DOI QR코드

DOI QR Code

Surgical Outcomes of Congenital Atrial Septal Defect Using da VinciTM Surgical Robot System

  • Kim, Ji Eon (Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, University of Ulsan College of Medicine) ;
  • Jung, Sung-Ho (Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, University of Ulsan College of Medicine) ;
  • Kim, Gwan Sic (Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, University of Ulsan College of Medicine) ;
  • Kim, Joon Bum (Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, University of Ulsan College of Medicine) ;
  • Choo, Suk Jung (Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, University of Ulsan College of Medicine) ;
  • Chung, Cheol Hyun (Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, University of Ulsan College of Medicine) ;
  • Lee, Jae Won (Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, University of Ulsan College of Medicine)
  • Received : 2012.08.27
  • Accepted : 2012.10.09
  • Published : 2013.04.05

Abstract

Background: Minimally invasive cardiac surgery has emerged as an alternative to conventional open surgery. This report reviews our experience with atrial septal defect using the da VinciTM surgical robot system. Materials and Methods: This retrospective study included 50 consecutive patients who underwent atrial septal defect repair using the da VinciTM surgical robot system between October 2007 and May 2011. Among these, 13 patients (26%) were approached through a totally endoscopic approach and the others by mini-thoracotomy. Nineteen patients had concomitant procedures including tricuspid annuloplasty (n=10), mitral valvuloplasty (n=9), and maze procedure (n=4). The mean follow-up duration was $16.9{\pm}10.4$ months. Results: No remnant interatrial shunt was detected by intraoperative or postoperative echocardiography. The atrial septal defects were mainly repaired by Gore-Tex patch closure (80%). There was no operative mortality or serious surgical complications. The aortic cross clamping time and cardiopulmonary bypass time were $74.1{\pm}32.2$ and $157.6{\pm}49.7$ minutes, respectively. The postoperative hospital stay was $5.5{\pm}3.3$ days. Conclusion: The atrial septal defect repair with concomitant procedures like mitral valve repair or tricuspid valve repair using the da VinciTM system is a feasible method. In addition, in selected patients, complete port access can be helpful for better cosmetic results and less musculoskeletal injury.

Keywords

References

  1. Brickner ME, Hillis LD, Lange RA. Congenital heart disease in adults: first of two parts. N Engl J Med 2000;342: 256-63. https://doi.org/10.1056/NEJM200001273420407
  2. Je HG, Lee YJ, Jung SH, et al. The first 20 cases of cardiac surgery using the da Vinci (TM) surgical system: a single center experience. Korean J Thorac Cardiovasc Surg 2008;41:423-9.
  3. Kim GS, Lee JW, Jung SH, Kim JB, Jung JP. Completely port-accessed atrial septal defect patch closure using the da Vinci System: a case report. Korean J Thorac Cardiovasc Surg 2010;43:409-12. https://doi.org/10.5090/kjtcs.2010.43.4.409
  4. Morgan JA, Peacock JC, Kohmoto T, et al. Robotic techniques improve quality of life in patients undergoing atrial septal defect repair. Ann Thorac Surg 2004;77:1328-33. https://doi.org/10.1016/j.athoracsur.2003.09.044
  5. Suri RM, Antiel RM, Burkhart HM, et al. Quality of life after early mitral valve repair using conventional and robotic approaches. Ann Thorac Surg 2012;93:761-9. https://doi.org/10.1016/j.athoracsur.2011.11.062
  6. Bonaros N, Schachner T, Wiedemann D, et al. Quality of life improvement after robotically assisted coronary artery bypass grafting. Cardiology 2009;114:59-66. https://doi.org/10.1159/000212115
  7. Torracca L, Ismeno G, Alfieri O. Totally endoscopic computer- enhanced atrial septal defect closure in six patients. Ann Thorac Surg 2001;72:1354-7. https://doi.org/10.1016/S0003-4975(01)02990-3
  8. Argenziano M, Oz MC, Kohmoto T, et al. Totally endoscopic atrial septal defect repair with robotic assistance. Circulation 2003;108 Suppl 1:II191-4.
  9. Stevens JH, Burdon TA, Peters WS, et al. Port-access coronary artery bypass grafting: a proposed surgical method. J Thorac Cardiovasc Surg 1996;111:567-73. https://doi.org/10.1016/S0022-5223(96)70308-2
  10. Bonaros N, Schachner T, Oehlinger A, et al. Robotically assisted totally endoscopic atrial septal defect repair: insights from operative times, learning curves, and clinical outcome. Ann Thorac Surg 2006;82:687-93. https://doi.org/10.1016/j.athoracsur.2006.03.024
  11. Bonatti J, Schachner T, Bernecker O, et al. Robotic totally endoscopic coronary artery bypass: program development and learning curve issues. J Thorac Cardiovasc Surg 2004; 127:504-10. https://doi.org/10.1016/j.jtcvs.2003.09.005

Cited by

  1. Totally endoscopic congenital heart surgery compared with the traditional heart operation in children vol.125, pp.21, 2013, https://doi.org/10.1007/s00508-013-0438-8
  2. Minimally invasive paediatric cardiac surgery vol.11, pp.1, 2014, https://doi.org/10.1038/nrcardio.2013.168
  3. Current Trend of Robotic Thoracic and Cardiovascular Surgeries in Korea: Analysis of Seven-Year National Data vol.48, pp.5, 2013, https://doi.org/10.5090/kjtcs.2015.48.5.311
  4. Minimally Invasive Cardiac Surgery versus Conventional Median Sternotomy for Atrial Septal Defect Closure vol.49, pp.6, 2013, https://doi.org/10.5090/kjtcs.2016.49.6.421
  5. The Mid-term Results of Thoracoscopic Closure of Atrial Septal Defects vol.47, pp.5, 2017, https://doi.org/10.4070/kcj.2017.0059
  6. Early Results of Robotically Assisted Congenital Cardiac Surgery: Analysis of 242 Patients vol.112, pp.6, 2013, https://doi.org/10.1016/j.athoracsur.2020.10.028