{\pm}9.1$ Ncm. Statistical significance was found between the group that was educated about implant torque application and the group that was not educated. Conclusion: During the prosthodontic treatment with implant, there was difference between actual applied torsion force and the amount torque controller indicated. Clinicians have to not only be well-informed about the accurate usage method of the torque controller, but also keep and manage the torque controller so as to maintain continuous and accurate torque values. Through this, it is considered to achieve clinical results to minimize problems of screw loosening or fracture.

Inferring the Transit Trip Destination Zone of Smart Card User Using Trip Chain Structure (통행사슬 구조를 이용한 교통카드 이용자의 대중교통 통행종점 추정)

  • SHIN, Kangwon
    • Journal of Korean Society of Transportation
    • /
    • v.34 no.5
    • /
    • pp.437-448
    • /
    • 2016
  • Some previous researches suggested a transit trip destination inference method by constructing trip chains with incomplete(missing destination) smart card dataset obtained on the entry fare control systems. To explore the feasibility of the transit trip destination inference method, the transit trip chains are constructed from the pre-paid smart card tagging data collected in Busan on October 2014 weekdays by tracing the card IDs, tagging times(boarding, alighting, transfer), and the trip linking distances between two consecutive transit trips in a daily sequences. Assuming that most trips in the transit trip chains are linked successively, the individual transit trip destination zones are inferred as the consecutive linking trip's origin zones. Applying the model to the complete trips with observed OD reveals that about 82% of the inferred trip destinations are the same as those of the observed trip destinations and the inference error defined as the difference in distance between the inferred and observed alighting stops is minimized when the trip linking distance is less than or equal to 0.5km. When applying the model to the incomplete trips with missing destinations, the overall destination missing rate decreases from 71.40% to 21.74% and approximately 77% of the destination missing trips are the single transit trips for which the destinations can not be inferable. In addition, the model remarkably reduces the destination missing rate of the multiple incomplete transit trips from 69.56% to 6.27%. Spearman's rank correlation and Chi-squared goodness-of-fit tests showed that the ranks for transit trips of each zone are not significantly affected by the inferred trips, but the transit trip distributions only using small complete trips are significantly different from those using complete and inferred trips. Therefore, it is concluded that the model should be applicable to derive a realistic transit trip patterns in cities with the incomplete smart card data.