• Title/Summary/Keyword: equivalent test

Search Result 1,960, Processing Time 0.044 seconds

A New Extraction Method of GaAs/InGaP HBT Small-signal Equivalent Circuit Model Parameters (GaAs/InGaP HBT 소신호 등가회로 모델 파라미터의 새로운 추출방법)

  • 이명규;윤경식
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.357-360
    • /
    • 2000
  • This paper describes a parameter extraction method for HBT(Heterojunction Bipolar Transistor) equivalent circuit model without measurements of special test structures or numerical optimizations. Instead, all equivalent circuit parameters are calculated analytically from small-signal S-parameters measured under different bias conditions. These values being extracted from the cutoff mode can be used to extract intrinsic parameters at the active mode. This method yields a deviation of about 1.3 % between the measured and modeled S-parameters.

  • PDF

An Experimental Study on Post-Crack Equivalent Strength of Steel Fiber Reinforced Concrete (강섬유보강 콘크리트의 균열 후 등가인장강도에 관한 실험적 연구)

  • 박홍용;안영진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.635-638
    • /
    • 2000
  • This experimental were carried out in order to investigate the equivalent strength of SFRC (Steel Fiber Reinforced Concrete). Tow hundred and tenh SFRC beeam (size: 150x150x550) were used in the tests the relationships between loading and mid-point deflections of the beams were observed four oint bending loading. From the test results, prediction formulas for the equivalent strength of SFRC beams are suggested.

  • PDF

Evaluation of Internal Blast Overpressures in Test Rooms of Elcetric Vehicles Battery with Pressure Relief Vents (압력배출구를 설치한 전동화 차량 배터리 시험실의 내부 폭압 평가)

  • Pang, Seungki;Shin, Jinwon;Jeong, Hyunjin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.3
    • /
    • pp.7-18
    • /
    • 2022
  • Secondary batteries used in electric vehicles have a potential risk of ignition and explosion. Various safety measures are being taken to prevent these risks. A numerical study was performed using a computational fluid dynamics code on the cases where pressure relief vents that can reduce the blast overpressures of batteries were installed in the through-compression test room, short-circuit drop test room, combustion test room, and immersion test room in facilities rleated to battery used in electric vehicles. This study was conducted using the weight of TNT equivalent to the energy release from the battery, where the the thermal runaway energy was set to 324,000 kJ for the capacity of the lithium-ion battery was 90 kWh and the state of charge (SOC) of the battery of 100%. The explosion energy of TNT (△HTNT) generally has a range of 4,437 to 4,765 kJ/kg, and a value of 4,500 kJ/kg was thus used in this study. The dimensionless explosion efficiency coefficient was defined as 15% assuming the most unfavorable condition, and the TNT equivalent mass was calculated to be 11 kg. The internal explosion generated in a test room shows the very complex propagation behavior of blast waves. The shock wave generated after the explosion creates reflected shock waves on all inner surfaces. If the internally reflected shock waves are not effectively released to the outside, the overpressures inside are increased or maintained due to the continuous reflection and superposition from the inside for a long time. Blast simulations for internal explosion targeting four test rooms with pressure relief vents installed were herein conducted. It was found that that the maximum blast overpressure of 34.69 bar occurred on the rear wall of the immersion test room, and the smallest blast overpressure was calculated to be 3.58 bar on the side wall of the short-circuit drop test room.

A Study on the Parameters and Characteristic of Induction Motor driven by Inverter (인버터로 구동되는 유도전동기의 정수 및 특성에 관한 연구)

  • 전내석;김종윤;오진석;김윤식
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.497-504
    • /
    • 2000
  • This paper presents a method for the equivalent-circuit parameters and torque characteristics calculation of squirrel-cage induction motors. The measurment of motor parameters were calculated by the stator resistance test, the blocked rotor test and no load test through T type equivalent-circuit method. Especially, this paper describes the test results obtained by using hall sensor and strain gage for the current and the torque characteristics of induction motors. 1(HP), three-phase squirrel cage induction motor has been used during the test and the parameters are compared with those obtained by the maker parameters of simulation results and experiment.

  • PDF

Pullout Test of Headed Reinforcement 2: Deep Embedment

  • Choi, Dong Uk;Shin, InYong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.1091-1096
    • /
    • 2003
  • Pullout tests of single headed bars using plain concrete blocks indicate that the embedment depth of $10d_b$ is in general required for the headed bars to develop pullout strength equivalent to 125% of bar yield strength. In this experimental study, test results of multiple headed bars installed in reinforced concrete column sections are presented. Test variables included embedment depth, column main reinforcement ratio, and spacing of column ties. 2D29 bars were pulled out at one time from normal strength concrete. Test results indicated that the embedment depths, column tie spacings, and column main reinforcement ratios all influenced the pullout strengths of the headed bars. When the embedment depth was not sufficient, narrow tie spacings especially resulted in increased pullout strengths of the headed bars. Test results also indicated that the embedment depth of 15㏈ was sufficient for the closely spaced two headed bars (head-to-head spacing =$6d_b$) to develop pullout strength equivalent to 125% of the bar yield strength.

  • PDF

A Study on the Parameters and Characteristics of Induction Motor Driven by Inverter (인버터로 구동되는 유도전동기의 정수 및 특성에 관한 연구)

  • 전내석;김종윤;오진석;김윤식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.6
    • /
    • pp.34-42
    • /
    • 2000
  • In this paper conventional technique will be described, which can be used for the measuring various parameters of induction motor. This is followed by presenting some other, alternative, techniques. The two tests are described which are suitable to obtain the electrical parameters of symmetrical 1hp three-phase squirrel-cage induction motor. These are the blocked rotor test and no load test. By the application of these, it is possible to determine the parameters which are presented in the steady-state equivalent-circuit of determining an induction motor. One conventional method of determining the inertia of an induction motors is obtained by performing retardation tests. The angular rotor speed of the motor is monitored, following its disconnection from the stator supply. Since the inertia torque J dw/dt contains the inertia coefficient J and the friction and windage torque Bw contains the coefficient B, then J and B can be determined by performing retardation tests.

  • PDF

Parameters Estimation of Five-phase Squirrel-Cage Induction Motor (5상 농형 유도전동기의 정수 추정)

  • Kim, Min-Huei
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.4
    • /
    • pp.199-205
    • /
    • 2012
  • This paper propose a improved parameter estimations of five-phase squirrel-cage induction motor(IM) for speed control system on field oriented control(FOC). In order to high performance control of ac the motors using a FOC and DTC(direct torque control) algorithm, there are required precise motor parameters for slip calculation, flux observer, controller gain, rotor position and speed estimation, and so on. We are suggest a estimation method of the motor parameters that developing five-phase squirrel-cage IM have a stator of concentrated winding for experimental. There are results of stator winding test, no-load test, locked rotor test, and obtained equivalent circuits using manufactured experimental apparatus. For presenting the superior performance of the speed control system in adapted the parameters, experimental results are presented using a 32-bit fixed point TMS320F2812 DSP with 1.5[KW] IM.

A Comparison Study between Top-down Load Test and Bi-directional Load Test Analysis Method in Rock-socketed Small Size Drilled Shaft (암반소켓된 소구경 현장타설말뚝의 정재하시험과 양방향재하시험 분석법 비교연구)

  • Song, Myungjun;Song, Younghun;Jung, Minhyung;Park, Youngho;Park, Jaehyun;Lee, Juhyung;Chung, Moonkyung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.9
    • /
    • pp.5-12
    • /
    • 2013
  • In this study, each top-down load test and bi-directional load test has been performed on the 480mm diameter of two rock socketed drilled shafts, which are located next to each other, and the results have been compared. The result shows that the settlement from the equivalent load-settlement curve of bi-directional load test is smaller than one from top-down load test, because elastic is not considered in equivalent load-settlement curve of bi-directional load test. Therefore elastic shortening should be considered to obtain appropriate equivalent load-settlement curve. Three existing methods used to obtain equivalent load-settlement curve with consideration of elastic shortening has been compared with the result of top-down load test. The result shows that those existing methods are sufficiently applicable to the design. In addition, result of comparison between top-down load test and bi-directional load test shows that bi-directional load test was found to overestimate bearing capacity because it does not consider pile body failure.

Equivalent Circuit Composition of a Linear Induction Motor (선형유도전동기의 등가회로 구성 - LIM의 T형 등가회로 산정을 위한 구속시험 -)

  • Jang, S.M.;Lee, H.G.;Park, Y.T.;Kim, B.S.;Jeong, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.47-49
    • /
    • 1996
  • The equivalent circuit of LIM is generally composed as the same that of rotary induction motor. However it is very difficult to move the LIM at synchronous velocity for open-secondary circuit test. The resistance representing the core losses in the primary core can not be ignored because the air-gap of LIM is larger than that of rotary induction motor. In this paper, the T-type equivalent circuit of a LIM with the core loss resistance is chosen using static zero slip test and theoritical analysis.

  • PDF

Simplified 3D Finite Element Analysis of Linear Inductor Motor for Integrated Magnetic Suspension/Propulsion Applications (자기부상 및 추진 일체형 리니어 인덕터 모터의 간이형 3차원 유한요소해석)

  • Jeong, Sang-Sub;Jang, Seok-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.6
    • /
    • pp.371-379
    • /
    • 2000
  • The 4-pole linear homopolar synchronous motor (LHSM), so called linear inductor motor, is composed of the figure-of-eight shaped 3-phase armature windings, DC field windings, and the segmented secondary with the transverse bar track. To reduce the calculation time, the simplified 3D finite element model with equivalent reluctance and/or permanent magnet is presented. To obtain a clear understanding, propriety and usefulness of the developed model, we compare with the results of simplified 3D FEA, general 3D FEA and test. Consequently, the results of simplified and 3D FEM analysis are nearly identical, but much larger than that of static test at d-axis armature excitation. Therefore the improved FEA model, such as full model with half slot, is needed for the precise analysis.

  • PDF