• Title/Summary/Keyword: engineering technology

Search Result 93,090, Processing Time 0.119 seconds

A Study on Mechanical Errors in Cone Beam Computed Tomography(CBCT) System (콘빔 전산화단층촬영(CBCT) 시스템에서 기계적 오류에 관한 연구)

  • Lee, Yi-Seong;Yoo, Eun-Jeong;Kim, Seung-Keun;Choi, Kyoung-Sik;Lee, Jeong-Woo;Suh, Tae-Suk;Kim, Joeng-Koo
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • This study investigated the rate of setup variance by the rotating unbalance of gantry in image-guided radiation therapy. The equipments used linear accelerator(Elekta Synergy TM, UK) and a three-dimensional volume imaging mode(3D Volume View) in cone beam computed tomography(CBCT) system. 2D images obtained by rotating $360^{\circ}$and $180^{\circ}$ were reconstructed to 3D image. Catpan503 phantom and homogeneous phantom were used to measure the setup errors. Ball-bearing phantom was used to check the rotation axis of the CBCT. The volume image from CBCT using Catphan503 phantom and homogeneous phantom were analyzed and compared to images from conventional CT in the six dimensional view(X, Y, Z, Roll, Pitch, and Yaw). The variance ratio of setup error were difference in X 0.6 mm, Y 0.5 mm Z 0.5 mm when the gantry rotated $360^{\circ}$ in orthogonal coordinate. whereas rotated $180^{\circ}$, the error measured 0.9 mm, 0.2 mm, 0.3 mm in X, Y, Z respectively. In the rotating coordinates, the more increased the rotating unbalance, the more raised average ratio of setup errors. The resolution of CBCT images showed 2 level of difference in the table recommended. CBCT had a good agreement compared to each recommended values which is the mechanical safety, geometry accuracy and image quality. The rotating unbalance of gentry vary hardly in orthogonal coordinate. However, in rotating coordinate of gantry exceeded the ${\pm}1^{\circ}$ of recommended value. Therefore, when we do sophisticated radiation therapy six dimensional correction is needed.

Electrochemical Performance as the Positive Electrode of Polyaniline and Polypyrrole Hollow Sphere with Different Shell Thickness (껍질 두께가 다른 폴리아닐린과 폴리피롤 속 빈 구형체 양전극의 전기화학적 성능)

  • Yun, Su-Ryeon;Hwang, Seung-Gi;Cho, Sung-Woo;Kang, Yongku;Ryu, Kawng-Sun
    • Applied Chemistry for Engineering
    • /
    • v.23 no.2
    • /
    • pp.131-137
    • /
    • 2012
  • Polyaniline (PANI) and polypyrrole (Ppy) hollow sphere structures with controlled shell thicknesses can be easily synthesized than those of using a layer-by-layer method for cathode active material of lithium-ion batteries. Polystyrene (PS) core was synthesized by emulsion polymerization using an anion surfactant. The shell thicknesses of PANI and Ppy were controlled by amounts of aniline and pyrrole monomers. PS was removed by an organic solution. This structure increased in contact with an electrolyte and a specific capacity in lithium-ion batteries. But polymers have disadvantages such as the difficult control of molecular weights and low densities. These disadvantages were completed by controlled shell thicknesses. The amount of aniline monomer increased from 1.2, 2.4, 3.6, 4.8 to 6.0 mL, and the shell thicknesses were 30.2, 38.0, 42.2, 48.2, and 52.4 nm, respectively. And the amount of pyrrole monomer was 0.6, 1.2, 2.4 and 3.6 mL, the shell thicknesses were 16.0, 22.0, 27.0 and 34.0 nm, respectively. In the cathode materials with controlled shell thicknesses, shell thicknesses of the PANI hollow spheres were 30.2, 42.2, and 52.4 nm, and discharge specific capacities of after 10 cycle were ~18, ~29, and ~62 mAh/g, respectively. The shell thicknesses of the Ppy hollow spheres were 16.0, 22.0, 27.0 and 34.0 nm, and discharge specific capacities of after 15 cycle were ~15, ~36, ~56, and ~77 mAh/g, respectively. Thus, shell thicknesses of PANI and Ppy increased, the specific capacities increased.

Effect of SCODMn and pH Adjustment on Physicochemical Characteristics in Liquid Fertilizer Production Process Using Swine Manure (SCODMn 농도 및 pH 조정이 양돈분뇨의 후숙발효과정에 미치는 이화학적 영향)

  • Hong, In-Gi;Kim, Soo-Ryang;Lee, Myung-Gyu
    • Journal of Animal Environmental Science
    • /
    • v.18 no.sup
    • /
    • pp.13-20
    • /
    • 2012
  • This research investigated the effect of $SCOD_{Mn}$ concentrations and pH adjustment at the stage before land application, namely 2nd-aeration treatment stage of liquid fertilizer in the liquid fertilizer treatment process of swine manure on the physicochemical compositions of 2nd-aeration treated liquid fertilizer. The liquid fertilizer used in this research is the alkaline fermented liquid fertilizer of swine manure more than pH 9.0 through aeration treatment (Alkaline fermentation treatment group). About the alkaline liquid fertilizer, phosphate neutralization treatment was conducted with phosphoric acid and it was a phosphate neutralization treatment group. In 2nd-aeration treatment of liquid fertilizer for 30 days, each group was divided into alkaline treatment groups (T-1, T-2, and T-3) and phosphate neutralization treatment groups (T-4, T-5, and T-6) according to early $SCOD_{Mn}$ concentrations. The research results are as follows. 1. As for $SCOD_{Mn}$ reduction rate, the average 29.9% in alkaline treatment groups and the average 36.9% in phosphate neutralization treatment groups were shown and so the relatively high reduction rate was shown in phosphate neutralization treatment groups. 2. After finishing the experiment, the group of the lowest $SCOD_{Mn}$ concentrations was the phosphate neutralization treatment group, T-6 with the lowest inflow concentrations. In case the final goal level of 2nd-aeration treated liquid fertilizer is assumed as concentrations less than $SCOD_{Mn}$ 3,000 ppm, it would be desired that inflow concentrations of 2nd-aeration treatment groups are adjusted less than $SCOD_{Mn}$ 5,500 ppm. 3. As for the persistence rate of nitrogen, the average 29.3% in alkaline treatment groups and the average 38.9% in phosphate neutralization treatment groups were shown and so phosphate neutralization treatment groups showed the relatively low loss rate of nitrogen, meanwhile, in the case of T-P, phosphate neutralization treatment groups maintained high concentrations (average 1,473 ppm). 4. In the event of 2nd-aeration treatment of liquid fertilizer, "alkaline fermentation treatment" condition in 'low phosphate-low nitrogen' type and "phosphate neutralization treatment" condition in 'high phosphate-high nitrogen' type are expected to be favorable.

Validation of Load Calculation Method for Greenhouse Heating Design and Analysis of the Influence of Infiltration Loss and Ground Heat Exchange (온실 난방부하 산정방법의 검증 및 틈새환기와 지중전열의 영향 분석)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Horticultural Science & Technology
    • /
    • v.33 no.5
    • /
    • pp.647-657
    • /
    • 2015
  • To investigate a method for calculation of the heating load for environmental designs of horticultural facilities, measurements of total heating load, infiltration rate, and floor heat flux in a large-scale plastic greenhouse were analyzed comparatively with the calculation results. Effects of ground heat exchange and infiltration loss on the greenhouse heating load were examined. The ranges of the indoor and outdoor temperatures were $13.3{\pm}1.2^{\circ}C$ and $-9.4{\sim}+7.2^{\circ}C$ respectively during the experimental period. It was confirmed that the outdoor temperatures were valid in the range of the design temperatures for the greenhouse heating design in Korea. Average infiltration rate of the experimental greenhouse measured by a gas tracer method was $0.245h^{-1}$. Applying a constant ventilation heat transfer coefficient to the covering area of the greenhouse was found to have a methodological problem in the case of various sizes of greenhouses. Thus, it was considered that the method of using the volume and the infiltration rate of greenhouses was reasonable for the infiltration loss. Floor heat flux measured in the center of the greenhouse tended to increase toward negative slightly according to the differences between indoor and outdoor temperature. By contrast, floor heat flux measured at the side of the greenhouse tended to increase greatly into plus according to the temperature differences. Based on the measured results, a new calculation method for ground heat exchange was developed by adopting the concept of heat loss through the perimeter of greenhouses. The developed method coincided closely with the experimental result. Average transmission heat loss was shown to be directly proportional to the differences between indoor and outdoor temperature, but the average overall heat transfer coefficient tended to decrease. Thus, in calculating the transmission heat loss, the overall heat transfer coefficient must be selected based on design conditions. The overall heat transfer coefficient of the experimental greenhouse averaged $2.73W{\cdot}m^{-2}{\cdot}C^{-1}$, which represents a 60% heat savings rate compared with plastic greenhouses with a single covering. The total heating load included, transmission heat loss of 84.7~95.4%, infiltration loss of 4.4~9.5%, and ground heat exchange of -0.2~+6.3%. The transmission heat loss accounted for larger proportions in groups with low differences between indoor and outdoor temperature, whereas infiltration heat loss played the larger role in groups with high temperature differences. Ground heat exchange could either heighten or lessen the heating load, depending on the difference between indoor and outdoor temperature. Therefore, the selection of a reference temperature difference is important. Since infiltration loss takes on greater importance than ground heat exchange, measures for lessening the infiltration loss are required to conserve energy.

In vitro Multiplication through Single-Node Culture of Sea-Milkwort (Glaux maritima L.) (갯봄맞이(Glaux maritima L.) 실생의 단마디배양을 통한 기내증식)

  • Bae, Su-Ji;Kang, Beum-Chang;Jeong, Mihye;Kim, Soochong;Kim, Chang Kil;Han, Jeung-Sul
    • Horticultural Science & Technology
    • /
    • v.34 no.3
    • /
    • pp.461-471
    • /
    • 2016
  • This study was conducted to establish an in vitro propagation system for sea-milkwort (Glaux maritima L.), which is an endangered coastal plant species with high horticultural value. Two phenotypes, 'Red type (RT)' and 'Pistachio type (PT)' based on the colors of stem and flower, were obtained from a personal horticulturist in 2009 and used for this study as plant materials. The stock plants showed typical morphologies in flower, capsule, and seed appearances as previously reported. Low temperature treatment at $4^{\circ}C$ for four or more weeks after in vitro sowing maximized seed germination percentage, indicating that imbibition of seed and subsequent low temperature treatment are crucial for its germination. The in vitro seedlings had phenotypic variation, falling into 'RT' and 'PT' classes like the stock plants. Although slight differences depending on genotype and medium were recognized, the fourth or fifth nodes detached from the in vitro seedlings revealed the best multiplication efficacy when estimated on the basis of total number of nodes of newly developed axillary shoots. In addition, the nodes from 'RT' and 'PT' regenerated the most shoots on medium supplemented with $0.5mg{\cdot}L^{-1}$ BA alone and $0.5mg{\cdot}L^{-1}$ BA plus $0.5mg{\cdot}L^{-1}$ IAA, respectively. The node culture-derived plantlets were well acclimatized in a culture room ex vitro and completed the pseudo-annual life cycle coincident with that in the natural salt march habitat with the current cultivation method of applying fresh water-irrigation under an inland environment. This work represents the first report of in vitro propagation of sea-milkwort. Thus, our study will contribute to exo-habitat conservation and natural habitat restoration of this endangered species in addition to development of a horticultural product.

Analysis on Probable Rainfall Intensity in Kyungpook Province (경북지방(慶北地方)의 확률(確率) 강우강도(降雨强度)에 대(對)한 분석(分析))

  • Suh, Seung Duk;Park, Seung Young
    • Current Research on Agriculture and Life Sciences
    • /
    • v.4
    • /
    • pp.77-86
    • /
    • 1986
  • The purpose of this study is to estimate an optimum formula of rainfall intensity on basis of the characteristics for short period of rainfall duration in Kyungpook province for the design of urban sewerage and small basin drain system. Results studied are as follows; 1. The optimum method for Taegu and Pohang, Iwai's and Gumbel-Chow's method are recommended respectively. 2. The opotimum type of rainfall intensity for these area, $I=\frac{a}{\sqrt{t}+b}$ (Japanese type), is confirmed with 2.52~4.17 and 1.86~4.54 as a standard deviation for Taegu and Pohang respectively. The optimum formula of rainfall intensity are as follows. Taegu : T : 200 year - $I=\frac{824}{\sqrt{t}+1.5414}$ T : 100 year - $I=\frac{751}{\sqrt{t}+1.4902}$ T : 50 year - $I=\frac{678}{\sqrt{t}+1.4437}$ T : 30 year - $I=\frac{623}{\sqrt{t}+1.4017}$ T : 20 year - $I=\frac{580}{\sqrt{t}+1.3721}$ T : 10 year - $I=\frac{502}{\sqrt{t}+1.3145}$ T : 5 year - $I=\frac{418}{\sqrt{t}+1.2515}$ Pohang : T : 200 year - $I=\frac{468}{\sqrt{t}+1.1468}$ T : 100 year - $I=\frac{429}{\sqrt{t}+1.1605}$ T : 50 year - $I=\frac{391}{\sqrt{t}+1.1852}$ T : 30 year - $I=\frac{362}{\sqrt{t}+1.2033}$ T : 20 year - $I=\frac{339}{\sqrt{t}+1.2229}$ T : 10 year - $I=\frac{299}{\sqrt{t}+1.2578}$ T : 5 year - $I=\frac{257}{\sqrt{t}+1.3026}$ 3. Significant I.D.F. curves derived should be applied to estimate a suitable rainfall intensity and rainfall duration.

  • PDF

The Integer Number Divider Using Improved Reciprocal Algorithm (개선된 역수 알고리즘을 사용한 정수 나눗셈기)

  • Song, Hong-Bok;Park, Chang-Soo;Cho, Gyeong-Yeon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.7
    • /
    • pp.1218-1226
    • /
    • 2008
  • With the development of semiconductor integrated technology and with the increasing use of multimedia functions in computer, more functions have been implemented as hardware. Nowadays, most microprocessors beyond 32 bits generally implement an integer multiplier as hardware. However, as for a divider, only specific microprocessor implements traditional SRT algorithm as hardware due to complexity of implementation and slow speed. This paper suggested an algorithm that uses a multiplier, 'w bit $\times$ w bit = 2w bit', to process $\frac{N}{D}$ integer division. That is, the reciprocal number D is first calculated, and then multiply dividend N to process integer division. In this paper, when the divisor D is '$D=0.d{\times}2^L$, 0.5 < 0.d < 1.0', approximate value of ' $\frac{1}{D}$', '$1.g{\times}2^{-L}$', which satisfies ' $0.d{\times}1.g=1+e$, $e<2^{-w}$', is defined as over reciprocal number and then an algorithm for over reciprocal number is suggested. This algorithm multiplies over reciprocal number '$01.g{\times}2^{-L}$' by dividend N to process $\frac{N}{D}$ integer division. The algorithm suggested in this paper doesn't require additional revision, because it can calculate correct reciprocal number. In addition, this algorithm uses only multiplier, so additional hardware for division is not required to implement microprocessor. Also, it shows faster speed than the conventional SRT algorithm and performs operation by word unit, accordingly it is more suitable to make compiler than the existing division algorithm. In conclusion, results from this study could be used widely for implementation SOC(System on Chip) and etc. which has been restricted to microprocessor and size of the hardware.

Study of Factors Controlling Exposure Dose and Image Quality of C-arm in Operation Room according to Detector Size of It (Mainly L-Spine AP Study) (수술 중 C-Arm Neutral AP 검사 시 조절인자에 따른 피폭선량 및 화질비교(L-Spine AP검사를 기준으로))

  • CHOI, Sung-Hyun;JO, Hwang-Woo;Dong, Kyung-Rae;Chung, Woon-Kwan;Choi, Eun-Jin;Song, Ha-jin
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.85-90
    • /
    • 2015
  • Purpose: Time of operation has been reduced and accuracy of operation has been improved since C-arm, which offer real-time image of patient, was introduced in operation room. However, because of the contamination of patient, C-arm could not be used more appropriately. Therefore, this study is to know factors of controlling exposure dose, image quality and the exposed dose of health professional in operation room. Materials and methods: Height of Wilson frame (bed for operation) was fixed at 130 cm. Then, Model 76-2 Phantom, which was set by assembling manual of Fluke Company, was set on the bed. Head/Spine Fluoroscopy AEC mode was set for exposure condition. According to detector size of C-arm, the absorbed dose per min was measured in the 7 steps OFD (cm) from 10 cm to 40 cm (10, 15, 20, 25, 30, 35, 40 cm). In each step of OFD, the absorbed dose per min of same diameter of collimation was measured. Moreover, using Nero MAX Model 8000, exposure dose per min was measured according to 3 step of distance from detector (20 cm, 60 cm, 100 cm). Finally, resolution was measured by CDRH Disc Phantom and magnification of each OFD was measured by aluminum stick bar. Result: According to detector size of C-arm, difference of absorbed dose shows that the dose of 20 cm OFD is 1.750 times higher than the dose of 40 cm OFD. It means that the C-arm, which has smaller size of detector, shows the bigger difference of absorbed dose per min (p<0.05). In the difference of absorbed dose in the same step of OFD (from 20 cm to 40 cm), the absorbed dose of 9 inch detect or C-arm was 1.370 times higher than 12 inch' s (p<0.05). When OFD was set to 20 cm OFD, the absorbed dose of non-collimation case was approximately 0.816 times lower than the absorbed dose of collimation cases (p<0.05). When the distance was 20 cm from detector, exposed does includes first-ray and scatter-ray. When the distance was 60 cm and 100 cm from detector, exposed does includes just scatter-ray. So, there was the 2.200 times difference of absorbed does. Finally, when OFD was increased, spatial resolution was 4 to 5 step was increased. However, low contrast resolution was not relative. Moreover, there was 1.363 times difference of magnification (p<0.05). Conclusion: When C-Arm is used, avoiding contamination of patient is more important factor than reducing exposed dose of health professional in operation room. Just controlling exposure time is just way to reduce the exposed does of workers. However, in the case, non-probability influence could be occurred. Therefore, this study proved that the exposed dose will be reduced if the factors such as using small detector size of C-arm, setting OFD from 20 cm to 25 cm and non-collimating. Moreover, dose management of C-arm in the non-interesting area will be considered additionally.

Optimum Pre-treatment Method in Constructed Wetlands by Natural Purification Method for Treating Livestock Wastewater (자연정화공법에 의한 인공습지에서 효과적인 축산폐수처리를 위한 최적 전처리방법 구명)

  • Park, Jong-Hwan;Seo, Dong-Cheol;Kim, Ah-Reum;Kim, Sung-Hun;Lee, Seong-Tea;Jeong, Tae-Uk;Choi, Jeong-Ho;Lee, Sang-Won;Cho, Ju-Sik;Kim, Hyun-Ook;Heo, Jong-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.3
    • /
    • pp.425-433
    • /
    • 2011
  • In order to obtain optimum pre-treatment methods and improve T-N and T-P removal efficiencies, removal rates of pollutants in small-scale livestock wastewater treatment apparatus with water plant filtration bed or activated sludge tank were investigated. Based on the results from the optimum pre-treatment in small-scale livestock wastewater treatment apparatus, removal efficiencies of pollutants in livestock wastewater treatment plant with water plant filtration and activated sludge beds. The removal rates of COD, SS, T-N, and T-P in effluent were 83, 89, 63 and 87% in small-scale livestock wastewater treatment apparatus with water plant filtration bed, respectively. The removal rates of COD, SS, T-N, and T-P in effluent were 96, 95, 86 and 92% in small-scale livestock wastewater treatment apparatus with activated sludge tank, respectively. For increasing the COD, SS, T-N, and T-P removals in small-scale livestock wastewater treatment apparatus, the water plant filtration and activated sludge beds are recommended. In livestock wastewater treatment plant with water plant filtration ($1^{st}$ treatment) and activated sludge ($2^{nd}$ treatment) beds, the concentrations of COD, SS, T-N, and T-P in effluent were 39, 15, 42 and $1mg\;L^{-1}$, respectively. It was shown that the concentrations of COD, SS, T-N, and T-P met acceptable effluent quality standard for livestock wastewater. Based on the above results, the removal rates of COD, SS, T-N, and T-P in effluent were over 99.8, 99.9, 99.2, and 99.9% in livestock wastewater treatment plant, respectively.

A Study on the Improvement of Treatment Efficiency for Nitrogen and Phosphorus in Livestock Treatment System Using Constructed Wetlands (인공습지 축산폐수처리시스템에서 질소 및 인 처리효율 향상 방안)

  • Seo, Dong-Cheol;Park, Jong-Hwan;Kim, Ah-Reum;Kim, Sung-Hun;Lee, Seong-Tea;Jeong, Tae-Uk;Choi, Jeong-Ho;Lee, Sang-Won;Kim, Hyun-Ook;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.3
    • /
    • pp.434-441
    • /
    • 2011
  • To improve T-N and T-P removal efficiencies, removal efficiencies of pollutants in full-scale livestock wastewater treatment plant by natural purification method with water plant filtration and activated sludge beds were investigated under different re-injection rates and injection methods of livestock wastewater. The removal rates of COD, SS, T-N, and T-P in effluent in full-scale livestock wastewater treatment plant were in the order of 30% < 70% ${\leq}$ 100 % at different re-injection rates. The removal rates of pollutants in effluent in full-scale livestock wastewater treatment plant were higher as re-injection rate of livestock wastewater increased. Removal rates of COD, SS, T-N, and T-P by continuous injection were slightly higher than those by intermittent injection method in full-scale livestock wastewater treatment plant. Removal rates of COD, SS, T-N, and T-P by continuous injection method in full-scale livestock wastewater treatment plant with water plant filtration and activated sludge beds were 99.5, 99.8, 99.0 and 99.8%, respectively.