• Title/Summary/Keyword: equivalent test

Search Result 1,964, Processing Time 0.027 seconds

Measurement of Ventilatory Threshold in the Patients with Chronic Airway Obstruction (만성기도폐쇄를 보이는 환자에서 환기성역치 측정)

  • Lee, Kye-Young;Jee, Young-Koo;Kim, Keun-Yeol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.309-320
    • /
    • 1997
  • Background : There are many suggested methods for the indirect determination of anaerobic threshold(AT) using the changes of ventilatory parameters in response to ventilatory load accompanying the increase of blood lactic acid level during exercise and the threshold derived from them is called ventilatory threshold(VT). They include ventilatory equivalent method(VEM), End-tidal $PO_2$ method($PETO_2$). V-slope method(VSM), and respiratory quotient method(RQ). But in the patients with chronic airway obstruction(CAO), the AT determined by ventilatory methods may not reflect true AT because the patients with CAO show inadequate ventilatory response to the increase of blood lactic acid level during excercise. Methods : For the investigation of detection rate and reliability of above four VT determination methods in the patients with CAO, we performed the symptom-limited and maximal incremental exercise test in 17 patients with CAO and 12 normal controls. The incremental workload was 10 W /min in CAO group and 25 W/min in control group. The reliability of VT in each group was investigated by the calculation of Spearman correlation coefficient. Results : The detection rates of VT were 100% by RQ, 91.7% by both VEM and $POETO_2$, and 83.3% by VSM in normal control group, while 94.1% by RQ, 64.7% by VEM and $PETO_2$, and 83.3% by VSM in CAO group. Good correlations were noted among VEM, $POETO_2$, and VSM except RQ in normal control group. But there was no significant correlation except between VEM and $PETO_2$ in CAO group. Conclusions : RQ is very sensitive but crude and VEM is near similar to $PETO_2$. The clinical usefulness of VT determined by ventilatory method might be limited in patients with severe CAO.

  • PDF

Changes in Circulatory and Respiratory Activities Observed on Men in an Engine Room of a Navy Ship (함정 기관실내 활동의 순환 및 호흡 기능에 대한 영향)

  • Hyun, Kwang-Chul;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.1 no.2
    • /
    • pp.199-213
    • /
    • 1967
  • Circulatory and respiratory activities were observed in men exposed to the environment of engine room of a cruising Republic of Korea Navy ship and compared to the control values obtained in an ordinary laboratory room on land. The environment of an engine room of cruising navy ship was presumed to be a multiple stress acting on men. The environment of the engine room included high temperature $(35-42^{\circ}C)$, low relative humidity (20-38% saturation), vibration (about 7 cycles per second), rolling and pitching of ship and noises. Sixteen men were divided into two groups consisted of each 8 subjects. Subjects of sea duty group had experience of continuous on board duty averaging 3.5 years. Men of land duty group had no experience of on board activity. On land observations were made on one day prior to the boarding and leaving the port and four days after landing. In between observations in the engine room were made on the first, 5 th, 9 th, 12 th, and 14 th day of on board activity. The whole experimental period lasted for 20 days. Measurements on circulatory and respiratory parameters were at standing resting state (after 30 minutes standing in the case of on land study and 15 minutes in engine room study) and within one minute after cessation of on the spot running of which rhythm was 30/min. and lasted for 5 minutes. Oxygen consumption and pulmonary function test were done in the period of two minutes from the 3rd to 5th minutes of running. The following results were obtained. 1. Body temperature showed no change regardless of group difference or on land or on board measurements. 2. Pulse rate increased markedly after boarding the ship id both groups. Pulse rate increased from the first day on board at rest and after exercise as compared to the on land control value. This increase in pulse rate was more marked after exercise. Sea duty group showed less increase in pulse rate at rest than the land duty group. Standing and resting pulse rate of sea duty group on lam was 81 and increased to 87 at the 5th day on board and remained smaller than the land duty group throughout the period on board. Control standing and resting pulse rate of land duty group on land was 76 and reached 89 at the 9th day on board and thereafter decreased a little. Pulse rate of land duty group at rest on board remained greater than that of sea duty group throughout the period on board. 3. Systolic blood pressure of sea duty group increased after boarding the ship and remained higher than the control value on land. In the land duty group, however, systolic blood pressure decreased during the period on board the ship. Diastolic blood pressure decreased in both groups. 4. Resting breathing rate of land duty group increased and remained higher than the control value on land. In sea duty group, however, resting breathing rate showed a transient increase on the 1st day on board and decreased thereafter to the control value on land and kept the same level throughout the period of cruise. Absolute value of breathing rate in the sea duty group was greater than the land duty group both at rest and after exercise. 5. There was a lowering of breathing efficiency in both groups. Thus, increases in tidal volume and minute ventilation volume and decreases in maximum breathing capacity, vital capacity, capacity ratio and air velocity Index were observed after boarding the ship. An increase in ventilation equivalent was also observed in both groups. The lowering of breathing efficiency was more marked in the land duty group than the sea duty group. 6. Energy expediture increased in both groups during their stay on the ship and was more marked in the sea duty group. 7, Lactate concentration in venous blood at rest and after exercise increased after boarding the ship and no group difference was observed.

  • PDF

The Effect of the Instruction Using PSpice Simulation in 'Digital Logic Circuit' Subject at Industrial High School (공업계열 전문계고등학교 '디지털 논리 회로' 수업에서 PSpice를 이용한 수업의 효과)

  • Choi, Seung-Woo;Woo, Sang-Ho;Kim, Jinsoo
    • 대한공업교육학회지
    • /
    • v.33 no.1
    • /
    • pp.149-168
    • /
    • 2008
  • The purpose of this study is to verify the effect of PSpice instruction on academic achievement in 'Combination logic circuit' unit of 'Digital Logic Circuit' in industrial high school. Three kinds of null hypotheses were formulated. Two classes of the third grade of C technical high school in Gyeong-buk were divided into experimental group and control group in order to verify null hypotheses. In the experimental design, 'Non-equivalent control group pretest-posttest' model was utilized. This experiment was conducted for six classes, the experimental group was applied to PSpice instruction method before the circuit traning while the control group was applied to traditional lecture oriented method before the circuit traning. Window SPSS 10.0 korean language version program was used for the data analysis and independent sample t-test was used to identify the average of each group. Significance level was set to .05 level. The results obtained in this study were as follows; First, PSpice instruction had not an effect on academic achievement according to a group type. However, these instruction had an effect on the following sub-domains; the psychomotor domain. Second, PSpice instruction had not an effect on academic achievement according to a studies level. However, these instruction for middle and low level students had an effect on the cognitive and psychomotor domain, and for middle level students had an effect on the affective domain. Third, PSpice instruction had not an effect on shortening of a training requirement. However, this instruction for low level students had an effect on shortening of a training requirement. The study results of simulation instruction was chiefly efficient in the psychomotor domain. We could know that simulation instruction is efficient as went to a low level students than an upper level students. Thus, We may make the study effectiveness in various instruction method.

Preferential Flow as Tested by Breakthrough Curves of Cl- and Cu2+ from Saturated Undisturbed Soil Core Samples under Steady Flow Conditions (포화 불교란 토양시료의 Cl- 및 Cu2+ 출현곡선에 의한 preferential flow의 검증)

  • Yoo, Sun-Ho;Han, Kyung-Hwa;Ro, Hee-Myong;Han, Gwang-Hyun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.33 no.2
    • /
    • pp.71-78
    • /
    • 2000
  • Preferential flow has recently been the subject of increasing interest because these phenomena contribute to solute transport in soils. Commonly, preferential flow paths are associated with macropores or highly structured soils. We presented an analysis of the measured breakthrough curves (BTCs) of $Cl^-$ and $Cu^{2+}$ ions to test the occurrence of preferential flow in soils using miscible displacement technique under steady flow conditions. We also analyzed soil water retention curves and from this curves induced cumulative pore size distribution of undisturbed soils, which sampled from Ap1, B1, and C horizons of Songjeong series soils (the fine loamy, mesic family of Typic Hapludults). In this study, miscible displacement experiment on C horizon was excluded, because it is structureless sandy loam with saturated hydraulic conductivity of $5.2cmhr^{-1}$. The saturated hydraulic conductivity of Ap1 horizon was $2.0cmhr^{-1}$, which was about 7 times higher than that of B1 horizon ($0.27cm hr^{-1}$). Cumulative pore size distribution predicted that Ap1 horizon had more macropores (pore diameter larger than $49{\mu}m$, equivalent to -6 kpa of soil matric potential) than B1 horizon. The hydrodynamic dispersion coefficient from chloride BTCs was estimated as $1.3cm^2hr^{-1}$ for B1 and $34cm^2hr^{-1}$ for Ap1 horizon. However the retardation factors of B1 and Ap1 horizon were significantly different, i.e. 1 and 0.6, respectively, which means that there was distinct partition between mobile water and immobile phase in Ap1 horizon. The copper retardation effect of Ap1 horizon was less than that of B1 horizon, even though cation exchange capacity of Ap1 horizon was higher than that of B1 horizon. Thus, breakthrough curves of $Cl^-$ and $Cu^{2+}$ obviously showed the probability that preferential flow would occur in Ap1 horizon.

  • PDF

Three-Dimensional Dosimetry Using Magnetic Resonance Imaging of Polymer Gel (중합체 겔과 자기공명영상을 이용한 3차원 선량분포 측정)

  • Oh Young-Taek;Kang Haejin;Kim Miwha;Chun Mison;Kang Seung-Hee;Suh Chang Ok;Chu Seong Sil;Seong Jinsil;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.264-273
    • /
    • 2002
  • Purpose : Three-dimensional radiation dosimetry using magnetic resonance imaging of polymer gel was recently introduced. This dosimetry system is based on radiation induced chain polymerization of acrylic monomers in a muscle equivalent gel and provide accurate 3 dimensional dose distribution. We planned this study to evaluate the clinical value of this 3-dimensional dosimetry. Materials and Methods: The polymer gel poured into a cylindrical glass flask and a spherical glass flask. The cylindrical test tubes were for dose response evaluation and the spherical flasks, which is comparable to the human head, were for isodose curves. T2 maps from MR images were calculated using software, IDL. Dose distributions have been displayed for dosimetry. The same spherical flask of gel and the same irradiation technique was used for film and TLD dosimetry and compared with each other. Results : The R2 of the gel respond linearly with radiation doses in the range of 2 to 15 Gy. The repeated dosimetry of spherical gel showed the same isodose curves. These isodose curves were identical to dose distributions from treatment planning system especially high dose range. In addition, the gel dosimetry system showed comparable or superior results with the film and TLD dosimetry. Conclusion : The 3-dimensional dosimetry for conformal radiation therapy using MRI of polymer gal showed stable and accurate results. Although more studies are needed for convenient clinical application, it appears to be a useful tool for conformal radiation therapy.

Physical properties of novel composite using Portland cement for retro-filling material (치근단 역충전용 포틀랜드 시멘트 신복합재료의 물리적 성질 고찰)

  • Lee, Sang-Jin;Cho, Ok-In;Yum, Ji-Wan;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.445-452
    • /
    • 2010
  • Objectives: The aim of this study was to compare apical sealing ability and physical properties of MTA, MTA - AH-plus mixture (AMTA) and experimental Portland cement - Epoxy resin mixture (EPPC) for a development of a novel retro-filling material. Materials and Methods: Forty-nine extracted roots were instrumented and filled with gutta-percha. Apical root was resected at 3 mm and the retro-filling cavity was prepared for 3 mm depth. Roots were randomly divided into 3 groups of 15 roots each. The retro-filling was done using MTA, AMTA, and EPPC as the groups divided. Four roots were used as control groups. After setting in humid condition for 24 hours, the roots were immersed in 1% methylene blue dye solution for 72 hours to test the apical leakage. After immersion, the roots were vertically sectioned and photos were taken to evaluate microleakage. Setting times were measured with Vicat apparatus and digital radiographs were taken to evaluate aluminum equivalent thickness using aluminum step wedge. The results of microleakage and setting time were compared between groups using one-way ANOVA and Scheffe's post-hoc comparison at the significance level of 95%. Results: AMTA and EPPC showed less microleakage than MTA group (p < 0.05). AMTA showed the highest radio-opacity than other groups and the novel EPPC showed 5 mm aluminum thickness radio-opacity. EPPC showed the shortest initial and final setting times than other groups while the MTA showed the longest (p < 0.05). Conclusions: Under the condition of this study, the novel composite using Portland cement-Epoxy resin mixture may useful for retro-filling with the properties of favorable leakage resistance, radio-opacity and short setting time.

Antioxidant Activity of Extracts from Smilax china Root (청미래덩굴(Smilax china) 뿌리 추출물의 항산화활성 효과)

  • Song, Hee-Sun;Park, Yeon-Hee;Jung, Sae-Heung;Kim, Dong-Pil;Jung, Yong-Hee;Lee, Mi-Kyung;Moon, Ki-Young
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.9
    • /
    • pp.1133-1138
    • /
    • 2006
  • Smilax china root has been used as traditional medicinal remedy in China and Korea and reported to have various biological activities such as anti-inflammatory, antimutagenic and antimicrobial activities. In this study, the possibility of development as natural antioxidants of Smilax china root extracts was investigated. For the evaluation of antioxidant activity, aqueous- and 25% EtOH extract from Smilax china root were prepared and six different evaluation assay methods, i.e., measurement of total phenolics, radical scavenging effects on 1,1-diphenyl-2-picrylhydrazyl (DPPH), nitric oxide (NO) and nitrite $(NO_2)$, reducing power, and inhibitory effect on tyrosinase activity, were used. The total phenolics content of two extracts was high as the level of 36 mg of gallic acid equivalent per 1 g of dried sample tested. The radical scavenging activities of ethanol extract toward DPPH and NO were better than those of aqueous extract (p<0.05). The $NO_2$ scavenging activity of both extracts showed the highest value at pH 1.2 (98%). Especially, the $NO_2$ scavenging activities of EtOH extract were significantly stronger than those of aqueous one at pH 4.2 (51%) and pH 6.0 (32%), respectively. In the reducing power test, both extracts revealed higher ferric ion reducing activity than known antioxidant, vitamin C at the level of $0.05\sim0.1mg/mL$ (p<0.01). The 1 mL of aqueous and 25% EtOH extract showed effective inhibition activity on tyrosinase activity as 45% and 53%, respectively. Therefore, these results suggest that two extracts from Smilax china root may serve as useful natural antioxidants.

Correlation between Corneal Ablation Amount and Intraocular Pressure after Corneal Refractive Surgery (각막굴절교정수술 후 각막절삭량과 안압변화의 상관관계)

  • Jung, Mi-A;Lee, Eun-Hee
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.543-551
    • /
    • 2018
  • Purpose : The purposes of this study were to evaluate the changes of intraocular pressure according to corneal ablation amount after corneal refractive surgery and the changes of intraocular pressure according to refractive errors before corneal refractive surgery. Methods : The mean age of adults who underwent LASIK corneal refractive surgery were $37.34{\pm}7.42years$, and 108 adults(48 males, 60 females) were participated in this study. Refractive errors, intraocular pressure, and corneal ablation amount were measured using an autorefractor, a noncontact tonometer, and an excimer laser. All test values were considered statistically significant when p<0.05. Results : The mean intraocular pressure before corneal refractive surgery was $15.08{\pm}2.60mmHg$ in males and $14.16{\pm}2.67mmHg$ in females. The decrease of intraocular pressure after corneal refractive surgery were 4.22mmHg in males and 3.61mmHg in females. Spherical equivalent power were $-3.89{\pm}2.17D$ in males and $-4.45{\pm}2.92D$ in females before corneal refractive surgery, and $-0.10{\pm}0.46D$ in males and $-0.04{\pm}0.46D$ in females after corneal refractive surgery. The corneal ablation amount after corneal refractive surgery were statistically significant, with $53.95{\mu}m$ in males and $61.26{\mu}m$ in females. There was significant correlation between corneal ablation amount and decrease of intaocluar pressure(r=0.2299, p<0.001). As the growth of corneal ablation amount in males, the decrease of intraocular pressure was significantly increased. As the growth of refractive error, the amount of decrease in intraocular pressure was also significant. The decrease of intraocualr pressure were $3.04{\pm}2.18mmHg$ in low refractive error, $4.10{\pm}2.16mmHg$ in middle refractive error, and $4.65{\pm}3.29mmHg$ in high refractive error. Conclusion : We found that intraocular pressure decreased after corneal refractive surgery by noncontact tonometer and the change of intraocular pressure which is an important index for glaucoma diagnosis, may affect the judgment of eye disease. We think that a preliminary questionnaire whether corneal refractive surgery is necessary for the measurement of intraocular pressure.

Monitoring of Concrete Deterioration Caused by Steel Corrosion using Electrochemical Impedance Spectroscopy(EIS) (EIS를 활용한 철근 부식에 따른 콘크리트 손상 모니터링)

  • Woo, Seong-Yeop;Kim, Je-Kyoung;Yee, Jurng-Jae;Kee, Seong-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.651-662
    • /
    • 2022
  • The electrochemical impedance spectroscopy(EIS) method was used to evaluate the concrete deterioration process related to chloride-induced steel corrosion with various corrosion levels(initiation, rust propagation and acceleration periods). The impressed current technique, with four total current levels of 0C, 13C, 65C and 130C, was used to accelerate steel corrosion in concrete cylinder samples with w/c ratio of 0.4, 0.5, and 0.6, immersed in a 0.5M NaCl solution. A series of EIS measurements was performed to monitor concrete deterioration during the accelerated corrosion test in this study. Some critical parameters of the equivalent circuit were obtained through the EIS analysis. It was observed that the charge transfer resistance(Rc) dropped sharply as the impressed current increased from 0C to 13C, indicating a value of approximately 10kΩcm2. However, the sensitivity of Rc significantly decreased when the impressed current was further increased from 13C to 130C after corrosion of steel had been initiated. Meanwhile, the double-layer capacitance value(Cdl) linearly increased from 50×10-6μF/cm2 to 250×10-6μF/cm2 as the impressed current in creased from 0C to 130C. The results in this study showed that monitoring Cdl is an effective measurement parameter for evaluating the progress of internal concrete damages(de-bonding between steel and concrete, micro-cracks, and surface-breaking cracks) induced by steel corrosion. The findings of this study provide a fundamental basis for developing an embedded sensor and signal interpretation method for monitoring concrete deterioration due to steel corrosion at various corrosion levels.

Evaluation of a Compact Dry Method for Enumerating Bacteria in Contaminated Foods (식품 오염 미생물 분석을 위한 컴팩트 드라이법 평가)

  • Soo-Jin Jung;Sangha Han;June Gu Kang;Min Su Song;Hyewon Song;Harim Lee;Jisu Yu;Kyung Ok Lee;Sang-Do Ha
    • Journal of Food Hygiene and Safety
    • /
    • v.39 no.4
    • /
    • pp.304-311
    • /
    • 2024
  • The present study aimed to compare the accuracy of the compact dry and culture plate methods for natural flora (yeasts/molds, coliforms, and total bacterial count) and artificial inoculum (Escherichia coli) in dosirak (meat-based), meal kits (seafood-based), and Doenjang (traditional food). Compact dry TC, EC, CF, and YMR were compared with culture plate methods using a suitable medium for each bacterium. The total bacterial count, coliforms, yeasts/molds, and E. coli were assessed with 3M Petrifilm (aerobic bacterial, coliform, yeast/mold, and E. coli count plates) using culture plate methods. Analysis of the recovery rates of target microorganisms in the three food samples showed that the compact dry method for total bacteria, coliforms, and E. coli exhibited recovery capabilities equivalent to those of the culture plate and Petrifilm methods, with no significant differences (P>0.05). Overall, compact dry TC, CF, and EC showed a good correlation between the methods used in this study, indicating rapid and convenient microbial enumeration by saving time and requiring less space.