• Title/Summary/Keyword: equivalence testing

Search Result 35, Processing Time 0.024 seconds

A Modeling Study of Local Equivalence Ratio Fluctuation in Imperfectly Premixed Turbulent Flames

  • Moon, Hee-Jang
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.8
    • /
    • pp.1479-1489
    • /
    • 2004
  • The effect of fluctuation of Equivalence Ratio (ER) in a turbulent reactive field has been studied in order to check the global combustion characteristics induced by the local fluctuation. When the flow is premixed on a large scale, closer examination on a small scale reveals that local fluctuations of ER exist in an imperfectly premixed mixture, and that these fluctuations must be considered to correctly estimate the mean reaction rate. The fluctuation effect is analyzed with DNS by considering the joint PDF of reactive scalar and ER, followed by modeling study where an extension of stochastic mixing models accounting for the ER fluctuation is reviewed and tested. It was found that models prediction capability as well as its potential is in favor to this case accounting the local ER fluctuation. However, the effect of local fluctuation did not show any notable changes on the mean global characteristics of combustion when statistical independence between the reactive scalar and ER field is imposed, though it greatly influenced the joint PDF distribution. The importance of taking into account the statistical dependency between ER and combustible at the initial phase is demonstrated by testing the modeled reaction rate.

Recent developments in remote inspections of ship structures

  • Poggi, Laura;Gaggero, Tomaso;Gaiotti, Marco;Ravina, Enrico;Rizzo, Cesare Mario
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.881-891
    • /
    • 2020
  • In recent years robotics has become an important resource in engineering. Adoption of Robotics and Autonomous Systems (RAS) in activities related to ship inspections has obvious potential advantages, but also arises particular challenges, both from technical and legal viewpoints. The ROBINS project (ROBotics technology for INspection of Ships) is a collaborative project co-funded within the H2020 EU Research and Innovation programme call, aimed at filling the gap between current ship inspections approach and available robotic technology, both from technological and regulatory point of view. Main goal of the present work is to highlight how ship inspections are currently carried out by humans, how they could be improved using RAS, even if not completely autonomous for the time being, at least in selected operational scenarios and how the performances of RAS platforms can be tested to assess their effectiveness in carrying out surveys onboard. In such a framework, a testing facility aimed at assessing RAS' capabilities as well as providing suitable environment for their development has been built and it is still under development along with dedicated testing protocols, able to assess the equivalence between human and RAS inspection of ship and marine structures. The features of a testing facility where RAS can be tested and the testing protocols are presented, showing how technological and regulatory gaps are filled.

Equivalent three-phase synthetic making test for medium voltage circuit breaker of distribution system using DC power (직류전원을 이용한 배전급 차단기의 등가 3상 합성투입시험법)

  • Park, Byung-Rak;Jo, Man-Yong;Kim, Jin-Seok;Shin, Hee-Sang;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.105-113
    • /
    • 2011
  • The study about three-phase synthetic making test using DC power has been performed in order to increase the making test capacity on Vacuum Circuit Breaker. And, it made possible to solve the limitations that short-circuit testing facilities can not fulfill the testing requirements of VCB exceeding three-phase 36[kV] 31.5[kA]. By using DC power and high speed spark-gap switch, this method made the equivalence with the pre-arc that occurred during the making process under the fault condition of power system. As results, KERI(Korea Electrotechnology Research Institute) could have capacity to carry out type test for VCB under three-phase 52[kV] 40[kV], which satisfies the IEC Standard.

Confirming the Continued Representativeness of an Online/Telephone Panel Using Equivalence Testing

  • Cho, Sung Kyum;LoCascio, Sarah Prusoff;Kim, Sungjoong
    • Asian Journal for Public Opinion Research
    • /
    • v.9 no.2
    • /
    • pp.188-211
    • /
    • 2021
  • Decreasing response rates to traditional survey methods, like face-to-face and telephone interviews, have led survey practitioners around the world to seek new ways of conducting surveys in recent years." The COVID-19 pandemic exacerbated this problem because it made conducting face-to-face interviews even more difficult than before. For example, it made conducting face-to-face surveys infeasible in 2020 in South Korea, and so the Korean Academic Multimode Open Survey (KAMOS) was unable to conduct a planned face-to-face survey to recruit new panel members. The entire 8,514-member panel, established via two-stage probability-based sampling from 2016 to 2019, was invited to take three online/telephone surveys in 2020. Of these panel members, 1,352 responded to at least one survey in 2020. To test to what extent the panel remained representative of the adult South Korean population, we compared the two groups of panel members: those who responded to at least one survey in 2020 and those who did not. After weighting both groups on the basis of age, sex, and geographical area, we analyzed their responses to some of the questions that were asked during multiple rounds of the face-to-face panel-recruiting interviews. Using Cohen's d for survey items that could be analyzed numerically and Cramér's V for categorical items, we were able to conclude that the respondents to the 2020 surveys were equivalent to the non-respondents in terms of both demographics and in the answers they originally gave to substantive questions on a variety of topics related to social science or public opinion research, including questions about quality of life, societal issue, and politics (Cohen's d items <0.2, 95% CI; Cramér's V items <0.1, 95% CI). This analysis may provide a model for others who wish to test the continued representativeness of their panel or who would like to use a different survey mode or change some other aspect of their methodology and test whether it is equivalent to their former methodology. Our success in building a panel that retained its representativeness may be useful to those in other countries where face-to-face surveys had previously been the norm but are becoming increasingly difficult to conduct.

A Behavior Conformance Checker for Component Interfaces using UML State Machine Diagram (UML 상태기계 다이어그램을 이용한 컴포넌트 인터페이스의 행위 호환성 검증 도구)

  • Kim, Ho-Jun;Lee, Woo-Jin
    • The KIPS Transactions:PartD
    • /
    • v.16D no.1
    • /
    • pp.65-72
    • /
    • 2009
  • Component based development has increasingly become important in the software industry. However, in the current component based development approach with UML, the absence of behavioral description of components brings about a cost problem which causes semantic errors on the testing phase. Accordingly we cannot grasp the usage pattern of component by its provided interfaces which refer to an abstraction of software component. And we cannot guarantee the behavioral conformance of the provided and required interfaces of components. In order to solve these problems, we describe the behaviors of component interfaces by state machine diagram and guarantee their behavior conformance at the modeling phase. We also propose a method to guarantee the behavior conformance of component interfaces with concept of observation equivalence and invocation consistency. And we provide an analyzing tool which checks interface behavior conformance.

The Design and Implementation of Automata-based Testing Environments for Multi-thread Java Programs (Java 다중 스레드 프로그램을 위한 오토마타 기반 테스팅 환경의 설계 및 구현)

  • 서희석;정인상;김병만;권용래
    • Journal of KIISE:Software and Applications
    • /
    • v.29 no.12
    • /
    • pp.883-894
    • /
    • 2002
  • Classical deterministic testing controls the execution of concurrent programs based on the equivalence between specifications and programs. However, it is not directly applicable to a situation in which synchronization sequences, being valid but infeasible, are taken into account. To resolve this problem, we had proposed automata-based deterministic testing in our previous works, where a concurrent program is executed according to one of the sequences accepted by the automaton recognizing all sequences semantically equivalent to a given sequence. In this paper, we present the automata-based testing environment for Java multi-thread programs, and we design and implement "Deterministic Executor" in the testing environment. "Deterministic Executor" transforms a Java multi-thread program by applying automata-based deterministic testing, the transformed program presents testing results. "Deterministic Executor" uses "Automata Generator", which generates an equivalent automaton of a test sequence, and "Replay Controller", which controls the execution of programs according to the sequence accepted by the automaton. By illustrating automata-based testing procedures with a gas station example, we show how the proposed approach does works in a Java multi-threaded program.roach does works in a Java multi-threaded program.

A Study on Carbon Monoxide and Other Gases During the Fire Test (A-class:1st Rating & B-class:1st Rating) (한국 A급, B급 1단위 화재 시험시 발생하는 일산화탄소 등의 정량적 연구)

  • Jeong, Incheon;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.44-56
    • /
    • 2013
  • This research is to identify how much toxic combustion gases are produced from Korea standardized real fire test (Class A&B) by using Room Corner Tester (RCT) and how much those gases are possibly dangerous to testing personnel by estimating the level of carboxyhemoglobin (% COHb). It is confirmed that testing personnel can be affected as more than 40% COHb from Class A 9th and 10th rating in respiration minute volume (RMV) 2 and from Class A 5th to Class A 10th rating in RMV 3 during the time for initial three minutes. Also, in the case of Class B real fire tests, although it is considered rather safe for the initial 1 minute, testing personnel can be affected as more than 20% COHb from Class B 16th to 20th rating in RMV 3 during total test time. Currently, the Korea standard is only focusing on the protection measures against the heat, but the it is neglecting the protection measures against toxic combustion gases. Therefore, according to this study, it is strongly recommended that testing personnel should wear a self-contained breathing apparatus, or the equivalence depending on the real fire test rating.

Statistical tests for biosimilarity based on relative distance between follow-on biologics for ordinal endpoints

  • Yoo, Myung Soo;Kim, Donguk
    • Communications for Statistical Applications and Methods
    • /
    • v.27 no.1
    • /
    • pp.1-14
    • /
    • 2020
  • Investigations of biosimilarity between reference drugs and test drugs required statistical tests; in addition, statistical tests to evaluate biosimilarity have been recently proposed. Ordinal outcome data has been observed in research; however, appropriate statistical tests to deal with ordinal endpoints for biosimilar have not yet been proposed. This paper extends existing design for ordinal endpoints. Using measure of nominal-ordinal association and relative distances between drugs are defined so that testing procedures are developed. Through simulation studies, we investigate type I error rate and power to show the performance of our suggested method. Furthermore, a comparison between the statistical tests and other designs is proviede to show significance of ordinal endpoints.

Problems and Improvements in the Quality Control of the Air Monitoring Network (대기오염측정망 정도관리의 문제점과 개선방향)

  • Kim, Duck-Sung;Park, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.29 no.8
    • /
    • pp.847-855
    • /
    • 2020
  • This study presented problems and improvements in the quality control of an air monitoring network, using Gyeongnam as an example. 1) The effective utilization rate of the air monitoring was 95%, which showed good management, but the maximum of 2% was indicated by zero or detection limit among measurement data. 2) In the equivalence evaluation of PM2.5, the slope and intercept satisfy the evaluation criteria; however, 1% of the PM2.5/PM10 ratios were outliers. 3) All air monitoring stations meet the quality control standards; however, the management status is added to the quality inspection, management system is unified and the related budget is expanded, and systematic commission management is required.

A Study on Optimization of the Weil-Dobkes Synthetic Short-Circuit Tests (Weil-Dobke 합성단락시험로의 최적화 연구)

  • 김맹현;고희석
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.6
    • /
    • pp.287-292
    • /
    • 2001
  • This paper deals with the configuration, operating principles, systematic calculation method of parameter and optimization method of test circuit for parallel current injection method, series voltage injection method and hybrid synthetic test method as the method for performance test of circuit breaker with extra high interrupting capacity. The test method depicted above is applied to short-circuit making and breaking test (operating sequence :Os CdOs, Od-CdOs) and out-of-phase tests(operating sequence :Os, CdOs) for performance test of the newly-developed 420kV, 50kA and 800kV 50kV puffer-type gas circuit-breaker according to IEC 60056 and IEC 60427. The testing results, evaluation of equivalence for test and analyzed results are also presented in this paper.

  • PDF