• Title/Summary/Keyword: environmental VOCs

Search Result 655, Processing Time 0.024 seconds

The Effects of Wearing Protective Devices among Residents and Volunteers Participating in the Cleanup of the Hebei Spirit Oil Spill (허베이스피릿호 유류유출사고 방제작업 참여자의 보호장비착용 효과)

  • Lee, Seung-Min;Ha, Mi-Na;Kim, Eun-Jung;Jeong, Woo-Chul;Hur, Jong-Il;Park, Seok-Gun;Kwon, Ho-Jang;Hong, Yun-Chul;Ha, Eun-Hee;Lee, Jong-Seung;Chung, Bong-Chul;Lee, Jeong-Ae;Im, Ho-Sub;Choi, Ye-Yong;Cho, Yong-Min;Cheong, Hae-Kwan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.42 no.2
    • /
    • pp.89-95
    • /
    • 2009
  • Objectives : To assess the protective effects of wearing protective devices among the residents and volunteers who participated in the cleanup of the Hebei Spirit oil spill. Methods : A total of 288 residents and 724 volunteers were surveyed about symptoms, whether they were wearing protective devices and potential confounding variables. The questionnaires were administered from the second to the sixth week following the accident. Spot urine samples were collected and analyzed for metabolites of 4 volatile organic compounds(VOCs), 2 polycyclic aromatic hydrocarbons(PAHs), and 6 heavy metals. The association between the wearing of protective devices and various symptoms was assessed using a multiple logistic regression adjusted for confounding variables. A multiple generalized linear regression model adjusted for the covariates was used to test for a difference in least-square mean concentration of urinary biomarkers between residents who wore protective devices and those who did not. Results : Thirty nine to 98% of the residents and 62-98% of volunteers wore protective devices. Levels of fatigue and fever were higher among residents not wearing masks than among those who did wear masks(odds ratio 4.5; 95% confidence interval 1.23-19.86). Urinary mercury levels were found to be significantly higher among residents not wearing work clothes or boots(p<0.05). Conclusions : Because the survey was not performed during the initial high-exposure period, no significant difference was found in metabolite levels between people who wore protective devices and those who did not, except for mercury, whose biological half-life is more than 6 weeks.

Evaluation of Thermal Catalytic Decomposition of Chlorinated Hydrocarbons and Catalyst-Poison Effect by Sulfur Compound (염소계 탄화수소의 열촉매 분해와 황화합물에 의한 촉매독 영향 평가)

  • Jo, Wan-Kuen;Shin, Seung-Ho;Yang, Chang-Hee;Kim, Mo-Geun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.5
    • /
    • pp.577-583
    • /
    • 2007
  • To overcome certain disadvantages of past typical control techniques for toxic contaminants emitted from various industrial processes, the current study was conducted to establish a thermal catalytic system using mesh-type transition-metal platinum(Pt)/stainless steel(SS) catalyst and to evaluate catalytic thermal destruction of five chlorinated hydrocarbons[chlorobenzene(CHB), chloroform(CHF), perchloroethylene (PCE), 1,1,1-trichloroethane(TCEthane), trichloroethylene(TCE)]. In addition, this study evaluated the catalyst poison effect on the catalytic thermal destruction. Three operating parameters tested for the thermal catalyst system included the inlet concentrations, the incineration temperature, and the residence time in the catalyst system. The thermal decomposition efficiency decreased from the highest value of 100% to the lowest value of almost 0%(CHB) as the input concentration increased, depending upon the type of chlorinated compounds. The destruction efficiencies of the four target compounds, except for TCEthane, increased upto almost 100% as the reaction temperature increased, whereas the destruction efficiency for TCEthane did not significantly vary. For the target compounds except for TCEthane, the catalytic destruction efficiencies increased up to 30% to 97% as the residence time increased from 10 sec to 60 sec, but the increase of destruction efficiency for TCEthane stopped at the residence time of 30 sec, suggesting that long residence times are not always proper for thermal destruction of VOCs, when considering the destruction efficiency and operation costs of thermal catalytic system together. Conclusively, the current findings suggest that when applying the transition-metal catalyst for the better destruction of chlorinated hydrocarbons, VOC type should be considered, along with their inlet concentrations, and reaction temperature and residence time in catalytic system. Meanwhile, the addition of high methyl sulfide(1.8 ppm) caused a drop of 0 to 50% in the removal efficiencies of the target compounds, whereas the addition of low methyl sulfide (0.1 ppm), which is lower than the concentrations of sulfur compounds measured in typical industrial emissions, did not cause.

Stabilizing Soil Moisture and Indoor Air Quality Purification in a Wall-typed Botanical Biofiltration System Controlled by Humidifying Cycle (가습 주기에 따른 벽면형 식물바이오필터의 토양 수분 안정화 및 실내공기질 정화)

  • Lee, Chang Hee;Choi, Bom;Chun, Man Young
    • Horticultural Science & Technology
    • /
    • v.33 no.4
    • /
    • pp.605-617
    • /
    • 2015
  • The ultimate goal of this research is to develop a botanical biofiltration system that combines a green interior, biofiltering, and automatic irrigation to purify indoor air pollutants according to indoor space and the size of biofilter. This study was performed to compare the stability of air flow characteristics and removal efficiency (RE) of fine dust within a wall-typed (vertical) botanical biofilter depending on humidifying cycle and to investigate RE of volatile organic compounds (VOCs) by the biofilter. The biofilter used in this experiment was designed as an integral form of water metering pump, water tank, blower, humidifier, and multi-level planting space in order to be suitable for indoor space utilization. As a result, relative humidity, air temperature, and soil moisture content (SMC) within the biofilter showed stable values regardless of three different humidifying cycles operated by the metering pump. In particular, SMCs were consistently maintained in the range of 27.1-29.7% during all humidifying cycles; moreover, a humidifying cycle of operating for 15 min and pausing for 45 min showed the best horizontal linear regression (y = 0.0008x + 29.09) on SMC ($29.0{\pm}0.2%$) during 120 hour. REs for number of fine dust (PM10) and ultra-fine dust (PM2.5) particles passed through the biofilter were in the range of 82.7-89.7% and 65.4-73.0%, respectively. RE for weight of PM10 passed through the biofilter was in the range of 58.1-78.9%, depending on humidifying cycle. REs of xylene, ethyl benzene, total VOCs (TVOCs), and toluene passed through the biofilter were in the range of 71.3-75.5%, while REs of benzene and formaldehyde (HCHO) passed through the biofilter were 39.7% and 44.9%, respectively. Hence, it was confirmed that the wall-typed botanical biofilter suitable for indoor plants was very effective for indoor air purification.

Impact of Indoor Air Quality on the Eye Conditions of Occupants in Newly-built University Buildings (새 학교 건물 내 실내공기질이 재실자의 안구에 미치는 영향)

  • Kim, Woo-Jae;Kim, Sun-Duk;Kim, Hyojin;Kim, Ho-Hyun;Lee, Cheol-Min;Kim, Yoon-Shin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.201-207
    • /
    • 2011
  • Purpose: This study was to find out the influence on eyes of indoor air quality in college students taking course, such as Sick-building syndrome symptoms and effects on the eye in new-built university buildings. Methods: We selected a new building in a university located in Metro Seoul and college students in a department for the study. The number of total participants was 33, to whom questionnaire surveys were conducted in advance to check individual traits (gender, age, whether to smoke, whether to wear contact lenses, or whether to drink). The first questionnaire surveys and checking of ocular symptoms to first indoor hazardous materials were conducted in October and two months later the second surveys and checking were carried out in December. The indoor air quality was measured when conducting the first questionnaire surveys and the second questionnaire surveys; especially measurements of gaseous materials such as aldehydes and VOCs in the indoor air were conducted. Results: Indoor air quality of the new building was as follows: formaldehyde level was 22.90 ${\mu}g/m^3$ in the first measurement and 16.79 ${\mu}g/m^3$ in the second measurement. In addition, most materials showed higher value in the first measurement. The level of TVOC was statistically significant (p<0.05) decreased on 448.54 ${\mu}g/m^3$ in the first and 62.55 ${\mu}g/m^3$ in the second. In clinical assessments to check ocular symptoms caused by eye irritations, dry eye syndrome was found in the first and second exposures. When comparing the first and second assessments, dry eyes deteriorated in the morning of the second attempt compared to the first one. Conclusions: In the survey of ocular symptoms and the measurement of indoor air quality, the level of formaldehyde was measured higher in the second attempt than the first; thus, it was confirmed the influence of indoor air quality in a new building upon ocular symptoms of occupants.

A study on the calibration characteristics of organic fatty acids designated as new offensive odorants by cryogenic trapping-thermal desorption technique (유기지방산 신규악취물질에 대한 저온농축 열탈착방식 (Thermal desorber)의 검량특성 연구)

  • Ahn, Ji-Won;Kim, Ki-Hyun;Im, Moon-Soon;Ju, Do-Weon
    • Analytical Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.488-497
    • /
    • 2009
  • In this study, analytical methodology for several organic fatty acids (OFA: propionic acid (PA), butyric acid (BA), isovaleric acid (IA), and valeric acid (VA)) designated as new offensive odorants in Korea (as of year 2010) was investigated along with some odorous VOCs (styrene, toluene, xylene, methyl ethyl ketone, methyl isobutyl ketone, butyl acetate, and isobutyl alcohol). For this purpose, working standards (WS) containing all of these 13 compounds were loaded into adsorption tube filled with Tenax TA, and analyzed by gas chromatography (GC) system thermal desorber interfaced with. The analytical sensitivities of organic fatty acids expressed in terms of detection limit (both in absolute mass (ng) and concentration (ppb)) were lower by 1.5-2 times than other compounds (PA: 0.24 ng (0.16 ppb), BA: 0.19 ng (0.11 ppb), IA: 0.15 ng (0.07 ppb), and VA: 0.28 ng (0.13 ppb)). The precision of BA, IA, and VA, if assessed in terms of relative standard error (RSE), maintained above 5%, while the precison of other compounds were below 5%. The reproducibility of analysis improved with the aid of internal standard calibration (PA: $1.1{\pm}0.4%$, BA: $10{\pm}0.46$, IA; $12{\pm}0.3%$, VA: $4{\pm}0.1%$), respectively. The results of this study showed that organic fatty acid can be analyzed using adsorption tube and thermal desorber in a more reliable way to replace alkali absorption method introduced in the odor prevention law of the Korea Ministry of Environment (KMOE).

Estimation of Personal Exposure to Air Pollutants for Workers Using Time Activity Pattern and Air Concentration of Microenvironments (시간활동 양상과 국소환경 농도를 이용한 근로자의 유해 공기오염물질 노출 예측)

  • Lee, Hyunsoo;Lee, Seokyong;Lee, Byoungjun;Heo, Jung;Kim, Sunshin;Yang, Wonho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.436-445
    • /
    • 2014
  • Objectives: Time-activity studies have become an integral part of comprehensive exposure assessment and personal exposure modeling. The aims of this study were to estimate exposure levels to nitrogen dioxide($NO_2$) and volatile organic compounds(VOCs), and to compare estimated exposures by using time-activity patterns and indoor air concentrations. Methods: The major microenvironments for office workers were selected using the Time-Use Survey conducted by the National Statistical Office in Korea in 2009. A total of 9,194 and 6,130 workers were recruited for weekdays and weekends, respectively, from the Time-Use Survey. It appears that workers were spending about 50% of their time in the house and about 30% of their time in other indoor areas during the weekdays. In addition, we analyzed the time-activity patterns of 20 office workers and indoor air concentrations in Daegu using a questionnaire and time-activity diary. Estimated exposures were compared with measured concentrations using the time-weighted average analysis of air pollutants. Conclusions: According to the time-activity pattern for the office workers, time spent in the residence indoors during the summer and winter have been shown as $11.12{\pm}2.20$ hours and $12.48{\pm}1.77$ hours, respectively, which indicates higher hours in the winter. Time spent in the office in the summer has been shown to be 1.5 hours higher than in the winter. The target pollutants demonstrate a positive correlation ($R^2=0.076{\sim}0.553$)in the personal exposure results derived from direct measurement and estimated personal exposure concentrations by applying the time activity pattern, as well as measured concentration of the partial environment to the TWA model. However, these correlations were not statistically significant. This may be explained by the difference being caused by other indoor environments, such as a bar, cafe, or diner.

A Subjective Symptom Level and Satisfaction Factor by Indoor Air Quality According to Ventilation System in Dental Clinic (치과병·의원 환기방법에 따른 실내공기질 자각증상 수준 및 근무환경 만족요인)

  • Choi, Mi-Suk;Ji, Dong-Ha;Choi, Jae-Ho
    • Journal of dental hygiene science
    • /
    • v.11 no.4
    • /
    • pp.353-359
    • /
    • 2011
  • This study was designed to identify a subjective symptom level by Indoor air according to ventilation system in Dental Clinic. The number of respondents was 582 who work in dental clinic and period of investigation was October 2010 through January 2011. A structured questionnaire was employed to evaluate the level of participants' sociodemographics, job-related factors, work place condition, a subjective symptom. Most of respondents were answered that time for symptom to begin was at around 2 P.M. and time for symptom to feel serve pain was at around 3 P.M. and ventilation frequency per a day was often in case of individual cooling and heating system. More often natural ventilation and in case of individual cooling and heating system, the level of subject symptom was low and multiple regression analysis has found that indoor air quality related elements were main factors that influence to the feeling of satisfaction in work place. The results of this study suggest that more often natural ventilation was very important to reduce the level of subjective symptom. Thus, a management program for indoor air quality is strongly recommended by natural ventilation, maintenance man for promotion of quality of life in dental hygienist and to improve dental service and competitiveness.

LC50 Determination of tert-Butyl Acetate using a Nose Only Inhalation Exposure in Rats

  • Yang, Young-Su;Lee, Jin-Soo;Kwon, Soon-Jin;Seo, Heung-Sik;Choi, Seong-Jin;Yu, Hee-Jin;Song, Jeong-Ah;Lee, Kyu-Hong;Lee, Byoung-Seok;Heo, Jeong-Doo;Cho, Kyu-Hyuk;Song, Chang-Woo
    • Toxicological Research
    • /
    • v.26 no.4
    • /
    • pp.293-300
    • /
    • 2010
  • tert-Butyl acetate (TBAc) is an organic solvent, which is commonly used in architectural coatings and industrial solvents. It has recently been exempted from the definition of a volatile organic compound (VOC) by the Air Resources Board (ARB). Since the use of TBAc as a substitute for other VOCs has increased, thus its potential risk in humans has also increased. However, its inhalation toxicity data in the literature are very limited. Hence, inhalation exposure to TBAc was carried out to investigate its toxic effects in this study. Adult male rats were exposed to TBAc for 4 h for 1 day by using a nose-only inhalation exposure chamber (low dose, $2370\;mg/m^3$ (500 ppm); high dose, $9482\;mg/m^3$ (2000 ppm)). Shamtreated control rats were exposed to clean air in the inhalation chamber for the same period. The animals were killed at 2, 7, and 15 days after exposure. At each time point, body weight measurement, bronchoalveolar lavage fluid (BALF) analysis, histopathological examination, and biochemical assay were performed. No treatment-related abnormal effects were observed in any group according to time course. Based on those findings, the median lethal concentration ($LC_{50}$) of TBAc was over $9482\;mg/m^3$ in this study. According to the MSDS, the 4 h $LC_{50}$ for TBAc for rats is over $2230\;mg/m^3$. We suggested that this value is changed and these findings may be applied in the risk assessment of TBAc which could be beneficial in a sub-acute study.

Operating Parameters and Performance of Biotrickling Filtration for Air Pollution Control (대기오염물질 제어를 위한 생물살수여과법의 운전인자와 성능평가)

  • Won, Yang-Soo
    • Applied Chemistry for Engineering
    • /
    • v.16 no.4
    • /
    • pp.474-484
    • /
    • 2005
  • Biological treatment is a promising alternative to conventional air pollution control methods. Bioreactors for air pollution control have found most of their success in the treatment of dilute and high flow waste air streams containing volatile organic compounds and odor compounds. They offer several advantages over traditional technologies such as incineration or adsorption. These include lower treatment costs, absence of formation of secondary pollutants, no spent chemicals, low energy demand and low temperature treatment. The most widely used bioreactor for air pollution control is biofilter, but it has several limitations. In the past years major progress has been accomplished in the development of vapor phase bioreactor, in particular biotrickling filters. Biotrickling filters are more complex than biofilters, but are usually more effective, especially for the treatment of compounds which are difficult to degrade or compounds that generate acidic by-products. While the level of understanding of biotrickling filtration process for VOCs still remains limited, the evident success of biotreatment of VOC in air stimulated the pursue of acitve research. This paper presents fundamental and theoretical/practical aspect of air pollution control in biotrickling filter. Special emphasis is given to the operating parameters and the factors influencing performance for air pollution control in biotrickling filter.

A Study on the Comparison of Air Pollutants Emissions according to Three Averaging Methods of Vehicular Travel Speed (자동차 평균통행속도 적용방식에 따른 대기오염 배출량 비교 연구)

  • Cho Kyu-Tak
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.4
    • /
    • pp.401-411
    • /
    • 2005
  • This study was conducted to develop a method to be able to estimate the vehicular emissions according to spatial scales-Seoul province, 25 counties and hundreds of grids $(1km{\times}1km)$. First, the emissions at each spatial scale was calculated by using the road network and the travel volume and speed of each link modeled by travel demand model (TDM). Second, the emission at each spatial scale was calculated on the basis of average speeds estimated by using three kinds of averaging method. These are called the provincial, volume-delay function (VDF) and zonal method, respectively. Third, three kinds of emissions and those by TDM are compared each other at three spatial scales. In Seoul (provincial scale), three kinds of emissions are less than those by TDM, but the differences of TDM from three speed averaging methods (SAMs) are small. The relative ratios of three SAMs to TDM are $88\~90\%\;in\;CO,\;99\~100\%\;in\;NOx,\;84\~85\%$ in VOCs. At county scale, NOx among three pollutants showed the highest correlation between TDM and three SAMs and the zonal method among three SAMs was proven to be the highest correlation with TDM. NOx showed the coefficients $(R^2)$ greater than 0.9 in all three SAMs but CO and VOC showed the coefficients $(R^2)$ greater than 0.9 in only zonal method. Slopes of co..elations of all pollutants showed the values close to '1' in zonal method. In the other two SAMs, slopes of NOx showed the values close to '1', but those of CO and VOC showed the values less than 0.85. At grid scale, correlations between TDM and three SAMs were not high. CO showed $0.68\~0.77\;in\;R^2s\;and\;58\~0.68$ in slopes. NOx showed $0.90\~0.94\;in\;R^2s\;and\;0.86\~0.94$ in slopes. VOC showed $0.56\~0.70\;in\;R^2s\;and\;0.48\~0.57$ in slopes. There are not high correlations between TDM and three SAMs in grid scale. This study showed that there is the most suitable method for calculating the average travel speed at each spatial scale and it is thought that the zonal method is more suitable than the VDF or provincial method.