• 제목/요약/키워드: end diaphragm

검색결과 55건 처리시간 0.032초

MFC 작동기가 부착된 실린더 쉘 구조물의 동적 모델링과 능동 진동제어기 설계 (Dynamic Modeling and of Cylindrical Shell and Design of Active Vibration Controller equipped with MFC actuators)

  • 배병찬;송명호;정문산;곽문규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.75-80
    • /
    • 2007
  • This paper is concerned with the dynamic modeling and controller design for a cylindrical shell equipped with MFC actuators. The dynamic model was derived by using Rayleigh-Ritz method based on Donnel-Mushtari shell theory. The actuator and sensors for the MFC actuator equations were derived based on pinforce model. The boundary conditions at both ends were assumed to be shear diaphragm. After calculating the natural vibration characteristics, the positive position feedback controller was designed to cope with the first two modes. To this end, the equations of motion were reduced to modal equations of motion by considering the modes of interest. The theoretical results show that vibrations can be successfully suppressed.

  • PDF

압전 작동기 거동해석을 위한 유한요소 모사 (Finite Element Analysis of A Piezoelectric Actuator)

  • 이흥식;조종두
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1401-1406
    • /
    • 2003
  • Mechanical behavior of a piezoelectric actuator is studied as a preceding research for the manufacturing of three-dimensional micro-structures. It is needed to examine the simulation of a piezoelectric actuator according to applied direction of voltage, by researching displacement characterization of piezoelectric material through piezoelectric theory. To this end, finite element modeling is employed to study the response of a piezoelectric material under the various input voltages. Where the actuator is simulated by use of ANSYS. To avoid direct contact piezoelectric material with working fluid, silicon, polymer, etc., the actuator is modeled with nickel fixed diaphragm.

  • PDF

철도용 사장교의 주탑 케이블 정착부에 관한 연구 (A Study on Pylon Cable Anchor System in Cable-Stayed Railway Bridge)

  • 한성관;공병승
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.565-580
    • /
    • 2006
  • Set in constant increase and period current of lively technical development of railroad use and construction of cable stayed bridge railway bridge, one of bridge form of most suitable that think side police officer and the material enemy of bridge that use long rail, is increasing laying stress on the foreign countries. Main tower fixing department of this cable stayed bridge is consisted of main tower flange that support bearing plate, bay ring plate bearing plate, support end rib and diaphragm etc, as stress transmission mechanic that tensility of cable socket into normal force of main tower, and is used this time. These structural elements is very complex the structure and direction of load delivered from socket specially calbe particularly be different, and need FEM analysis that use Thick Shell element for suitable arrangement of mutual stress flowing grasping and absence that follow hereupon because all of the each support plate angle that suport this differ.

  • PDF

Measurement of Variation in Water Equivalent Path Length by Respiratory Organ Movement

  • Minohara, Shinichi;Kanai, Tatsuaki;Endo, Masahiro;Kato, Hirotoshi;Miyamoto, Tadaaki;Tsujii, Hirohiko
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.90-93
    • /
    • 2002
  • In particle radiotherapy, a shape of the beam to conform the irradiation field is statically defined by the compensator, collimator and potal devices at the outside of the patient body. However the target such as lung or liver cancer moves along with respiration. This increases the irradiated volume of normal tissue. Prior discussions about organ motions along with respiration have been mainly focused on inferior-superior movement that was usually perpendicular to beam axis. On the other hand, the change of the target depth along the beam axis is very important especially in particle radiotherapy, because the range end of beam (Bragg peak) is so sharp as to be matched to distal edge of the target. In treatment planning, the range of the particle beam inside the body is calculated using a calibration curve relating CT number and water equivalent path length (WEL) to correct the inhomogeneities of tissues. The variation in CT number along the beam path would cause the uncertainties of range calculation at treatment planning for particle radiotherapy. To estimate the uncertainties of the range calculation associated with patient breathing, we proposed the method using sequential CT images with respiration waveform, and analyzed organ motions and WELs at patients that had lung or liver cancer. The variation of the depth along the beam path was presented in WEL rather than geometrical length. In analyzed cases, WELs around the diaphragm were remarkably changed depending on the respiration, and the magnitude of these WEL variations was almost comparable to inferior-superior movement of diaphragm. The variation of WEL around the lung was influenced by heartbeat.

  • PDF

Micro Shock Tube에서 발생하는 충격파 실험 (Experimental Study of the Shock Wave Dynamics in Micro Shock Tube)

  • 박진욱;김규완;김희동
    • 한국추진공학회지
    • /
    • 제17권5호
    • /
    • pp.54-59
    • /
    • 2013
  • 현재 Micro Shock Tube는 다양한 공학응용분야에 적용되고 있으며, 특히 우주항공 및 연소기술 그리고 약물전달 등의 분야에서 광범위한 잠재력을 가진 장치 중 하나이다. 그러나 Micro Shock Tube에서의 유동 특성은 작은 직경으로 인해 형성되는 매우 낮은 Reynolds Number와 높은 Knudsen Number의 영향으로 일반적으로 잘 알려진 Macro Shock Tube의 유동 특성과 상이하게 나타난다. 본 연구에서는 이러한 Micro Shock Tube의 유동 특성을 상세히 연구하기 위해 직경이 다른 두 가지 Micro Shock Tube의 실험을 수행하였다. 충격파 전파를 측정하기 위해 고압관의 파막압력 그리고 저압관의 세 지점에 센서를 설치하여 압력을 측정하고 분석하였다. 본 연구로부터, 동일한 파막압력에서 Micro Shock Tube 직경의 증가에 따라 충격파 전파속도가 증가하였고, 반사파의 영향도 더 크게 받았다.

만성요통환자의 호흡패턴이상과 통증과의 상관관계 (Relationship between Breathing Pattern Disorder and Pain in Patients with Chronic Low Back Pain)

  • 임재길
    • 한국엔터테인먼트산업학회논문지
    • /
    • 제14권4호
    • /
    • pp.355-363
    • /
    • 2020
  • 이 연구는 만성요통환자의 호흡패턴이상과 통증관의 상관관계를 알아보기 위해 실시하였다. 104명의 만성요통환자의 날숨끝 이산화탄소농도(EtCO2)와 호흡률을 카프노그래프를 통해 측정하였고, 호흡유지시간과 Nijmegen Questionnaire, 가슴우리 움직임거리, 시각적사상척도를 추가로 평가하였다. Pearson's 검사로 상관관계를 분석하였으며, 결과는 EtCO2와 BHT, 가슴우리 움직임거리에서 통계적으로 유의한 상관관계를 보였으며(r=.302, r=.281)(p<.01), RR과 VAS에서 낮은 음의 상관관계(r=-.253,-.200)(p <.05)를 보였다. RR과 NQ에서도 유의한 상관관계를 보였으며(r=.237)(p<.05). 가슴우리 움직임거리와 VAS사이에서는 낮은 음의 상관관계를 보였다(r=-.370)(p<.01). 가슴 호흡과 가로막호흡 사이의 EtCO2, RR, BHT, 가슴우리 움직임거리, 그리고 VAS에서 통계적으로 유의한 차이가 있었으며(p<.05), NQ에서는 유의한 차이가 없었다(p>.05). 만성요통환자의 EtCO2, BHT, 가슴우리움직임거리, RR, 그리고 VAS 사이에는 상관관계가 있었다. 또한, RR과 NQ, 흉부 소풍과 VAS 사이에는 상관관계를 보였다. 결과적으로 호흡패턴이상과 통증 사이에는 밀접한 관계가 있었으며, 가슴호흡과 가로막호흡의 비교에서 EtCO2, RR, BHT, 가슴우리 움직임거리 및 VAS에서 유의한 차이가 있었다. 이것은 만성요통환자의 재활 및 통증 관리에서 호흡패턴중재가 기초자료로 사용될 수 있을 것으로 사료된다.

Influence of stiffeners on the performance of blind-bolt end-plate connections to CFST columns

  • Ding, Fa-xing;Pan, Zhi-cheng;Liu, Peng;Huang, Shi-jian;Luo, Liang;Zhang, Tao
    • Steel and Composite Structures
    • /
    • 제36권4호
    • /
    • pp.447-462
    • /
    • 2020
  • The paper aims to investigate the mechanical mechanism and seismic effect of stiffeners in blind bolt endplate connection to CFST column. A precise 3D finite element model with considering the cyclic properties of concrete and steel materials was established, and the efficiency was validated through monotonic and cyclic test data. The deforming pattern and the seismic performance of the unstiffened and stiffened blind bolt endplate connections were investigated. Then a parametric analysis was conducted to analyze the contribution of stiffeners and the joint working behaviors with endplate under cyclic load. The joint stiffness classifications were compared and a supplement stiffness classification method was proposed, and the energy dissipation ability of different class connections were compared and discussed. Results indicated that the main deformation pattern of unstiffened blind bolt endplate connections was the local bending of end plate. The vertical stiffeners can effectively alleviate the local bending deformation of end plate. And influence of stiffeners in thin endplate and thick endplate was different. Based on the stiffness of external diaphragm welded connection, a more detailed rigidity classification was proposed which included the pin, semi-rigid, quasi-rigid and rigid connection. Beam was the main energy dissipation source for rigid connection. For the semi-rigid and quasi-rigid connection, the extended endplate, stiffeners and steel beam would all participate in the energy dissipation.

공압식 심실 보조기의 동물실험 (Animal Experiment of the Pneumatic Ventrivular Assist Device)

  • 박성식;김삼현;서필원;최창휴;이상훈;이혁수;황승옥;안혁
    • Journal of Chest Surgery
    • /
    • 제32권12호
    • /
    • pp.1065-1077
    • /
    • 1999
  • Background : Ventricular assist devices(VADs) are being used for patients in postcvardiotomy cardiogenic shock status bridge to cardiac transplant settings and in post-myocardial infarction cardiogenic shock. The VAD which was developed at the Deparment of medical engineering in Dankook University College of Medicine was a pneumatically driven device and can maintain pulsatile flow. The goal of this study is to develop animal experimental models using the VAD and to clarify the reliability and hemodynamic property adequacy of end organ perfusion durability and severity of thrombotic-hemolytic tendency of the device. Material and Method : The pneumatic VAD was applied to 8 adult female lambs, We examined some hemodynamic parameters such as arterial blood pressure pulmonary capillary wedge pressure(pcwp) pulmonary artery pressure(PAP) left atrial pressure hour urine output cardiac index VAD flow EKG to determine the reliability of the VAD and hemodynamic compatibility of the experimental animals within 24 hours of experiment. We also observed the end organ perfusion durability of the VAD and thrombotic-hemolytic property of the VAD after 24 hours of VAD insertion. Result: We could monitor all hemodynamic parameters including pcwp PAP cardiac index EKG, adn hour urine as true clinical settings. We observed that the reliability of the VAD was excellent and the hemodynamic property of the experimental animal and end organ perfusion were adequate within 24 hours of experiment. In four lambs surviving 24 hours after insertion the reliability of the VAD and end organ perfusion were excellent and no thrombotic-hemolytic tendency was noted. However after 15 days of experiment the diaphragm of the VAD was torn and it was recommende that the durability of the VAD should be extended. Conclusion : e conclude that the pneumatic VAD developed at Dankook University Biomedical Engineering has good hemodynamic property and low thromboembolic tendency and presents adequate end organ perfusion but we noted that the durability of the device should be expanded further. It will be possible to do more reliable experiment in the future according to the animal experimental method developed in this study especially with the heart failure models.

  • PDF

기도결찰을 시행한 토끼 태자의 실험적 횡격막탈장에서 Lamellar body counts (Lamellar Body Counts in Fetal Rabbits' Experimental Diaphragmatic Hernia and Tracheal Ligation)

  • 전용순;정수진;이정녀
    • Advances in pediatric surgery
    • /
    • 제17권2호
    • /
    • pp.179-187
    • /
    • 2011
  • Experimental tracheal ligation (TL) has been shown to reverse the pulmonary hypoplasia associated with congenital diaphragmatic hernia (CDH) and to normalize gas exchange. The purpose of this study was to determine whether the TL would correct the surfactant deficiency present in the fetal rabbit model of CDH by using lamellar body count. Lamellar bodies are synthesized and secreted by the type II pneumocytes of fetal lung. The phospholipids present in these bodies constitute the major component of pulmonary surfactant. Twenty-one pregnant New Zealand rabbits underwent hysterotomy and fetal surgery on gestational day 24. Two fetuses of each pregnant rabbit were operated. In the fetus of one end of bicornuate uterus, left DH was created by excision of fetal diaphragm through open thoracotomy (DH Group). In the fetus of the other end of bicornuate uterus, left DH and TL were created (TL Group). The fetuses were delivered by Cesarean section on gestational day 31. Fourteen in control group, 12 in the DH group and 13 in TL group were born alive. En bloc excision of lungs, bronchi and trachea was done in all newborn rabbits. A five Fr catheter was inserted through trachea and repeated irrigations with 10 cc normal saline were done. The irrigated fluid was centrifuged at $280{\times}g$ for 5 minutes and the lamellar bodies were counted with the upper level fluid in platelet channel of electronic cell counter. The average lamellar body counts were $37.1{\pm}14.2{\times}10^3/{\mu}L$ in control group, $11.5{\pm}4.4 {\times}10^3/{\mu}L$ in DH group, and $6.5{\pm}0.9{\times}10^3/{\mu}L$ in TL group. Lamellar body count in DH group was lower than in control group and did not increase after TL. This study shows TL has no therapeutic effect on decreased surfactant level of CDH and the pregnant rabbit is appropriate for the animal model of CDH.

  • PDF

강교 부재의 상세 설계정보 표현을 위한 IFC기반의 데이터 모델 확장 (An Extended Data Model based on the IFC for Representing Detailed Design Information of Steel Bridge Members)

  • 이진훈;이지훈;김효진;이상호
    • 한국전산구조공학회논문집
    • /
    • 제21권3호
    • /
    • pp.253-263
    • /
    • 2008
  • IAI의 IFC를 기반으로 강 교량을 구성하는 부재의 상세 설계 정보를 표현하기 위한 방안을 제시하였다. 이를 위해 먼저 강교 부재 상세 설계와 관련한 설계기준, 구조계산서, 상세설계도면을 분석하여 실무에서 다루어지는 설계 데이터 항목과 이들의 표현방식을 분류하였다. 설계 항목을 기존 IFC 모델로 표현 가능한 것, 추가 모델이 필요한 것으로 나누었고, 보강재, 격벽, 현장 연결부, 그리고 전단연결재를 보다 체계적으로 표현하기 위한 속성 및 위상관계를 정립하였다. 마지막으로 본 연구를 통해 제시된 데이터모델을 기반으로 설계 정보 입력을 위한 프로그램을 구현하였다. 테스트용 교량에 적용하여 물리적 STEP 파일 생성함으로써 제시한 데이터 모델의 논리성을 확인하였다.