• 제목/요약/키워드: equivalent series resistance

검색결과 92건 처리시간 0.026초

Gas 색연(絶綠) 개폐장치(開閉裝置)의 철공진(鐵共振) 제어대책(制御對策)에 관한 연구(硏究) (A Study on the Elimination of Temporary overvoltage Due to Ferroresonance at Gas Insulated Switchgear)

  • 김승규;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.216-221
    • /
    • 2000
  • This paper describes the analysis results on the PT ferroresonance at 154 kV GIS (gas Insulated substation by EMTP(Electro- magnetic Transient Program). We had simulated the PT ferroresonance between a potential transformer(PT) and an open circuit breaker's grading capacitance. The ferroresonance leads to very large power frequency overvoltages on PT bus and subsequent insulation failure. The large power can be supplied to the PT by the high voltage on the opened circuit due to the grading capacitance and equivalent capacitance of the buses during the ferroresonance. The damping circuit connected on the secondary winding were considered in the model. The actual countermeasure include a saturable inductor and a resistor series-mounted, but the 2 ohms of damping resistance was used in the computationl model.

  • PDF

Watkins-Johnson 컨버터의 동작특성 해석 (Operation Analysis of th Watkins-Johnson Converter)

  • 안태영
    • 전자공학회논문지S
    • /
    • 제34S권6호
    • /
    • pp.85-93
    • /
    • 1997
  • This paper analyzes the steady-state and dynamic characteristics of the watkings-johnson converter. the major contributions of this paper includ identification of the following characteristics unique to the watkins-johnson converter: (1) The output voltage of the converter is nearly constant at the continous conduction mode (CCM), and at discontinousou conduction mode (DCM) it decreses linerly as the output curretn increases. (2) The control-to-output transfer function is a second-order one with a left-half-plane (LHP) zero determined by the combination of the output capacitor and equivalent series resistor of the converter. This LHP zero signinificantly improves the stability of the converter. (3) The control-to-output transfer function reduces to a first-order one, as the converter moves from CCM to DCM. (4) The parastic resistance of the inductor does not cause any significant influence on poles and zeros of the transfer function.

  • PDF

PWM 스윗치 모델을 이용한 PV용 Boost Converter Modelling (Boost Converter Modeling of Photovoltaic System Using PWM Switch Model)

  • 김효진;이기옥;최주엽;정영석;유권종;권종덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.286-293
    • /
    • 2002
  • Photovoltaic systems normally use a maximum power point tracking (MPPT) technique to continuously deliver the highest possible power to the load when variations in the insolation and temperature occur. A simple method of tracking the maximum power points (MPPs) and forcing the boost converter system to operate close to these Points is presented through deriving small-signal model and transfer function of boost converter. This paper aims at modeling boost converter including equivalent series resistance of input reservoir capacitor by state-space-averaging method and PWM switch model. In the future, properly designed controller for compensation will be constructed in real system for maximum photovoltaic power tracking control.

  • PDF

인버터용 전해커패시터의 수명 추정 (Life Estimation of Electrolytic Capacitors for Inverters)

  • 이동춘;김형진
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권7호
    • /
    • pp.338-346
    • /
    • 2001
  • In this paper, dc link currents for the three-phase diode rectifiers and PWM inverters are analyzed and an algorithm of estimating the life of dc link electrolytic capacitors using the analyzed ripple current is presented. Since the capacitor life is dependent on the operating temperature, the power dissipation in capacitors should be calculated. For this, the ESR(equivalent series resistance) model of the capacitor is derived and ripple currents through the capacitor are analyzed. Relating the power dissipation and the heat transfer equation, the internal operating temperature is calculated. Then, the capacitor life can be predicted by using Arrhenius's equation. An example for applications is given for the practical system.

  • PDF

154 kV GIS의 PT 철공진 소손사례와 원인규명 (A analysis result on the PT ferroresonance at 154 kV GIS substation)

  • 우정욱;심응보;김승규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2076-2079
    • /
    • 1999
  • This paper describes the analysis results on the PT ferroresonance at 154 kV GIS (gas Insulated substation by EMTP (Electro-magnetic Transient Program). We had simulated the PT ferroresonance between a potential transformer(PT) and an open circuit breaker's grading capacitance. The ferroresonance leads to very large power frequency overvoltages on PT bus and subsequent insulation failure. The large power can be supplied to the PT by the high voltage on the opened circuit due to the grading capacitance and equivalent capacitance of the buses during the ferroresonance. The damping circuit connected on the secondary winding were considered in the model. The actual countermeasure include a saturable inductor and a resistor series-mounted, but the 2 ohms of damping resistance was used in the computational model.

  • PDF

단상 하프-브리지 부스트 컨버터에서 DC 전해 커패시터의 고장예측 모니터링 (Failure Prediction Monitoring of DC Electrolytic Capacitors in Half-bridge Boost Converter)

  • 서장수;손진근;전희종
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.345-350
    • /
    • 2014
  • DC electrolytic capacitor is widely used in the power converter including PWM inverter, switching power supply and PFC Boost converter system because of its large capacitance, small size and low cost. In this paper, basic characteristics of DC electrolytic capacitor vs. frequency is presented and the real-time estimation scheme of ESR and capacitance based on the bandpass filtering is adopted to the single phase boost converter of uninterruptible power supply to diagnose its split dc-link capacitors. The feasibility of this real-time failure prediction monitoring system is verified by the computer simulation of the 5[kW] singe phase PFC half-bridge boost converter.

낮은 직류 링크 커패시턴스를 갖는 승압형 PFC 정류기를 위한 Active Power Decoupling 회로 구현에 관한 연구 (A Study on Implementation of Active Power Decoupling Circuit for Boost Type PFC Rectifier with Low DC Link Capacitance)

  • 황덕환;이정용;조영훈;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.246-247
    • /
    • 2017
  • 단상 ac/dc, dc/ac 시스템의 경우, ac와 dc사이의 전력 불균형으로 인해 double line frequency ripple power가 발생한다. 이는 harmonic disturbance을 야기시킨다. 일반적으로 전력 리플을 줄이기 위하여 dc-link에 용량이 큰 전해 커패시터를 사용하는데, 용량이 큰 전해 커패시터는 높은 equivalent series resistance(ESR)을 가지며, 상대적으로 짧은 수명을 갖는 한계를 갖는다. 본 논문은 active power decoupling을 추가함으로써 전해 커패시터를 용량이 작은 필름 커패시터로 대체한 회로 구조를 제시한다. 그리고 dc-link 커패시터 선정방법, 설계한 제어기의 성능과 부하 변동에 따른 실험을 PSIM 시뮬레이션으로 확인하고 실험을 통해 검증한다.

  • PDF

단상 트랜스-Z-소스 AC-AC 컨버터 (Single-phase Trans-Z-Source AC-AC Converter)

  • 신현학;채준영;정민재
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.407-408
    • /
    • 2015
  • The existing (q)Z-source PWM AC-AC converters have limited voltage gain because of the equivalent series resistance in the Z-source inductor. In order to obtain higher voltage gain than (q)Z-source AC-AC converters, a coupled inductor (or transformer) based Z-source AC-AC converter is proposed in this paper. By increasing turns ratio of the coupled inductor more than 1, the proposed converter can obtain higher output voltage than (q)Z-source converters with the same duty ratio. A 120 W prototype AC-AC converter is built and tested to verify performances of the proposed converter.

  • PDF

3상 인버터 시스템에서 주파수 특성을 고려한 필름 콘덴서의 DC-link 적용 방법에 관한 연구 (The study on DC-link Film Capacitor in 3 Phase Inverter System for the Consideration of Frequency Response)

  • 박현수
    • 한국산학기술학회논문지
    • /
    • 제19권4호
    • /
    • pp.117-122
    • /
    • 2018
  • 대용량 3상 시스템 에어컨은 최근 들어 소비 전력 저감을 위해 인버터 회로를 포함하고 있다. 인버터 회로는 교류를 다이오드를 통해 정류하고 DC-link 전원부 콘덴서에 의해 평활된 직류를 사용한다. 이 때 평활에 사용되는 DC-link 전원부 콘덴서는 전압 리플, 전류 리플 조건을 만족하기 위해 전해 콘덴서가 일반적으로 사용된다. 콘덴서의 용량을 줄이게 되면 회로부의 크기 및 무게, 비용을 줄일 수 있게 된다. 본 논문에서는 최소점 추정 PPL(Phase Locked Loop) 위상 제어와 평균 전압 d축 전류제어 기법을 조합하여 입력 리플 전류를 약 90% 저감하는 알고리즘을 제안한다. 입력 리플 전류의 감소로 인해 DC-link 콘덴서의 전류 리플도 감소하므로 콘덴서의 용량을 줄일 수 있지만 전해 콘덴서의 경우 등가 직렬 저항(ESR : Equivalent Series Resistance)이 크기 때문에 발열로 인한 수명이 한계를 가진다. 본 논문에서는 전해 콘덴서 대신 DC-link 단에 전류 리플을 고려한 필름 콘덴서를 선정하는 방법을 제안한다. 필름 콘데서의 정전 용량 선정, 내압 선정, RMS(Root Mean Square) 전류 용량, RMS 전류 주파수 해석을 고려해 콘덴서의 용량을 선정할 경우 1680uF의 전해 콘덴서를 20uF로 용량을 낮추어 설계함으로써 전원부 콘덴서의 크기 및 무게, 비용을 줄였으며 전동기 구동을 통해 동작을 확인하였다.

Frequency Characteristics of Anodic Oxide Films: Effects of Anodization Valtage

  • Lee, Dong-Nyung;Yoon, Young-Ku
    • Nuclear Engineering and Technology
    • /
    • 제6권1호
    • /
    • pp.14-22
    • /
    • 1974
  • 아노다이징 전압이 탄탈양극산화피막의 주파수 특성에 미치는 영향을 다음 임피단스 식을 이용하여 분석하였다. (equation omitted) 여기서 $R_{f}$, $C_{f}$는 각각 양극산화피막의 등가직렬저항, 등가직련용량, 유전 손실이다. 파라데타 P, $\tau$$_{ο}$, $\tau$$_{\omega}$, Co는 다음과 같이 정의된다. P=(d-w)/w, $\tau$$_{ο}$=$textsc{k}$$\rho$$_{ο}$, $\tau$$_{\omega}$=$textsc{k}$$\rho$$_{\omega}$, $C_{ο}$=$textsc{k}$A/d 여기서 d는 양극산화피막의 두께, $\omega$는 화산층의 두께, $\rho$$_{ο}$는 금속과산화물의 계면에서의 산화물의 비저항, $\rho$$_{omega}$는 앙극산화피막의 진성영역에서의 비저항, A는 양극산화 피막의 면적이며, $textsc{k}$=0.0885$\times$$10^{-12}$ $\times$유전상수(in farad/cm). 등가직렬용량의 주파수에 따른 변화와 유전손실은 아노다이징전압이 증가함에 따라 감소하였다. 이 현상은 산화피막의 화산충의 두께가 아노다이징전압이 증가함에 따라 약간 증하는반면 선화피막 전체두께는 아노다이징전압에 비례하여 증가한다는 사실 때문이다. 실험측정치가 tan$\delta$$_{f}$=0.682$\Delta$ $C_{f}$ 관계식으로부터 부로 이탈하는것을 위의 임피단스식에 바탕을 두고 검토하였다. 여기서 $\Delta$ $C_{f}$는 0.1과 1KHZ 사이에서의 용량변화이다.이다.다.

  • PDF