• Title/Summary/Keyword: engineering parameters

Search Result 23,277, Processing Time 0.051 seconds

Frequency Characteristics of Anodic Oxide Films: Effects of Anodization Valtage

  • Lee, Dong-Nyung;Yoon, Young-Ku
    • Nuclear Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.14-22
    • /
    • 1974
  • Effects of anodization voltage on frequency characteristics of anodic oxide films on tantalum were analyzed based on the following impedance equatious : (equation omitted) Here $R_{f}$, $C_{f}$ and tan $\delta$$_{f}$ are equivalent series resistance in ohm, equivalent Belies capacitance in farad and dielectric loss, of anodic oxide films respectively Parameters P, $\tau$$_{ο}$, $\tau$$_{\omega}$, and Co are defined as follows: P=(d-w)/w, $\tau$$_{ο}$=$textsc{k}$$\rho$$_{ο}$, $\tau$$_{\omega}$=$textsc{k}$$\rho$$_{\omega}$, $C_{ο}$=$textsc{k}$A/d where d is the thickness of oxide film, $\omega$ is the diffusion layer thickness. $\rho$$_{ο}$ is the resistivity of oxide film at the interface of metal and the oxide, $\rho$$_{\omega}$ is the resistivity of oxide film at intrinsic region and A is the area of the film and $textsc{k}$=0.0885$\times$10$^{-12}$ $\times$dielectric constant, (in farad/cm). It was shown that dielectric loss and frequency dependence of equivalent series capacitance decrease as anodization voltage increases. This is a consequence of the fact that the thickness of diffusion layer increases a little with increasing anodization voltage whereas the total oxide thickness is proportional to the anodization voltage. The ngative deviation of measured values from tile relation, tan $\delta$$_{f}$=0.682 $\Delta$ $C_{f}$, was also discussed based on the Impedance equations given above. Here $\Delta$ $C_{f}$ is the change in capacitance between 0.1 and 1 KHZ.KHZ.Z.

  • PDF

Experimental Investigation of the Combined Effects of Heat Exchanger Geometries on Nucleate Pool Boiling Heat Transfer in a Scaled IRWST (열교환기 형상이 축소한 IRWST 내부의 풀핵비등에 미치는 복합적인 영향에 대한 실험적 연구)

  • Kang, Myeong-Gie;Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.1-16
    • /
    • 1996
  • In an effort to determine the combined effects of major parameters of heat exchanger tubes on the nucleate pool boiling heat transfer in the scaled in-containment refueling water storage tank (IRWST), a total of 1,966 data for q'quot; versus ${\Delta}T$ has been obtained using various combinations of tube diameters, surface roughness, and tube orientations. The experimental results show that (1) increased surface roughness enhances heat transfer for both horizontal and vertical tubes, (2) the two heat transfer mechanisms, i.e.,enhanced heat transfer for both horizontal and vertical tubes, (2) the two heat transfer mechanisms, i.e., enhanced heat transfer due to liquid agitation by bubbles generated and reduced heat transfer by the formation of large vapor slugs and bubble coalescence are different in two regions of low heat fluxes (q'quot; $\leq$50kW/$m^2)$ and high heat fluxes (q'quot; $\geq$50kW/$m^2)$ depending on the orientation of tubes and the degree of surface roughness, and (3) the heat transfer rate decreases as the tube diameter is increased for both horizontal and vertical tubes, but the effect of tube diameter on the nucleate pool boiling heat transfer for vertical tubes is greater than that for horizontal tubes. Two empirical heat transfer correlations for q'quot;, one for horizontal tubes and the other for vertical tubes, are obtained in terms of surface roughness $({\varepsilon})$ and tube diameter (D). In addition, a simple empirical correlation for nucleate pool boiling heat transfer coefficient $(h_b)$ is obtained as a function of heat flux (q'quot;) only.ucleate pool boiling heat transfer coefficient $(h_b)$ is obtained as a function of heat flux (q'quot;) only.

  • PDF

Optimal Sampling Period of the Digital Control System for the Nuclear Power Plant Steam Generator Water Level Control (증기발생기 수위 제어를 위한 디지탈 제어기의 적정 샘플링 주기)

  • Hur, Woo-Sung;Seong, Poong-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.27 no.1
    • /
    • pp.8-17
    • /
    • 1995
  • A great effort has been made to improve the nuclear plant control system by use of digital technologies, and a long term schedule for the control system upgrade has been prepared with an aim to implementation in the next generation nuclear plane. In case of digital control system, it is important to decide the sampling period for analysis and design of the system, because the performance and the stability of a digital control system depend on the value of the sampling period of the digital control system. There is, however, currently no systematic method used universally for determining the sampling period of the digital control system. Generally, a traditional way to select the sampling frequency is to use 20 to 30 times the bandwidth of the analog control system which has the same system configuration and parameters as the digital one. In this paper, a new method to select the sampling period is suggested which takes into account of the performance as well as the stability of the digital control system. By use of the frying's model of steam generator, the optimal sampling period of an assumptive digital control system for steam generator level control is estimated and is actually verified in the digital control simulation system for KORI-2 nuclear power plant steam generator level control. Consequently, we conclude the optimal sampling period of the digital control system for KORI-2 nuclear power plant steam generator level control is 1 second for all power ranges.

  • PDF

Life Cycle Impact Assessment to Corn Field Appling Anaerobic and Aerobic Digestates Including Each Swine Waste Treatment System (돈분처리 시스템을 포함한 액비 시용에 따른 옥수수 재배과정에 대한 전과정 환경영향 평가)

  • Shin, Joung-Du;Lee, Sun-Il;Park, Woo-Kyun;Choi, Yong-Su;Na, Young-Eun;Park, Yoo-Sung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.2
    • /
    • pp.35-43
    • /
    • 2014
  • The application of the Life Cycle Impact Assessment (LCIA) methodology to analyze the environmental burden of appling the digestates to corn field including different swine waste treatment systems was investigated. The first part of LCA is an inventory of parameters used to emissions released due to the system under investigation. In the following step, the Life Cycle Impact Assessment, the inventory data were analyzed and aggregated in order to finally get one index representing the each environmental burden. Each corn field applied with the aerobic and anaerobic digestates including different swine waste treatment systems was used as an example for the life cycle impact analysis. With analyzing the agricultural environmental burden, it observed that the effect of corn field applied aerobic digestate including digestion system was 7.6 times higher at eutrophication effects, but global warming potential effect was 0.9 times less than its applied anaerobic digestate.

Clip-type Binding Implement Effect on Anchorage Behavior of 90-Degree End-Hooked Transverse Reinforcement in Reinforced Concrete Columns (클립형 연결장치로 결속된 90도 갈고리를 갖는 띠철근의 정착거동)

  • Park, Kyoung-Yeon;Yun, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.4
    • /
    • pp.72-80
    • /
    • 2020
  • The purpose of this study is to secure the same or more structural performance and constructability for the details of hooks cross-constructed at 135 degrees used as external-ties standard detail in RC columns, therefore, to the purpose of improving constructability, the clip-type binding implement was suggested and A total of 28 pull-out specimens were prepared with the parameters of concrete compressive strength and clip-embeded length, clip installation location to examine the anchorage behavior of the clip-type binding implement. The experiment was carried out. The results of the experiment confirmed that the anchorage strength of the clip-type binding implement was higher than the details of hooks cross-constructed at 135-degree regardless of the diameter of tie and concrete strength, embeded clip length, clip installation. and The 90-degree end hook with clip-type binding implement was showed a similar an anchorage behavior of 135-degree end-hooked transverse reinforcement, consequently, The 90-degree end hooked with clip-type binding implement is evaluated to be the same anchorage behavior and performance as standard 135-degree end hook detail.

Extraction of Renal Glomeruli Region using Genetic Algorithm (유전적 알고리듬을 이용한 신장 사구체 영역의 추출)

  • Kim, Eung-Kyeu
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.2
    • /
    • pp.30-39
    • /
    • 2009
  • Extraction of glomeruli region plays a very important role for diagnosing nephritis automatically. However, it is not easy to extract glomeruli region correctly because the difference between glomeruli region and other region is not obvious, simultaneously unevennesses that is brought in the sampling process and in the imaging process. In this study, a new method for extracting renal glomeruli region using genetic algorithm is proposed. The first, low and high resolution images are obtained by using Laplacian-Gaussian filter with ${\sigma}=2.1$ and ${\sigma}=1.8$, then, binary images by setting the threshold value to zero are obtained. And then border edge is detected from low resolution images, the border of glomeruli is expressed by a closed B-splines' curve line. The parameters that decide the closed curve line with this low resolution image prevent the noises and the border lines from breaking off in the middle by searching using genetic algorithm. Next, in order to obtain more precise border edges of glomeruli, the number of node points is increased and corrected in order from eight to sixteen and thirty two from high resolution images. Finally, the validity of this proposed method is shown to be effective by applying to the real images.

Structural Performance of Pre-tensioned Half-depth Precast Panels (프리텐션 반두께 바닥판을 갖는 바닥판의 구조성능 평가)

  • Kim, Dong Wook;Shim, Chang Su
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.6
    • /
    • pp.1707-1721
    • /
    • 2014
  • Half-depth panels were developed with the merits of CIP (Cast In Place) decks and precast decks for constructability and fast construction. In this paper, details of half-depth panels with pre-tensioning were suggested. For evaluation of structural performance, five half-depth panel specimens were fabricated and static tests were conducted. The cross-sections of these specimens were composed of pre-tensioned half-depth panels and pre-tensioned two-span half-depth panels. Test parameters were the amount of the prestressing force and the longitudinal reinforcements. Static tests on simply-supported slabs showed that ultimate strength was 1.55 times greater than calculated nominal strength. The flexural strength was only 10 % increased and the influence on crack width control was negligible when the member of tendons was increased twice. For two-span continuous specimens, the ultimate strength increased 1.2 times and 1.38 times respectively as the reinforcement was additionally provided. The verified half-depth panels by this research can be effectively utilized for the fast replacement or construction of bridges.

Mechanical Properties and Stress-Strain Model of Re-Bars Coldly Bent and Straightened (굽힌 후 편 철근의 기계적 성질과 응력-변형률 모델)

  • Chun, Sung-Chul;Tak, So-Young;Ha, Tae-Hun
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.2
    • /
    • pp.195-204
    • /
    • 2012
  • In the construction of high-rise buildings, bent re-bars are manually straightened to connect slabs to core-walls, which are usually cast before floor structures. During cold bending and straightening of re-bars, plastic deformation causing work hardening, Bauschinger effect and aging hardening is unavoidable. Tensile tests of coldly bent and straightened re-bars were conducted with test parameters of grade, diameter, and bend radius of re-bars as well as age between bending and straightening. Test results showed that proportional limits were lower and strain hardening occurred without yield plateaus. Inside and outside of re-bars with compression and tension deformations, respectively, during bending showed lower yield points due to Bauschinger effect and no yield plateaus due to work hardening, respectively. When re-bar grade was higher, yield point became significantly lower where Grade 400 re-bars had yield strengths lower than specified yield strength of 400 MPa. Because the surface of re-bar has higher strength than the core of re-bar, Bauschinger effect was more obvious for higher-grade re-bars. When age between bending and straightening was greater, yield strength increased and elongation decreased (i.e. embrittlement occurs). Using measured data, stress-strain relationship for straightened re-bars was developed based on Ramberg-Osgood model, which can be used to evaluate stiffness of joints when straightened re-bars are applied.

Strength Development of Blended Sodium Alkali-Activated Ground Granulated Blast-Furnace Slag (GGBS) Mortar (혼합된 나트륨계열 활성화제에 의한 고로슬래그 기반 모르타르의 강도발현 특성)

  • Kim, Geon-Woo;Kim, Byeong-Jo;Yang, Keun-Hyeok;Song, Jin-Kyu
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.2
    • /
    • pp.137-145
    • /
    • 2012
  • Strength model for blasted furnace slag mortar blended with sodium was investigated in this study. The main parameters of AAS (alkali activated slag) mortar were dosage of alkali activator, water to binder ratio (W/B), and aggregate to binder ratio (A/B). For evaluating the property related to the dosage of alkali activator, sodium carbonate ($Na_2CO_3$) of 4~8% was added to 4% dosage of sodium hydroxide (NaOH). W/B and A/B was varied 0.45~0.60 and 2.05~2.85, respectively. An alkali quality coefficient combining the amounts of main compositions of source materials and sodium oxide ($Na_2O$) in sodium hydroxide and sodium carbonate is proposed to assess the compressive strength of alkali activated mortars. Test results clearly showed that the compressive strength development of alkali-activated mortars were significantly dependent on the proposed alkali quality coefficient. Compressive strength development of AAS mortars were also estimated using the formula specified in the previous study, which was calibrated using the collected database. Predictions from the simplified equations showed good agreements with the test results.

A dose monitoring system for dental radiography

  • Lee, Chena;Lee, Sam-Sun;Kim, Jo-Eun;Symkhampha, Khanthaly;Lee, Woo-Jin;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Yeom, Heon-Young
    • Imaging Science in Dentistry
    • /
    • v.46 no.2
    • /
    • pp.103-108
    • /
    • 2016
  • Purpose: The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. Materials and Methods: An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. Results: The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. Conclusion: A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.