• Title/Summary/Keyword: equipment cases

Search Result 690, Processing Time 0.036 seconds

Analysis of Personal Gait Characteristics According to Legs Imbalance Gait (하지 보행 불균형 상태에 따른 개인별 보행 특성 분석)

  • Cho, Woo-Hyeong;Kim, Yeon-Wook;Kwon, Jang-Woo;Lee, Sangmin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.5
    • /
    • pp.109-119
    • /
    • 2017
  • In the present study, to determine walking imbalance using the walking analysis method, where limitations in the existing walking analysis have been minimized, we propose a new walking analysis method that adopts the following: self-developed equipment to measure the angles of left-right hip joints and knee joints; a determination system using symmetry index (SI); and dynamic time warping (DTW) similarity analysis algorithm to analyze individual walking styles. Normal and imbalanced walking tests were conducted for 12 subjects without walking disorder. From the SI calculation to determine imbalanced walking, both the normal and imbalanced walking styles can be determined using the angle measurements of the left-right hip joints and knee joints. In the analysis of the individual walking styles, the similarities at the center of the lower back, left-right thighs, and dorsum of the feet of the 12 subjects in both normal and imbalanced walking cases were compared. From the similarity analysis of the measured values during the normal and imbalanced walking tests, I determined that the walking pattern does not maintain the same stance when the body parts move during walking.

Reinforcement Method of a Long Span Plastic Greenhouse using Tension-tie (인장타이를 이용한 광폭형 비닐하우스의 보강법)

  • Shin, Kyung-Jae;Shin, Dong-Hui;Lee, Swoo-Heon;Chae, Seoung-Hun
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • A long-span (more than 8m) plastic greenhouse is currently being used in farms due to its magnified benefits, such as the convenience of the farming equipment used, and the land usage efficiency. In this study, the reinforcing effects of the use of a pretension tie were shown. In a previous study, tests for a 6.5m single-span-type greenhouse announced by Rural Development Administration were carried out. The tests of symmetric and eccentrics now loading by the sun and wind were conducted for the 10.2m span with a ${\phi}48.1{\times}2.1$ section in this study, after which the load-deflection relationship was compared for the cases of reinforcement with a tie and without a tie. The results of the symmetric snow loading test showed that the strength increased by 68~93% in the case of the specimen with a tied arch. The failure mode of the specimen without a tie tended to be that with a sway failure mechanism, and that of the reinforcement specimens with a tie tended to be that with an arch buckling mechanism. The results of the eccentric snow loading test showed that the strength of the specimen with a tie increased by 10~20% compared to that of the specimen without a tie. For the failure mode of the latter, a combined failure mechanism was adapted, although the failure mode of the tied specimens tended to be that with an arch buckling mechanism.

Standard Configuration for Interface of the Traffic Information Service using DSRC (DSRC를 이용한 교통정보서비스 인터페이스 표준 구성)

  • Kim, Kyoung-Hwan;Cho, Yung-Sung;Bae, Myoung-Hwan;Kim, Sang-Heon;Lee, Kyeong-Im
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.5
    • /
    • pp.1-13
    • /
    • 2011
  • Recently, a number of OBU(On Board Unit) have being spreaded since ETCS(Electronic Toll Collection System)using DSRC(Dedicated Short Range Communication) was installed in the tollgate of the whole country. Many R&D and commercialization related to ITS service using DSRC and OBU mentioned above are ongoing such as traffic information collection and provision and a signal control, and public traffic information and management and so on. Especially, there are many researches conducted(conducting) on traffic information collection and provision using communication between OBU and RSE. However, Standards for both DSRC application and traffic collection and provision are not established clearly yet. So we would like to suggest a method of traffic information collection and provision without changing of standard related to DSRC. This method is to put the traffic messages into the existing Action primitive for ETC, which is described on "Technical criterion IV of basic traffic information exchange" which was notified by Ministry of Land, Transport and Maritime Affairs. Proposed standard application method is applied both to RSE and OBE. It is the same system which ETCS used in highway, currently. We confirmed the efficiency and performance of the system through conducting a variety of driving test using 4 vehicles in real road condition. Result of the real road test shows the effectiveness and validity of this method with about 97% communication success rate and based on studying the cases of 3% communication failure, we can analyse the expected problems in traffic information collection and provision using this method.

A Convergence Study on the Current Managerial Status and Policy of Regional Public Medical Centers : Focusing on Jeollabuk-do Province's cases (지방의료원의 운영 현황과 정책에 관한 융합적 연구 : 전라북도 사례를 중심으로)

  • Jeong, Ji-Na
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.9
    • /
    • pp.105-115
    • /
    • 2018
  • The study selected two regional public medical centers(G, N) in Jeollabuk-do to recognize problems and provide solutions for regional medical centers. The medical centers were analyzed, focusing on availability of medical personnel, budget and management thereof, medical treatment performance, public project performance, and patient satisfaction. The results showed that the medical centers were understaffed with doctors compared to private hospitals or national university hospitals and suffering financial debt. The number of patient with medical benefit was increasing in the medical center G, whereas it was decreasing in the medical center N. Patient satisfaction survey showed that the medical center G was scoring similar to the national average, whereas the medical center N was scoring slightly less than the average. Policies needed for development and efficient management of Regional public medical centers are clarification of Regional medical centers identity, modernization of medical equipment and facilities, recruitment of competent medical personnels, specialization of hospitals and establishment of stronger referral system. The regional medical centers should secure financial supports for public service from regional and national governments, and establish revenues from funerary service, leasing service, and national projects participation.

A Study on Validation for Mapping of Gas Detectors at a BTX Plant (BTX 공정에서 Gas Detector Mapping 적정성 검토에 관한 연구)

  • Seo, Ji Hye;Han, Man Hyoeng;Kim, Il Kwon;Chon, Young Woo
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.168-178
    • /
    • 2017
  • In order to prevent major and chemical accidents, some of the plants which would like to install and operate hazard chemicals handling facilities must submit Off-site Consequence Analysis due to recent arisen leak accidents since 2015. A lot of chemical industrials choose gas detectors as mitigation equipment to early detect gas vapor. The way of placement of gas detectors has two methods; Code-based Design(CBD) and Performance-based Design. The CBD has principles for gas detectors to be installed with consideration for the place that is expected to accumulate gas, and the leak locations according to legal standards and technical guidelines, and has a possibility to be unable to detect by these rules to locate gas detectors by vapor density information. The PBD has two methods; a Geographic Method and Scenario based Method. The Scenario-based Method has been suggested to make up for the Geographic Coverage Method. This Scenario-based Method draw the best optimum placement of gas detectors by considering leak locations, leak speed information, leak directions and etc. However, the domestic placement guidelines just refers to the CBD. Therefore, this study is to compare existing placement location of gas detectors by the domestic CBD with placement locations, coverages and the number of gas detectors in accordance with the Scenario-based Method. Also this study has measures for early detecting interest of Vapor Cloud and suitable placement of gas detectors to prevent chemical accidents. The Phast software was selected to simulate vapor cloud dispersion to predict the consequence. There are two cases; an accident hole size of leak(8 mm) from API which is the highst accident hole size less than 24.5 mm, and a normal leak hole size from KOSHA Guide (1.8 mm). Detect3D was also selected to locate gas detectors efficiently and compare CBD results and PBD results. Currently, domestic methods of gas detectors do not consider any risk, but just depend on domestic code methods which lead to placement of gas detectors not to make personnels recognize tolerable or intolerable risks. The results of the Scenario-based Method, however, analyze the leak estimated range by simulating leak dispersion, and then it is able to tell tolerable risks. Thus it is considered that individuals will be able to place gas detectors reasonably by making objectives and roles flexibly according to situations in a specific plant.

A numerical study on heat transfer and pressure drop of plate heat exchanger using at seawater air conditioning with the variation of channel spaces (채널 간격 변화에 따른 해수냉난방용 판형 열교환기의 열전달과 압력강하에 대한 수치해석적 연구)

  • Kim, Hyeon-Ju;Lee, Ho-Saeng;Yoon, Jung-In;Son, Chang-Hyo;Jung, Young-Kwon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.704-709
    • /
    • 2014
  • Plate heat exchanger is being applied in the field of marine plants and chemical industry, such as OTEC and SWAC equipment. The study aims to interpret the heat transfer and pressure drop characteristics of plate heat exchangers to determine the geometric design parameters such as the channel space. In this study, heat transfer performance was numerically studied with respect to the variation of channel spaces. The results from numerical analysis indicated that the j factor was linearly decreased with the flowrate of seawater over every cases. As the flowrate of water increased with respect to channel spaces, the j factor decreased linearly. And the f factor decreased linearly with the increase of flowrate. When the channel space is 2.8~3.2 mm and 3.2~3.2 mm, respectively, the area goodness factor of plate heat exchanger showed the highest performance.

Robust Design for Showerhead Thermal Deformation

  • Gong, Dae-Wi;Kim, Ho-Jun;Lee, Seung-Mu;Won, Je-Hyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.150.1-150.1
    • /
    • 2014
  • Showerhead is used as a main part in the semiconductor equipment. The face plate flatness should remain constant and the cleaning performance must be gained to keep the uniformity level of etching or deposition in chemical vapor deposition process. High operating temperature or long period of thermal loading could lead the showerhead to be deformed thermally. In some case, the thermal deformation appears very sensitive to showerhead performance. This paper describes the methods for robust design using computational fluid dynamics. To reveal the influence of the post distribution on flow pattern in the showerhead cavity, numerical simulation was performed for several post distributions. The flow structure appears similar to an impinging flow near a centered baffle in showerhead cavity. We took the structure as an index to estimate diffusion path. A robust design to reduce the thermal deformation of showerhead can be achieved using post number increase without ill effect on flow. To prevent the showerhead deformation by heat loading, its face plate thickness was determined additionally using numerical simulation. The face plate has thousands of impinging holes. The design key is to keep pressure drop distribution on the showerhead face plate with the holes. This study reads the methodology to apply to a showerhead hole design. A Hagen-Poiseuille equation gives the pressure drop in a fluid flowing through such hole. The assumptions of the equation are the fluid is viscous-incompressible and the flow is laminar fully developed in a through hole. An equation can be expressed with radius R and length L related to the volume flow rate Q from the Hagen-Poiseuille equation, $Q={\pi}R4{\Delta}p/8{\mu}L$, where ${\mu}$ is the viscosity and ${\Delta}p$ is the pressure drop. In present case, each hole has steps at both the inlet and the outlet, and the fluid appears compressible. So we simplify the equation as $Q=C(R,L){\Delta}p$. A series of performance curves for a through hole with geometric parameters were obtained using two-dimensional numerical simulation. We obtained a relation between the hole diameter and hole length from the test cases to determine hole diameter at fixed hole length. A numerical simulation has been performed as a tool for enhancing showerhead robust design from flow structure. Geometric parameters for the design were post distribution and face plate thickness. The reinforced showerhead has been installed and its effective deposition profile is being shown in factory.

  • PDF

A study on the strategy of entering into the global value chain for defense SMEs (방산 중소기업의 글로벌 부품공급망 진입전략 연구)

  • Won, Jun-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.301-309
    • /
    • 2020
  • Defense exports have overgrown in a short period, and items have been diversified with advanced high-end equipment, but exports have been stagnant due to the global economic recession and fierce competition. Weapons importers in the global market are diversified, volatility is higher, and global defense companies are also expanding their global value chain (GVC) By participating in the GVC of a global defense company, the defense SME can grow into a competitive company with specialized technology, rather than participating as a partner of a domestic system company. It is time to prepare an export promotion support plan. In this study, we selected five global companies with high value for the implementation of offset and general considerations on domestic SMEs' entry into the international parts supply chain and related cases, and investigated GVC entry requirements, the current status of cooperation partners, and the perceptions of GVC entry, through local surveys in Korea and overseas. Also, by considering the export target comprehensively, GVC stage, and the level of export competitiveness of domestic SMEs, strategies for promoting GVC participation of defense SMEs and improvements in government policies were derived and presented.

An Assessment of Environmental Characteristics Associated with the Level of Endotoxin Concentration in Hospital Lobbies (일부 종합 병원 로비의 공기 중 엔도톡신 농도에 미치는 환경 요인 평가)

  • Lee, Kyeong-Min;Yeom, Jeongkwan;Lee, Wonjae;Ryu, Seung-Hun;Park, Dongjin;Park, Dong-Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.3
    • /
    • pp.310-320
    • /
    • 2014
  • Backgrounds: Endotoxin, which found in the outer membrane of the gram-negative bacteria cell wall, makes up almost all of the lipopolysaccharide(LPS). When people are exposed to endotoxin,it can result in diverse health effects such as an airway irritation and inflammation, fever, malaise, bronchitis, allergic asthma, toxic pneumonitis, hypersensitivity lung disease. Cases among the elderly, children or pregnant can occur more frequently than a healthy adult if they are repeatedly exposed to the existing endotoxin. Therefore, we investigated and assessed the environmental characteristics associated with the airborne endotoxin concentration level in six hospital lobbies. Method: Endotoxin from indoor air in six hospital lobbies was measured by an area sampling method and analyzed according to American Society for Testing and Materials International(ASTM international) E2144-01. Total suspended particulate(TSP), carbon dioxide($CO_2$), temperature and humidity were also measured by using direct reading measurements or airborne sampling equipment at the same time. Environmental characteristics were appropriately divided into two or three groups for a statistics analysis. One-way analysis variable(one-way ANOVA) was used to examine a difference of the endotoxin concentration, depending on the environmental characteristics. In addition, only variables with p-value(p<0.25) were eventually designed to the best model by using multiple regression analysis. Results: The correlation analysis result indicated that TSP(p=0.003) and $CO_2$(p<0.0001) levels were significantly associated with endotoxin concentration levels. In contrast, temperature(p<0.068) and humidity(p<0.365) were not associated with endotoxin concentration. Levels of endotoxin concentration were statistically different among the environmental characteristics of Service time(p=0.01), Establishment of hospital(p<0.001), Scale of hospital(p=0.01), Day average people using hospital(p=0.03), Cleaning time of lobby(p=0.05), Season(p<0.001), and Cleaning of ventilation system(p<0.001) according to ANOVA. Finally, the best model(Adjusted R-square=72%) that we designed through a multiple regression test included environmental characteristics related to Service time, Area of lobby, Season, Cleaning of ventilation system, and Temperature. Conclusions: According to this study, our result showed a normal level of endotoxin concentration in the hospital lobbies and found environmental management methods to reduce the level of endotoxin concentration to a minimum. Consequently, this study recognized to be requirement for the management of ventilation systems and an indoor temperature in order to reduce the level of endotoxin concentration in the hospital lobbies.

A Basic Study for Securing the Business Continuity of Local Governments in the Event of Earthquake and Tsunami (지진 및 지진해일 발생 시 지방자치단체의 업무연속성 확보를 위한 기초 연구)

  • Shin, Hojoon;Koo, Wonhoi;Baek, Minho
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.2
    • /
    • pp.227-234
    • /
    • 2015
  • In this study, the theoretical review was carried out on the concepts regarding the continuity of operation plan and business continuity management plan, international standard ISO22301 and common required functions for disaster response, and the business continuity guideline of local governments in Japan and establishment cases were analyzed to draw matters to be reflected for establishing the business continuity plan of local governments according to the occurrence of earthquake and tsunami. In conclusion, the standard guideline of central government should be prepared for establishing the business continuity plan of local governments and the foundation to establish the plan smoothly based on such guideline should be provided. Also, the business continuity plan should be prepared based on the previous established safety management plans by reflecting the regional characteristics of local governments. And, in order to establish the business continuity plan that fits the region, proper investigations can be carried out to examine the characteristics of each organizations, resources, facilities and environments. Lastly, detailed scenario on the scale of earthquake and tsunami occurrence and damages is prepared to establish the business continuity plan of local governments and conditions for prompt countermeasures according to the scale.