• Title/Summary/Keyword: environment of room

Search Result 1,732, Processing Time 0.025 seconds

Test Evaluation of a Linerless Composite Propellant Tank Using the Composite Collapsible Mandrel (복합재 분리형 맨드릴을 이용한 라이너 없는 복합재 추진제 탱크에 대한 시험 평가)

  • Seung Yun Rhee;Kwangsoo Kim;Young-Ha Yoon;Moo-Keun Yi;Hee Chul Kim
    • Composites Research
    • /
    • v.36 no.2
    • /
    • pp.132-139
    • /
    • 2023
  • A linerless composite propellant tank was designed and manufactured by using the carbon fiber-reinforced composite materials which have superior strength-to-weight ratio in order to reduce weight of the tank. In this research, we designed a sub-scale composite propellant tank with a diameter of 800 mm to withstand an MEOP of 1.7 MPa. We manufactured the boss of the tank by using the same composite materials to reduce the thermal expansion difference between the boss and the secondary-bonded composite layers of the barrel in the cryogenic environment. We used the collapsible mandrel to manufacture the tank without any liner. The mandrel was made from epoxy-based composite tooling prepregs to reduce weight of the mandrel. We manufactured the test tanks by laying up the carbon fiber fabric prepregs manually on the mandrel and then applying the autoclave cure process. We performed a proof test, a helium tightness test, a repeated pressurization test, and a burst test in room temperature. The test results demonstrate that the proposed design and manufacture process satisfies all strength requirements as well as an anti-leakage requirement.

Experimental Study of the Wireless Communication System by Surface Wave Communication through Confined Spaces on Vessels (선박 밀폐 공간 무선통신 구현을 위한 표면파 통신의 선박 활용연구)

  • Kong, Jin-Woo;Song, Suk-Gun;Kim, Hak-Sun;Kim, Bu-Young;Shim, Woo-Seong
    • Journal of Navigation and Port Research
    • /
    • v.45 no.6
    • /
    • pp.366-371
    • /
    • 2021
  • This study suggests surface wave communication, which uses a metal surface as a medium, to provide wireless communication in the extreme environment due to surrounding metal materials on vessels. The test was conducted on a G/T 265 tons tug boat to confirm the possibility of surface wave communication between a bridge and each designated space in the ship. As a result, the transmission speed was 13Mbps on average. In a test case of the bridge via the engine room, the transmission speed was 4.3Mbps on engine running and 1.2Mbps on sailing. It overcame this by partially changing the equipment installation location. Surface wave communication in bow storage, a fully enclosed space, had 8Mbps better transmission speed than wireless communication; this confirmed the superiority of surface wave communication in confined spaces on a vessel. Additional surface wave generators were designed and applied to resolve the paint issue. It is expected to use surface wave communication to implement the new wireless solution for Maritime-IoT system on vessels.

Experimental Study of Wireless Communication System by Surface wave Communication through Confined Spaces on Vessels (선박 밀폐 공간 무선통신 구현을 위한 표면파 통신의 선박 활용 연구)

  • Jin-Woo Kong;Suk-Gun Song;Hak-Sun Kim;Bu-Young Kim;Woo-Seong Shim
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2021.11a
    • /
    • pp.127-128
    • /
    • 2021
  • This study suggests surface wave communication, which uses a metal surface as a medium, to provide wireless communication in the extreme environment due to surrounding metal materials on vessels. The test was conducted on a G/T 265 tons tug boat, and to confirm the possibility of surface wave communication between a bridge and each designated space in the boat. As a result, the transmission speed was 13Mbps in average. For the test case between the bridge and the engine room, transmission speed was 4.3Mbps while the engine was on, and 1.2Mbps during sailing. It was able to be overcome by partially changing the equipment installation location. Surface wave communication in a bow storage, a fully enclosed space, had 8Mbps better transmission speed than wireless communication; this confirmed the superiority of surface wave communication in confined spaces on a vessel. Additional surface wave generators were designed and applied to resolve the paint issue. It is expected to apply surface wave communication to implement the new wireless solution on vessels.

  • PDF

Sprouting Inhibition after CIPC Spraying on Early and Mid-season Potato Varieties during Storage in Semi-underground Warehouse at Room Temperature in Summer (CIPC 처리한 조·중생종 감자의 반지하 저장고를 이용한 하계 실온저장 중 맹아 억제 효과 비교)

  • Kyusuk Han;Byung-Sup Kim;Sae Jin Hong;Young Hun Lee
    • Journal of Bio-Environment Control
    • /
    • v.32 no.2
    • /
    • pp.172-180
    • /
    • 2023
  • This study was carried out to determine the sprouting period of early and mid-season varieties, which includes 'Atlantic', 'Chubaek', and 'Superior', during the summer storage period in a semi-underground warehouse without cooling system. And also it was investigated the effect of chlorpropham [Propan-2-yl N-(3-chlorophenyl)carbamate, CIPC] treatment on the sprouting inhibition for the varieties. This study was conducted to figure out a sprout inhibitory effect when CIPC was applied to 1kg of the potato tubers at concentrations of 10 mg and 20 mg which are lower than the treatment concentrations of ca 30 mg prescribed by the positive list system (PLS). The internal temperature of the warehouse used in this experiment was lowered by 5℃ or more than the outside temperature. The difference between the lowest and highest temperature during the experiment throughout the day was 5℃. It showed the effect of reducing to 1/2 of the difference in outdoor temperature. As for the sprouting of potatoes, the extremely early variety 'Chubaek' sprouts appeared at the 6th week of storage of control and it was the fastest sprouting potato among the control groups of the varieties. Sprouting began to appear in the Superior at the 6th week of storage, while the 'Atlantic' sprouted at the 8th week of storage. The appearance of sprouts was suppressed in all treatment groups of 'Atlantic' and 'Superior' varieties in CIPC treatments. Sprouts were observed in all treatment groups of 'Chubaek' after the 7th week, but the elongations of the sprouts in tubers were completely inhibited until the 8th week of storage. 'Atlantic' and 'Superior' seemed to have a sprouting inhibitory effect even with a low CIPC concentration of 10 mg·kg-1, with the exception of extremely early variety 'Chubaek' that breaks out of the dormancy quickly. Although weight loss occurred continuously during storage, it was minor loss of 0.7-1.6%. There was no consistent trend for changes of the loss in the varieties and CIPC treatments. Most common pathological disorder was the dry rot during the experiment, but only few were affected. The use of the tubers treated at 18℃ and 90% RH for 10 days and the rack of refrigeration system which lead to lack of convection seemed to have suppressed the spread of pathogens.

A Study on the Effects of an Increase in the Height of Ship's Accommodation Area on Safe Evacuation in Emergency Situation (선박 거주구역의 높이가 피난안전에 미치는 영향에 대한 연구)

  • Kim, Won-Ouk;Kim, Jong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.1
    • /
    • pp.69-73
    • /
    • 2011
  • Unlike land fires, Fires on board a ship are not likely to be extinguished by skilled human resources using a variety of fire fighting equipments, but have to be brought under control on board a ship itself despite of difficult task. There are more cases of deaths from suffocation by smoke than from an increased temperature by heat in fires on board ships, because crew fail to secure a sufficient visibility range enough to escape from the scene of a fire or to leave the ship as early as possible. On the assumption that the height of ship's accommodation area increases from 2.0m to 2.3m comparable to the height of apartments on the ground in Korea, behaviors of fire smokes between the cases of 2.0m and 2.3m heights were compared and analyzed. Based on the blue print of the existing Training Ship "Hanbada", a new blueprint with the 30 cm height adjustment was additionally created. FDS (Fire Dynamic Simulator), which was created by the NIST in the United States and is the most widely distributed simulator for fires, was used to conduct a simulation and predict results. The results of simulation on the basis of temperature of $60^{\circ}C$ showed a safe evacuation period of time at the position 10m apart from the scene of a fire to increase by 55.8 seconds, when the height of ship's accommodation area increased from 2.0m to 2.3m. The results of simulation on the basis of visibility range of 6m showed the safe evacuation periods of time at the positions 10m, 20m and 30m apart from the scene of a fire to increase by 27.1 seconds, 109.2 seconds and 73.3 seconds, respectively, as the height of ship's accommodation area increased from 2.0m to 2.3m. This means that crew can escape more safely from a scene of fires on board when the height of ship's accommodation area is increased and equal to the height of living room in a building on land.

Indoor Exposure and Health Risk of Polycyclic Aromatic Hydrocarbons (PAHs) via Public Facilities PM2.5, Korea (II)

  • Kim, Ho-Hyun;Lee, Geon-Woo;Yang, Ji-Yeon;Jeon, Jun-Min;Lee, Woo-Seok;Lim, Jung-Yun;Lee, Han-Seul;Gwak, Yoon-Kyung;Shin, Dong-Chun;Lim, Young-Wook
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.1
    • /
    • pp.35-47
    • /
    • 2014
  • The purpose of the study is to evaluate the pollution level (gaseous and particle phase) in the public facilities for the PAHs, non-regulated materials, forecast the risk level by the health risk assessment (HRA) and propose the guideline level. PAH assessments through sampling of particulate matter of diameter < 2.5 ${\mu}m$ ($PM_{2.5}$). The user and worker exposure scenario for the PAHs consists of 24-hour exposure scenario (WIES) assuming the worst case and the normal exposure scenario (MIES) based on the survey. This study investigated 20 PAH substances selected out of 32 substances known to be carcinogenic or potentially carcinogenic. The risk assessment applies major toxic equivalency factor (TEF) proposed from existing studies and estaimates individual Excess Cancer Risk (ECR). The study assesses the fine dusts ($PM_{2.5}$) and the exposure levels of the gaseous and particle PAH materials for 6 spots in each 8 facility, e.g. underground subway stations, child-care facilities, elderly care facilities, super market, indoor parking lot, terminal waiting room, internet caf$\acute{e}$ (PC-rooms), movie theater. For internet caf$\acute{e}$ (PC-rooms) in particular, that marks the highest $PM_{2.5}$ concentration and the average concentration of 10 spots (2 spots for each cafe) is 73.3 ${\mu}g/m^3$ (range: 6.8-185.2 ${\mu}g/m^3$). The high level of $PM_{2.5}$ seen in internet cafes was likely due to indoor smoking in most cases. For the gaseous PAHs, the detection frequency for 4-5 rings shows high and the elements with 6 rings shows low frequency. For the particle PAHs, the detection frequency for 2-3 rings shows low and the elements with 6 rings show high frequency. As a result, it is investigated that the most important PAHs are the naphthalene, acenaphthene and phenanthrene from the study of Kim et al. (2013) and this annual study. The health risk assessment demonstrates that each facility shows the level of $10^{-6}-10^{-4}$. Considering standards and local source of pollution levels, it is judged that the management standard of the benzo (a)pyrene, one of the PAHs, shall be managed with the range of 0.5-1.2 $ng/m^3$. Smoking and ventilation were considered as the most important PAHs exposure associated with public facility $PM_{2.5}$. This study only estimated for inhalation health risk of PAHs and focused on the associated cancer risk, while multiple measurements would be necessary for public health and policy.

A Study on the Bed Climate and the Physiological Responses in Sleep. - On Ondol Environment - (수면시 침상기후와 인체생리반응에 관한 연구 -온돌환경을 중심으로-)

  • Kim Myung Ju;Choi Jeong Wha
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.2 s.38
    • /
    • pp.77-87
    • /
    • 1991
  • The purpose of this study were to investigate the bed climate and the physiological responses in sleep on the traditional Korean floor heating system called Ondol. Ondol has been the most widely used heating system in Korea, yet there has been a no systematic studies examined its environmental effects on human body. Experimental room was constructed to match the typical thermal environment of Ondol. (floor surface temperature; $32\~33^{\circ}C$, air temperature; $22.5{\pm}1.0^{\circ}C$, relative humidity; $64.0{\pm}4.0\%$RH, air velocity; 0.25 m/sec.) Three different combinations of bedclothes were chosen for the experiment based on the study results showing that they were the most widely used types in Korea. Type 1 was the combination of a cotton-padded mattress with a cotton-padded Korean style blanket. Type 2 was a cotton-padded mattress with a cotton-guilted Korean style blanket. Type 3 was a cotton-padded matless with a polyacryl blanket. Thermal resistance of each of these combina-tions in the bedclothes was measured using thermal manikin. Two adult female was chosen for the seven hour sleeping experiment which was known to be the average sleeping hours of Korean adult female. The bed climate was measured with the temperature under the mattress, the surface temper-ature of the mattress, and the air temperature and the relative humidity of the space between the mattress and blanket. The skin temperature, rectal temperature of the subjects and the bed climate were measured eight times, one hour before the experiment and every hour during the experiment. The weight loss and the subjective sensation were measured for the each subjects before and after the experiment. The procedure was repeated twice with two subjects and three types of bedclothes, yielding twelve combinations of results. The results were as follows; 1. With the surface temperature of $32\~33^{\circ}C$ of Ondol, air temperature was $22.5{\pm}1.0^{\circ}C$ with $64.0{\pm}4.0\%$ RH. The bed climates were $39.2{\pm}40.8^{\circ}C$ under the mattress, $35.3\~36.2^{\circ}C$ on the mattress, and $26.9\~32.0^{\circ}C$ with $56.0\~71.3\%$ RH between the mattress and the blanket. 2. Mean skim temperature during sleep was 34.2"C with local skin temperature of $34.0\~35.5^{\circ}C$. The skin temperatures of abdomen, thigh, foot were higher than the other parts of the body. 3. The skin temperature of chest, thigh, leg and back varied significantly according to the combinations of bedclothes. With the cotton-padded blanket, the skin temperature was the highest, while with the cotton-guilted blanket showed lowest. 4. Examining the relationship between the mean skin temperature and the local skin temper-ature, the chest temperature showed the highest correlation with the former. Therefore, the chest temperature can be recommended to represent the skin temperature in measuring the bed climate. 5. The subjective bed climates were $39.0\~40.4^{\circ}C$ under the mattress, $35.2\~35.9^{\circ}C$ on the mattress, $29.8\~31.6^{\circ}C$ with $56.8\~68.4\%$ RH between the mattress and blanket. In sum, from this experiment we not only obtained the reliable value of bed climates on Ondol, but also showed that the bed climates and the physiological responses were affected differently according to the materials of bed clothes.

  • PDF

A Comparison of Postharvest Physiology and Storability of Paprika Fresh-Cut Made from Disordered and Normal Fruits (착색단고추 생리장해과와 정상과의 수확 후 생리 및 신선편이의 저장성 비교)

  • Yoo, Tae-Jong;Jung, Hyun-Jin;Choi, In-Lee;Kim, Il-Seop;Kang, Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.19 no.1
    • /
    • pp.49-54
    • /
    • 2010
  • The study was conducted to compare the postharvest physiology and storability of fresh cut paprika fruits classified by normal, blossom end rot(BER), and misshapen (or knots) fruit. Some disordered paprika fruits that were produced frequently during high temperature season in highland, were sorted out to non-marketable products. These fruits are mostly wasted, but some of them may be used for fresh cut. The respiration rate of fresh cut paprika fruits was lower and ethylene production rate was higher in normal fruits than in disordered fruits, but there was no significant difference. The fresh-cut paprika fruits were stored in MAP conditions at $4^{\circ}C$, $9^{\circ}C$ and room temperature in 25 ${\mu}m$ and 50 ${\mu}m$ thickness ceramic film packaging. The fresh weight of fresh cut paprika fruits decreased below to 1.1% regardless of fruit types, but the fresh weight loss increased in thinner packaging materials and lower storage temperatures. There were not significant different carbon dioxide and oxygen contents in MAP of all fruit types, while $4^{\circ}C$ storage temperature treatment and 25 ${\mu}m$ thickness ceramic film treatment had lower carbon dioxide and higher oxygen contents. Moreover, the carbon dioxide and oxygen contents were changed rapidly at 9 days in $4^{\circ}C$ storage and at 6 days in $9^{\circ}C$ storage when the visual quality of fresh cut decreased dramatically. The ethylene concentration of packages was below 7 ${\mu}l{\cdot}l^{-1}$ in all treatments during storage, while the treatments of thinner packaging material and lower storage temperature showed lower ethylene concentration. The fresh cut of disordered fruits showed less visual quality than normal fruit treatment in both $4^{\circ}C$ and $9^{\circ}C$ storage temperatures, but there was no significant difference. The value of $4^{\circ}C$ treatment that measured 12 days in storage was higher than $9^{\circ}C$ treatment that measured 9 days in storage. The results suggest that the disordered fruits may be used to fresh cut product without any concerns that they will decreased the value of commodities more quickly than the fresh cut made of marketable paprika fruits. As the fresh cut paprika fruits stored in MAP condition, the more effective storage temperature is $4^{\circ}C$ that may have induced chilling injury a whole fruit of the paprika.

Analysis of the Issues received by Quality Improvement Department and their Management in a Medical Center (일 의료원의 통합 고충처리센터 접수 내용과 이에 대한 해결방안 분석)

  • Tark, Kwan-Chul;Park, Hyun-Ju;Chun, Ja-Hae;Kang, Eun-Sook;Moon, Ju-Young;Choi, Mi-Young;Kim, Hyun-Ju;Kang, Jin-Kyung
    • Quality Improvement in Health Care
    • /
    • v.7 no.1
    • /
    • pp.118-131
    • /
    • 2000
  • Background : A continuous healthcare quality improvement is needed to provide high quality healthcare service as well as to maintain trust in terms of satisfying the needs of the patients. Recently it also became an essential issue. in hospital management, recognized for it's competitive potentiality among healthcare organization groups. This study was conducted to analyze patient complaints and issues received by the Quality Improvement Department. Its purpose is to improve healthcare qualities within the hospital, as well as establish policies and appropriate strategies in hospital management. Method : From July 1st to September 30th of the year 1999, we analyzed all complaints and issues made by various patients and their families, which were received through 24 hour phone consultation, numerous suggestion boxes, letters and E-mails, The issues were classified into 16 different categories based on a Patient Satisfaction Assessment Tool. All data were segregated according to the departmental frequencies and their contents. To come up with for environmental and patient satisfaction improvement, all complaints or issues were communicated with hospital administrators, medical and nursing staff and employees. Comprehensive customer satisfaction activities including improving phone etiquette were discussed in Customer Satisfaction Team, CQI Team and each Department. All opportunities for improvement were implemented. Feedback actions were discussed. Results : A total of 317 cases were collected. Issues regarding parking and other accommodation facilities were most common complaints that were 14.5% of total. Issues regarding admission rooms (10.7%), admission procedures (10.7%), waiting room environment (8.8%), nurses and nurse assistants (7.6%), physicians (6.6%) and others (23%) followed. Thirteen of 45 departments received more than 8 complaints. The Nursing Department had the most complaint, receiving 9.8% of total complaints. Complaints regarding the Nursing Department were predominantly related to the environment of patient rooms. The Department of Psychiatry for phone etiquette (4.7%), Department of Otolaryngology for the nursing staff's attitude and phone etiquette (4.4%), and the Admission Department followed. As a part of efforts to improve patient satisfaction, a new parking structure was built and reallocation of the parking space was done. Renovation of other accommodation facilities were carried out by hospital administration, Monthly phone call and answering attitude survey was done by QI Department. Based on this survey we made a phone etiquette manual and distributed throughout the hospital. Compare to the last year, Patient Satisfaction Index measured by Korea Productivity Center using National Customer Satisfaction Index was improved 7 points. According to our organization's own study, we confirmed the phone etiquette was improved 11% than last year. Conclusions : Issues related to parking and other accommodation facilities ranked first followed by complaints made regarding the patient care area, the admission and cashier process, and nurses' and doctors' attitude. The Nursing and Psychiatry Departments need improvement regarding phone etiquette. Results were shared and played a vital role in policymaking and strategic planning of the hospital. It is imperative that we keep our database updated by listening to and solving the needs of each patient. The CQI activities can be achieved only by full commitment of the hospital top management supported by related personal.

  • PDF

CFD Analysis for Microclimate of Venlo Type Glasshouse with the Screen Height and Air-inflow Quantity (스크린설치높이·공기유입량 차이에 따른 벤로형 유리온실 미기상 CFD 유동해석)

  • Yang, Won Mo
    • Journal of Bio-Environment Control
    • /
    • v.29 no.1
    • /
    • pp.52-61
    • /
    • 2020
  • The natural change of winter night temperature from 00:00 to 04:30 O'clock with the different height of thermal screen in a venlo type glasshouse (W59×L68×H5.9 m) was studied using computational fluid dynamics (CFD). At the early stage of CFD analysis, the room temperature decrease of glasshouse with the 5.9 m height of thermal screen were faster than it with the 4.1m height of thermal screen, but at 2 hr after analysis it was slower than in it with the 4,1m, the temperature difference was 0.6℃ after 4 hr. If we consider that turn on the heater when the temperature were decrease below 13℃ at 1hr after CFD analysis, it is good for energy saving in the glasshouse with the 4.1 m height of thermal screen rather than in it with the 5.9 m height, because of the temperature decrease were slow during 2 hrs after analysis. The airflow at the height of 2 m which were grown tomato were fast and wide in the glasshouse with the 5.9 m height thermal screen rather than in it with the 4.1 m, the speed difference was 0.034m·s-1 at 1hr after CFD analysis. The effect of temperature decrease in summer season were compared with the different height of shading screen from 12:00 to 14:30 O'clock. The height of shading screen were 5.7, 3.9 m, the gap of it were 30%. The air-inflow quantity by the fan with duct at lower part of venlo glasshouse was 0.67 ㎥·s-1 until 1hr and to increase 3 times of it from 1hr after analysis. The roof window were open 100%. Until 1hr of CFD analysis, the temperature in the 30% open of shading screen was 0.9℃ higher than in the none shading screen. From 13:00 O'clock when the air-inlet quantity to increase 3 times, the temperature in case 30% gap of shading screen were decreased compare with the none shading screen, the temperature difference was 0.5℃ at 14:30 O'clock. The temperature on the floor surface in case 30% gap of shading screen were lower with it's height increase, the temperature difference was 8℃ compare with none shading screen. The relative humidity difference were insignificant by the height and gap of shading screen.