Browse > Article

Thermal Characteristics of Under Ventilated Compartment Fire  

Kim, Sung-Chan (School of Fire and Disaster Prevention, Kyungil University)
Hamins, Anthony (Building and Fire Research Lab., NIST)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.21, no.1, 2009 , pp. 41-48 More about this Journal
Abstract
The present study has been performed to investigate the thermal characteristics of under-ventilated compartment fire which is a typical fire condition in structures. A series of fire experiments was conducted to characterize the thermally driven flow in a 2/5 scale ISO 9705 fire compartment. Three different fuels were used in this test series, methane gas, heptane pool, and polystyrene pellets fire. In order to measure accurate temperature, double shield aspirated thermocouples reducing the effect of radiative energy exchange on temperature measurement were used in addition to bare bead thermocouples. The upper layer temperature for well ventilated fire was increased with increasing heat release rate, but it was slightly decreased for under-ventilated fire. The measured temperatures in the upper layer at the front sampling location were higher than at the rear. Thermal characteristics through the doorway were also analysed for a wide range of heat release rates. This study provides a comprehensive and quantitative assessment of fire behavior for under-ventilation condition of fire.
Keywords
Enclosure; Compartment fire; Under ventilated fire; Reduced scale experiment;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 McGrattan, K. B., Baum, H. R. and Rehm, R. G., 1998, Large Eddy Simulations of Smoke Movement, Fire Safety Journal, Vol. 30, No. 2, pp. 161-178   DOI   ScienceOn
2 Blevins, L. G. and Pitts, W. M., 1999, Modeling of Bare and Aspirated Thermocouples in Compartment Fires, Fire Safety Journal, Vol. 33, pp. 239-259   DOI   ScienceOn
3 Kim, S. C. and Lee, S. C., 2006, Numerical prediction of smoke concentration in a compartment fire by using the modified volumetric heat source model, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 18, No. 4, pp. 344-350   과학기술학회마을   ScienceOn
4 Tran, H. C. and Janssen, M. L., Room Fire Test for Fire Growth Modeling-A Sensitivity Study, Journal of Fire Science, Vol. 7, No. 4, pp. 217-236   DOI
5 McGrattan, K. B., Klein, B. W., Hostikka, S. and Floyd, J. E., 2007, Fire Dynamics Simulator(Version 5), User’s Guide, NIST Special Publication 1019-5, National Institute of Standards and Technology, Gaithersburg, Maryland
6 Drysdale, D., 1986, An Introduction of Fire Dynamics, A wiley-Interscience Publication
7 Steckler, K. D., Quintiere, J. G. and W. J. Rinkinen, 1982, Flow induced by fire in a compartment, NBSIR 82-2520, National Bureau of Standards, MD, USA
8 McCaffrey, B. J. and Heskestad, G., 1976, Robust Bidirectional Low-Velocity Probe for Flame and Fire Applications, Combustion and Flame, Vol. 26, No. 1, pp. 125-127   DOI   ScienceOn
9 Parker, W. J., 1984, Calculations of the Heat Release Rate by Oxygen Consumption for Various Applications, Journal of Fire Science, Vol. 2, No. 5, pp. 380-395   DOI   ScienceOn
10 Blomqvist, P. and Lonnermark, A., 2001, Characterization of the combustion products in large-scale fire tests : Comparison of three experimental configurations, Fire and Materials, Vol. 25, No. 2, pp. 71-81   DOI   ScienceOn
11 Kim. S. C. and Hamins, A., 2008, On the temperature measurement bias and time response of an aspirated thermocouple in fire environment, Journal of Fire Science, Vol. 26, No. 6, pp. 509-529   DOI   ScienceOn
12 Pitts, W. M., 1995, The Global Equivalence Ratio Concept and the Formation Mechanism of Carbon-Monoxide in Enclosure Fire, Progress in Energy and Combustion Science, Vol. 21, No. 3, pp. 197-237   DOI   ScienceOn