• 제목/요약/키워드: enclosure fire

검색결과 60건 처리시간 0.027초

밀폐공간에서의 VCE에 의한 충격파 고찰 (A Study on the Shock Wave caused by VCE in Enclosure)

  • 임사환;허용정;이종락
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.54-59
    • /
    • 2007
  • In order to establish detailed plans for fire protection and reduce the possible fire accidents in the future, a study on the shock wave caused by VCE(Vapor Cloud Explosion) is very important. Destruction phenomena of structure by gas explosion is due to the explosion pressure and heat. Explosion pressure is a kind of energy converted from the gas mixture explosion. Therefore, the propagation progress of shock wave and flame is very important. This study investigated the shock wave caused by VCE in enclosure with opened vent port. From a result, the vent port of top at the straight line of ignition and leak location was opened most rapidly, and the vertical vent port not opened.

  • PDF

A Study on the Estimation of Human Damage Caused by the LP Gas Flame in Enclosure using Probit Model

  • Leem, Sa-Hwan;Huh, Yong-Jeong
    • 한국가스학회지
    • /
    • 제13권3호
    • /
    • pp.43-48
    • /
    • 2009
  • The energetic and environmental problems have been getting serious after the revolution of modern industry. Therefore, demand of gas as an eco-friendly energy source is increasing. With the demand of gas, the use of gas is also increased, so injury and loss of life by the fire have been increasing every year. Hence the influence on flame caused by Vapor Cloud Explosion in enclosure of experimental booth was calculated by using the API regulations. And the accident damage was estimated by applying the influence on the adjacent structures and people into the PROBIT model. According to the probit analysis, the spot which is 5meter away from the flame has nearly 100% of the damage probability by the first-degree burn, 27.8% of the damage probability by the second-degree burn and 14.5% of the death probability by the fire.

  • PDF

선박 거주구역용 소화시스템의 전산 시뮬레이션 (COMPUTATIONAL SIMULATION OF FIRE SUPPRESSION SYSTEM FOR CABINS OF SHIPBOARD ENCLOSURE)

  • 정인수;정희택;한용식
    • 한국전산유체공학회지
    • /
    • 제21권4호
    • /
    • pp.40-45
    • /
    • 2016
  • The numerical simulation has been performed to predict the performance of the fire suppression system for cabin of shipboard enclosure. The present study aims ultimately at finding the optimal parametric conditions of the mist-injecting nozzles using the CFD methods. The open numerical code was used for the present simulation named as FDS (Fire Dynamics Simulator). Application has been done to predict the interaction between water mist and fire plume. In this study, the passenger cabin was chosen as simulation space. The computational domains for simulation in the passenger cabin were determined following the fire scenario of IMO rules. The full scale of the flow field is $W{\times}L{\times}H=4{\times}3{\times}2.4m^3$ with a dead zone of $W{\times}L{\times}H=1.22{\times}1.1{\times}2.4m^3$. The water mist nozzle is installed in ceiling center of 2.3 m height from the floor, and there are six mattresses and four cushions in the simulation space. The combination patterns of orifices to the main nozzle and the position to install nozzles were chosen as the simulation parameters for design applications. From the present numerical results, the centered-located nozzles having evenly combined orifices were shown as the best performance of fire suppression.

화재 특성 고찰을 통한 농연 극복 센서 모듈 (A Sensor Module Overcoming Thick Smoke through Investigation of Fire Characteristics)

  • 조민영;신동인;전세웅
    • 로봇학회논문지
    • /
    • 제13권4호
    • /
    • pp.237-247
    • /
    • 2018
  • In this paper, we describe a sensor module that monitors fire environment by analyzing fire characteristics. We analyzed the smoke characteristics of indoor fire. Six different environments were defined according to the type of smoke and the flame, and the sensors available for each environment were combined. Based on this analysis, the sensors were selected from the perspective of firefighter. The sensor module consists of an RGB camera, an infrared camera and a radar. It is designed with minimum weight to fit on the robot. the enclosure of sensor is designed to protect against the radiant heat of the fire scene. We propose a single camera mode, thermal stereo mode, data fusion mode, and radar mode that can be used depending on the fire scene. Thermal stereo was effectively refined using an image segmentation algorithm, SLIC (Simple Linear Iterative Clustering). In order to reproduce the fire scene, three fire test environments were built and each sensor was verified.

철도차량 안전기준을 만족하는 철도차량 내장재의 화재성능 시험 (Fire test for interior material satisfied with the guide for the safety of rail vehicle)

  • 박원희;이덕희;정우성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2149-2153
    • /
    • 2008
  • A large-scale fire test was done for interior materials from a vehicle installed within a fire test room. The interior materials are satisfied with the Korean guide for the safety of rail vehicle. The guide has taken effect since December 2004 in Korea. Ignition source (gas burner) was increased in several controlled steps. The objectives of this test are to assess the fire performance in terms of ignition and flame spread on interior lining materials and to provide data on an enclosure fires involving train interior materials that grow to flashover. This data will be used to develop and calibrate an Fire Dynamics Simulator (FDS) model for fire growth on the interior vehicle.

  • PDF

화재하중을 고려한 대공간 제배연 용량 최적화 연구 (Optimization for Ventilation Capacity of Large Enclosure Considering Fire Load)

  • 안찬솔;김아람
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 추계학술논문발표회 논문집
    • /
    • pp.478-481
    • /
    • 2011
  • This study is intended to evaluate and optimize the characteristics of smoke spreading and the appropriateness of evacuation time extended by operation of smoke control system during fire within the underground space of the building structured in compliance with the smoke control system performance criteria from the local fire safety standard, which has been currently applied to the buildings in Korea. Using the heat release per unit weight of the combustibles, a numerical analysis both in case of smoke control system in operation and the system not in operation was carried out at the several different shopping malls. From the viewpoint of securing the evacuation time, the results were compared in an attempt to assess the appropriateness of the fire safety criteria.

  • PDF

룸코너 설비를 이용한 내장재 교체 전 철도차량의 화재성능 시험 (Fire Test for the railway vehicle before interior replacement in Room Corner)

  • 이덕희;박원희;정우성;이동찬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.590-595
    • /
    • 2008
  • A large-scale fire test was done for interior materials from a vehicle installed within a fire test room. The interior materials are the old style before interior replacement by the Korean guideline for the safety of rail vehicle. Ignition source (gas burner) was increased in several controlled steps. The objectives of this test are to assess the fire performance in terms of ignition and flame spread on interior lining materials and to provide data on an enclosure fires involving train interior materials that grow to flashover. This data will be used to develop and calibrate an Fire Dynamics Simulator (FDS) model for fire growth on the interior vehicle.

  • PDF

밀폐공간에서의 화재 위험성에 관한 연구 (A Study on fire risk in an enclosure room)

  • 김수영;김홍식;한동훈;이성룡;김주석;육근환;천성수
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2009년도 춘계학술논문발표회 논문집
    • /
    • pp.449-453
    • /
    • 2009
  • 기존 주택 및 고층건물화재에서 발생하는 화재 폭발 사고에 대해서는 많은 연구가 이루어지고 있으나, 이천 냉동창고 화재와 같이 많은 인명피해가 발생되는 작업환경에서의 화재 특히 밀폐공간에서의 화재 폭발 위험성 및 특성은 주택 및 고층건물화재에 비교하여 높은 폭발위험성 및 빠른 화염전파 특성을 보이나 이에 관한여 구체적인 연구는 미비한 실정이다. 본 연구는 밀폐공간 작업환경에서의 화재 폭발 위험성 특성 분석을 위하여 밀폐공간에서 작업 시 발생되어지는 가연성 가스의 확산 특성 분석 및 폭발 위험성 분석 방법에 관한 연구와 밀폐공간에서의 화염 확산 특성에 관한 연구논문 이다.

  • PDF

환기부족 구획화재의 열적 특성 (Thermal Characteristics of Under Ventilated Compartment Fire)

  • 김성찬
    • 설비공학논문집
    • /
    • 제21권1호
    • /
    • pp.41-48
    • /
    • 2009
  • The present study has been performed to investigate the thermal characteristics of under-ventilated compartment fire which is a typical fire condition in structures. A series of fire experiments was conducted to characterize the thermally driven flow in a 2/5 scale ISO 9705 fire compartment. Three different fuels were used in this test series, methane gas, heptane pool, and polystyrene pellets fire. In order to measure accurate temperature, double shield aspirated thermocouples reducing the effect of radiative energy exchange on temperature measurement were used in addition to bare bead thermocouples. The upper layer temperature for well ventilated fire was increased with increasing heat release rate, but it was slightly decreased for under-ventilated fire. The measured temperatures in the upper layer at the front sampling location were higher than at the rear. Thermal characteristics through the doorway were also analysed for a wide range of heat release rates. This study provides a comprehensive and quantitative assessment of fire behavior for under-ventilation condition of fire.