• Title/Summary/Keyword: equivalent network

Search Result 473, Processing Time 0.024 seconds

Design of a Transverse Flux Linear Motor

  • Chang, Jung-Hwan;Kim, Ji-Won;Kang, Do-Hyun
    • Journal of Magnetics
    • /
    • v.16 no.1
    • /
    • pp.58-63
    • /
    • 2011
  • This paper presents design procedures of a transverse flux linear motor (TFLM). The minimum and maximum flux linkage was determined by the simplified equivalent magnetic circuit and estimated average magnetic flux density at the air gap region by considering the shape of applied magnetomotive force (MMF). With this information, the number of turns of each phase winding was calculated based on the amplitude of applied voltage and speed of a mover. The rated current, coil diameter, and winding area were obtained with the aid of an empirical formula for determining the required MMF. The usefulness of the proposed design method for TFLM is verified by the three-dimensional equivalent magnetic circuit network (EMCN) method and the experimental results of prototyped machine.

Electrical Parameter Extraction of High Performance Package Using PEEC Method

  • Pu, Bo;Lee, Jung-Sang;Nah, Wan-Soo
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.1
    • /
    • pp.62-69
    • /
    • 2011
  • This paper proposes a novel electrical characterization approach for a high-performance package system using an improved Partial Element Equivalent Circuit (PEEC). As the effect of interconnects becomes a pivotal factor for the performance of high-speed electronic systems, there is a great demand for an accurate equivalent model for interconnects. In particular, an equivalent model of interconnects is established in this paper for the Fine-Pitch Ball Grid Array (FBGA) package using the improved PEEC method. Based on the equivalent model, electrical characteristics are analyzed; furthermore, these are verified through the measurement results of a Vector Network Analyzer (VNA).

A Phase-Domain Equivalent Representation for Electromagnetic Transients Studies (전력계통 과도현상 해석을 위한 상영역에서의 등가축약 기법)

  • Jung, B.T.;Kim, S.H.;Heo, S.I.;Ahn, B.S.;Hong, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.731-733
    • /
    • 1996
  • In this paper, a new time-domain reduction method for unbalanced 3 phase power systems will be represented. The impulse response of the system is used to identify a discrete-time equivalent filter model. The model is formulated directly in the phase domain. Each phase has a self-mode equivalent model and two mutual-mode equivalent models. The equivalent model is determined by the transfer function identification technique based on the Prony analysis. The model is implemented in EMTDC and tested with an unbalanced 3 phase network. The result of test showed that the equivalent model is accurate.

  • PDF

High-Frequency Equivalent Circuit Model for Differential Mode Noise Analysis of DC-DC Buck Converter (DC-DC 벅 컨버터의 차동모드 노이즈 분석을 위한 고주파 등가회로 모델)

  • Shin, Juhyun;Kim, Woojung;Cha, Hanju
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.473-480
    • /
    • 2020
  • In this paper, we proposed a high frequency equivalent circuit considering parasitic impedance components for differential noise analysis on the input stage during DC-DC buck converter switching operation. Based on the proposed equivalent circuit model, we presented a method to measure parasitic impedance parameters included in DC bus plate, IGBT, and PCB track using the gain phase method of a network analyzer. In order to verify the validity of this model, a DC-DC prototype consisting of a buck converter, a signal analyzer, and a LISN device, and then resonance frequency was measured in the frequency range between 150 kHz and 30 MHz. The validity of the parasitic impedance measurement method and the proposed equivalent model is verified by deriving that the measured resonance frequency and the resonance frequency of the proposed high frequency equivalent model are the same.

Permanent Magnet Overhang Effect in Permanent Magnetic Actuator Using 3 Dimension Equivalent Magnetic Circuit network Method

  • Lim Seung-Bin;Kwon Ho;Kwon Sam-Young;Choi Seung-kil;Baek Soo-Hyun;Lee Ju
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.2
    • /
    • pp.123-128
    • /
    • 2005
  • This paper presents an analysis of the permanent magnet overhang effect for the permanent magnetic actuator. Generally, the overhang is often used to increase the force density in permanent magnet machineries. The overhang is particularly profitable in reducing the volume after increasing the force density per volume when using the overhang effect of the permanent magnet. Therefore, the 3D Equivalent Magnetic Circuit Network Method (3D EMCN) has been used in this paper. According to the plunger position, the flux distribution per overhang length and the holding force are quantitatively compared. Furthermore, an appropriate length of the overhang has been proposed. To confirm the accuracy of the analysis method, the results of 2D FEM and 3D FEM are compared for the basic model.

A Study on the Thermal Characteristics of 110kW-class IPMSM for Light Railway Transit using the 3-Dimensional Thermal Equivalent Network considering Heat Source by Iron Loss Density Distributions (철손밀도 분포에 의한 열원이 고려된 3차원 열등가회로망을 이용한 경량전철 구동용 110kW급 IPMSM의 열 특성 연구)

  • Park, Chan-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.1038-1044
    • /
    • 2013
  • A research on thermal analysis method is conducted for the characterization of heat generation during operation of Interior Permanent Magnet Synchronous Motor(IPMSM) for Light Railway Transits(LRT) in this paper. Efficient cooling of the heat generated in the IPMSM is important because the excessive heat generated from the winding, core and permanent magnet makes it harder for a long time continuous operation of IPMSM. Therefore, in order to analyze the heat generation characteristics of the 110kW-class IPMSM as advanced research for application the IPMSM to the cooling device, the heat transfer coefficients for each component of the 110 kW-class IPMSM were derived and the thermal equivalent network was configured to perform the thermal analysis in this study. Finally, the 110kW-class IPMSM prototype is made and a comparative verification between the test data and the thermal analysis results through its various performance tests are carried out.

S-Domain Frequency Dependent Network Equivalent for Electromagnetic Transient and Harmonic Assessment (전자기 과도현상 해석과 고조파 평가를 위한 S영역 주파수 의존 등가시스템 개발)

  • Wang, Y.P.;Chong, H.H.;Lee, J.T.;Han, H.H.;Kim, H.J.;Chong, D.I.;Kwak, N.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.143-144
    • /
    • 2006
  • The recent power systems are very complex and to model them completely is impractical for analysis of electromagnetic transient Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). In this paper a method for developing Frequency Dependent Network Equivalent (FDNE) using S-domain rational Function Fitting is presented and demonstrated. The FDNE is generated by Linearized Least Squares Fitting(LSF) of the frequency response of a S-domain formulation. This Three-port FDNE have been applied to the test AC power system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the Three-port FDNE developed under different condition. The study results have indicated the robustness and accuracy of Three-port FDNE for analisys of electromagnetic transient and harmonic assessment.

  • PDF

Z-Domain Frequency Dependent Network Equivalent for Electromagnetic Transient and Harmonic Assessment (전자기 과도현상 해석과 고조파 평가를 위한 Z영역 주파수 의존 등가시스템 개발)

  • Wang, Y.P.;Chong, H.H.;Kim, K.Y.;Lee, J.T.;Han, H.H.;An, B.C.;Jeon, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.145-146
    • /
    • 2006
  • The recent power systems are very complex and to model them completely is impractical for analysis of electromagnetic transient. Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). In this paper a method for developing Frequency Dependent Network Equivalent (FDNE) using Z-domain rational Function Fitting is presented and demonstrated. The FDNE is generated by Linearized Least Squares Fitting(LSF) of the frequency response of a Z-domain formulation. This Three-port FDNE have been applied to the test AC power system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the Three-port FDNE developed under different condition. The study results have indicated the robustness and accuracy of Three-port FDNE for analisys of electromagnetic transient and harmonic assessment.

  • PDF

Analysis of Receiving Responses for a Bistatic Ground-Penetrating Radar System by Using Equivalent Network Model (등가회로망 모델을 이용한 Bistatic 지하탐사 레이더 시스템의 수신응답 해석)

  • 현승엽
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.6
    • /
    • pp.404-404
    • /
    • 2000
  • The receiving responses of a bistatic GPR system are analyzed by using three-dimensional FDTD method and equivalent network model. The conventional delta-gap feed model may be inaccurate because of neglecting the impedance matching characteristics between the antenna and the transmission line. In this paper, the feed model is improved by considering the physical characteristics of the actual GPR. The actually received voltage is calculated by employing the equivalent network model in angular frequency-domain, which is composed by using the results of three-dimensional FDTD analysis for an actual bistatic GPR system. The validity of the presented model is assured by showing the convergence of the computed results to the measured data.

Analysis of Receiving Responses for a Bistatic Ground-Penetrating Radar System by Using Equivalent Network Model (등가회로망 모델을 이용한 Bistatic 지하탐사 레이더 시스템의 수신응답 해석)

  • Hyeon, Seung-Yeop;Kim, Sang-Uk;Kim, Se-Yun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.6
    • /
    • pp.44-53
    • /
    • 2000
  • The receiving responses of a bistatic GPR system are analyzed by using three-dimensional FDTD method and equivalent network model. The conventional delta-gap feed model may be inaccurate because of neglecting the impedance matching characteristics between the antenna and the transmission line. In this paper, the feed model is improved by considering the physical characteristics of the actual GPR. The actually received voltage is calculated by employing the equivalent network model in angular frequency-domain, which is composed by using the results of three-dimensional FDTD analysis for an actual bistatic GPR system. The validity of the presented model is assured by showing the convergence of the computed results to the measured data.

  • PDF