Browse > Article

Design of Robot Rotation Arm with Parallel Motion in End Effector  

Lee, Jong-Shin (주성대학 컴퓨터응용기계과)
Publication Information
The Journal of Korea Robotics Society / v.5, no.4, 2010 , pp. 359-366 More about this Journal
Abstract
This study proposes the design method for the robot rotation arm which the end effector that is connected in end of the arm keeps parallel motion even though the robot arm rotates. So far, most robot arm rotates together the end effector when the arm rotates. For this, this study proposes the mechanism that the arm is linked to each 4 parallel link so that rotation is possible by 4 pins, and the rotation arm connects 2 joints of diagonal line direction to a link in each 4 joint for rotation, and designs so that can change length of the link. For verification of design, this study targeted that develop the rotation arm for medical examination that use in ophthalmology. It is important that a medical robot offers comport to patient and design compactly so that medical examination and treatment space may can be defined enough. It is designed so that all drive elements may be positioned on interior of the arm and optimization of design for main parts was carried out in this study for this. The robot arm which is developed in this study manufactured to use by medical phoropter arm, and got good result by an experiment. The robot rotation arm which is proposed in this study is judged to contribute very effectively in case use of a medical robot arm for medical examination and treatment, also the robot arm which the end effector that is connected in the end of the arm needs to keep parallel motion. And, the robot arm which is developed in this study made an application as license.
Keywords
Robot Rotation Arm; Parallel Motion; End Effector; Parallel Link;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Richard D. Klafter, "Robot Engineering, An Integrated Approach," Prentice‐Hall, Inc., pp.1‐82, 1989.
2 牧野 洋, "로봇 기구학," 일본 일간공업신문사, pp185-186, 1988.
3 이종신, "스카라 로봇 암의 최적화 설계 및 시뮬레이션," 제어.자동화.시스템공학 논문지, 제 15권, 제 6호, pp.612‐618, 2009. 6.   과학기술학회마을
4 http://www.topcon.co.kr/GA/Product/OS-1000SK/OS-1000SK.html.
5 이종신, "의료용 포롭터 암," 특허청, 특허등록번호 10-0982220, 2010.
6 James Rehg, "Introduction to Robotics, A Systems Approach," Prentice-Hall, Inc., pp.25-38, 1985.
7 http://www.huvitz.com/products/products011.php
8 이종신, "스카라 로봇의 성능 평가에 의한 제 2암의 최적 설계," 한국기계기술학회 논문지, 제11권, 제 2호, pp.1‐8, 2009. 6.
9 http://www.yujinmedical.co.kr/3/yujin/OS-2010.html