• 제목/요약/키워드: equivalent load method

검색결과 566건 처리시간 0.025초

Equivalent stiffness method for nonlinear analysis of stay cables

  • Xia, G.Y.;Cai, C.S.
    • Structural Engineering and Mechanics
    • /
    • 제39권5호
    • /
    • pp.661-667
    • /
    • 2011
  • In the famous equivalent elasticity modulus method proposed by Ernst for the geometrical nonlinear analysis of stay cables, the cable shape was assumed as a parabolic curve, and only a part of the gravity load normal to the chord was taken into account with the other part of gravity load parallel to the chord being ignored. Using the actual catenary curve and considering the entire gravity load of stay cables, the present study has derived the equivalent stiffness method to analyze the sag effect of stay cables in cable-stayed bridges. The derived equivalent stiffness can be degenerated into Ernst's equivalent elasticity modulus method with some approximations. Therefore, the Ernst's method is a special and approximate formulation of the present method. The derived equivalent stiffness provides a theoretical explanation for the famous Ernst's formula.

등가부하법에 따른 유도기 온도상승 시험시 발생 증분 손실 해석 (Analysis on the increasing loss in Temperature rise test of induction motor by equivalent load method)

  • 박정태;이정일;김근웅;권중록;권병훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1045-1046
    • /
    • 2007
  • As equivalent load method of induction motor, even without connecting load, for temperature rise test has been acknowledged economic and corrective method, the method has been widely used instead of the real load method, and also international standards IEC 61986 is published in 2002. ABB, an well-known and famous electric machinery maker in the world, has been already applying the equivalent load method since 2002. HHI has been using real load method and equivalent load method for temperature rise of induction motor, it is already known that the equivalent test results is higher as $1-5^{\circ}K$ than that of real load test. But, quantity analysis for the reason of the temperature rise is not satisfied sufficiently. So, in this paper, quality analysis and also quantity analysis was conducted.

  • PDF

Determination of equivalent blasting load considering millisecond delay effect

  • Song, Zhan-Ping;Li, Shi-Hao;Wang, Jun-Bao;Sun, Zhi-Yuan;Liu, Jing;Chang, Yu-Zhen
    • Geomechanics and Engineering
    • /
    • 제15권2호
    • /
    • pp.745-754
    • /
    • 2018
  • In the analysis of the effects of rock tunnel blasting vibration on adjacent existing buildings, the model of simplified equivalent load produces higher calculation result of vibration, due to the lack of consideration of the millisecond delay effect. This paper, based on the static force equivalence principle of blasting load, proposes a new determination method of equivalent load of blasting vibration. The proposed method, based on the elastic-static force equivalence principle of stress wave, equals the blasting loads of several single blastholes in the same section of millisecond blasting to the triangle blasting load curve of the exploded equivalent elastic boundary surface. According to the attenuation law of stress wave, the attenuated equivalent triangle blasting load curve of the equivalent elastic boundary is applied on the tunnel excavation contour surface, obtaining the final applied equivalent load. Taking the millisecond delay time of different sections into account, the time-history curve of equivalent load of the whole section applied on the tunnel excavation contour surface can be obtained. Based on Sailing Tunnel with small spacing on Sanmenxia-Xichuan Expressway, an analysis on the blasting vibration response of the later and early stages of the tunnel construction is carried out through numerical simulation using the proposed equivalent load model considering millisecond delay effect and the simplified equivalent triangle load curve model respectively. The analysis of the numerical results comparing with the field monitoring ones shows that the calculation results obtained from the proposed equivalent load model are closer to the measured ones and more feasible.

동하중을 받는 구조물의 등가정하중 기반 구조최적화 연구 (Structural Optimization based on Equivalent Static Load for Structure under Dynamic Load)

  • 김현기;김의영;조맹효
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.236-240
    • /
    • 2013
  • Due to difficulty of considering dynamic load in side of a computer resource and computing time, it is common that external load is assumed as ideal static load. However, structural analysis under static load cannot guarantee the safety of structural design. Recently, the systematic method to construct equivalent static load from the given dynamic load has been proposed. Previous study has calculated equivalent static load through the optimization procedure under displacement constraints. And previously reported works to distribute equivalent static load were based on ad hoc methods. However, it is appropriate to take into account the stress constraint for the safety design. Moreover, the improper selection of loading position may results in unreliable structural design. The present study proposes the methodology to optimize an equivalent static which distributed on the primary DOFs, DOFs of the constraint elements, DOF of an external load as positions. In conclusion, the reliability of proposed method is demonstrated through a global optimization.

  • PDF

변위에 기초한 동하중에서 변환된 등가정하중하에서의 구조최적설계 (Structural Optimization under Equivalent Static Loads Transformed from Dynamic Loads Based on Displacement)

  • 강병수;최우석;박경진
    • 대한기계학회논문집A
    • /
    • 제24권8호
    • /
    • pp.1949-1957
    • /
    • 2000
  • All the loads in the real world act dynamically on structures. Since dynamic loads are extremely difficult to handle in analysis and design, static loads are utilized with dynamic factors. The dyna mic factors are generally determined based on experiences. Therefore, the static loads can cause problems in precise analysis and design. An analytical method based on modal analysis has been proposed for the transformation of dynamic loads into equivalent static load sets. Equivalent static load sets are calculated to generate an identical displacement field in a structure with that from dynamic loads at a certain time. The process is derived and evaluated mathematically. The method is verified through numerical tests. Various characteristics are identified to match the dynamic and the static behaviors. For example, the opposite direction of a dynamic load should be considered due to the vibration response. A dynamic bad is transformed to multiple equivalent static loads according to the number of the critical times. The places of the equivalent static load can be different from those of the dynamic load. An optimization method is defined to use the equivalent static loads. The developed optimization process has the same effect as the dynamic optimization which uses the dynamic loads directly. Standard examples are solved and the results are discussed

등가하중법 관점에서 분석한 프리스트레싱 텐던의 직선이동 (Analysis of the Linear Transformation of Prestressing Tendon Using Equivalent toad Method)

  • 오병환;전세진
    • 콘크리트학회논문집
    • /
    • 제14권6호
    • /
    • pp.843-850
    • /
    • 2002
  • 프리스트레스트 콘크리트 부재의 해석이론에서 텐던의 직선이동(linear transformation)은 텐던 배치에 대한 해석을 간략화시켜주는 장점이 있어 빈번히 다루어지고 있다. 본 논문은 그동안 간과되기 쉬웠던 직선이동에 내재된 근사화 및 그 영향을 밝히는데 중점을 두고 있으며, 주로 등가하중법(equivalent load method)을 통하여 직선이동의 이론을 분석하였다. 텐던이 이동하더라도 똑같은 등가하중 시스템이 산출되는 것을 직선이동으로 볼 경우, 기존의 등가하중법 고유의 내재된 가정은 그러한 직선이동의 원리가 성립하도록 하고 있으며, 반면 근사화가 포함되지 않은 엄밀한 의미의 등가하중 시스템에서는 그러한 원리가 성립하고 있지 않다 또한, 자체평형의 성질로부터 유도된 등가하중법을 직선이동에 적용하는 방안을 모색하였으며, 기존의 결과와 약간 다른 등가하중 시스템을 산출하였다. 논의를 확장하여 격납구조물 벽체 원환텐던(circumferential tendon)의 편심배치 문제를 직선이동의 관점에서 분석하였다.

단상 유도전동기의 무부하손실을 고려한 등가회로 정수의 결정 (Determination of Parameters of Equivalent Circuit Taking No-Load Losses Into Account for Single-Phase Induction Motors)

  • 좌종근;김도진
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.358-363
    • /
    • 2010
  • This paper proposes a step-by-step method of determining the parameters of equivalent circuit which is considered the no load losses for the single phase induction motor which has the starting winding. This method is comprised of three steps, and the stator resistance which is measured by the method of voltage drop is treated as constant and the stator and the rotor leakage reactances are assumed to be the same in every step. The test results of no load and locked rotor test are used in the 1st and 2nd step, and the ratings of name plate of the motor are needed in the 3rd step. In the 1st step, the traditional equivalent circuit parameters are directly calculated by no load and locked rotor conditions. In the next step, five nonlinear simultaneous equations for five unknown parameters can be set up by no load and locked rotor equivalent circuits. These equations are solved by using the initial parameters obtained by the 1st step parameters. In the final step, three nonlinear simultaneous equations for rotor winding resistance, leakage reactance and no load losses component resistance can be set up by equivalent circuit under the rated operation. Three parameters are solved by using the 2nd step parameters. Thus, equivalent circuit parameters are gradually refined step by step. The validity of the proposed method is evaluated by comparing the computed values obtained by the equivalent circuit parameters with the experimental values of the load test.

강성등가하중을 이용한 등가정적 연쇄붕괴 해석 (Equivalent Static Analysis of Progressive Collapse Using Equivalent Load for Stiffness)

  • 황영철;김계중;김치경
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.375-380
    • /
    • 2007
  • The goal of this paper is to develop a rational static method which consider efficiently the dynamic effect of the gravity load following sudden removal of element. For this goal this paper introduce the equivalent load for element stiffness which is a preceding research result and will develop equivalent static analysis which will be able to predict the maximum behavior considering dynamic effect. Some examples are provided to verify it. Equivalent static analysis is compared with the analysis method which is recommended by the GSA2003 guidelines and the time-history analysis which is the most accurate for dynamic behavior.

  • PDF

Unified equivalent frame method for flat plate slab structures under combined gravity and lateral loads - Part 1: derivation

  • Kim, Kang Su;Choi, Seung-Ho;Ju, Hyunjin;Lee, Deuck Hang;Lee, Jae-Yeon;Shin, Myoungsu
    • Earthquakes and Structures
    • /
    • 제7권5호
    • /
    • pp.719-733
    • /
    • 2014
  • The equivalent frame method (EFM) is widely used for the design of two-way reinforced concrete slab structures, and current design codes of practice permit the application of the EFM in analyzing the flat plate slab structures under gravity and lateral loads. The EFM was, however, originally developed for the flat plate structures subjected to gravity load, which is not suitable for lateral loading case. Therefore, this study, the first part of series research paper, proposed the structural analysis method for the flat plate slab structures under the combined gravity and lateral loads, which is named as the unified equivalent frame method (UEFM). In the proposed method, some portion of rotation induced in the torsional member is distributed to the flexibility of the equivalent columns, and the remaining portion is contributed to that of the equivalent slabs. In the consecutive companion paper, the proposed UEFM is verified by comparing with test results of multi-span flat plate structures. Also, a simplified nonlinear push-over analysis method is proposed, and verified by comparing to test results.

Implication and Rational Application of Equivalent Load Method in Prestressed

  • Oh, Byung-Hwan;Jeon, Se-Jin
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.663-667
    • /
    • 2000
  • The equivalent load method has been widely used in the design and analysis of prestressed concrete structures. The purpose of this paper is to explore several important method of obtaining equivalent loads and to clarify the advantages and limitations of each method. The methods devised in this study include the use of curvature of tendon, characteristics of primary moment, self-equilibrium conditions, and linear segments approximation of tendon. It is shown that equivalent lading system is not uniquely determined in some cases and careful engineering judgement is required from the view point of accuracy and practical convenience.

  • PDF