• 제목/요약/키워드: equipment combination

Search Result 308, Processing Time 0.027 seconds

Survey and Analysis of International Standards for Practical Apply to Guideline on Software Quality Assurance and Human-Centred Design for e-Navigation (e-Navigation 소프트웨어 품질 보증 및 인간중심설계 가이드라인의 실무 적용을 위한 국제표준 조사 및 분석)

  • Jung, Jieun;Lee, Seojeong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2015.10a
    • /
    • pp.9-10
    • /
    • 2015
  • e-navigation is a Strategy developed by the IMO. It aims to implement the strategy in 2018. To this end, e-navigation Software Quality Assurance and Human-Centred Design Guidelines has been developing for the implementation and development of e-Navigation. The IMO MSC approved this guideline as a MSC circular in June 2015. In this paper, international standards of software quality assurance and human-centred design has been surveyed and analyzed in terms of usability testing for the practical application of this guideline. The result is planning to be reflected in the practical application guidance for the development of e-navigation equipment hardware-software combination.

  • PDF

The Development of the Movable-housing Planning Concept in Housing-architectural history of 20th Century (20 세기 주거건축사에 나타난 이동식 주거개념의 발전과정에 관한 연구)

  • Kim, Mi-Kyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.2
    • /
    • pp.13-21
    • /
    • 2008
  • The purpose of this study is to analyze the development and characteristics of movable-housing planning concept. A document research method was used to analyze and classified the development of the movable-housing concept of 20th century. Through this study, the following conclusions have been reached; First, the origin of the movable-housing is from the prehistoric and traditional portable buildings, also due to the emergence of nomadic lifestyle using car traveling and mobile home in the 1920's. Second, the development of the movable-housing in 20th century was classified as follows; (1) In order to obtain the productivity and efficiency drawing from the industrialized-housing in the early of 1900s, movable furniture and flexibility was proposed. (2) American mobile home in 1920's, influenced by the development of car industry, was the most successful example of a factory-built building to be found in the world. (3) Dymaxion house and dome by R.B.Fuller, an aggregation of high-tech mechanical equipment, had a great impact on the development the concept of 'mobility' and influenced Archigram & Metabolist's movable capsule ideas in 1960's. (4) The lightweight materials such as plastic, duralumin and pneumatic structure were adopted for movable-housing in 1960's. Through this research, It is discovered that the stage of social development has close links with the developing aspects of movable-housing concepts. This study shows that the combination of three planning concepts such as flexible housing, mobile-housing and capsule will be more ideal in movable-housing planning rather than relying on just one type.

Application of Hybrid SNCR/SCR process for Improved N Ox Removals Efficiency of SNCR (SNCR의 N Ox 제거효율 향상을 위한 Hybrid SNCR/SCR 공정 응용)

  • 최상기;최성우
    • Journal of Environmental Science International
    • /
    • v.12 no.9
    • /
    • pp.997-1004
    • /
    • 2003
  • The objective of this research was to test whether, under controlled laboratory conditions, hybrid SNCR/SCR process improves N $O_{x}$ removal efficiency in comparison with the SNCR only. The hybrid process is a combination of a redesigned existing SNCR with a new downstream SCR. N $O_{x}$ reduction experiments using a hybrid SNCR/SCR process have been conducted in simple NO/N $H_3$/ $O_2$ gas mixtures. Total gas flow rate was kept constant 4 liter/min throughout the SNCR and SCR reactors, where initial N $O_{x}$ concentration was 500 ppm in the presence of 5% or 15% $O_2$. Commercial catalysts, $V_2$ $O_{5}$ -W $O_3$-S $O_4$/Ti $O_2$, were used for SCR N $O_{x}$ reduction. The residence time and space velocity were around 1.67 seconds and 2,400 $h^{-1}$ or 6000 $h^{-1}$ in SNCR and SCR reactors, respectively. N $O_{x}$ reduction of the hybrid system was always higher than could be achieved by SNCR alone at a given value of N $H_{3SLIP}$. Optimization of the hybrid system performance requires maximizing N $O_{x}$ removal in the SNCR process. An analysis based on the hybrid system performance in this lab-scale work indicates that a equipment with N $O_{xi}$ =500 ppm will achieve a total N $O_{x}$ removal of about 90 percent with N $H_{3SLIP}$ $\leq$ 5 ppm only if the SNCR N $O_{x}$ reduction is at least 60 percent. A hybrid SNCR/SCR process has shown about 26∼37% more N $O_{x}$ reduction than a SNCR unit process in which a lower temperature of 85$0^{\circ}C$ turned out to be more effective.be more effective.

A Study on the Development of Building Control and management System -Focusing on the Lighting Control and Monitoring system- (빌딩 제어 및 관리 시스템 개발에 관한 연구 -조명 제어 관리 시스템 구축을 중심으로-)

  • Cho, Sung-O
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.4
    • /
    • pp.110-118
    • /
    • 2007
  • Technology has been viewed at various stages of civilization as leading to future progress. The building, its services systems and management of the work process all contribute to the well-being of people within an organization. Productivity relies on there being a general sense of high morale and satisfaction with the workplace. Now buildings are considered as providing a milieu for human creativity. Flexibility, adaptability, service integration and high standards of finishes offer an intelligence threshold. Building Automation System(BAS) - controlled lighting systems may offer incremental energy saving. Conventional Lighting control systems often control equipment in a single room or over the limited area, because they are centralized control systems, which means that all the controlled circuits must be wired to a single control panel. The computers used by these systems are typically dedicated microprocess that perform only lighting control functions. By comparison, modern Building automation systems are distributed control system, which means that their computing hardware and software are distributed as a network that microprocessor-based control modules and standard PC. PLC(Programmable Logic controller) is extensible virtually without limits, so that all the lighting in a facility can be controlled by single, unified system - the same system that also can control and monitor the building's HVAC, security, and manufacturing processed, elevators, and more. A Building automation system can control light using schedules, manual controls, occupancy sensors, and photosensors, either singly or in combination. Building Lighting control and monitoring system will be for a energy saving and efficient building management system.

Development of 3,300V 1MVA Multilevel Inverter using Series H-Bridge Cell (3,300V 1MVA H-브릿지 멀티레벨 인버터 개발)

  • 박영민;김연달;이현원;이세현;서광덕
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.478-487
    • /
    • 2003
  • In this paper, a type and special feature of Multi-level inverter used in medium-voltage and high-capacity motor driver is introduced. Especially, a power quality and structural advantages of H-Bridge Multi-level inverter is described. It presented the specific structure of power circuit, design method, controller composition and PWM techniques of the cascaded H-Bridge Multi-level inverter which is developed. The feasibility of the developed product based on 3,300V lMVA 7-level H-bridge inverter was studied by experiments and we get conclusion that 1)generate of near-sinusoidal output voltage; 2)is low dv/dt at output voltage; 3)reduce the harmonic injection at input; Experiment demonstrate that it is very economical in productivity because of using the existing production technique and examination equipment, and has the reliability and a good maintenance due to the structure of Power Cell unit combination as well as low cost IGBT.

A Study on Production and Its Usefulness of AAPM TG18 Guiding Instrument for Diagnostic Monitor QC (영상의학 검사 판독용 모니터 정도관리 Guiding Instrument 제작과 유용성 고찰)

  • Son, Gi-Gyeong;Sung, Dong-Wook;Jeong, Jae-Ho;Kang, Hui-Doo;Ryu, Kyung-Nam
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.21-28
    • /
    • 2008
  • Diagnostic display monitor QA according to AAPM TG18 is usually performed by PACS administrator, product manager and reading doctor, and for acceptance testing and periodic quality control evaluation, a combination of visual and quantitative tests can be used, as outlined in sections 5 and 6 of 'assessment of display performance for medical imaging systems'. Although many display tests can be performed visually, a more objective and quantitative evaluation of display performance requires special test tools. The required instruments vary in their complexity and cost, depending on the context of the evaluation(research, acceptance testing, or quality control) and how thorough the evaluation needs to be. Objective and reliable assessment of many display characteristics can be performed with relatively inexpensive equipment, So, we made 'AAPM TG18 guiding instrument' to ues variable purpose of the evaluation of 'geometrical distortions(quantitative"', 'veiling glare(visual)' and 'sensor calibration'. The spatial measurements for the quantitative evaluation of geometric distortions, and the measurement of the veling-glare ring response function which provides information regarding the spatial extent of the luminance spread, can be performed using the TG18 guiding instrument can be used to sensor calibration to standardize the basic rate of 0% luminance when periodic calibration.

  • PDF

Electrochemical Characteristics of Carbon/Carbon Hybrid Capacitor and Li-ion Battery/Hybrid Capacitor Combination (Carbon계 Hybrid Capacitor의 전기 화학적 기술 및 Li-ion Battery의 혼성 동력원 특성)

  • Lee, Sun-Young;Kim, Ick-Jun;Moon, Seong-In
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.597-598
    • /
    • 2005
  • Recently, the performance of portable electric equipment can often improved by a Li-ion battery assisted by a supercapacitor. A supercapacitor can provide high power density as well as a low resistance in the hybrid system. In this study, we have prepared, as the pluse power souce, a commercially supplied Li-ion battery with a capacity of 700mAh and AC resistivity of $60m\Omega$ at 1kHz and nonaqeous asymmetric hybrid capacitor composed of an activated carbon cathode and MCMB anode, and have examined the electrochemical characteristics of hybrid capacitor and the pulse performances of parallel connected battery/hybrid capacitor source. The nonaqueous asymmetric hybrid capacitor, the stacks of 10 pairs of the cathode, the porous separator and the anode electrode were housed in Al-laminated film cell. The hybrid capacitor, which was charged and discharged at a constant current at $0.25mA/cm^2$ between 3 and 4.3V, has exhibited the capacitance of 100F. And the equivalent series resistance was $32m\Omega$ at 1kHz. By combining a Li-ion battery and a hybrid capacitor, the pulse performance of battery can be improved 23% in run time under a pulse discharge of 7C-rate.

  • PDF

A Study on the Life Characteristic of an Automotive Water-pump Bearing Using the Accelerated Test Method (가속시험법을 활용한 자동차용 워터펌프 베어링의 수명특성에 관한 연구)

  • Yang, Hui Sun;Shin, Jung Hun;Park, Jong Won;Sung, Baek Ju
    • Tribology and Lubricants
    • /
    • v.31 no.2
    • /
    • pp.35-41
    • /
    • 2015
  • A water-pump located in the cooling area of a car circulates cooling water. A particular bearing element, known as a water-pump bearing, installed in the rotating part carries the entire load. The failure of this water-pump bearing has a direct impact on the failure of the automobile engine, and so securing its reliability is crucial. Several researchers have examined the design principles of the water-pump bearing, but there are no reports on the life characteristic of the bearing yet. Herein, we report the construction of test equipment to reproduce the spalling of the roller contact, which is the main failure mode of the chosen water-pump bearing. We chose the radial load as an accelerated stress factor and validated the failure mode by monitoring the surface defects. We conducted the accelerated life test after determining the accelerated stress level through a combination of finite element analysis and a preliminary test. In the life tests, we used an accelerometer to perform failure diagnosis. In the last stage of this study, we present a statistical reliability analysis. Thus, we fully estimated the shape parameter of the water-pump bearing, accelerating level on the load , and the lifetime (MTTF and B10 life) under real use conditions, and finally proposed an interval estimation value considering the uncertainty of the estimated value.

An Experimental Study on the Application of Horizontal Barrier and In-Rack Sprinklers to Prevent Vertical Spread of Rack-type Warehouse Fires (랙크식 창고 화재의 수직 확산 방지를 위한 수평차단막과 In-Rack 스프링클러 적용에 관한 실험연구)

  • Park, Moon-Woo;Hong, Sung-Ho;Choi, Ki-Ok;Choi, Don-Mook;Kim, Soo-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.15-21
    • /
    • 2019
  • A rack-type warehouse has the advantage of storing a large amount in a small area by loading goods vertically. But in terms of fire risk, the fire load is very high, which can cause massive damage in the event of a fire. In the United States, research has been actively conducted to minimize the spread of vertical fires, and relevant standards have been established and operated. In Korea, research and related standards are insufficient to prevent the vertical spread of rack-type warehouse fires. In this study, an experimental study was conducted to prevent the vertical spread of a rack-type warehouse fire using a horizontal barrier and in-rack sprinklers. As a result of the test, the horizontal barrier considering the continuous flame prevented the vertical spread of the flame for a certain time. However, the horizontal barrier with continuous flame did not show the effect of preventing continuous flame. The combination of the horizontal barrier and the in-rack sprinkler prevented the vertical spread of fire effectively. In addition, the heat collecting effect through the horizontal barrier was shown and helped the early operation of the in-rack sprinklers.

Preliminary Application of Molecular Monitoring of the Pacific Herring (Clupea pallasii) Based on Real-time PCR Assay Utilization on Environmental Water Samples

  • Kim, Keun-Yong;Heo, Jung Soo;Moon, Seong Yong;Kim, Keun-Sik;Choi, Jung-Hwa;Yoo, Joon-Taek
    • Korean Journal of Ecology and Environment
    • /
    • v.54 no.3
    • /
    • pp.209-220
    • /
    • 2021
  • Pacific herring, Clupea pallasii, a keystone species with significant ecological and commercial importance, is declining globally throughout much of its range. While traditional fishing equipment methods remain limited, new sensitive and rapid detection methods should be developed to monitor fisheries resources. To monitor the presence and quantity of C. pallasii from environmental DNA (eDNA) extracted from seawater samples, a pair of primers and a TaqMan® probe specific to this fish based on mitochondrial cytochrome b (COB) sequences were designed for the real-time PCR (qPCR) assay. The combination of our molecular markers showed high specificity in the qPCR assay, which affirmed the success of presenting a positive signal only in the C. pallasii specimens. The markers also showed a high sensitivity for detecting C. pallasii genomic DNA in the range of 1 pg~100 ng rxn-1 and its DNA plasmid containing COB amplicon in the range of 1~100,000copies rxn-1, which produced linear standard calibration curves (r2=0.99). We performed a qPCR assay for environmental water samples obtained from 29 sampling stations in the southeastern coastal regions of South Korea using molecular markers. The assay successfully detected the C. pallasii eDNA from 14 stations (48.2%), with the highest mean concentration in Jinhae Bay with a value of 76.09±18.39 pg L-1 (246.20±58.58 copies L-1). Our preliminary application of molecular monitoring of C. pallasii will provide essential information for efficient ecological control and management of this valuable fisheries resource.