• Title/Summary/Keyword: energy based methods

Search Result 2,354, Processing Time 0.032 seconds

A Study on Mutual Aid and Mutual Contention of the Ten Celestial Stems and Twelve Earthly Branches (천간과 지지의 상조(相助)와 상극(相剋)에 관한 연구)

  • Woo Yeon-hwa;Kim Man-tae
    • Journal of the Daesoon Academy of Sciences
    • /
    • v.42
    • /
    • pp.109-141
    • /
    • 2022
  • As many perhaps already know, in East Asian thought there are two aspects of all things such as light and darkness coexist and are called Yin-Yang (陰陽). The initial concept of Yin-Yang was just a simple expression meant to depict natural phenomena, but it gradually became the central concept in explanations of creation and the changes that undergo all things in the universe. The study of the ordering principle of nature that was known as Myeongli (命理) also examined the interrelation between the sky and the earth and divided the two into Ten Celestial Stems (天干 cheongan) and the Twelve Earth Branches (地支 jiji) based on Yin-Yang theory. This thesis analyzed contents of the relationship between Ten Celestial Stems and the Twelve Earth Branches in terms of the patterns of Mutual Aid (相助 sangjo) and Mutual Contention (相剋 sanggeuk) through a literature review and exploration of their common features and differences. Different categorized phenomena under the pattern of Mutual Aid include Tonggeun (通根 root downward) and Tugan (透干 appearance of the upward). Tonggeun means that signs in the Celestial Stems took root in their counterparts of the Earthly Branches. In the Celestial Stems, there is also Tonggeuncheo (通根處 a place to root downward) which in relation to the Earthly Branches show that the same five phases become Samhap (三合 combined three ways to gain power) and Banghap (方合 gathering in the same season). The methods of seeing Tonggeunryeok (通根力 power of a downward root) are as follows: First, it is seen by the places where Tonggeun takes hold. Ilgan (日干 the Celestial Stem of a birthday) is ordered as month (月 wol) > day (日 il) > hour (時 shi) > year (年 nyeon), and other Celestial Stems appear ordered as month > sitting > close place. Second, it can be seen by the characteristics of Earthly Branches that Tonggeun has taken hold. The Earthly Branches are ordered as Rokwangji (祿旺支 vigorous land) and Jangsaengji (長生支 newborn land) > Yeogi (餘氣 remaining energy) > Myogo (墓庫 storage and burial grounds). Tugan is the concept that the main agent was changed to Tonggeun, which means that the spirit of the Earthly Branches is manifested in the Celestial Stems. And the five phases hidden in the Earthly Branches will be able to play their roles as they are revealed. There are also the phenomena of Gaedu (蓋頭 the heavenly destroying the earthly) and Jeolgak (截脚 the earthly destroying the heavenly) which are concepts that convey that the Heavenly Stems and Earthly Branches can mutually destroy one another. There are different opinions on Gaedu because some adopt viewpoints of just focusing on the Celestial Stems and considering it only in terms the Celestial Stems destroying the Earthly Branches. But, the vast majority of scholars think that the Celestial Stems weakens the role of the roots by destroying the Earthly Branches. Jeolgak, the reverse concept of Gaedu, weakens the spirit of the Celestial Stems as the Earthly Branches destroy them, and this is associated with the strong possibility that one is fated to experience disharmony.

A prediction model for adolescents' skipping breakfast using the CART algorithm for decision trees: 7th (2016-2018) Korea National Health and Nutrition Examination Survey (의사결정나무 CART 알고리즘을 이용한 청소년 아침결식 예측 모형: 제7기 (2016-2018년) 국민건강영양조사 자료분석)

  • Sun A Choi;Sung Suk Chung;Jeong Ok Rho
    • Journal of Nutrition and Health
    • /
    • v.56 no.3
    • /
    • pp.300-314
    • /
    • 2023
  • Purpose: This study sought to predict the reasons for skipping breakfast by adolescents aged 13-18 years using the 7th Korea National Health and Nutrition Examination Survey (KNHANES). Methods: The participants included 1,024 adolescents. The data were analyzed using a complex-sample t-test, the Rao Scott χ2-test, and the classification and regression tree (CART) algorithm for decision tree analysis with SPSS v. 27.0. The participants were divided into two groups, one regularly eating breakfast and the other skipping it. Results: A total of 579 and 445 study participants were found to be breakfast consumers and breakfast skippers respectively. Breakfast consumers were significantly younger than those who skipped breakfast. In addition, breakfast consumers had a significantly higher frequency of eating dinner, had been taught about nutrition, and had a lower frequency of eating out. The breakfast skippers did so to lose weight. Children who skipped breakfast consumed less energy, carbohydrates, proteins, fats, fiber, cholesterol, vitamin C, vitamin A, calcium, vitamin B1, vitamin B2, phosphorus, sodium, iron, potassium, and niacin than those who consumed breakfast. The best predictor of skipping breakfast was identifying adolescents who sought to control their weight by not eating meals. Other participants who had low and middle-low household incomes, ate dinner 3-4 times a week, were more than 14.5 years old, and ate out once a day showed a higher frequency of skipping breakfast. Conclusion: Based on these results, nutrition education targeted at losing weight correctly and emphasizing the importance of breakfast, especially for adolescents, is required. Moreover, nutrition educators should consider designing and implementing specific action plans to encourage adolescents to improve their breakfast-eating practices by also eating dinner regularly and reducing eating out.

Dietary habits and nutrient intake status of university students according to obesity risk based on body mass index and percent body fat (BMI와 체지방률을 고려한 비만위험도 판정에 따른 대학생의 식생활 및 섭취 양상 연구)

  • Chae Hong Lee;Kyung A Lee
    • Journal of Nutrition and Health
    • /
    • v.56 no.6
    • /
    • pp.714-729
    • /
    • 2023
  • Purpose: Since the coronavirus pandemic, the number of obese people has increased, and accelerated aging has been reported, particularly among young population. Therefore, this study analyzed the dietary habits of university students according to their risk of obesity to provide data for improving their eating habits. Methods: Ninety students at Daegu Catholic University were surveyed for their eating habits and photo-enhanced meal intake. The obesity risk was categorized as normal if the body mass index (BMI) and percent body fat (PBF) were normal, at-risk if both indicated overweight or obese, obesity in BMI alone were analyzed as BMI group and those with obesity in percent body fat alone were analyzed as PBF group. Results: There were 23 (25.5%) in the normal group, 10 (11.1%) in the BMI group, 24 (26.7%) in the PBF group and 33 (36.7%) in the at-risk group. The dietary survey showed that the risk groups had lower consumption frequencies of vegetables (p < 0.05) than the normal group, had less sleep time (p < 0.05) and higher frequency of fast food consumption (p < 0.001). The intake of vegetables was significantly higher in the normal group than in the risk group (p < 0.05). In terms of the daily nutrient intake, there was no significant difference in energy intake according to the obesity risk, but the intakes of dietary fiber (p < 0.01), vitamin A (p < 0.01), vitamin C (p < 0.01) were higher in the normal group than in the risk groups. Conclusion: Therefore, it is important to consider the BMI and percent body fat together to diagnose obesity and provide nutrition education and counseling.

A study on the status of dietary behavior and nutrient intakes according to the gender and the level of physical activity of adolescents: using the 7th (2017-2018) Korea National Health and Nutrition Examination Survey (청소년의 성별과 신체활동 수준에 따른 식행동 및 영양섭취실태: 제7기 2,3차년도 (2017-2018년) 국민건강영양조사 자료 이용)

  • Seo Yeon Kim;Sun A Choi;Jeong Ok Rho
    • Journal of Nutrition and Health
    • /
    • v.56 no.6
    • /
    • pp.683-701
    • /
    • 2023
  • Purpose: The purpose of the study was to analyze the status of dietary behavior and nutrition intakes according to the gender and the level of physical activity of adolescents. Methods: Data from 659 adolescents aged 13 to 18 years who participated in the Korea National Health and Nutrition Examination Survey (2017-2018) were analyzed. Collected data were analyzed using complex sampling data analysis with SPSS v. 27.0. Results: The adolescents were categorized into three groups based on their physical activity as follows: The first group with high physical activity (8.9%), a second group with normal physical activity (29.7%), and a third group without physical activity (61.4%). Boys showed significantly higher physical activity than the girls. Adolescents with high physical activity had a significantly lower body mass index than adolescents without physical activity, but their meal regularity, subjective health status, and recognition of body image were significantly higher. In terms of biochemical factors, adolescents with high physical activity had lower triglycerides and cholesterol than adolescents without physical activity, while hemoglobin and hematocrit were significantly higher. In addition, the intakes of energy, carbohydrates, proteins, fat, vitamin B1, niacin, calcium, phosphorus, sodium, potassium, iron increased significantly as adolescents' physical activity increased. Conclusion: The physical activity of adolescents had a positive effect on dietary behavior, lifestyle, and nutritional factors. Therefore, it is necessary to increase participation in physical classes in schools and develop various programs considering the level of physical activity among adolescents.

Evaluation of the effect of a Position Error of a Customized Si-Bolus Produced using a 3D-Printer: Cervical Cancer Radiation Treatment (3D 프린터를 이용하여 제작한 맞춤형 Si-Bolus의 위치 오차 효과 평가: 자궁경부암 방사선 치료)

  • Seong Pyo Hong;Ji Oh Jeong;Seung Jae Lee;Byung Jin Choi;Chung Mo Kim;Soo Il Jung;Yun Sung Shin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.7-13
    • /
    • 2023
  • Purpose: In this study, we evaluated the effect of using a customized bolus on dose delivery in the treatment plan when cervical cancer protruded out of the body along with the uterus and evaluated reproducibility in patient set-up. Materials & Methods: The treatment plan used the Eclipse Treatment Planning System (Version 15.5.0, Varian, USA) and the treatment machine was VitalBeam (Varian Medical Systems, USA). The radiotherapy technique used 6 MV energy in the AP/PA direction with 3D-CRT. The prescribed dose is 1.8 Gy/fx and the total dose is 50.4 Gy/28 fx. Semiflex TM31010 (PTW, Germany) was used as the ion chamber, and the dose distribution was analyzed and evaluated by comparing the planned and measured dose according to each position movement and the tumor center dose. The first measurement was performed at the center by applying a customized bolus to the phantom, and the measurement was performed while moving in the range of -2 cm to +2 cm in the X, Y, and Z directions from the center assuming a positional error. It was measured at intervals of 0.5 cm, the Y-axis direction was measured up to ±3 cm, and the situation in which Bolus was set-up incorrectly was also measured. The measured doses were compared based on doses corrected to CT Hounsfield Unit (HU) 240 of silicon instead of the phantom's air cavity. Result: The treatment dose distribution was uniform when the customized bolus was used, and there was no significant difference between the prescribed dose and the actual measured value even when positional errors occurred. It was confirmed that the existing sheet-type bolus is difficult to compensate for irregularly shaped tumors protruding outside the body, but customized Bolus is found to be useful in delivering treatment doses uniformly.

  • PDF

Studies of nutrient composition of transitional human milk and estimated intake of nutrients by breast-fed infants in Korean mothers (한국인 수유부의 수유초기 이행유의 모유성분 분석과 영아의 섭취량 추정 연구)

  • Choi, Yun Kyung;Kim, Nayoung;Kim, Ji-Myung;Cho, Mi Sook;Kang, Bong Soo;Kim, Yuri
    • Journal of Nutrition and Health
    • /
    • v.48 no.6
    • /
    • pp.476-487
    • /
    • 2015
  • Purpose: This study was conducted to examine the concentration of nutrients in transitional breast milk from Korean lactating mothers and to evaluate daily intakes of their infants based on the Dietary Reference Intakes for Koreans 2010 (KDRIs 2010). Methods: Breast milk samples were collected at 5~15 days postpartum from 100 healthy lactating Korean mothers. Macro- and micro-nutrients, and immunoglobulin (Igs) concentrations in breast milk were analyzed. Results: The mean energy, protein, fat, and carbohydrate concentrations in breast milk were $59.99{\pm}8.01kcal/dL$, $1.47{\pm}0.27g/dL$, $2.88{\pm}0.89g/dL$, and $6.72{\pm}0.22g/dL$. The mean linoleic acid (LA), a-linolenic acid (ALA), arachidonic acid (AA), and docosahexaenoic acid (DHA) concentrations were $181.44{\pm}96.41mg/dL$, $28.15{\pm}8.89mg/dL$, $5.67{\pm}1.86mg/dL$, and $5.74{\pm}2.57mg/dL$. The mean vitamin A, vitamin D, vitamin E, vitamin $B_1$, vitamin $B_2$, vitamin $B_{12}$, and folate concentrations were $2.75{\pm}1.75{\mu}g/dL$, $2.31{\pm}1.12ng/dL$, $0.74{\pm}1.54mg/dL$, $3.02{\pm}1.84mg/dL$, $7.51{\pm}20.96{\mu}g/dL$, $61.78{\pm}26.78{\mu}g/dL$, $63.71{\pm}27.19ng/dL$, and $0.52{\pm}0.26{\mu}g/dL$. The mean concentrations of calcium, iron, potassium, sodium, zinc, and copper were $20.71{\pm}3.34mg/dL$, $0.59{\pm}0.86mg/dL$, $66.71{\pm}10.35mg/dL$, $27.72{\pm}10.16mg/dL$, $0.44{\pm}0.41mg/dL$, and $70.48{\pm}30.41{\mu}g/dL$. The mean IgA and total IgE concentrations were $61.85{\pm}31.97mg/dL$ and $235.00{\pm}93.00IU/dL$. The estimated daily intakes of infants for protein, vitamin D, vitamin E, vitamin $B_2$, vitamin $B_{12}$, iron, potassium, sodium, zinc, and copper were sufficient compared to KDRIs 2010 adjusted by transitory milk intakes. The estimated infants' intakes of energy, fat, carbohydrate, vitamin A, vitamin C, vitamin $B_1$, folate, and calcium did not meet KDRIs 2010 adjusted by transitory milk intakes. Conclusion: In general most estimated nutrient intakes of Korean breast-fed infants in transitory breast milk were sufficient, however some nutrient intakes were not sufficient based on KDRIs 2010. These results warrant conduct of future studies for investigation of important dietary factors associated with nutrients in breast milk to improve the quality of breast milk, which may contribute to understanding nutrition in early life and promoting growth and development of breast-fed infants.

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

The Benefit of Individualized Custom Bolus in the Postmastectomy Radiation Therapy : Numerical Analysis with 3-D Treatment Planning (유방전절제술 후 방사선치료를 위한 조직보상체 개발 및 3차원 치료계획을 통한 유용성 분석)

  • Cho Jae Ho;Cho Kwang Hwan;Keum Kichang;Han Yongyih;Kim Yong Bae;Chu Sung Sil;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.82-93
    • /
    • 2003
  • Purpose : To reduce the Irradiation dose to the lungs and heart in the case of chest wail irradiation using an oppositional electron beam, we used an Individualized custom bolus, which was precisely designed to compensate for the differences In chest wall thickness. The benefits were evaluated by comparing the normal tissue complication probablilties (NTCPS) and dose statistics both with and without boluses. Materials and Methods : Boluses were made, and their effects evaluated in ten patients treated using the reverse hockey-stick technique. The electron beam energy was determined so as to administer 80% of the irradiation prescription dose to the deepest lung-chest wall border, which was usually located at the internal mammary lymph node chain. An individualized custom bolus was prepared to compensate for a chest wall thinner than the prescription depth by meticulously measuring the chest wall thickness at 1 emf intervals on the planning CT Images. A second planning CT was obtained overlying the individuailzed custom bolus for each patient's chest wall. 3-D treatment planning was peformed using ADAC-Pinnacle$^{3}$ for all patients with and without bolus. NTCPS based on 'the Lyman-Kutcher' model were analyzed and the mean, maximum, minimum doses, V$_{50}$ and V$_{95}$ for 4he heari and lungs were computed. Results .The average NTCPS in the ipsliateral lung showed a statistically significant reduction (p<0.01), from 80.2${\pm}$3.43% to 47.7${\pm}$4.61%, with the use of the individualized custom boluses. The mean lung irradiation dose to the ipsilateral iung was also significantly reduced by about 430 cGy, Trom 2757 cGy to 2,327 cGy (p<0.01). The V$_{50}$ and V$_{95}$ in the ipsilateral lung markedly decreased from the averages of 54.5 and 17.4% to 45.3 and 11.0%, respectively. The V$_{50}$ and V$_{95}$ In the heart also decreased from the averages of 16.8 and 6.1% to 9.8% and 2.2%, respectively. The NTCP In the contralateral lung and the heart were 0%, even for the cases with no bolus because of the small effective mean radiation volume values of 4.4 and 7.1%, respectively Conclusion : The use of an Individualized custom bolus in the radiotherapy of postrnastectorny chest wall reduced the NTCP of the ipsilateral lung by about 24.5 to 40.5%, which can improve the complication free cure probability of breast cancer patients.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

A Retrospective Study of the Radiotherapy Care Patterns for Patients with Laryngeal Cancer and Comparison of Different Korean Hospitals Treated from 1998 through 1999 (한국인 후두암 환자의 방사선치료 과정 및 내용에 관한 분석 (1998~1999년도))

  • Chung, Woong-Ki;Kim, Il-Han;Yoon, Mee-Sun;Ahn, Sung-Ja;Nam, Taek-Keun;Song, Ju-Young;Chung, Jae-Uk;Nah, Byung-Sik;Lee, Joon-Kyoo;Wu, Hong-Gyun;Lee, Chang-Geol;Lee, Sang-Wook;Park, Won;Ahn, Yong-Chan;Kang, Ki-Moon;Kim, Jung-Soo;Oh, Yoon-Kyeong;Cho, Moon-June;Park, Woo-Yoon;Kim, Jin-Hee;Choi, Doo-Ho;Yun, Hyong-Geun;Kim, Woo-Cheol;Yang, Dae-Sik;Sohn, Seung-Chang;Suh, Hyun-Suk;Ahn, Ki-Jung;Chun, Mi-Son;Lee, Kyu-Chan;Choi, Young-Min;Jeung, Tae-Sik;Kang, Jin-Oh
    • Radiation Oncology Journal
    • /
    • v.27 no.4
    • /
    • pp.201-209
    • /
    • 2009
  • Purpose: To investigate the care patterns for radiation therapy and to determine inter-hospital differences for patients with laryngeal carcinoma in Korea. Materials and Methods: A total of 237 cases of laryngeal carcinoma (glottis, 144; supraglottis, 93) assembled from 23 hospitals, who underwent irradiation in the year of 1998 and 1999, were retrospectively analyzed to investigate inter-hospital differences with respect to radiotherapy treatment. We grouped the 23 hospitals based on the number of new patients annually irradiated in 1998; and designated them as group A (${\geq}$900 patients), group B (${\geq}$400 patients and <900 patients), and group C (<400 patients). Results: The median age of the 237 patients was 62 years (range, 25 to 88 years), of which 216 were male and 21 were female. The clinical stages were distributed as follows: for glottis cancer, I; 61.8%, II; 21.5%, III; 4.2%, IVa; 11.1%, IVb; 1.4%, and in supraglottic cancer, I; 4.3%, II; 19.4%, III; 28.0%, IVa; 43.0%, IVb; 5.4%, respectively. Some differences were observed among the 3 groups with respect to the dose calculation method, radiation energy, field arrangement, and use of an immobilization device. No significant difference among 3 hospital groups was observed with respect to treatment modality, irradiation volume, and median total dose delivered to the primary site. Conclusion: This study revealed that radiotherapy process and patterns of care are relatively uniform in laryngeal cancer patients in Korean hospitals, and we hope this nationwide data can be used as a basis for the standardization of radiotherapy for the treatment of laryngeal cancer.