• Title/Summary/Keyword: end use

Search Result 3,180, Processing Time 0.029 seconds

Annual Intensities (2016-2017) Analysis of Energy Use and CO2 Emission by End Use based on Measurements of Sample Apartment Units (표본건물 계측에 의한 공동주택 세대에서의 용도별 에너지사용량 및 CO2 배출량 연간 원단위 (2016 - 2017) 분석)

  • Jin, Hye-Sun;Lim, Han-Young;Lee, Soo-Jin;Kim, Sung-Im;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.7
    • /
    • pp.43-52
    • /
    • 2018
  • In this study, annual site and primary energy use intensities (EUIs) and CO2 emission intensities (CEIs) per area by end use were estimated based on the measurement data from June 2016 to May 2017 of 50 sample apartment units in Seoul. In addition, estimated site EUIs by end use were compared to the U.S. Residential Energy Consumption Survey (RECS) 2009 data. Site EUIs by end use were found to be in the order of heating > electric appliance > domestic hot water > cooking > lighting > cooling > air movement. In the case of primary EUIs and CEIs by end use, electric appliance was found to be the largest. As results of comparison with the RECS 2009 data, it was found that site EUIs were very similar for heating, domestic hot water and electric appliance, etc., but slightly different for cooling. The number of sample apartment units will continue to increase until 2020 (total number of samples 200) and intensities data by end use will be continuously updated through continuous collection of measurement data.

Annual Intensities (2016-2017) Analysis of Energy Use and CO2 Emission by End Use Based on Measurements of Sample Office Building (표본건물 계측에 의한 업무시설에서의 용도별 에너지사용량 및 CO2 배출량 연간 원단위 (2016 - 2017) 분석)

  • Lim, Han-Young;Lim, Su-Hyun;Jin, Hye-Sun;Kim, Sung-Im;Lee, Soo-Jin;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.8
    • /
    • pp.19-27
    • /
    • 2018
  • In this study, annual site and primary energy use intensities (EUIs) and $CO_2$ emission intensities (CEIs) per area by end use were estimated based on the measurement data from June 2016 to May 2017 of 19 sample office buildings in Seoul. In addition, the estimated site EUIs by end use were compared to the U.S. Commercial Buildings Energy Consumption Survey (CBECS) 2012 data. Average site EUIs by end use were found to be in the order of electric appliance (typical floors) > heating > cooling > lighting > air movement > domestic hot water > vertical transportation > city water supply. In the case of primary EUIs and CEIs by end use, electric appliance was found to be the largest. As results of comparison with the CBECS 2012 data, it was found that the site EUIs were similar for heating, cooling, domestic hot water, and electric appliance, etc., but slightly different for lighting and air movement. The number of sample office buildings will continue to increase until 2020 (total number of samples 85) and intensities data by end use will be continuously updated through continuous collection of measurement data.

Baseline Demand Forecast Model by End-Use in Commercial Buildings (건물용도별 End-Use 기준수요 예측기법)

  • Rhee Chang Ho;Park Jong Jin
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.680-682
    • /
    • 2004
  • 수요관리 프로그램의 개발과 시행을 위해 서는 End-Use별로 수요예측과 잠재량 평가가 필수적이다. 업무용 전력수요는 건물용도에 따라 수요패턴이 상이하다. 여기서는 건물용도별 기준수요 예측을 위한 알고리즘과 절차를 제시하였으며, 이를 토대로 시산분석을 하였다. 용도별 전력수요는 사무실, 호텔, 병원, 도소매, 학교, 창고, 식당, 식료품, 체육시설 둥 건물용도로 구분하였으며, End-Use는 이중 6개 용도에 대해 조명, 동력, 공조, 사무, 기타 등 5개로 나누어 추정하였다.

  • PDF

Estimation Method of Energy Consumption by End-Use in Office Buildings based on the Measurement Data (계측데이터를 이용한 업무시설에서의 에너지용도별 사용량 추정방법 연구)

  • Kim, Sung-Im;Yang, In-Ho;Ha, Soo-Yeon;Lee, Soo-Jin;Jin, Hye-Sun;Suh, In-Ae;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.5
    • /
    • pp.165-176
    • /
    • 2020
  • The purpose of this study is to develop a estimation method of energy consumption by end-use in office buildings. For this, the current status of information on building energy use was investigated, and the domestic and foreign literature on the classification of energy use in non-residential buildings and the estimation method of energy use were reviewed. In addition, the characteristics of energy consumption by end-use were analyzed with measurement data of 48 office buildings in Seoul. As results, the annual and monthly estimation method of energy consumption by end-use in office buildings using public and measurement data was presented, and the applicability of the estimation method was examined by applying to sample office buildings.

Development of DSM(Demand Side Management) Monitoring Methodology Considering the Diffusion Process of High Efficient End-Use Appliances (고효율기기의 보급확산을 고려한 전력수요관리 모니터링시스템의 방법론 개발)

  • Hwang, Sung-Wook;Kim, Bal-Ho;Kim, Jung-Hoon;Chang, Seung-Chan;Kim, Chang-Seob
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.8
    • /
    • pp.941-950
    • /
    • 1999
  • This paper presents a DSM monitoring methodology that is able to evaluate the impact of DSM programs especially focused on the strategic conservation i.e. the enhancement of end-use energy efficiency. For an effective assessment of DSM programs, it is foremost necessary to examine the market characteristics on the specific end-use appliance according to the customer's adoption of DSM programs. The proposed monitoring methodology contains a diffusion process of high efficient end-uses considering major factors of DSM impact such as, price, reference capacity, forecasted capacity and lifetime of end-use appliances. Case studies show the projection of power reductions and energy savings resulted from DSM monitoring in order to diagnose the current status properly and provide a baseline of DSM policy and analysis.

  • PDF

Survey and Analysis of Electric Power Use pattern in Industry (산업용 전력사용실태 조사분석)

  • Park, Jong-Jin;Rhee, Chang-Ho;Kim, Chang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.383-385
    • /
    • 2001
  • This paper presents electric power use pattern by end-use for each industry in Korea. Until now, the survey for industrial electric power use pattern by end-use has been sporadic and unsystematic. This paper presents the systematic survey and analysis for electric power use pattern by end-use. The major survey items include rate power and the number of equipments, and operation rate, etc. This paper will make good use of data base construction and policy for DSM.

  • PDF

A Study on the Factors Affecting the Success of End-User Computing (최종사용자 컴퓨팅의 성패 영향요인 연구)

  • Seo, Geon-Su
    • Asia pacific journal of information systems
    • /
    • v.5 no.2
    • /
    • pp.259-288
    • /
    • 1995
  • Using end-user attitude as intervening variable, this paper proposes a causal model of how environmental factors of EUC influence end-user computing (EUC) success, measured by the degree of IS use. This study identifies unique aspects of the EUC environment and generates key dimensions of end-user attitude appropriate for this context : perceived information quality, perceived design quality, and perceived usefulness. The research model includes six environmental factors - top management support, end-user education, task variability, task analyzability, end-user's computing ability, and end-user involvement. A field study was undertaken to test the hypothesized relationships among the research variables. The results generally support the assumption that end-user attitude intervene the impact of environmental factors on IS use. The implications of the findings are discussed.

  • PDF

The Estimation of Summer Cooling Load Using End-Use Model (End-Use 모델을 이용한 하계 냉방부하 추정)

  • Hur, Don;Kim, Jin-Ho;Hahn, Tae-Kyung;Park, Jong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.166-168
    • /
    • 1999
  • 본 논문은 End-Use 모델의 개념을 정립하고 정화한 데이터를 얻기 위한 설문 조사를 통하여 1999년의 실제 하계 냉방부하를 End-Use 모델을 이용하여 예측하였다. 본 연구를 통하여 에어컨 부하 및 소비행태의 조사에 의한 냉방부하의 특성을 분석하고 합리적인 수요관리를 위한 냉방기기 및 부하 데이터를 축적하고자 한다.

  • PDF

Design of Robot Rotation Arm with Parallel Motion in End Effector (말단 장치의 평면 유지가 가능한 로봇 회전 암의 설계)

  • Lee, Jong-Shin
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.4
    • /
    • pp.359-366
    • /
    • 2010
  • This study proposes the design method for the robot rotation arm which the end effector that is connected in end of the arm keeps parallel motion even though the robot arm rotates. So far, most robot arm rotates together the end effector when the arm rotates. For this, this study proposes the mechanism that the arm is linked to each 4 parallel link so that rotation is possible by 4 pins, and the rotation arm connects 2 joints of diagonal line direction to a link in each 4 joint for rotation, and designs so that can change length of the link. For verification of design, this study targeted that develop the rotation arm for medical examination that use in ophthalmology. It is important that a medical robot offers comport to patient and design compactly so that medical examination and treatment space may can be defined enough. It is designed so that all drive elements may be positioned on interior of the arm and optimization of design for main parts was carried out in this study for this. The robot arm which is developed in this study manufactured to use by medical phoropter arm, and got good result by an experiment. The robot rotation arm which is proposed in this study is judged to contribute very effectively in case use of a medical robot arm for medical examination and treatment, also the robot arm which the end effector that is connected in the end of the arm needs to keep parallel motion. And, the robot arm which is developed in this study made an application as license.

Delay-Constrained Energy-Efficient Cluster-based Multi-Hop Routing in Wireless Sensor Networks

  • Huynh, Trong-Thua;Dinh-Duc, Anh-Vu;Tran, Cong-Hung
    • Journal of Communications and Networks
    • /
    • v.18 no.4
    • /
    • pp.580-588
    • /
    • 2016
  • Energy efficiency is the main objective in the design of a wireless sensor network (WSN). In many applications, sensing data must be transmitted from sources to a sink in a timely manner. This paper describes an investigation of the trade-off between two objectives in WSN design: minimizing energy consumption and minimizing end-to-end delay. We first propose a new distributed clustering approach to determining the best clusterhead for each cluster by considering both energy consumption and end-to-end delay requirements. Next, we propose a new energy-cost function and a new end-to-end delay function for use in an inter-cluster routing algorithm. We present a multi-hop routing algorithm for use in disseminating sensing data from clusterheads to a sink at the minimum energy cost subject to an end-to-end delay constraint. The results of a simulation are consistent with our theoretical analysis results and show that our proposed performs much better than similar protocols in terms of energy consumption and end-to-end delay.