• 제목/요약/키워드: endosseous implant

검색결과 78건 처리시간 0.023초

임플란트 식립 부위의 골밀도 평가에 관한 연구 (The study of bone density assessment on dental implant sites)

  • 박수원;장수미;최병환;손한나;박봉찬;김창환;손장호;성일용;이지호;조영철
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권5호
    • /
    • pp.417-422
    • /
    • 2010
  • Introduction: Bone density is one of the important factors for the long term success of endosseous implants. The bone density varies from site to site and from patient to patient. A preoperative evaluation of the bone density is quite useful to oral surgeons for planning dental implantation. More accurate information on the bone density will help surgeons identify suitable implant sites, thereby increase the success rate of dental implantation. This study examined the correlation between the bone density measured preoperatively by computed tomography (CT) and the implant primary stability measured by resonance frequency analysis. Furthermore, the effects of the implant sites, gender, age and generalized systemic disorder patients on the bone density and primary implant stability were examined. Materials and Methods: One hundred and fourteen patients were selected. None of the patients had undergone a tooth extraction or bone graft history in the previous year. Preoperatively, the patients underwent CT scanning to evaluate the Hounsfield unit (HU), and resonance frequency analysis (RFA) was used to evaluate the implant primary stability at the time of implant installation. All implants were 4.0 mm diameter and 11.5 mm length US II. All patients were recorded and the HU and implant stability quotient (ISQ) value were evaluated according to the sites, gender and age. Results: The highest HU values were found in the mandibular anterior site ($827.6{\pm}151.4$), followed by the mandibular molar site ($797{\pm}135.1$), mandibular premolar site ($753.8{\pm}171.2$), maxillary anterior site ($726.3{\pm}154.4$), maxillary premolar site ($656.7{\pm}173.8$) and maxillary molar site ($621.5{\pm}164.9$). The ISQ value was the highest in the mandibular premolar site ($81.5{\pm}2.4$) followed by the mandibular molar site ($80.0{\pm}5.7$), maxillary anterior site ($77.4{\pm}4.1$), mandibular anterior site ($76.4{\pm}11.9$), maxillary premolar site ($74.2{\pm}14.3$) and maxillary molar site ($73.7{\pm}7.4$). The mean HU and ISQ value were similar in females and males. (HU: P=0.331, ISQ: P=0.595) No significant difference was also found in the age group respectively. However, the correlation coefficients between the variables showed a closed correlation between the HU and ISQ value. Conclusion: These results showed close correlation between the bone density (HU) and primary stability value (ISQ) at the time of implant installation (Correlation coefficients=0.497, P<0.01). These results strengthen the hypothesis that it might be possible to predict and quantify the initial implant stability and bone density from a presurgical CT diagnosis.

공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구 (A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS)

  • 박철;임주환;조인호;임헌송
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

임플랜트 시술을 위한 치조돌기와 상악동 주변 구조물의 형태계측적 연구 (MORPHOMETRICS OF ALVEOLAR PROCESS AND ANATOMICAL STRUCTURES AROUND INFERIOR MAXILLARY SINUS FOR MAXILLARY IMPLANTATION)

  • 박주진;이영수;백두진;박원희;유동엽
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.228-239
    • /
    • 2007
  • Statement of problem: Following tooth loss, the edentulous alveolar process of maxilla is affected by irreversible reabsorption process, with progressive sinus pneumatization leads to leaving inadquate bone height for placement of endosseous implants. Grafting the floor of maxillary sinus by sinus lifting surgery and augmentation of autologous bone or alternative bone material is a method of attaining sufficient bone height for maxillary implants placement and has proven to be a highty successful. Purpose: This study was undertaken to clarify the morphometric characteristics of inferior maxillary sinus and alveolar process for installation of implants. Material and method: Nineteen skulls (37 sinuses, 10M / 9F) obtained from the collection of the department of anatomy and cell biology of Hanyang medical school were studied. The mean age of the deceased was 69.9 years (range 44 to 88 years). The distance between alveolar border and inferior sinus margin at each tooth, the height of alveolar process and the thickness of cortical bone of the outer and inner table of alveolar process and the inferior wall of maxillary sinus were measured. Results and Conclusion: 1. The septum of inferior maxillary sinus were observe 28 sides (76.%) and located at the third molar (52.6%) and the second molar (26.3%). The deepest points of inferior border of maxillary sinus were located the first or second molar. The distance between alveolar margin and the deepest point of inferior maxillary sinus is $9.7{\pm}4.9mm$. 2. The length of the outer table of alveolar process were $4.9\sim28.2mm$ and the shortest point was between the first and the second molors. The thickness of them were $0.9\sim3.2mm$. The length of the inner table of alveolar process were $7.4\sim25.8mm$ and the shortest point was between the first and the second molars. The thickness of the were $0.9\sim4.6mm$. The results of this study are useful anatomical data for installing of maxillary implants.

컴퓨터 영상을 이용한 임플란트 식립부위의 골밀도와 조직학적 연구 (BONE DENSITY AND HISTOMORPHOMETRY ASSESSMENT OF DENTAL IMPLANT USING COMPUTERIZED TOMOGRAPHY)

  • 손장호;최병환;박수원;조영철;성일용;이지호;변기정
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권2호
    • /
    • pp.136-142
    • /
    • 2009
  • Bone density in the recipient implant site seems to be an important factor for long term success of endosseous implants. Preoperative evaluation of bone density is very helpful to assist the clinician with the treatment planning of implant therapy. Accurate information on bone density will help the surgeon identify suitable implant sites, thereby improving the success rate of the procedure. Purpose; The aim of this study was to evaluate a correlation between bone density measured preoperatively with computerized tomography and histologically measured bone density by bone biopsy. Patients and methods; Twenty seven patients were selected. All the patients were in good health, with no systemic disorder and additional bone graft. Preoperatively the patients underwent CT scanning to evaluate Houmsfield Unit(HU). Each patients wore a surgical template for implant placement. During surgery 2mm in diameter and 6mm in length specimens were taken. Histomorphometric analysis was performed using digitalized image analysis software Axiovision 4.3. Also, the Resonance frequency analysis(RFA) and insertion torque values were recorded. Results; The highest histomorphometric values was found in the posterior mandible $32.3{\pm}3.8$, followed by $29.9{\pm}2.6$ for the posterior maxilla, $29.4{\pm}2.6$ for the anterior maxilla, $28.6{\pm}2.3$ for the anterior mandible(p=0.214). The hounsfield unit was $989.2{\pm}258.1$ in the posterior mandible, $845.0{\pm}241.5$ in the anterior maxilla, $744.5{\pm}92.6$ in the anterior mandible, $697.3{\pm}136.9$ in the posterior maxilla(p=0.045). This results may suggest that there are strong correlation between the histomorphometric values and hounsfield unit(r=0.760, p<0.05). The RF measurements were $81.9{\pm}2.4$ ISQ in the posterior mandible, $79.0{\pm}1.4$ ISQ in the anterior mandible, $78.3{\pm}4.6$ ISQ in the posterior maxilla, $76.5{\pm}5.0$ ISQ in the anterior maxilla(p=0.048). The insertion torque values was $43.2{\pm}4.2\;Ncm$ in the posterior mandible, $42.0{\pm}0.0\;Ncm$ in the anterior mandible, $41.3{\pm}4.1\;Ncm$ in the posterior maxilla, $40.8{\pm}3.8\;Ncm$ in the anterior maxilla(p=0.612). This results may suggest that there are statistical significance between the hounsfield unit and the insertion torque values(r=0.494, p<0.05), the histomorphometric values and the insertion torque values(r=0.689, p<0.05). But there was no correlation between histomorphometric values and ISQ. There was no statistical significance in age and gender effect on parameters. Conclusions; There was significant correlations between bone density and implant stability parameters. The bone density measurements using preoperative CT may help clinicians to predict primary stability before implant insertion, which is associated with implant survival rates.

기계적 표면 처리된 TITANIUM PLASMA SPRAYED IMPLANT에 대한 치은섬유아세포전개양상의 형태학적 관찰 (THE MORPHOLOGICAL OBSERVATION OF HUMAN GINGIVAL FIBROBLASTS ATTACHMENT AND SPREADING ON THE MECHANICAL TREATED TITANIUM PLASMA SPRAYED IMPLANT SURFACE)

  • 황연희;이재목;서조영
    • Journal of Periodontal and Implant Science
    • /
    • 제25권3호
    • /
    • pp.741-755
    • /
    • 1995
  • 구강내 매식된 임프란트가 과도한 교합력이나 염증등의 이유로 구강내로 노출되었을 때 세균독소에 이완된 면을 제거하고 평활한 면을 형성하여 주위의 연조직, 경조직에 적합한 상태로 만들어 건강한 상태로 구강내에 유지하기 위해서 임프란트 매식체 표면을 기계적인 표면처리방법으로 처치하여 이러한 방법이 임프란트 표면성분, 치은섬유아세포의 전개양상에 미치는 영향을 알아보고자 본 실험을 실행하였다. IMZ사에서 제작한 직경 10mm, 높이 2mm의 원판 타이타늄을 이용하여 피막되지 않은 타이타늄면과 TPS면을 대조군으로 하고 기계적인 표면처리방법인 low speed stone bur처치면을 실험군으로 설정한 후 EDX로 타이타늄 표면성분을 분석하였고 주사전자현미경으로 치은섬유아세포의 전개양상을 관찰하였다. EDX에 의한 타이타늄 표면성분분석 결과 모든 실험군에서 titanium peak, 소량의 aluminum이 나타났으며 그외의 성분은 나타나지 않았다. 치은섬유아세포의 전개양상에 대한 주사전자현미경 관찰결과 평활한 타이타늄면에서 접종 30분 후 세사상돌기와 박판엽상으로 확장된 세포가 많이 관찰되며 6시간 후 신장된 치은섬유아세포가 시편에 밀착된 양상을 보였고 24시간 후 치은섬유아세포는 시편의 모든 면을 피개하며 가공시의 평행한 선을 따라 방향성을 띄었다. TPS가 잔존한 stone처치군에서 세포 접종 30분 후 세사상돌기가 적게 관찰되어 평활한 타이타늄면에 비해 초기부착이 늦은 것을 알 수 있었고 6, 24시간후 치은섬유아세포는 거친면으로 인해 시편에 밀착되지 못한 양상을 보였으나 평활한 타이타늄면과 연결되며 시편의 모든면을 피개하였다. TPS군에서 치은섬유아세포는 세포 접종 30분후 세사상돌기를 거의 찾아 볼 수 없어 초기부착이 다른군에 비해 늦으며 세포배양 6, 24시간후에도 시편에 밀착되지 못하고 박판상돌기가 가늘고 길게 돌출되어 여러면에 부착된 양상을 보였으며 세포가 부착되지 않은 TPS면이 관찰되었다.

  • PDF

원광대학교 산본치과병원에서 770명의 환자에 식립한 2158개의 골유착성 임플란트의 보철 전 초기 생존율에 관한 후향적 연구 (Retrospective study on survival rate of 2158 osseointegrated implants placed in 770 patients in Sanbon dental hospital of Wonkwang University)

  • 선화경;지영덕
    • 구강회복응용과학지
    • /
    • 제30권4호
    • /
    • pp.278-288
    • /
    • 2014
  • 목적: 이 연구의 목적은 상악 및 하악의 완전 무치악 및 부분 무치악 부위에 식립된 골유착성 임플란트의 보철 전 초기 생존율 및 생존과 관련된 요소를 평가하고 실패를 야기하는 요인에 대해 알아보는 것이다. 연구 재료 및 방법: 2004년부터 2013년까지 770명의 환자에서 총 2158개의 골내 임플란트를 식립하였다. 임플란트의 소실과 환자의 연령 및 성별, 식립 위치, 임플란트 시스템, 길이 및 직경, 그리고 골이식 방법과의 연관성을 평가하기 위해 임상적 비교를 시행하였다. 결과: 임플란트 식립 위치에 따라 상악 전치부에서 98.23%, 상악 구치부 96.97%, 하악 전치부 97.85%, 하악 구치부 98.75%의 임플란트 생존율을 보였다(P < 0.05). 임플란트의 종류 및 표면처리 기법은 임플란트 생존율과 특이성을 보이지 않았다. 임플란트 매식체의 직경에 따라 3.0 mm 이하의 임플란트에서 100%, 3.0 - 3.5 mm 97.09%, 3.5 - 4.0 mm 98.19%, 4.0 - 4.5 mm 98.29%의 생존율을 보였고, 5.0 mm 이상의 직경을 가진 넓은 폭경의 임플란트에서 75%의 비교적 낮은 생존율을 보였다(P < 0.05). 임플란트 매식체의 길이에 따라 9 - 11 mm 및 11 - 13 mm의 길이를 가진 임플란트에서 각각 98.12% 및 98.17%의 높은 생존율을 보였으나 통계학적 유의성을 가지진 못하였다. 골이식술의 방법에 따라 상악동 골이식술을 단독으로 시행한 부위에서 임플란트 생존율은 89.05%, 골유도 재생술을 단독으로 시행한 경우 98.28%, 상악동 골이식술과 골유도 재생술을 동시에 시행한 경우 98.34%, 골이식술이 동반되지 않은 경우 99.28%의 생존율을 보였다(P < 0.05). 결론: 이번 연구에서 임플란트 식립 후 최종 보철물 시적 전 초기단계에서의 임플란트 생존율은 임플란트의 식립위치, 임플란트 매식체의 직경, 그리고 골이식 방법과 관련이 있었다. 이러한 결과에 따라 각각 상악 구치부, 5.0 mm 이상의 넓은 임플란트, 그리고 상악동 골이식술을 단독으로 시행한 부위에서 현저하게 낮은 생존율을 확인할 수 있었다.

Maxillary Sinus Grafts for Endosseous Implant Placement: A Literature Review

  • Park, Seung-Byung;Kim, Su-Gwan;Baek, Sung-Moon;Ahn, Yu-Seok;Moon, Kyung-Nam;Jeon, Woo-Jin;Oh, Ji-Su;Lee, Jeong-Hoon;Im, Jae-Hyung;Yoo, Kyung-Hwan;Kim, Jin-Ha
    • Journal of Korean Dental Science
    • /
    • 제3권1호
    • /
    • pp.25-31
    • /
    • 2010
  • This study sought to evaluate the effect of the type of grafts used in sinus lifting. A review of literature through MEDLINE search covering the period 1980 ~ 2006 was performed. After screening, this study was narrowed down to 2,452 patients receiving sinus lift grafts wherein 7,151 implants were placed. In this study, the types of grafts used in sinus augmentation were autogenous bone, allogenic bone, corticocancellous block bone, and various alloplastic materials. The success rate varied from 69% to 100% depending on the graft material type. The highest success rate was reported for the autogenous bone, with high success rates recorded for the most part in most studies.

  • PDF

이온빔 보조 전자빔 수산화 인회석 증착이 골내 임플란트의 골유착에 미치는 영향 (EFFECTS OF THE ION BEAM ASSISTED DEPOSITION OF HYDROXYAPATITE ON OSSEOINTEGRATION OF THE ENDOSSEOUS IMPLANTS IN RABBIT TIBIAE)

  • 정영철;한종현;이인섭;이현정;김명호
    • 대한치과보철학회지
    • /
    • 제38권5호
    • /
    • pp.659-674
    • /
    • 2000
  • A large increase in the use of thin film coating of hydroxyapatite(HA) in implant dentistry is driven by the desire to take advantage of the excellent biocompatibility and high strength of HA coating. The purpose of this study was to evaluate the effects of HA-coated implants by ion Beam Assisted Deposition(IBAD) method in comparison to the sand-blasted and machined surfaces. Osteoblast culture test, removal torque test and histomorphometric analysis were performed and the following results obtained; 1. Examination of the osteoblast cultures displayed no difference in the secretion of alkaline phosphatase between the various specimen, but IBAD with pure HA specimen showed low alkaline phosphatase secretion(p<0.05). 2. Removal torque tests showed HA-coated implants by IBAD method to be similar in high value to the implants with sand-blasted surface than the implants with machined surface. And the ovariectomized group showed low mechanical test value than the normal group(p<0.05). 3. Histomorphometrical comparisons were performed on undecalcified ground sections. HA-coated implants by IBAD method demonstrated the highest mean bone-to-metal contact ratio on all threads and 3-best consecutive threads, and the implants with sand-blasted surface and implants with machined surface was in the next consecutive order(p<0.05). HA-coated implants showed slightly higher bone-to- metal contact ratio than sand-blasted implants, but no statistically significant difference was obtained between the two materials. The ovariectomized group showed lower value of bone-to-metal contact ratio than the normal group, but no statistically significant difference was obtained between the two groups. 4. Evaluation of bone volume on all threads and 3-best consecutive threads showed no statistically significant difference among the different surface treatment groups, but showed lower bone volume in ovariectomized group than in the normal group(p<0.05). According tn these results, thin film coated implants with HA showed high bone contact ratio, bone volume and removal torque strength in the short term, but long term observation is needed.

  • PDF