• Title/Summary/Keyword: equipment safety performance

Search Result 577, Processing Time 0.026 seconds

Analysis of Injuries in the Ghanaian Mining Industry and Priority Areas for Research

  • Stemn, Eric
    • Safety and Health at Work
    • /
    • v.10 no.2
    • /
    • pp.151-165
    • /
    • 2019
  • Background: Despite improvements in safety performance, the number and severity of mining-related injuries remain high and unacceptable, indicating that further reduction can be achieved. This study examines occupational accident statistics of the Ghanaian mining industry and identifies priority areas, warranting intervention measures and further investigations. Methods: A total of 202 fatal and nonfatal injury reports over a 10-year period were obtained from five mines and the Inspectorate Division of the Minerals Commission of Ghana, and they were analyzed. Results: Results of the analyses show that the involvement of mining equipment, the task being performed, the injury type, and the mechanism of injury remain as priorities. For instance, mining equipment was associated with 85% of all injuries and 90% of all fatalities, with mobile equipment, component/part, and hand tools being the leading equipment types. In addition, mechanics/repairmen, truck operators, and laborers were the most affected ones, and the most dangerous activities included maintenance, operating mobile equipment, and clean up/clearing. Conclusion: Results of this analysis will enable authorities of mines to develop targeted interventions to improve their safety performance. To improve the safety of the mines, further research and prevention efforts are recommended.

A Study on the Management Plan through Performance Maintenance Analysis of Explosion-proof Facilities (방폭설비 성능유지 실태분석을 통한 관리방안 연구)

  • Kwon, Yong Jun;Byeon, Junghwan
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.2
    • /
    • pp.8-16
    • /
    • 2020
  • In Article 311 of the Regulation on Occupational Safety and Health Standards requires the use of Korean Industrial Standards Act in accordance with the Industrial Standardization Act. However, the classification, inspection, maintenance, design, selection, and installation of explosion hazard locations for explosion and explosion prevention and internalization of 'safety' in the performance maintenance phase of electrical machinery and equipment There is no technical and institutional management plan for remodeling and alteration. Analysis of actual conditions and problems related to the installation, use, and maintenance of explosion-proof equipment, comparative analysis of domestic and international technical standards and systems, technical, institutional and administrative systems and systems related to installation, use, and maintenance of explosion-proof equipment, technical personnel and qualifications, etc. It is to propose legislation, system improvement, and technical standard establishment related to the maintenance of explosion-proof facility performance through improvement of the necessity and feasibility study for establishment of the legal status of the management site and management plan. As technical measures, KS standard revision (draft), KOSHA guide (draft) and explosion-proof facility performance maintenance manual were presented. In addition, the institutional management plan proposed the revised rule on occupational safety and health standards, the revised rule on the restriction of employment of hazardous work, and the manpower training program related to the maintenance of explosion-proof facilities and the qualification plan. Enhance safety at the installation, use, and maintenance stage of explosion-proof structured electrical machinery. It is expected to be used to classify explosion hazards, select related equipment, and to update and standardize standards related to installation, use and maintenance.

Influences of School Food Service Dietitians' Job Satisfaction and Perception of Barriers to HACCP Implementation on Food Sanitation/Safety Management Performance in Gyeongbuk Province (영양사의 직무만족도와 HACCP 시스템 적용 장애요인 인식정도가 위생.안전관리 수행에 미치는 영향 - 경북지역 학교급식소를 대상으로 -)

  • Lee, Gyeong-Eun;Lee, Hye-Sang
    • Journal of the Korean Dietetic Association
    • /
    • v.11 no.2
    • /
    • pp.179-189
    • /
    • 2005
  • The purpose of the study was to investigate the relationships between dietitian’s job satisfaction and perception of barriers to HACCP implementation and food safety/sanitation management performance in school food service. An e-mail survey was conducted to 144 dietitians in Gyeongbuk Province. A response rate was 57.6%(N=83) and data were analyzed using SPSS Windows(ver. 10.0). Dietitians were more satisfied with ‘supervision’ and 'co-workers' than 'pay' and 'promotion.' Dietitians perceived 'lack of teachers' support on student education' and ‘limited availability of facilities/equipment' as the biggest challenges in implementing a HACCP system. A total score of sanitation/safety management performance evaluated by school districts was 92 out of 100. By category, 'safety management' and 'personal hygiene' were rated the highest whereas 'facilities/equipment' and 'HACCP system' categories were rated the lowest. The food sanitation/safety management performance scores were not correlated to dietitian’s job satisfaction, but significantly correlated to dietitian’s perceptions of barriers to HACCP implementation. As dietitians perceived facilities/equipment-related barriers greater, the scores of 'facilities/equipment(p<.01),' 'production process(p<.05),' and 'total score(p<.01)' were significantly lower. The findings suggest that more investment on facilities/equipment are needed for food safety improvement and successful HACCP implementation in school food service. Proper facilities and equipment will make employees monitor CCPs and take corrective actions more easily.

  • PDF

Performance Evaluation of the Small Automatic Line Marking Equipment (소형 차선도색 자동화 장비의 성능 평가에 관한 연구)

  • Lee, Yongmun;Kim, Sangtae;Kim, Heungrae;Choi, Keechoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.677-684
    • /
    • 2016
  • In order to improve the nighttime visibility of the lane, the need for the development of the automated line marking equipment is on the rise. The purpose of this study is to suggest performance assessment methodology that can be assessed from various aspects such as productivity, safety and quality performance of line marking equipment and to comprehensively analyze the performance of hand-operated and automated equipment based on field test. The following shows the results. It suggested a methodology capable of analyzing the performance of the line marking equipment in terms of productivity, safety and quality. Automated equipment for line marking was analyzed that can be obtained productivity achievement rate of 156.3% as compared with hand-operated equipment. On the basis of the expert advise and literature review, we derived twelve safety factors and ten quality factors of unit work in line marking. By utilizing the AHP technique, we estimated the importance of safety and quality factors. Automated equipment for line marking was analyzed to have been able to expect safety improvement rate of 49.8% and quality improvement rate of 47.2%. It is expected that the performance assessment methodology suggested in this study will be useful in analyzing objective and quantitative validity and expected effectiveness of the line marking equipment.

Improvement of Performance based wooden building National Fire Safety Codes (성능에 기반을 둔 목조건축물 화재안전기준 개선방안)

  • Oh, Taek-Hum;Park, Chan-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.2
    • /
    • pp.83-92
    • /
    • 2016
  • Because National Fire Safety Codes is mixed performance criteria and specification, and it defines the fire extinguish equipment type and standards that need to be installed in a building as one method. Therefore, to fully reflect the fire risk characteristics of the building, such as the wooden building there is a limit. In this study, suggested to the performance criteria drawn methodologies through fire load of wooden buildings studies, theory on performance and performance analysis to fire extinguish equipment of the wooden buildings is installed according to current fire safety codes.

Performance and related factors of radiation safety management in dental hygienists (치과위생사의 방사선 안전관리 수행도 관련 요인)

  • Jeong, Jong-Yun;Han, Mi Ah;Park, Jong;Ryu, So Yeon
    • Journal of Korean society of Dental Hygiene
    • /
    • v.16 no.2
    • /
    • pp.215-224
    • /
    • 2016
  • Objectives: The purpose of the study was to investigate the related factors of performance of radiation safety management in dental hygienists. Methods: A self-reported questionnaire was completed by 183 dental hygienists using dental radiography in 110 dental clinics in G area by convenience sampling methods. The questionnaire consisted of general characteristics of the subjects, radiation-related characteristics, and performance and management of radiation safety. Results: Performance score of radiation safety management was $35.71{\pm}12.49$ in dental hygienists. The performance score of radiation safety management were associated with sex, numbers of dental hygienists, the average numbers of admitted patients per day, the total clinical experience, existence of manual for radiation safety management and perceived need for education of radiation safety management. Conclusions: The performance score was relatively low. The performance score was associated with radiation safety manual and safety equipment. The preparation of radiation protective environment and equipment will improve the performance of radiation safety management in dental hygienists.

A study on improving the performance of special ambulances (특수구급차 성능 개선을 위한 조사 연구)

  • Yoon, Byoung-Gil;Yang, Hyun-Mo;Kim, Gyoung-Yong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.26 no.1
    • /
    • pp.87-99
    • /
    • 2022
  • Purpose: This study aimed to provide basic data for the improvement of the standards related to the performance improvement of the firefighting equipment standards for special ambulances. Methods: Among the domestic firefighting equipment standards, the special ambulance standard was compared with the NFPA 1917 standard for the United States automobile ambulance 2019 and European Union European standard EN 1789 medical vehicle and its equipment, a road ambulance. Results: Anti-skid performance based on indoor noise standards, performance standards for interior lights, seat belt warning device, child car seat fixing device, safety handle, auxiliary footrest, and flooring materials should be supplemented. Conclusion: It is necessary to strengthen the production and performance standards for improvement to a level corresponding to the national standards, such as the United States and European Union.

A study on Detecting the Safety helmet wearing using YOLOv5-S model and transfer learning

  • Kwak, NaeJoung;Kim, DongJu
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.1
    • /
    • pp.302-309
    • /
    • 2022
  • Occupational safety accidents are caused by various factors, and it is difficult to predict when and why they occur, and it is directly related to the lives of workers, so the interest in safety accidents is increasing every year. Therefore, in order to reduce safety accidents at industrial fields, workers are required to wear personal protective equipment. In this paper, we proposes a method to automatically check whether workers are wearing safety helmets among the protective equipment in the industrial field. It detects whether or not the helmet is worn using YOLOv5, a computer vision-based deep learning object detection algorithm. We transfer learning the s model among Yolov5 models with different learning rates and epochs, evaluate the performance, and select the optimal model. The selected model showed a performance of 0.959 mAP.

Seismic behavior of simplified electrical cabinet model considering cast-in-place anchor in uncracked and cracked concretes

  • Bub-Gyu Jeon;Sung-Wan Kim;Sung-Jin Chang;Dong-Uk Park;Hong-Pyo Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4252-4265
    • /
    • 2023
  • In the case of nuclear power plants near end of their design life, a reassessment of the performance of safetyrelated equipment may be necessary to determine whether to shut down or extend the operation of the power plant. Therefore, it is necessary to evaluate the level of performance decline due to degradation. Electrical cabinets, including MCC and switchgear, are representative safety-related equipment. Several studies have assessed the degradation and seismic performance of nuclear power plant equipment. Most of those researches are limited to individual components due to the size of safety-related equipment and test equipment. However, only a few studies assessed the degradation performance of electrical cabinets. The equipment of various nuclear power plants is anchored to concrete foundations, and crack in concrete foundations is one of the most representative of degradation that could be visually confirmed. However, it is difficult to find a study for analysis through testing the effect of cracks in concrete foundations on the response of electrical cabinet internal equipment fixed by anchors. In this study, using a simple cabinet model considering cast-in-place anchor in uncracked and cracked concretes, a tri-axial shaking table tests were performed and the seismic behavior were observed.

A Study on Performance Evaluation and Security Methods of u-IT Electrical Safety Integrated Management System's Module (u-IT 전기안전통합관리시스템의 모듈별 성능평가와 보안방법 연구)

  • Park, Dae-Woo;Kim, Eung-Sik;Choi, Choung-Moon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.6
    • /
    • pp.1447-1452
    • /
    • 2010
  • Ubiquitous society to build basic infrastructure in the power supply and power equipment safety is important. u-City in order to prevent the disaster of u-IT Power Equipment Performance Module and the security for the safety of the u-City is necessary. In this paper, the power unit of u-IT module, temperature sensor, humidity sensor, equipped with sensors arranged throughout the fire, and home distribution boards, Home Network Wall-Pad, Blocker, MPNP black boxes, arc detection, arc safety equipment, outlet of the modular performance evaluation methods and security methods will be studied. u-IT power devices and sensors to analyze the information conveyed by proactive risk and ensure safety, access control, authentication, security safeguards, such as u-IT integrated management system for electrical safety and strengthen the security, safety and security with a u-City will contribute to the construction and operation.