• 제목/요약/키워드: endoscopic robot

검색결과 17건 처리시간 0.026초

내시경 로봇의 기술동향 (Technological Trend of Endoscopic Robots)

  • 김민영;조형석
    • 제어로봇시스템학회논문지
    • /
    • 제20권3호
    • /
    • pp.345-355
    • /
    • 2014
  • Since the beginning of the 21st century, emergence of innovative technologies in robotic and telepresence surgery has revolutionized minimally access surgery and continually has advanced them till recent years. One of such surgeries is endoscopic surgery, in which endoscope and endoscopic instruments are inserted into the body through small incision or natural openings, surgical operations being carried out by a laparoscopic procedure. Due to a vast amount of developments in this technology, this review article describes only a technological state-of-the arts and trend of endoscopic robots, being further limited to the aspects of key components, their functional requirements and operational procedure in surgery. In particular, it first describes technological limitations in developments of key components and then focuses on the description of the performance required for their functions, which include position control, tracking, navigation, and manipulation of the flexible endoscope body and its end effector as well, and so on. In spite of these rapid developments in functional components, endoscopic surgical robots should be much smaller, less expensive, easier to operate, and should seamlessly integrate emerging technologies for their intelligent vision and dexterous hands not only from the points of the view of surgical, ergonomic but also from safety. We believe that in these respects a medical robotic technology related to endoscopic surgery continues to be revolutionized in the near future, sufficient enough to replace almost all kinds of current endoscopic surgery. This issue remains to be addressed elsewhere in some other review articles.

C-arm 영상 기반 척추 디스크 내시경 수술을 위한 가이드 바늘 삽입 보조 시스템 (Method for C-arm Based Guide Needle Insertion Assistant System for Endoscopic Disc Surgery)

  • 윤현민;조현철;박규식;신상균;이득희
    • 한국CDE학회논문집
    • /
    • 제20권3호
    • /
    • pp.263-268
    • /
    • 2015
  • Due to an increased sitting time in work, lumbar disc disease is one of the most frequent diseases in modern days, and this occasionally requires surgery for treatment. Endoscopic disc surgery, one of the common disc surgeries, requires a process of inserting a guide needle to the target disc for which the insertion path is manually planned by drawing lines on the patient's skin while monitoring the fluoroscopic view of the lumbar. Such procedure inevitably exposes both surgeon and patient to the fluoroscopy radiation emitted from the c-arm for a long time. To reduce the radiation exposure time, this study proposes a computer assisted method of calculating the 3D guide needle path by using 2D c-arm images of the disc in 3 different angles. Additionally, a method of the guide robot control based on the 3D needle path was developed by implementing the Hand-eye Calibration method to calculate the transformation matrix between the c-arm and robot base coordinate systems. The proposed system was then tested for its accuracy.

두경부 영역에서의 로봇 수술 (Robotic Surgery in Head and Neck)

  • 태경;신광수
    • 대한기관식도과학회지
    • /
    • 제16권1호
    • /
    • pp.27-32
    • /
    • 2010
  • Organ preservation surgery and minimally invasive surgery have been developed during the past 20 years with major focus on transoral laser surgery, endoscopic surgery, and robotic surgery. Two major robotic surgeries in head and neck area are transoral robotic surgery (TORS) and robotic thyroidectomy. Transoral robotic surgery is a safe and efficacious method of surgical treatment of oropharyngeal. hypopharyngeal and laryngeal neoplasm. Advantages of the technique include adequate ability to visualize and manipulate lesions with two hands. TORS can provide magnified three dimensional views and overcome the limitation resulting from the "line of sight" which hinders transoral laser procedure. The swallowing function following transoral robotic surgery show superior and patients were able to retain or rapidly regain swallowing function in the majority of cases. Recently, robotic thyroidectomy has also been developed to overcome the [imitation of endoscopic thyroidectomy. Robotic thyroidectomy by a gasless unilateral axillo-breast or axillary approach using a da Vinci S Surgical Robot is a feasible and cosmetically excellent procedure. It can be a promising alternative to endoscopic thyroidectomy or conventional open thyroidectomy.

  • PDF

체내이동형 마이크로 캡술형 내시경 로봇을 위한 Electrostrictive Polymer의 모델링 및 Adaptive fuzzy 알고리듬 개발 (The Modeling and Adaptive fuzzy control of Electrostrictive Polymer for endoscopic microcapsule)

  • 황교일;김훈모;최혁렬;남재도;전재욱
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.716-722
    • /
    • 2001
  • In this paper, the modeling and control of electrostrictive polymer is introduced for endoscopic microcapsule. The endoscopic microcapsule works in the body, so the material of robot must be no harmful to the body. The electrostrictive polymer satisfies this condition. The modeling and control of endoscope microcapsule must be processed. So the modeling and control of electrostrictive was processed preferentially. The electrostrictive polymer is so flexible that we considered the electrostrictive polymer as flexible membrane. The dynamic equation of flexible membrane is time variant in electrostrictive polymer. It is the reason that the elastic modulus of electrostrictive polymer is very small and changes as deformation of electrostrictive polymer. The control algorithm must overcome these characteristics. So the algorithm of adaptive fuzzy control was used to control. In this paper, we introduced the dynamic modeling and control of electrostrictive polymer. And its deformation is introduced.

  • PDF

Esthetic neck dissection using an endoscope via retroauricular incision: a report of two cases

  • Kim, Jae-Young;Cho, Hoon;Cha, In-Ho;Nam, Woong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제40권1호
    • /
    • pp.27-31
    • /
    • 2014
  • Various surgical techniques, such as endoscopic surgery and robotic surgery, are developed to optimize the esthetic outcome even in operations for malignancy. A modified face-lift or retroauricular approach are used to minimize postoperative scarring. Recently, robot-assisted surgery is being done in various fields and considered as favorable treatment method by many surgeons. However its high cost is a nonnegligible fraction for many patients. On the other hand, endoscopic surgery, which is cheaper than robotic surgery, is minimally invasive with contentable neck dissection. Although it is a difficult technique for a beginner surgeon due to its limited operation view, we suppose it as an alternative method for robotic surgery. Herein, we report two cases of endoscopic neck dissection via retroauricular incision with a discussion regarding the pros and cons of endoscopic neck dissection.

Research on the cable-driven endoscopic manipulator for fusion reactors

  • Guodong Qin;Yong Cheng;Aihong Ji;Hongtao Pan;Yang Yang;Zhixin Yao;Yuntao Song
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.498-505
    • /
    • 2024
  • In this paper, a cable-driven endoscopic manipulator (CEM) is designed for the Chinese latest compact fusion reactor. The whole CEM arm is more than 3000 mm long and includes end vision tools, an endoscopic manipulator/control system, a feeding system, a drag chain system, support systems, a neutron shield door, etc. It can cover a range of ±45° of the vacuum chamber by working in a wrap-around mode, etc., to meet the need for observation at any position and angle. By placing all drive motors in the end drive box via a cable drive, cooling, and radiation protection of the entire robot can be facilitated. To address the CEM motion control problem, a discrete trajectory tracking method is proposed. By restricting each joint of the CEM to the target curve through segmental fitting, the trajectory tracking control is completed. To avoid the joint rotation angle overrun, a joint limit rotation angle optimization method is proposed based on the equivalent rod length principle. Finally, the CEM simulation system is established. The rationality of the structure design and the effectiveness of the motion control algorithm are verified by the simulation.

Surgical Outcomes of Congenital Atrial Septal Defect Using da VinciTM Surgical Robot System

  • Kim, Ji Eon;Jung, Sung-Ho;Kim, Gwan Sic;Kim, Joon Bum;Choo, Suk Jung;Chung, Cheol Hyun;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • 제46권2호
    • /
    • pp.93-97
    • /
    • 2013
  • Background: Minimally invasive cardiac surgery has emerged as an alternative to conventional open surgery. This report reviews our experience with atrial septal defect using the da VinciTM surgical robot system. Materials and Methods: This retrospective study included 50 consecutive patients who underwent atrial septal defect repair using the da VinciTM surgical robot system between October 2007 and May 2011. Among these, 13 patients (26%) were approached through a totally endoscopic approach and the others by mini-thoracotomy. Nineteen patients had concomitant procedures including tricuspid annuloplasty (n=10), mitral valvuloplasty (n=9), and maze procedure (n=4). The mean follow-up duration was $16.9{\pm}10.4$ months. Results: No remnant interatrial shunt was detected by intraoperative or postoperative echocardiography. The atrial septal defects were mainly repaired by Gore-Tex patch closure (80%). There was no operative mortality or serious surgical complications. The aortic cross clamping time and cardiopulmonary bypass time were $74.1{\pm}32.2$ and $157.6{\pm}49.7$ minutes, respectively. The postoperative hospital stay was $5.5{\pm}3.3$ days. Conclusion: The atrial septal defect repair with concomitant procedures like mitral valve repair or tricuspid valve repair using the da VinciTM system is a feasible method. In addition, in selected patients, complete port access can be helpful for better cosmetic results and less musculoskeletal injury.

식도암 환자에서 da Vinci 로봇을 이용한 식도암 수술 (흉골하 통로를 통한 식도-위 문합술) - 1예 보고 - (da Vinci Robot-Assisted Esophagectomy for Esophageal Cancer: A Case of Esophago-gastrostomy through the Retrosternal Route - A case report -)

  • 정상석;최필조;우종수;김시호;방정희;박권재
    • Journal of Chest Surgery
    • /
    • 제42권3호
    • /
    • pp.396-400
    • /
    • 2009
  • 다빈치 로봇수술은 현재 다양한 외과영역에서 시행되고 있으나 폐, 식도 외과영역에서는 아직까지 널리 이용되지 않고 있다. 본원에서는 74세 남자환자가 딸꾹질과 연하곤란을 주소로 내원하여 시행한 검사에서 식도암으로 진단되어 da Vinci 로봇을 이용하여 식도절제술을 시행한 후, 복강경으로 위장튜브를 만들어 흉골하 통로를 통해 경부에서 위장-식도 단단 문합을 시행하였다. 환자는 수술 후 특별한 합병증 없이 완쾌 퇴원하였다. 향후 다빈치로봇을 이용한 최소 침습수술이 식도암을 비롯한 폐, 식도외과 영역에의 활용에 있어서 좋은 결과가 기대되므로 보고하는 바이다.

조기 폐암에서 다빈치 로봇을 이용한 폐엽절제술 - 3예 보고 - (Da Vinci Robot-Assisted Pulmonary Lobectomy in Early Stage Lung Cancer - 3 cases report -)

  • 함석진;이교준;조상호;김형중;전세은;이두연
    • Journal of Chest Surgery
    • /
    • 제41권5호
    • /
    • pp.659-662
    • /
    • 2008
  • 흉강경을 이용한 폐절제술이 1990년대 초반 처음으로 소개된 이후로 조기 폐암 환자의 수술에 있어 안정성과 적합성이 발표되면서 그 시행 횟수가 서서히 증가되고 있다. 그러나, 흉강경을 이용한 수술은 2차원 영상과 불안정한 카메라의 움직임, 기구의 움직임이 제한되는 등의 여러 가지 단점들이 있다. 이러한 단점을 극복하고 최근에 개발된 다빈치 로봇 시스템은 고해상도의 3차원 입체영상과 사람의 팔목관절과 유사한 움직임을 구사하는 기구들로 인하여 더욱 안정되고 편리하게 수술을 시행할 수 있게 하였다. 본원에서는 다빈치 로봇 시스템을 이용하여 3명의 조기 폐암환자에서 폐엽 절제술을 시행하였기에 보고하는 바이다.

Intracorporeal Esophagojejunostomy during Reduced-port Totally Robotic Gastrectomy for Proximal Gastric Cancer: a Novel Application of the Single-Site® Plus 2-port System

  • Choi, Seohee;Son, Taeil;Song, Jeong Ho;Lee, Sejin;Cho, Minah;Kim, Yoo Min;Kim, Hyoung-Il;Hyung, Woo Jin
    • Journal of Gastric Cancer
    • /
    • 제21권2호
    • /
    • pp.132-141
    • /
    • 2021
  • Purpose: Intracorporeal esophagojejunostomy during reduced-port gastrectomy for proximal gastric cancer is a technically challenging technique. No study has yet reported a robotic technique for anastomosis. Therefore, to address this gap, we describe our reduced-port technique and the short-term outcomes of intracorporeal esophagojejunostomy. Materials and Methods: We conducted a retrospective review of patients who underwent a totally robotic reduced-port total or proximal gastrectomy between August 2016 and March 2020. We used an infra-umbilical Single-Site® port with two additional ports on both sides of the abdomen. To transect the esophagus, a 45-mm endolinear stapler was inserted via the right abdominal port. The common channel of the esophagojejunostomy was created between the apertures in the esophagus and proximal jejunum using a 45-mm linear stapler. The entry hole was closed with a 45-mm linear stapler or robot-sewn continuous suture. All anastomoses were performed without the aid of an assistant or placement of stay sutures. Results: Among the 40 patients, there were no conversions to open, laparoscopic, or conventional 5-port robotic surgery. The median operation time and blood loss were 254 min and 50 mL, respectively. The median number of retrieved lymph nodes was 40.5. The median time to first flatus, soft diet intake, and length of hospital stay were 3, 5, and 7 days, respectively. Three (7.5%) major complications, including two anastomosis-related complications and a case of small bowel obstruction, were treated with an endoscopic procedure and re-operation, respectively. No mortality occurred during the study period. Conclusions: Intracorporeal esophagojejunostomy during reduced-port gastrectomy can be safely performed and is feasible with acceptable surgical outcomes.