• Title/Summary/Keyword: environmental instrumentation

Search Result 292, Processing Time 0.021 seconds

A Study on the Development of Soil-based PTMs for Analysis of BTEX (BTEX 분석용 토양 숙련도 표준시료(PTMs) 개발에 관한 연구)

  • Lee, Minhyo;Lee, Guntaek;Lee, Bupyoel;Lee, Wonseok;Kim, Gumhee;Hong, Sukyoung
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.5
    • /
    • pp.15-25
    • /
    • 2013
  • In this study, two kinds of soil-based proficiency testing materials (PTMs), NICE-012L and NICE-012R were prepared and certified for Benzen, Toluene, Etylbenzene and Xylene with evaluation of uncertainties. In order to analyse BTEX (Benzen Toluene Etylbenzene Xylene) for the candidate materials, GC/MS was used after pretreatment according to methods of soil analysis by Ministry of Environment. For the homogeneity test among bottles in terms of candidate materials, ISO 13528 and IUPAC Protocol were used and according to the result, both candidate materials showed sufficient homogeneity. Also, the stability test over the candidate materials was accessed according to the ISO Guide 35 by classifying short-term and long-term stability and the result showed that both candidate materials showed decent stability. The reference values of the two candidate materials depending on BTEX components were derived from the average of the 11 samples that were used for verification of the samples' homogeneity. Uncertainty of measurement was combined by uchar that was caused by a characteristic value, $u_{bb}$ that was caused by between-bottle homogeneity, and $u_{stab}$ that was caused by stability, and then combined uncertainty ($u_{PTM}$) was multiplied to the coverage factor (k) derived from the effective degree of freedom from each factor that leads to expanded uncertainty (U) in about 95% of confidence level. The proficiency testing materials developed through this study were supplied to National Institute of Environmental Research (NIER) and utilized as an external proficiency testing materials for evaluating analysis capacity of soil agencies with specialty in terms of soil analysis approved by Minister of Environment.

An Environmental Management Protocol for the Mitigation of Contaminants Migration from Military Operational Ranges (오염물질 확산방지를 위한 운영중 군 사격장 환경관리방안에 대한 고찰)

  • Jung, Jae-Woong;Moon, Hee Sun;Nam, Kyoungphile
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.6
    • /
    • pp.8-18
    • /
    • 2015
  • Pollutants such as heavy metals and explosives originating from the military operational ranges can be migrated to adjacent surface water body or offsite soil, and can affect to local residents and aquatic ecosystem. Therefore, Korea Ministry of the National Defense has established various guidelines for environmental management including the installation of pollutant migration prevention facilities (PMPFs) and monitoring methodologies for heavy metals in the operational range soil and effluent and sediment of PMPFs. However, current guidelines neither address the explosive compounds such as 2, 4, 6-trinitrotoluene (TNT) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) nor suggest detailed environmental investigation protocol. This paper introduces the new “Environmental Management Manual for Military Firing Ranges”, which includes the environmental criteria for explosives as well as the detailed investigation protocol for the affected environmental media including soil, effluent and sediment of PMPFs.

Assessment for the Comparability between Korean Ministry of Environment Standard and ISO Standard for the Determination of Heavy Metals in Soil (토양 중금속 함량 측정에 대한 토양오염공정시험기준과 국제표준간의 적합성 평가)

  • Shin, Gun-Hwan;Lee, Goon-Teak;Lee, Won-Seok;Kim, Ji-In;Kim, Bo-Kyong;Park, Hyun-Jeong
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.3
    • /
    • pp.1-9
    • /
    • 2012
  • According to the agreement on WTO/TBT, we are under the situation to adopt international standard (ISO standard) as a national standard if it exists. However, in case of environmental area, it is a domestic legal obligation to use Korean environmental standard method(KESM) for analyzing various contaminants. Therefore it is necessary to assess the comparability between KEM and ISO standard prior to apply ISO standard to soil conservation law in Korea. The main purpose of this study is to assess the comparability of both methods for analyzing heavy metals in soil. We looked over various aspects like pre-treatment, calibration curve range, detection wavelength, soil organic matter content and so on. Apparently, the procedure of both methods is almost same. However in details, both methods are different in stationary time before aqua-regia extraction using reflux system, calibration curve range for Cu, Pb, Ni and measuring wavelength for Pb. According to the results of comparison test, the results were significantly different when the different calibration range was used. In case that all the extracts independent of methods were reanalyzed with the same calibration range of each method, both methods showed statistically same results. Other conditions like different stationary time, measuring wavelength of AAS and soil organic matter content did not have any influence on the analytical result. Therefore, we suggest to extend the calibration curve range to 0~8 mg/L which is used in KS I ISO standard(Korean standard related with environment which is translation version of ISO standard without any technical change). In case of $Cr^{6+}$, the results showed no significant differences between two methods even though the pretreatment, instrumentation and other analysis conditions were different. In addition to UV/Visble spectrometry of KESM for soil contamination, we suggest to adopt ion chromatography of ISO 15192(US EPA method 7199) for analyzing $Cr^{6+}$ with the consideration of laboratory work efficiency.

Survey of the Applications of NGS to Whole-Genome Sequencing and Expression Profiling

  • Lim, Jong-Sung;Choi, Beom-Soon;Lee, Jeong-Soo;Shin, Chan-Seok;Yang, Tae-Jin;Rhee, Jae-Sung;Lee, Jae-Seong;Choi, Ik-Young
    • Genomics & Informatics
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • Recently, the technologies of DNA sequence variation and gene expression profiling have been used widely as approaches in the expertise of genome biology and genetics. The application to genome study has been particularly developed with the introduction of the nextgeneration DNA sequencer (NGS) Roche/454 and Illumina/ Solexa systems, along with bioinformation analysis technologies of whole-genome $de$ $novo$ assembly, expression profiling, DNA variation discovery, and genotyping. Both massive whole-genome shotgun paired-end sequencing and mate paired-end sequencing data are important steps for constructing $de$ $novo$ assembly of novel genome sequencing data. It is necessary to have DNA sequence information from a multiplatform NGS with at least $2{\times}$ and $30{\times}$ depth sequence of genome coverage using Roche/454 and Illumina/Solexa, respectively, for effective an way of de novo assembly. Massive shortlength reading data from the Illumina/Solexa system is enough to discover DNA variation, resulting in reducing the cost of DNA sequencing. Whole-genome expression profile data are useful to approach genome system biology with quantification of expressed RNAs from a wholegenome transcriptome, depending on the tissue samples. The hybrid mRNA sequences from Rohce/454 and Illumina/Solexa are more powerful to find novel genes through $de$ $novo$ assembly in any whole-genome sequenced species. The $20{\times}$ and $50{\times}$ coverage of the estimated transcriptome sequences using Roche/454 and Illumina/Solexa, respectively, is effective to create novel expressed reference sequences. However, only an average $30{\times}$ coverage of a transcriptome with short read sequences of Illumina/Solexa is enough to check expression quantification, compared to the reference expressed sequence tag sequence.

Emission Rates of Biogenic Volatile Organic Compounds (BVOCs) from Various Tree Species in Korea (I) (국내 수종별 BVOCs 방출량 (1))

  • Chang, Hanna;Son, Jounga;Je, Sun Mi;Oh, Chang-Young;Cho, Minseok;Kim, Juwan;Kim, Jaehyeon;Choi, Won-Sil;Lee, Young-Kyu
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.4
    • /
    • pp.543-553
    • /
    • 2021
  • This research focused on the investigation of isoprene and terpene emissions from 30 major urban tree species. We conducted sampling using a specific dynamic enclosure system between August and September 2020. Seedlings less than three years old were enclosed in a chamber consisting of a 400 L transparent Tedlar bag. The air-flows from the chamber's outlet were sampled using Tenax-filled sorbent tubes in the presence of standard conditions (temperature: 30℃, PAR: 1,000 μmol/m2/sec). A thermal desorption GC/MS system was used to analyze 38 BVOC compounds (isoprene, monoterpene, sesquiterpene, oxygenated monoterpene, and sesquiterpene). Isoprene emitters included Phyllostachys bambusoides, Quercus serrata, Daphniphyllum macropodum, and Buxus Koreana. Monoterpene emitters included Pinus rigida, Acer pictum subsp. mono, Larix kaempfer, Magnolia denudata, Metasequoia glyptostroboides, Pinus koraiensis, Pinus densiflora, and Abies holophylla. The monoterpene emission profiles were dominated by α-pinene, myrcene, limonene, β-pinen, and sabinene, while caryophyllene and farnesene were the prominent sesquiterpenes. Predominant oxygenated monoterpene compounds were also discovered as pulegone, borneol, menthol, eucalyptol, and nerol, while caryophyllene oxide were the prominent oxygenated sesquiterpenes. Sesquiterpenes and oxygenated sesquiterpenes had relatively lower contributions for all species.

Emission Rates of Biogenic Volatile Organic Compounds from Various Tree Species in Korea (II): Major Species in Urban Forests (국내 수종별 BVOCs 방출량(II): 도시 숲 주요 수종)

  • Hanna, Chang;Jounga, Son;Juwan, Kim;Junhyuk, Kim;Yeongseong, Kim;Won-Sil, Choi;Young-Kyu, Lee
    • Journal of Korean Society of Forest Science
    • /
    • v.111 no.4
    • /
    • pp.490-501
    • /
    • 2022
  • In this study, the isoprene and terpene emissions from 32 major urban tree species were investigated. We conducted sampling using a dynamic enclosure system between June and July 2021. Seedlings aged < three years were enclosed in a chamber consisting of a 400 L transparent Tedlar bag. The air flow from the outlet of the chamber was sampled using Tenax-filled sorbent tubes under standard conditions (temperature: 30°C; PAR: 1,000 μmol/m2/sec). A thermal desorption gas chromatography/mass spectrometry system was used to analyze the following 38 biogenic volatile organic compounds: isoprene, monoterpenes, sesquiterpenes, oxygenated monoterpenes, and oxygenated sesquiterpenes. Isoprene emitters included Quercus mongolica, Salix koreensis, Robinia pseudoacacia, and Salix chaenomeloides. Monoterpene emitters included Pinus strobus, Cedrela sinensis, and Cercis chinensis. The monoterpene emission profiles were dominated by á-pinene, myrcene, camphene, and limonene. The predominant oxygenated monoterpene and oxygenated sesquiterpene were eucalyptol and caryophyllene oxide, respectively. For all species, the contributions of sesquiterpenes and oxygenated sesquiterpenes were relatively low.

Design and Qualification of FPGA-based Controller applying HPD Development Life-Cycle for Nuclear Instrumentation and Control System (HPD 개발수명주기를 적용한 원전 FPGA 기반 제어기의 설계와 검증)

  • Lee, Joon-Ku;Jeong, Kwang-Il;Park, Geun-Ok;Sohn, Kwang-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.6
    • /
    • pp.681-687
    • /
    • 2014
  • Nuclear industries have faced unfavorable circumstances such as an obsolescence of the instrumentation and control system, and therefore nuclear society is striving to resolve this issue fundamentally. IEC and IAEA judge that FPGA technology is a good replacement for Programmable Logic Controller (PLC) of Nuclear Instrumentation and Control System. FPGAs are currently highlighted as an alternative means for obsolete control systems. Because the main function inside an FPGA is initially developed as software, good software quality can impact the reliability of an FPGA-based controller. Therefore, it is necessary to establish a software development aspect strategy that enhances the reliability of an FPGA-based controller. In terms of software development, HDL-Programmed Device (HPD) Development Life Cycle is applied into FPGA-based Controller. The burn-in test and environmental(temperature) test should be performed in order to apply into nuclear instrumentation and control system. Therefore it is ensured that the developed FPGA-based controller are normally operated for 352 hours and 92 hours in test chamber of Korea Institute of Machinery and Materials (KIMM).

Environmental Fatigue Evaluation of Top-Mounted In-Core Instrumentation Nozzle (상부 탑재형 노내계측기 노즐의 환경피로평가)

  • Yoon, Hyo-Sub;Kim, Jong-Min;Maeng, Cheol-Soo;Kim, Gee-Seok;Kim, Hyun-Min
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.3
    • /
    • pp.245-252
    • /
    • 2016
  • The development of Top-Mounted In-Core Instrumentation(TM-ICI) is an ongoing project to reduce the risk due to severe accidents by inserting the instrumentation into a reactor closure head instead of a reactor bottom head. As part of this project, environmental fatigue analyses for TM-ICI nozzle have been performed using two methods of NUREG/CR-6909 and Code Case N-761. TM-ICI nozzle is subjected to transient loads for level A, level B and test conditions that should be evaluated for a fatigue analysis. It is found that a cumulative usage factor considering reactor coolant environment for TM-ICI nozzle is evaluated as less than 1, which is ASME Code allowable criteria of a fatigue analysis.

Effect of Differences between Korean Ministry of Environment Standard and ISO Standard on Determination of Petroleum Hydrocarbon Content in Soil (토양오염공정시험기준과 국제표준간의 분석방법 차이가 유류 정량에 미치는 영향)

  • Jung, In-Ho;Lee, Goon-Taek;Lee, Won-Seok;Kim, Yong-Hoon;Kim, Bo-Hyun;Kim, Ji-In;Kim, Bo-Kyong
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.4
    • /
    • pp.63-72
    • /
    • 2012
  • The main objective of this study is to assess the compatibility between Korean ministry of environment (KME) standard and ISO (KS I ISO) standard for the determination of BTEX and TPH content in soil. We carried out comparison analysis for both methods using CRM and matrix spiked samples. In case of GC-MS analysis for BTEX, we got statistically (significance level: 0.05) the same results from KME standard (ES 07600.1) and ISO standard (KS I ISO 15009). However, it showed statistically (significance level: 0.05) different results when TPH was analyzed by KME standard (ES 07552.1) and ISO standard (KS I ISO 16703). To clarify the reason why both methods produced different results for TPH content, we also did some additional experiments in terms of differences in extraction, clean-up and target hydrocarbon range. Extraction with polar and non-polar compounds mixed solvent (acetone+n-heptane) of KS I ISO 16703 showed higher extraction efficiency than with only non polar solvent (dichloromethane) extraction of ES 07552.1 by about 9%. While column type clean-up of KS I ISO 16703 showed the reduction in TPH content between before and after clean-up, batch type of clean-up of ES 07552.1 did not show any changes in TPH content through clean-up process. The target hydrocarbon range of ES 07552.1 and KS I ISO 16703 is $C_8{\sim}C_{40}$ and $C_{10}{\sim}C_{40}$, respectively. From this point of view, kerosene and JP-8 contaminated soil showed higher RPD (relative producibility deviation) values between results by both method than that of lubricant or diesel contaminated soil. The higher content of hydrocarbon ($C_8{\sim}C_{10}$) in kerosene and JP-8 played an important role in increasing RPD values in addition to the effects caused by different solvents and clean-up method. Consequently, it was concluded that both methods (ES 07552.1 and KS I ISO 16703) were not compatible.

A Review of Instrumentation System and Construction of Korea Highway Test Road (시험도로 건설과 계측시스템 구축)

  • 최준성;김도형;김성환
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.603-606
    • /
    • 2000
  • The cost needed for the construction and management of highways in the whole nation is rapidly growing so the research that can decrease the cost is required. However, most of the highway specs have simply converted from those of other countries, including USA. Therefore, some of our design and construction specs were not the optimum ones based on our own situation, requiring a research under the actual traffic and environment of our nation. The use of test road develops many aspects of highway engineering. Those are evaluation of construction materials, a general overview of korea pavement design and serviceability under the actual traffic and environmental condition of the nation. It is also economical and efficient compared to the trial construction of each item in spreaded form. A test road, 7.7km long with two lanes, is being constructed on the Inner Central Expressway. In this test road, 2.7km is planned for asphalt pavement and 3.4km is planned for concrete pavement. Three test bridges and five earth retaining structures will be included in the test road. Based on the master plan, the major performance was progressing such as detailed research modules of each area, preliminary research for the future research, sensor surveys for the behavior analyses of pavements and structures with installation methods and data acquisition systems, the foundation research of Integrated Instrumentation System and the Management Plan for automated measurement. Some area(structure research division, geotechnical research division) was designed the instrumentation plan because some instrument sensors must be installed during the construction of the test road. And then the instrumentation plan of each area was enforcing because a large majority of the instrument sensors must be installed after the construction of the test road. The field surveys with material property tests and pilot instrumentation test with sensor tests was also performing in accordance with the construction in the field.

  • PDF