• Title/Summary/Keyword: energy consumption reduction

Search Result 774, Processing Time 0.025 seconds

Estimation of Carbon Emissions and Energy Self-Sufficiency in Sewage Treatment plant's Improvement by using Life Cycle Management Tool (LCM 기법을 이용한 하수처리장 개선에 따른 탄소배출량 및 에너지 자립율 평가)

  • Moon, Jin-Young;Park, Ji-Hyoung;Hwang, Yong-Woo;Park, Kwang-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.2
    • /
    • pp.223-232
    • /
    • 2013
  • In this study, carbon emissions and energy consumption were evaluated to establish a design strategy which has low energy consumption and carbon emission production, by using life cycle energy (LCE) and life cycle $CO_2(LCCO_2)$ calculation methods in life cycle management(LCM) tools. After improvement design projects, the energy consumption and $CO_2$ emission were calculated and compared in three sewage treatment plants (STPs), which are A STP, B STP, and C STP. The reduction of carbon emissions was 28,020.1 ton $CO_{2-}e/yr$, 37,399.6 ton $CO_{2-}e/yr$ and 8,788.3 ton $CO_{2-}e/yr$, respectively. Production of energy was 792 TOE/yr, 1,235 TOE/yr and 1,023 TOE/yr, respectively. As a result, the estimation of energy and energy self-sufficiency was 5.1 %, 14.5 % and 23.5 %, respectively. The result of this study shows the LCM can be contributed to establish strategy for energy and carbon emission reduction in sewage treatment plants.

Cautious View on Network Coding - From Theory to Practice

  • Heide, Janus;Pedersen, Morten V.;Fitzek, Frank H.P.;Larsen, Torben
    • Journal of Communications and Networks
    • /
    • v.10 no.4
    • /
    • pp.403-411
    • /
    • 2008
  • Energy consumption has been mostly neglected in network coding (NC) research so far. This work investigates several different properties of NC that influence the energy consumption and thus are important when designing NC systems for battery-driven devices. Different approaches to the necessary implementation of coding operations and Galois fields arithmetic are considered and complexity expressions for coding operations are provided. We also benchmark our own mobile phone implementation on a Nokia N95 under different settings. Several NC strategies are described and compared, furthermore expressions for transmission times are developed. It is also shown that the use of NC introduces a trade off between reduction in transmission time and increase in energy consumption.

A Study on Energy Reduction of Passive Factor Apply for the Improvement of Energy Performance in Public Building (공공기관 건물의 에너지 성능개선을 위한 패시브 요소 적용의 에너지 절감율 분석 연구)

  • Son, Ji-Hoon;Kim, Sam-Uel
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.196-201
    • /
    • 2011
  • The energy used in Korea is strongly dependent on that produced by foreign countries. Accordingly, saving energy is more important than ever, because of the rise of international oil prices and depletion of oil resources. The development of energy efficient buildings is required especially for public buildings in Korea. In this study, the energy use of public buildings is identify. Then, the analysis of energy usage through regional offices in Busan City offers energy performance for public buildings.

  • PDF

A Study on the Effects of Oil Shocks and Energy Efficient Consumption Structure with a Bayesian DSGE Model (베이지안 동태확률일반균형모형을 이용한 유가충격 및 에너지 소비구조 전환의 효과분석)

  • Cha, Kyungsoo
    • Environmental and Resource Economics Review
    • /
    • v.19 no.2
    • /
    • pp.215-242
    • /
    • 2010
  • This study constructs a bayesian neoclassical DSGE model that applies oil usage. The model includes technology shocks, oil price shocks, and shocks to energy policies as exogenous driving forces. First, this study aims to analyze the roles of these exogenous shocks in the Korean business cycle. Second, this study examines the effects of long-term changes in the energy consumption structure, including the reduction in oil use as a share of energy consumption and improvement in oil efficiency. In the case of oil price shocks, results show that these shocks exert recessionary pressure on the economy in line with those obtained in the previous literature. On the other hand, shocks to energy policies, which reduce oil consumption per capital, result in opposite consequences to oil price shocks, decreasing oil consumption. Also, counterfactual exercises show that long-term changes in the energy consumption structure would mitigate the contractionary effects of oil price shocks.

  • PDF

Case Studies of Energy-Saving Method for Renewable Energy Installation in Sewage Treatment plant (하수처리장 신재생에너지 설치 사례 연구를 통한 에너지 절감 방안)

  • Yoon, Jong-Won;Kim, Chu-Young;Choi, Chang-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.42-48
    • /
    • 2014
  • Sewage treatment facilities can purify sewage enough to be send to river or sea water, that discharged from human life and industrial activities. In the sewage treatment process, we can get large amount of by-product energy resources and materials such as heat of sewage, digester gas and purified water etc., it can be utilized by applying various technologies thereby we can reduce energy consumption in the process. In this paper, it was analyzed using the data collected from the operational case study for the energy savings effect that can be obtained when using the digester gas, one of the by-product materials of sewage treatment process, for electric power generation. Cost of 623million won is an annual reduction of 4,032MWh corresponding 9% of the annual electricity consumption of the sewage treatment plant, such an alternative power generation using digester gas was proposed in this paper has been verified the feasibility of the proposed reduction of energy.

Assessment for the effect of heating systems on the energy consumption and environment (개별난방과 지역난방방식의 에너지절감 및 환경개선효과 분석)

  • Im, Yong-Hoon;Kim, Hyouck-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.466-473
    • /
    • 2007
  • The comparison for the performance of heating systems, district heating and separate heating and power, is carried out in terms of energy consumption and environment on the basis of real operating data. The efficiency of boiler and the heat loss within the housing are assumed with reasonable manner due to the lack of reliable data regarding those quantities. The assessment for the established criteria of previous studies is performed and the new criteria for the analysis is proposed. It is shown that the district heating system is superior to the separate heating and power system from the point of view of reduction of energy use and environment improvement. The sensitivity study for those quantities with uncertainty such as the boiler efficiency and heat loss within the housing is carried out also and the reasons for the analysis results are discussed in detail.

  • PDF

Analysis of the Relationships among Energy, Economic Growth and Greenhouse Gas Emissions Using Metropolitan City/Province Level Data (광역시·도별 자료를 이용한 에너지, 경제성장, 온실가스 배출 간의 관계 분석)

  • Lee, Jaeseok;Lee, Keun-Dae;Yu, Bok-Keun
    • Environmental and Resource Economics Review
    • /
    • v.30 no.3
    • /
    • pp.503-533
    • /
    • 2021
  • This paper analyzes the relationships among the energy consumption, renewable energy production, real gross regional domestic product(GRDP), and greenhouse gas(GHG) emissions. It uses the metropolitan city and province level data for Korea from 2010 to 2018, employing a panal vector autoregressive(VAR) model. We find that an increase in energy consumption has a limited impact on boosting renewable energy production or gross regional domestic product, while it leads to an increase in greenhouse gas emissions. A rise in renewable energy production can increase gross regional domestic product, but it has no meaningful effects on energy consumption and the reduction of green house gas emissions. Our finding indicates that it is crucial to expand the supply of renewable energy as well as to decrease energy consumption in order to achieve the goal of reducing greenhouse gas emissions and reaching economic growth.

A Study on Energy Reduction in an Outdoor Air Conditioning System for Semiconductor Manufacturing Cleanrooms Using Water Spray Humidification (반도체 클린룸용 외기공조시스템의 수분무 가습을 이용한 에너지절감에 관한 연구)

  • Song, Won-Il;Kim, Ki-Cheol;Yoo, Kyung-Hoon;Shin, Dae-Kun;Tae, Kyung-Eung;Kim, Yong-Sik;Park, Dug-Jun
    • Particle and aerosol research
    • /
    • v.13 no.2
    • /
    • pp.65-77
    • /
    • 2017
  • In recent large-scale semiconductor manufacturing cleanrooms, the energy consumption in outdoor air conditioning (OAC) systems to heat, humidify, cool and dehumidify outdoor air(OA) represents about 40~50 % of the total cleanroom power consumption required to maintain cleanroom environment. Therefore, the assessment of energy consumption in outdoor air conditioning systems is essential for reducing the outdoor air conditioning load for a cleanroom. In the present study, an experiment with an outdoor air flow rate of $1,000m^3/h$ was conducted to compare the energy consumption in steam humidification, simple air washer, exhaust air heat recovery type air washer and dry cooling coil(DCC) return water heat recovery type air washer OAC systems. Besides, a numerical analysis was carried out to evaluate the annual energy consumption of the aforementioned four OAC systems. It was shown that the simple air washer, exhaust air heat recovery type air washer and DCC return water heat recovery type air washer OAC systems using water spray humidification were more energy-efficient than the steam humidification OAC system. Furthermore the DCC return water heat recovery type air washer OAC system was the most energy-efficient.

A Study of Energy Saving Hydraulic System by A Pressure Coupling Hydrostatic Transmission (압력커플링 정유압 변속기를 이용한 에너지 절감 유압시스템에 관한 연구)

  • Do, H.T.;Ahn, K.K.
    • Journal of Drive and Control
    • /
    • v.9 no.1
    • /
    • pp.10-17
    • /
    • 2012
  • Nowadays, the demand of energy saving is increasing more and more while the natural resources have been exhausted. Besides, the emission gas caused by vehicles has been being a serious environment problem. Therefore, many studies have been carried out, especially focusing on braking energy regeneration, in order to save energy as well as reduce emission of mobile vehicles. In this paper, we propose a closed-loop hydrostatic transmission for braking energy regeneration with two configurations to reduce the energy consumption by recovering the braking energy. The effectiveness of the proposed system was verified by simulation. The simulation results indicated that the pressure coupling configuration gave better performance in comparison to flow coupling configuration about 40.8%, 61.7% and 53.8% reduction of fuel consumption in 10 mode, 10 mode modified profile and highway schedules, respectively.

Comparative Analysis on the Heating and Cooling Loads Associated with U-value, SHGC and Orientation of the Windows in Different Regions (창호의 열관류율, 일사취득계수와 향의 배치가 건물의 냉난방 부하에 미치는 영향에 관한 지역별 비교연구)

  • Choi, Min-Seo;Chang, Seong-Ju
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.123-130
    • /
    • 2013
  • The primary goal of this research is to identify the impacts of window design on the energy use in buildings which takes up about 25% of the total energy consumption. Recently, efficient use of energy is gaining more importance in buildings. Window design, especially being dependent on glazing performance choices, is an important factor for reducing energy consumption in most of the buildings. It also is influenced by the latitude of the site and window orientation. This paper aims at identifying the influence of Window performance indicators(U-value, SHGC), orientation and latitude on the building energy consumption with systematically designed simulations. Comparative study has been performed for five different locations; Greenland, Korea, Singapore, Argentina and Chile along with the different window U-value and SHGC values. The results show that optimum window system with properly coordinated window performance indicators(U-value, SHGC), orientation achieves dramatic reduction of energy consumptions. Windows with low U-value could reduce heating loads and high SHGC could reduce cooling loads. The study also verifies that the windows installed at south facade is more energy efficient in the northern hemisphere while windows facing north is more energy efficient in the southern hemisphere.