Analysis on the increasing loss in Temperature rise test of induction motor by equivalent load method

등가부하법에 따른 유도기 온도상승 시험시 발생 증분 손실 해석

  • Park, J.T. (Hyundai heavy industries Co., Ltd) ;
  • Lee, J.I. (Hyundai heavy industries Co., Ltd) ;
  • Kim, K.O. (Hyundai heavy industries Co., Ltd) ;
  • Kwon, J.L. (Hyundai heavy industries Co., Ltd) ;
  • Kwon, B.H. (Hyundai heavy industries Co., Ltd)
  • 박정태 (현대중공업 기계전기 연구소) ;
  • 이정일 (현대중공업 기계전기 연구소) ;
  • 김근웅 (현대중공업 기계전기 연구소) ;
  • 권중록 (현대중공업 기계전기 연구소) ;
  • 권병훈 (현대중공업 전전시스템 사업본부)
  • Published : 2007.07.18

Abstract

As equivalent load method of induction motor, even without connecting load, for temperature rise test has been acknowledged economic and corrective method, the method has been widely used instead of the real load method, and also international standards IEC 61986 is published in 2002. ABB, an well-known and famous electric machinery maker in the world, has been already applying the equivalent load method since 2002. HHI has been using real load method and equivalent load method for temperature rise of induction motor, it is already known that the equivalent test results is higher as $1-5^{\circ}K$ than that of real load test. But, quantity analysis for the reason of the temperature rise is not satisfied sufficiently. So, in this paper, quality analysis and also quantity analysis was conducted.

Keywords